Military Engineer Services - Punjab

35740784 providing of ph i of otm accn for mech inf bn at ferozepur under ge ( east ) ferozepur cantt 1 note: (i) please refer schedule a notes given on serial page no. 21 to 27 of tender documents. 2 lumpsum/ other pre priced provisional schedules of works 3 lump sum price worked out by the contractor for building works as listed in schedule a part i brought forward from serial page no. 29. 4 lump sum price worked out by the contractor for site clearance and earthworks as listed in schedule a part ii brought forward from serial page no. 30. 5 lump sum price worked out by the contractor for internal electrification works as listed in schedule a part iii brought forward from serial page no. 37. 6 lump sum price worked out by the contractor for internal water supply works as listed in schedule a part iv brought forward from serial page no. 38. 7 lump sum price worked out by the contractor for sewage disposal works as listed in schedule a part v brought forward from serial page no. 40. 8 lump sum price worked out by the contractor for road, pathand culverts works as listed in schedule a part vi brought forward from serial page no. 42. 9 lump sum price worked out by the contractor for area drainage works listed in schedule a part vii brought forward from serial page no. 43. 10 lump sum price worked out by the contractor for boundary wall, compound wall,fencing and gate works listed in schedule a part viii brought forward from serial page no. 45. 11 lump sum price worked out by the contractor for external water supplyworks as listed in schedule a part ix brought forward from serial page no. 46. 12 lump sum price worked out by the contractor for external electrificationworks as listed in schedule a part x brought forward from serial page no. 50. 13 lump sum price worked out by the contractor for dg set works as listed in schedule a part xi brought forward from serial page no. 51. 14 lump sum price worked out by the contractor for summer appliances worksas listed in schedule a part xii brought forward from serial page no. 53. 15 lump sum price worked out by the contractor for rain water harvesting worksas listed in schedule a part xiii brought forward from serial page no. 54. 16 lump sum price worked out by the contractor for hot water supply works as listed in schedule a part xiv brought forward from serial page no. 56. 17 lump sum price worked out by the contractor forlightening conductor works as listed in schedule a part xv brought forward from serial page no. 57. 18 lump sum price worked out by the contractor for bore well works as listed in schedule a part xvi brought forward from serial page no. 58. 19 lump sum price worked out by the contractor for stp works as listed in schedule a part xvii brought forward from serial page no. 59. 20 lump sum price worked out by the contractor for treated sewage water supply works as listed in schedule a part xviii brought forward from serial page no. 60. 21 lump sum price worked out by the contractor for pcc hard standing works as listed in schedule a part xix brought forward from serial page no. 61. 22 schedule a part xx misc items internal electrification works 23 supply and fix energy efficient led bulb, b229 watt complete all as specified and directed. make: cat no lhldbweb4l8r009 of havells or eqvt in philips and cg. 24 supply and fix modular rj telephone socketcomplete all as specified and directed by engr in charge. make: cat no / sap code ahlkhww000 of havells or eqvt in legrand/ schneider. 25 supply and fix modular tv socket complete all as specified and directed by engr in charge.cat no /sap code ahlkt0w000 of havells or eqvt in legrand/ schneider. 26 supply and fixdecorative 9w ledwall mounting fittings complete set including 9 w led lamp all as specified and directed. make: cat no lhf0eceitzib014 glaze wall light of havellsor eqvt in philips / crompton. 27 s&f gi pipe bracket made out of gi pipe light grade 32 mm dia and bend to shape 1.5 mtr long ms clamps made out of ms flat iron of size 25x4 mm thick with nuts & bolts, washers complete as specified and directed 28 supply and fix wall mounting fan industrial type 450mm sweep, 230v, 50hz , 1400 rpm, 100w, 150cum/hr air delivery, copper motor, double ball bearing , 60db 65db nosie level, upward and down adjustable, 60 degree oscillation degree, 3 nos metal balde guarded with 112 spokes metal case complete with mountings accessories kit, wall bracket, nut, bolt washer etc with connection pvc three core copper wire all as specified and directed. make: cat no fhacwstscl18 of havells or eqvt in legrand/ philips. 29 sewage disposal works 30 material and labour for laying dwc hdpe 150mm (i/d) sn8 pipe including all necessary fittings for carrying sewage complete all as directed by engineer in charge. 31 material and labour for laying dwc hdpe 200mm (i/d) sn8 pipe including all necessary fittings for carrying sewage complete all as directed by engineer in charge. 32 material and labour for construction of under gournd sump cum pump house complete all as shown on drawings and as specified. (drg no cejz 04/2000 sheet no. 1/2 to 2/2). 33 road, pathand culverts works 34 material and labour for cat eye abs plastic with nail of size 100mm x 100mm, 20mm reflective glass colour white/ red/ yellow provided with steel zinc plated with bolt of 12mm dia length 120mm for fixing on road by hammering complete all as directed by engineer in charge. 35 material and labour for delineator 47mm dia 600mm long with high intensity reflective sheeting complete all as directed by engineer in charge. 36 external water supply works 37 supplying, laying, jointing and testing in trenches centrifugally cast 150mm bore ductile iron pipe class k 7 conforming to is : 8329 2000 of min wall thickness 5.4mm including testing complete all as specified. 38 supplying, laying, jointing and testing in trenches centrifugally cast 100mm bore ductile iron pipe class k 7 conforming to is : 8329 2000 of min wall thickness 5.4mm including testing complete all as specified notes for srl no. 6.01 & 6.02 : (a) excavation, earth work and di fittings shall be measured and paid for separately under respective items(b) cost of tyton joints is included in the rate quoted.(c) standard length of the pipe should be 5.50m or 6.0m as available.(d) the measurement of the pipe shall be net as fixed between the fittings including short length without any allowance for cutting and wastage and for the portion entering in the socket of all pipes and fittings.(e) predespatch inspection & testing of di pipe shall be carried out by the representative of ao. all the expenditure for the same shall be borne by the contractor and the quoted rates shall be deemed to be included for the same 39 supply, fixing and testing ductile iron fittings such as bends (any type radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘y’ junction. double branch, cross (all sockets or sockets and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket. spigot caps and plugs suitable for 100 to 150mm ductile iron pressure pipes of k 7 classification and push on flexible rubber gasket joints complete all as specified and directednotes :(a) di fittings shall be of same make as of di pipes or of make as recommended by manufacturers(b) the weight of the fittings shall be measured and paid as given in relevant is or actually provided whichever is less.(c) all fittings shall be relevant is stamping marking.(d) excavation and earth work shall be measured and paid for separately.(e) cost of the joints and jointing materials shall be deemed to be included in the relevant items of di pipes here in before 40 construction of brick masonary valve pit chamber of 1050mm x 750mm x 1000mm size (internal dimensions) with ms sheet cover 6mm thick and angle iron 40mm x 40mm x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified and shown on drgs. breakdown of qtyexternal water supply 4 (each)treated sewage water supply 2 (each) 41 construction of brick masonary valve pit chamber of 900 x 900 x 1000mm size (internal dimensions) with ms sheet cover 6mm thick and angle iron 40 x 40 x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified andshown on drgs. breakdown of qtyexternal water supply 5 (each)treated sewage water supply 3 (each) 42 construction of brick masonary valve pit chamber of 600mm x 600mm x 1000mm size (internal dimensions) with ms sheet cover 6mm thick and angle iron 40mm x 40mm x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified andshown on drgs. note for srl item no. 6.04 to 6.06: 43 supply and fixing rcc water main route indicator of size 75cm x 40cm x 10cm duly marked with mes water mains bore made of cement concrete (1:2:4) type b 1 as in foundation of electric poles/ struts etc including necessary form work, fair, finished embedded in pcc bed including necessary excavation and re filling, proposed to be installed after 25m on pipe lines of size 150mm, 100mm, 80mm and 50mm complete all as directed by engineer in charge. 44 external electric supply works 45 supply ,install, testing and commissioning power factor control lt panel board (apfc) of 200 kvar, 433 volt, 50 cycle per second cubical type front and back openable double leaf type dust & vermin proof with locking arrangement powder coated with approved colour , made out of crca sheet 14 swg, outdoor herewith canopy, cable entry glands, double compressor type, duly prewired with suitable pillar made out of 50 mmx 50mm x6 mm angle iron grouted in and including pcc (1:2:4) using 20 mm graded stone aggregate complete all as per is 8623 1933 & all as per latest isi specification and suitable for housing and including following accessories : (a) incoming mccb of 250 amps 36 ka rupturing capacity , 3 pole thermal magnetic release type shunt trip coil 01 no (b) copper bus bar duly insulated with colour coded heat shrinkable sleeve insulation for three phase four wire system of 250 amps capacity rating with suitable size/ type on hygroscopic on combustion track resistance, high strength frp/mc/dmc insulators.(c) capacitor switching contactor of suitable capacity (contractor amps rating shell not be less than 1.5 times nominal current rating, three pole, coil voltage 440 volts, one each for number of capacitor bank , each contractor shell be protected with 10 ka , d curve type (mcb to be provided for 1.33 times kvar i.e. 100 % current capacity of the mpfcs irrespective of the fact that contractor’s rating is 1.5 times) (mccb 25 ka shall be provided for the above 63 amps rating)(d) one set current transformer (cts) of suitable ratio (with secondary of 5 amps ) to be fixed on bus bar of existing panel including connection with 2 core 1.5 sqmm armoured copper conductor complete with gland etc.(e) shunt capacitor mpp type heavy duty 200 kvar distributed in step of 6 steps with configuration (2x12.5 + 1x25 + 3x50) directly connected to maintain power factor at 0.99 or unity, housed in self extinguishing insulated material with built in. 46 supply and fixing 3 core 1.5 sqmm pvc insulated and frls pvc round sheathed copper conductor flexible 1100 volts for connection from junction box to street light fittings complete all as specified and directed. make :polycab/ havells/ finolex/ paragon 47 supply and fixing street light pole cable junction box ip 65 with metric knockouts for cable entry with mcb sp 6 amps,10 ka and the box made out of thermal plastic material suitable for 16/25 sqmm ug cable including clamps bolts, nuts, duly painted etc complete all as and directed by engineer in charge. 48 supply and fixing bracket made out of 40 mm dia gi light grade tubing 1.2 meter long and bent to angle /shape of 120 degree angle at the meddle from vertical fixed with clamps nuts and bolts washers complete all as specified and directed 49 supply and fixing automatic street light switchfor automatic switching of street light/high mast light (timer switch)for three phase loadlight.the digital timer 24 hrs alongwith suitable power contractor as per iec 60947 4 1, including incoming & outgoing mcbs, smc enclosure and support terminal and enclosed in pole/wall mounted factory made pvc enclosure made out of rust proof, shock & termite proof and frls grade confirming to ip 54 of capacity 6 kw, three phase, current rating 32/tp and mcb rating 40/tpn, having facility of manual operation complete all as directed by engineer in charge. 50 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac,3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.8 m x 1.5 m x 1.0 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location main panel (x mer 400 kva)(i) panel having common aluminium bus bar of capacity 1600 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)acb microprocessor released and thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 800 amp 4 pole, 50 kawith overload variation 40 100% 1 no,(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 amp 3 pole, 35 ka with overload variation 40 100% 1 no,(for apfc ) (b) do but 250 amp 1 no, (c) do but 160 amp 1 no, (d) do but 125 amp 02 nos,(e) do but 63 amp 6 nos,(iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 800 amps digital type square shape 96mm flush mounted with selector switch and cts 800/5 a 1 no.(vi) phase indicating lamp led type 03 nos 51 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac,3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location near smbk(i) panel having common aluminium bus bar of capacity 500 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 amp 4 pole, 35 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, 16 ka with overload variation 40 100% 4 nos. (b) do but 32 amp 2 nos, (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 250 amps digital type square shape 96mm flush mounted with selector switch and cts 250/5 a 1 no.(vi) phase indicating lamp led type 03 nos 52 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtrbelow gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location near jco mess(i) panel having common aluminium bus bar of capacity 320 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 160 amp 4 pole, icu=ics=35 kawith overload variation 40 100% 1 no.(iii) outgoing(a) mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 80 amp 4 pole, icu=ics=25 ka with overload variation 40 100% 1 no. (b)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 4 nos. (c)mcb isolator 25 amp spn 10 ka, 240v 01 no, (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 160 amps digital type square shape 96mm flush mounted with selector switch and cts 160/5 a 1 no.(vi) phase indicating lamp led type 03 nos 53 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location near offr mess(i) panel having common aluminium bus bar of capacity 250 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 125 amp 4 pole, icu=ics=25 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 2 nos. (b)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=25 ka with overload variation 40 100% 2 nos. (c)mcb isolator 32 amp spn 10 ka, 240v 04 nos, (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 125 amps digital type square shape 96mm flush mounted with selector switch and cts 125/5 a 1 no.(vi) phase indicating lamp led type 03 nos 54 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location near adm block(i) panel having common aluminium bus bar of capacity 250 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 125 amp 4 pole, icu=ics=25 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 2 nos. (b)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=25 ka with overload variation 40 100% 2 nos. (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 125 amps digital type square shape 96mm flush mounted with selector switch and cts 125/5 a 1 no.(vi) phase indicating lamp led type 03 nos 55 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location mt area panel(i) panel having common aluminium bus bar of capacity 200 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, icu=ics=16 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 4 nos. (b)mcb isolator 25 amp spn 10 ka, 240v 10 nos. (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 100 amps digital type square shape 96mm flush mounted with selector switch and cts 100/5 a 1 no.(vi) phase indicating lamp led type 03 nos 56 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.4 m x 1.25 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location street light panel(i) panel having common aluminium bus bar of capacity 200 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, icu=ics=16 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 3 nos. (b)on load change over switch 415v in sheet metal enclosures 4 pole of capacity 63 amp. (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 100 amps digital type square shape 96mm flush mounted with selector switch and cts 100/5 a 1 no.(vi) phase indicating lamp led type 03 nosnote srl item no. 7.06 to 7.12: lt panel shall be got tesed from cpri type test for 4000 amp with breaking capacity not less than 65 ka and ip 56 as per is 61439 part 1& 2. 57 supply and fixing of rubber mat (insulation mat) of dimension 1m x 2m and 2 mm thick complete for electrical installation and dg sets panels complete all as directed by engineer in charge. 58 supply and fixing of rubber mat of dimension 1m x 2m and 3 mm thick complete for electrical installation and stp main panels complete all as specified and directed. 59 supply and fixing rcc ht cable route indicator of size 75cmx40cmx10cm duly marked with ht cable made ofcement concreted (1:2:4) type b 1 as in foundation of electric poles/struts/ etc including necessary form work, fair finished embedded in pcc bed including necessary excavation and re filling complete all as specified and directed 60 dg set works 61 supply, installing, commissioning and testing of eco friendly diesel engine driven generating set silent type confirming to cpcb conditions/ norms, 62.5 kva, or next higher capacity as available/manufactured at 0.9 power factor directly coupled alternator & engine. the diesel set shall consist of a diesel engine coupled directly to a matching parts or as recommended/ provided by the manufacturer on a common base frame and thereafter installed in the cpcb approved acoustic enclosure. the complete set conforming to and test certificate as per cpcb norms and as specified) complete without amf control panel standardized by manufacturer, fuel tank with mounting arrangement, flexible exhaust pipe complete with the following: (a) engine (prime mover) : diesel engine 1500 rpm of minimum 84 bhp or recommended by manufacturer turbo charged water cooled,12 volts electric battery start, complete with fly wheel and all standard fitting/ fixtures as per manufacturing practice including suitable engine control panel/ dash board with electronic technometer. lube oil temp and pressure gauges water temp gauge frequency meter (digital type) including safety self starter, alternator, cogged v belt, fuel tank with first fill of lube oil and coolant (as applicable) etc. (b) alternator :alternator ac 3 phase 415 volts 4 wire rated line current for output 62.5 kva, pf 0.8, 1500 rpm insulation class enclosures /spdp self exited self regulated brushes, complete with avr with plus and minus voltage regulation directly coupled to and match the above engine. (c) anti vibration pads for mounting engine, alternator assembly on base frame/plate or as recommended by the manufacturer.(d) base plate made out of structural steel as per manufacturer recommended design/specification.(e) acoustic enclosure of an internal type approved/certified acoustic enclosure (as per cpcb norms for the dg set) to restrict the noise level to 75 db at one meter distance and temp rise with in canopy shall not exceed 7 degree centigradebeyond ambient temp. it shall be made of 16 swg or manufacturer standard norms crca sheet with powder coated finish on outside and provided with non ignitic fire retardant foam as acoustic material. the doors and glass windows shall be ismc. it shall also include the following: (i) silencer/absorption the non resistance, residential and exhaust pipe covered with asbestos rope.(ii) internal wiring with pvc copper conductor cable is 694 marked frls in conduit and fluorescent lamp fittings.(iii) fuel tank of 16 hours cap but not less than made of 14 swg crca sheet duly powder coated and provided with float gauge and fuel float switch.(iv) one no 12 v x 180 ah 25 plates maintenance free batteries as recommended by manufacturer.(f) the exhaust of dg set shall be fitted with emission control devises as per latest cpcb norms and as specified and also contractor shall submit test certificate of dg set as per latest cpcb norms. 62 supply, installing, commissioning and testing of eco friendly diesel engine driven generating set silent type confirming to cpcb conditions/ norms, 40 kva, or next higher capacity as available/manufactured at 0.9 power factor directly coupled alternator & engine. the diesel set shall consist of a diesel engine coupled directly to a matching parts or as recommended/ provided by the manufacturer on a common base frame and thereafter installed in the cpcb approved acoustic enclosure. the complete set conforming to and test certificate as per cpcb norms and as specified) complete without amf control panel standardized by manufacturer, fuel tank with mounting arrangement, flexible exhaust pipe complete with the following: (a) engine (prime mover) : diesel engine 1500 rpm of minimum 51 bhp or recommended by manufacturer turbo charged water cooled,12 volts electric battery start, complete with fly wheel and all standard fitting/ fixtures as per manufacturing practice including suitable engine control panel/ dash board with electronic technometer. lube oil temp and pressure gauges water temp gauge frequency meter (digital type) including safety self starter, alternator, cogged v belt, fuel tank with first fill of lube oil and coolant (as applicable) etc. (b) alternator :alternator ac 3 phase 415 volts 4 wire rated line current for output 40 kva, pf 0.8, 1500 rpm insulation class enclosures /spdp self exited self regulated brushes, complete with avr with plus and minus voltage regulation directly coupled to and match the above engine. (c) anti vibration pads for mounting engine, alternator assembly on base frame/plate or as recommended by the manufacturer.(d) base plate made out of structural steel as per manufacturer recommended design/specification.(e) acoustic enclosure of an internal type approved/certified acoustic enclosure (as per cpcb norms for the dg set) to restrict the noise level to 75 db at one meter distance and temp rise with in canopy shall not exceed 7 degree centigradebeyond ambient temp. it shall be made of 16 swg or manufacturer standard norms crca sheet with powder coated finish on outside and provided with non ignitic fire retardant foam as acoustic material. the doors and glass windows shall be ismc. it shall also include the following: (i) silencer/absorption the non resistance, residential and exhaust pipe covered with asbestos rope.(ii) internal wiring with pvc copper conductor cable is 694 marked frls in conduit and fluorescent lamp fittings.(iii) fuel tank of 16 hours cap but not less than made of 14 swg crca sheet duly powder coated and provided with float gauge and fuel float switch.(iv) one no 12 v x 88 ah 25 plates maintenance free batteries as recommended by manufacturer.(f) the exhaust of dg set shall be fitted with emission control devises as per latest cpcb norms and as specified and also contractor shall submit test certificate of dg set as per latest cpcb norms. 63 summer appliances works 64 supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170v 250v with output voltage stabilized at 230v with accuracy of ±2.5% and of capacity 1.0 kva complete all as directed by engineer in charge. 65 supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170v 250v with output voltage stabilized at 230v with accuracy of ±2.5% and of capacity 2.0 kva complete all as directed by engineer in charge. 66 supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170v 250v with output voltage stabilized at 230v with accuracy of ±2.5% and of capacity 3.0 kva complete all as directed by engineer in charge. 67 supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 250v with output voltage stabilized at 230v with accuracy of ±2.5% and of capacity 5.0 kva complete all as directed by engineer in charge. 68 supply and installed refrigerators, electric driven (single phase) of capacity 220 ltrs frost free, 5 star rated complete all as directed by engineer in charge. 69 supply and installed refrigerators, electric driven (single phase) of capacity 400 ltrs frost free, 5 star rated complete all as directed by engineer in charge. 70 supply and installing desert cooler electric driven (single phase) having nominal air flow capacity of 4000 cum/ hrs 230v made of 20 gauge ms sheet and size not less than 90cm, 78cm x 78cm surface area from top and bottom 62cm x 54cm front grill size including tullu pump with rotary switch (4 speed) 5 amp switch on front side, drain valve including two coats synthetic of enamel paint over a coat of primer complete all as directed by engineer in charge. 71 rain water harvesting works 72 material and labour for gravel packing including jute as filter media 4mm to 6mm size around ms pipe complete all as directed by engineer in charge. 73 material and labour for filling of gravel in trenches of size 6mm to 10mm upto height of 0.50m complete all as directed by engineer in charge. 74 material and labour for filling of gravel in trenches of size 2mm to 4mm upto height of 1.0m complete all as directed by engineer in charge. 75 bore well works 76 material and labour for drilling of 675mm bore hole from ground level to 20 m depth below ground levelin any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes complete all as specified and as directed : notes :(a) record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) the bore/tube well should be constructed by the agency as approved by ge (east) fzr.(c) the rates also includes transportation of rig machine & t&p at site.(d) trail bore will be drilled, if sufficient wet strata is available then erw casing will be lowered. in case strata is not available payment only for drilling will be made 77 all as per srl item no. 11.01 here in before but from 20 m below ground level to 40 m depth below ground level. 78 all as per srl item no. 11.01 here in before but from 40 m below ground level to 60 m depth below ground level. 79 material and labour for drilling of 525 mm bore hole from 60 mtr below ground level to 85 mtr depth below ground level in any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes complete all as specified and as directed : notes :(a) record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) the bore/tube well should be constructed by the agency as approved by ge (east) fzr.(c) the rates also includes transportation of rig machine & t&p at site.(d) trail bore will be drilled, if sufficient wet strata is available then erw casing will be lowered. in case strata is not available payment only for drilling will be made 80 all as per srl item no. 11.04 here in before but from 85 m below ground level to 110 m depth below ground level. 81 all as per srl item no. 11.04 here in before but from 110 m below ground level to 135 m depth below ground level. 82 material and labour for drilling of 450 mm bore hole from 135 mtr below ground level to 160 mtr depth below ground level in any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes of following diameters complete all as specified and as directed : notes :(a) record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) the bore/tube well should be constructed by the agency as approved by ge (east) fzr.(c) the rates also includes transportation of rig machine & t&p at site.(d) trail bore will be drilled, if sufficient wet strata is available then erw casing will be lowered. in case strata is not available payment only for drilling will be made 83 all as per srl item no. 11.07 here in before but from 160 m below ground level to 185 m depth below ground level. 84 all as per srl item no. 11.07 here in before but from 185 m below ground level to 200 m depth below ground level. 85 material and labour for electrical logging of bore well and after electrical logging report of assembly design and submission of lithological log report for approval of ge complete. 86 supply and fixing 350 mm bore erw mild steel housing pipe 8mm wall thickness duly painted with primer and anti corrosive paint with screwed and socket ends in standard length of 3 metre or as required at site, complete with coupling, welding at joints as required (isi marked : is 4270 1992) including cutting,lowering, jointing and fixing in position, complete all as specified (measured net as fixed). 87 all as per srl item no. 11.11 here in before but 250 mm bore pipe with 8 mm wall thickness. 88 supply and fixing low carbon galvanised iron screen filter (slotted) 250mm bore pipe with slots 0.2 mm to 1.5 mm, 6.4mm wall thickness duly painted with ferrous primer and anti corrosive bituminous paint including screwed and socket ends in standard length, welding and fixing support having slots 0.2 mm to 1.5 mm depending upon nature of aquifers sediments, complete including lowering and fixing in position, confirming to is 4270 1992, complete all as specified (measured net as fixed) 89 supply and fixing mild steel reducing socket for connecting 350mm bore housing pipe with 250mm bore blind pipe with minimum 8.0 mm wall thickness including welding and fixing support complete all as specified and directed 90 supply and fixing mild steel bail plug suitable for 250 mm bore pipe 1.5 metre long having wall thickness of 8.0 mm with strong iron hooks, complete all as specified and directed 91 supply and fixing well cap fabricated out of 6 mm thick mild steel sheet for 350mm bore housing pipe threaded similar to housing pipe with handle made and of 20mm dia mild steel round bar, complete all as specified and directed 92 material and labour for mild steel flat iron 75mmx6mm as centre guides (set of three), standard pattern for 350/250 mm bore housing pipe complete all as specified and directed 93 material and labour for ms clamps made out of flat iron 125mmx12mm and 01 metre long with nut, bolts of 22mm dia of suitable length for 350mm bore housing pipe complete all as specified and directed 94 material and labour for mild steel structural steel e 250 grade 410w (ismb 150) fixed independently without connecting plateincluding two coats of black paint over a coat of red oxide complete all as specified and directed 95 material and labour for strata sample box, made out of 1st class soft wood (deodar) having appropriate internal dimensions 1000mm×600mm×100mm with open able glass shutter using 4mm thick plain sheet glass having pigeon holes as approved, 2 nos butt hinges of suitable size and 75mm long hasp staple 01 no having not less than 25 compartments capable of holding 480 to 540 grams of strata sample, including painting wooden surfaces with two coats of synthetic enamel paint (grey) over a coat of pink primer complete all as specified and as directed 96 material and labour for 10mm thick (structural steel should be fe 290 (grade e 165) mild steel black plate of size 600mm dia & cut into two semi circular equal parts with 350 mm dia hole in the centre complete all as directed by engineer in charge. 97 material and labour for pea gravel of size 1.5mm to 4.5mm packed all around 350mm bore housing pipe and 250mm bore blind pipe, strainer pipe upto entire depth as required at site in newbore well, complete all as specified and directed.note: for the purpose of measurement, gravel brought by the contractor shall be stacked properly at site & measurements of stack shall be carried out before use and after use(left unused) to arrive at the net qty of gravel used by the contractor in the work & payment against this item shall only be made for the qty of gravel used in the work not for the total qty of gravel brought. 98 material and labour for testing and developing the bore well by means of aircompressor5000 psitill sand free clear water discharge is obtained to achieve maximum yield of suitable capacity for first 24 hours running complete all as specified and directednote : all equipments shall be arranged by contractor athis own cost. 99 all as per srl item no. 11.23 here in before but beyond 24 rs. 100 material and labour for yield testing of the tube well by means of engine driven pumping set of suitable capacity, the discharge shall be measured by providing orifice system or ‘v’ notch fixed to steel tank of adequatecapacity complete all as directed by engineer in charge. note : all equipments arranged by contractor at his cost & rates are deemed to be included in quoted rates. 101 testing portability of water by chemical analysis such as ph value, dissolved solids, hardness as caco3 and calcium, magnesium, chlorides, sulphate, nitrate, alkality, iron turbidity ntu, mineral oil, colour hazen units, taste, odour, residual free chlorine, total coliform per 100mm (microbiological test) and e coli as per 100ml (microbiological test) as well as bacteriological portability from any govt lab complete all as directed by engineer in charge. 102 supply, installation, commissioningand testing of submersible pump set v 8multistage (as per mfg design stage ( min 4 stage)) electric driven 2900 rpm of capacity not less than 780 lpm at not less than 90mtr head water lubricated suitable for 200/250mm bore and 150 mm dia discharge pipe coupled with squirrel cage induction electric motor 3 phase 415 volts of capacity not less than 30 hp having ci casing & gun metal impeller fitted with delivery pipe etc as reqd at sitewith suitableelectric motor, b class insulation, ip 68 protection and electric connection with following moc: stainless steel impeller, stainless steel pump shaft, ltb pump bushes, cast iron bowl/stage casing; complete all as directed by engineer in charge. 103 supply and fixing flat submersible cable pvc multi stranded copper conductor 3 core 16 sqmm from lt panel/ star delta starter to pump motors complete all as directed by engineer in charge. 104 supply and fixing mild steel columnpipe heavy duty5.4 mm wallthickness 100 mm dia in 3 m length includingflanged both side including provision of nuts, bolts, gasket etc including lowering and fixing complete all as directed by engineer in charge. 105 supply, installation, testing and commissioning in replacement of cpri approved, factory made, lt panel board cubical, indoor type, floor mounted double door, suitable for ac, 3 phase 4 wire, 50 cycles, 415 volts,front & rear openable double door with locking arrangement. the panel board shall be made of 2.0 mm thick crca/ms sheet (min size 1.2 m x 1.0 m x 0.45 m) with synthetic enamel paint both side.the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm ,gaskets thimbles including cable entry glands, all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl& 1/2 mtr for below gl in pcc (1:3:6) type c 2 using 40 mm stone aggregatescomprising of following: (i) panel having common aluminium bus bar of capacity 400 amp tpn each ( size 40mm x10 mm) and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size(ii) incoming(a) (a) mccb adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 200 amp 4 pole icu= 36 ka with overload variation 40 100% 01 no(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 100 amp 4 pole icu = ics = 16 ka 01 no.make : abb/siemens/schneider.(outgoing)(b) mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole icu = ics = 16 ka 01 no.make : abb/siemens/schneider.(outgoing)(c) mcb tpn 63 amps 01 nos(d) on load change over switch 200 amps 01 no(e) automatic star delta submersible starter dlx (with short circuit protection) hgs series suitable for 30 35 hp motor provided with protection degree ip 54 and frls internal wiring and extended wide bend coil and in built metering and contactor size is mn 50 and overload relay range 28 a 40 a and tp mcb rating 100 amps and starter should be provided with single phase preventer etc all as directed.(iv) volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no(v) ammeter 0 200 amps digital type square shape 96mm flush mounted with selector switch and cts 200/5 a 1 no.(vi) indicator lamp ryb : 01 set, with suitable ct coil complete 106 supply, installation and testing of heavy duty chemical dosing system plunger type suitable to inject solution upto 25 lph, working pressure 10 kg /cm square comprising dosing pump coupled with three phase electric motor of capacity 0.5 hp,1440 rpm assembled with agitator in one motor , agitator with ss sweep blade duly frp coated, frp tank 150 ltrs capacity, complete unit mounted on heavy duty panited with ms fabricated frame duly anticorrosive paint, with chemical grade pvc nrv including inlet /outlet check valve all connections ,connecting cpvc/upvc/pvc fittings ,pipe etc complete all as required at site and as directed by engineer in charge. 107 stp works 108 design, supply, construction, installation, testing & commissioning of sewage treatment plant 100 kld based on principle of aerobic attached growth non clogging randomly moving bed bio reactor (mbbr) prefab type, including required foundations and & covering of all motors with ms sheets covers & the following : (a) one no. fine bar screen chamber fitted with screen of ms epoxy construction as per given minimum specifications, to be installed in fine barscreen chambers, provided at an angle of 60° to prevent floating objectspassing through it and subsequently removing manually and dumped forfurther disposal(b) one no. oil & grease removal chamber in rcc construction with design mix concrete of grade m 30, for removal of free floating oil & grease in the sewage, as per given specifications(c) one no. equalisation tank in rcc construction with design mix concrete of grade m 30, as per given specifications, to cater for the peak discharge including provision of diffused air to ensure that septic conditions do notoccur in tank at all. one lot of air grid for equalization tank for providingaeration in the tank, as specified in ps.(d) two nos. raw sewage pumps complete with motor and all necessaryaccessories and fittings, to be installed for transferring sewage fromequalization tank to process reactor. level sensor should be provided in the tank and interlinked with pumps for on off operation as per water level in the tank. one pressure gauge for each pump has to be provided to measure pressure at the outlet.(e) two nos. air blower complete with motor and all necessary accessoriesupply and fixingittings, for providing air in equalization tank, mbbr reactors & sludge holding tank. one no. air rotameter is to be provided in each line to mbbr reactor 1 & 2, & eqt for measurement of quantity of air.(f) one lot of anoxic chamber in msep construction with internals comprising of media and msep mixer. 109 (g) two lot of mbbr tank in msep construction with internals comprising of media, ss air grid & ss rise pipe, media retaining sieves, etc.(h) one lot of tube settler tank in msep construction with internals comprising of media, supporting structure & collection trough.(j) two nos. sewage centrifugal mono block self priming recirculation pumps complete with motor and all necessary accessories and fittings. one pressure gauge for each pump is provided to measure pressure at the outlet.(k) one no. chlorine contact cum filter feed tank in in msep construction, as per given specifications. with one set of chlorine dosing system comprising of solution tank and dosing pumps, as specified in ps, with necessary connection for dosing of solution in chlorine contact tank.(l) two nos. filter feed centrifugal monobloc pumps complete with motor and all necessary accessories and fittings for feeding tertiary unit, level sensor should be provided in the chlorine contact cum filter feed tank andinterlinked with pumps for on off operation as per level in the sump. onepressure gauge for each pump is provided to measure pressure at theoutlet(m) one no. dual media filter, complete with media, frontal piping, valve andpressure gauges to measure pressure across the filter.(n) one no. activated carbon filter of, complete with media, frontal piping, valve and pressure gauges to measure pressure across the filter(o) one no. treated water tank in msep construction, to receive supernatant coming from tertiary treatment plant, as per given specifications(p) two nos. sludge transfer self priming mono block pumps complete with motor and all necessary accessories and fittings. one pressure gauge for each pump has to be provided to measure pressure at the outlet 110 (q) one no. continuous feed sludge screw press with dosing system for sludge dewatering system as specified in ps(r) one no. mcc panel for operation of all electromechanical units of sewage treatment plant(s) one lot of suitable size piping & valves of suitable material to interconnect various units as per site layout.(t) one lot of power & control cables to interconnect various drives and instrumentations with stp panel.(u) one lot of foundations in pcc for all e&m equipment, as required.note :the prices for design, supply,construction, installation, testing and commissioning of 100 kldstp based on mbbr technologyincluding all civil, electromechanical andinstrumentation works as per thespecifications given in technical specification including requiredfoundations. 111 supply and fixing of non clog centrifugal sewage pump having 20 mtr head, capable of delivering approx. 937.5 lpm at 20 mtr head with 10 hp ac electric motor 3 phase, 415v, 50c/s, 1450rpm directly coupled on a common base frame complete all as directed by engineer in charge. make: kirloskar/ ksb/ crompton 112 supply and fixing cast iron foot valve flanged end conforming to is 4038 pn 0.2, 100 mm (4”) dia size all as specified and directed 113 supply, installation, testing and commissioning in replacement of cpri approved, factory made, lt panel board cubical, indoor type, floor mounted double door, suitable for ac, 3 phase 4 wire, 50 cycles, 415 volts,front & rear openable double door with locking arrangement. the panel board shall be made of 2.0 mm thick crca/ms sheet (min size 1.2 m x 1.0 m x 0.45 m) painted with synthetic enamel paint both side.the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm, gaskets thimbles including cable entry glands, all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl& 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregatescomprising of following: (i) panel having common aluminium bus bar of capacity 400 amp tpn each ( size 40mm x10 mm) and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size(ii) incoming(a) mccb adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 100 amp 4 pole icu= 16 ka with overload variation 40 100% 01 no(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole icu = ics = 16 ka 02 nos (c) mcb spn 32 amps 01 no(d) on load change over switch 100 amps 01 no(e) automatic star delta submersible starter asd (with short circuit protection) hsg series suitable for 10 12.5 hpmotor provided with protection degree ip 54 and frls internal wiring and extended wide bend coil and in built metering and contactor size 18 and overload relay range 8 a 12 a and class h insulation and starter should be provided with single phase preventer etc all as directed.(iv) volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no(v) ammeter 0 200 amps digital type square shape 96mm flush mounted with selector switch and cts 200/5 a 1 no.(vi) indicator lamp ryb :01 set. with suitable ct coil complete 114 outsourcing of manning / operation & routine periodical maintenance of electro mechanical equipment’s, control valves, instrumentals etc of stp 100 cum/day (for two shifts per day including sunday & holiday, by employing one fgm (semi skilled operator) and one helper per shift (each shift of eight hours) and maintaining desired level of bod/cod, tss, tkn by dosing of required quantity of chemicals as per oem recommendation complete for a period of 11 months starting from the next day of certified date of completion of phase i (to be intimated by ge through work order separately) complete all as specified and directed.note : (a) maintenance of log sheet and all maintenance records shall be responsibility of the contractor and no stationary shall be provided by the department. format of log sheet and records etc shall be decided by ge/ engineer in charge(b) the contractor is responsible to maintain the installations and surrounding area in presentable manner through out the period. the shift timings shall be decided by engineer in charge and liable to change as and when required by engineer incharge.(c) area cleaning surrounding the plant room & inside the plant room etc shall be responsibility of the contractor (d)the contractor shall be maintain clear record of attendance for workmen/ staff. (e) consumables i.e grease, lubricant oil, cotton waste washers etc required for routine maintenance of stp shall be provided by contractor and cost of the same shall be deemed to be included in unit rates quoted.(f) cost of stationary required for attendance register, meter readings, site order books, log sheets etc shall be provided by contractor and cost of same shall be deemed to be included in unit rates quoted by contractor.(g) fgm/ operator should be iti qualified in respective trade i.e. electrical/ fitter and having minimum 2 years experience in similar trade/ works.(h) helper should be having 2 years experience in similar trade(j) timing of shift shall be as decided by engineer in charge and as specified . 115 treated sewage water supply works 116 supply and fixing 3 phase horizontal, radially split volute casing centrifugal pump 3 hp in back pull out design, single stage, single entry with radial impeller equipped with vfd devices & equipped with speed control panel to control speed/ discharge pump set capacity of discharge 500 lpm at delivery head of 22mtr of ie 3* & with moc material ci/ bronze with suitable electrical panel, cable & starter complete all as directed by engineer in charge. 117 supply and fixing motor starter for 3 hp pumping sets, centrifugal, electric driven having extended wide bend, coil, frls internal wiring, providing with protection degree ip 54, starter type air break, class h insulation complete all as directed by engineer in charge. 118 supply and fixing ppr gate valves (brass insert) of 160mm bore complete all as specified and directed 119 supply and fixing ppr gate valves (brass insert) of 75mm bore complete all as specified and directed 120 supply and fixing cast iron air valve with single air outlets, conforming to is : 14845 of size 50mm bore and fixing up in cast iron water supply mains of size 100mm bore complete all as specified and directed 121 supply and fixing cast iron air valve with single air outlets, conforming to is : 14845 of size 50mm dia and fixing up in cast iron water supply mains of size 150mm dia complete all as specified and directed ...

Military Engineer Services - Punjab

28487820 provision of sainik institute at patiala 1 total amount of sch a sec i ( building works ) lump sum price worked out by the contractor for building works as listed in schedule a part i 2 total amount of sch a sec ii ( site clearance & earth works ) lump sum price worked out by the contractor for site clearance & earth works as listed in schedule a part ii 3 total amount of sch a sec iii ( internal electrification works ) lump sum price worked out by the contractor for building works as listed in schedule a part iii 4 total amount of sch a sec iv ( internal water supply works ) lump sum price worked out by the contractor for internal water supply works as listed in schedule a part iv 5 total amount of sch a sec v ( sewage disposal works ) lump sum price worked out by the contractor for sewage disposal works as listed in schedule a part v 6 total amount of sch a sec vi ( area drainage works ) lump sum price worked out by the contractor for area drainage works as listed in schedule a part vi 7 total amount of sch a sec vii ( road / path / culvert works ) lump sum price worked out by the contractor for road / path / culvert works as listed in schedule a part vii 8 total amount of sch a sec viii ( security wall / fencing works ) lump sum price worked out by the contractor for security wall / fencing works as listed in schedule a part viii 9 total amount of sch a sec ix ( external electrification works ) lump sum price worked out by the contractor for external electrification works as listed in schedule a part ix. 10 total amount of sch a sec x ( external water supply works ) lump sum price worked out by the contractor for external water supply works as listed in schedule a part x. 11 total amount of sch a sec xi ( summer appliances works ) lump sum price worked out by the contractor for summer appliances works as listed in schedule a part xi. 12 total amount of sch a sec xii ( open platform works ) lump sum price worked out by the contractor for open platform works as listed in schedule a part xiii. 13 schedule asection xiii ( misc items of works ) note : this schedule is not pre priced by mes and the pre priced rate indicated as rs 0.00 under col. 5 siginifies this fact only. 14 internal electric supply works 15 item no. 1 :m& l point wiring complete with 1.5 sqmm ( nominal area ) pvc insulated unsheathed multistranded copper condutor single core cable 1100 volts grade frlsh isi marked drawn through and including heavy duty non metalic pvc conduit, isi marked of not less than 20 mm dia, concealed in wall, roof, etc, with all connected fittings, etc. suitable for mounting modular switches, sockets etc and including frlsh pvc insulated unsheathed multistranded single core copper conductor cable of size 1.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed for the following: nnote: switches , sockets, ceiling rose, regulators, modular metal boxes, cover plate etc shall be measured and paid separately. 16 ( a ) one light / fan / bell point controlled by one switch 17 ( b ) one 5 pin socket outlet independent 5 / 6 amps 18 ( c ) one socket outlet 5 / 6 amps on the same board with other switches. 19 ( d ) one 6 pin 6 / 16 amps socket outlet independent with 2.5 sqmm size copper conductor cable and 1.5 sqmm copper cables as earth wire. 20 item no 2: m& l point wiring complete with 2.5 sqmm ( nominal area ) pvc insulated unsheathed multistranded copper condutor single core cable 1100 volts grade frlsh isi marked drawn through and including heavy duty non metalic pvc conduit, isi marked of not less than 20 mm dia, concealed in wall, roof, etc, two light controlled by one switch with all connected fittings, suitable for mounting modular switches, sockets etc and including frlsh pvc insulated unsheathed multistranded single core copper conductor cable of size 2.5 sq mm green in colour as in earth continuity conductor connected to common earth dolly and all metal parts of fittings as specified and directed. nnote: switches , sockets, ceiling rose, regulators mosular metal boxes, cover plates etc shall be measured and paid separately. 21 item no 3: s&f white cover plate with frame 12 module 240 volts andcomplete all as specified and directed by the engr in charge. 22 item no 4: s&f modular metal box 8 module and complete all as specified and directed by the engr in charge. 23 item no 5: s&f modular metal box 12 module and complete all as specified and directed by the engr in charge. 24 item no 6: supply and fixing modular angle holder cat pat no 33958 of anchor or equivalent makes with insulated body with back plate for led lamps all as specified and directed by the engr in charge. 25 item no 7: supply and fixing led downlighter 9 watt, retrofit all as specified and directed by engr in charge. 26 item no 8: s&f led tube light fittings 1 x 18 w, 230v, complete with all accessories internally prewired and including connecting up with twisted flexible pvc copper conductor cable of 23 / 0.0076 from ceiling rose all as directed by engr in charge. 27 item no. 9: s&f of double door three phase distribution board 6 way made out of crca sheets 1.6 mm thick, phosphatised powder coated with copper bus bar 200 amps, 415 v, earth stud, din rail, polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box , ground terminal blocks , duly wired with thimbled flame retardant copper conductors and poly layer for protection in all as specified and directed. ( note: single phase mcbs are to be measured and paid for seperately ) n 28 item no. 10: s&f sheet metal enclosure mccb tpn distribution board, double door, ip 43 class, including suitable size copper bus bar, 415v, 4 way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. 29 item no. 11: supply and fixing in replacement isolator 40 amps, 10 ka, c series 240 v isi marked complete all as specified and directed by engr in charge. 30 item no. 12: s&f for flush fixing of sheet metal enclosure mcb spn distribution board, double door, ip 43 class, including suitable size copper bus bar, 240v, 12 way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. n 31 item no. 13: s&f for flush fixing of sheet metal enclosure mcb spn distribution board, double door, ip 43 class, including suitable size copper bus bar, 240v, 6 way with shrouded neutral bar, earth bar and incld. cable ties and suitable size blanks, including taking down of existing sheet metal enclosure complete all as specified and directed. n 32 item no. 14 : supply and fixing mcb tpn 63 amps, 10 ka c series 240 v isi marked.complete all as specified and directed by engr in charge. 33 item no 15: supply and fixing thermal magnetic adjustable type mccb 125 amps , 16 ka, c series 415. v isi marked.complete all as specified and directed by engr in charge. 34 item no 16 : supply and fixing cable pvc, 2 single core 2.5 sq mm stranded aluminium conductor, 1100 volts grade heavy duty unarmoured 35 item no 17 : supply and fixing mirror light fitting led 10w, 230 v, 2ft all as per crompton make cat no. lcl 14 cdl or equivalent makes mentioned in tender documents, complete all as specified and directed by engr in charge. 36 item no 18 : s&f led building security light, pressure die cast aluminum housing, 25 watts capacity, 240v, ip 65 class, with suitable in built electronic driver complete incld. fixed on a bracket made out of 1.5 mtr long med grade gi pipe 40 mm dia bend to shape as directed fitted on wall at a height not less than 6 mtr from ground with ms clamp, nuts and bolts and washers as required at site and incld. connecting luminarie to the nearest ceiling rose / junction box with 1.5 sqmm pvc insulated 3 core wire complete all as directed and specified by engr in charge of make crompton greaves or equivalent in philips / wipro. note cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 37 item no 19 : suppy and fixing exhaust fan heavy duty with louvers of size 380mm sweep, 900 rpm 230 volts single phase ac supply complete with, bolt, nuts and washers, suitably embedded in the wall including making suitable opening and provisioning of flexible cord copper of size 23 / 0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed by engineer in charge. 38 item no 20 : supply only sheet metal enclosure with socket plug top and mcb sp cap 20 amps with a 2 pin, earth plug and socket complete all as specified and directed by engr in charge. 39 item no 21 : supply and fixing in light fitting led panel 25 w, 230 v, round type surface mounted, injection molded in thermally conductive engineered plastic fr v0 grade housing, diffuser with high optically efficient material all as per crompton cat part no.: lcrp 20 cdl or equivalent model of makes mentioned in tender documents, complete all as specified and directed by engr in charge. 40 item no 22 : supply and fixing in light fitting led panel 36 w, 230 v, round type surface mounted, injection molded in thermally conductive engineered plastic fr v0 grade housing, diffuser with high optically efficient material all as per crompton cat no.: lcrp 20 cdl make or equivalent or equivalent makes mentioned in tender documents, complete all as specified and directed by engr in charge. 41 item no 23 : supply and fixing of 100w led flood light with system lumen efficacy=100 lm / w operating voltage between 140 270vac, driver will comply for 440vac operation ( will sustain for 4 6 hrs continuously ) , driver will have cut off at > 300 vac, power factor more than 0.95%, led cct 5665±355k as per ansi bin, led driving current < 70% of rated maximum forward current, luminaire intergal driver with 5kv surge protection, over load protection, no load protection and bis marking ( r no. for driver ) , driver certiifcation iec64347 2 13 is ( 15885 ) , driver should be concealed under ip66, over all electrical efficency more than 90%, driver electrical efficiency will be > 85% connecting with pvc copper cable of size 3x1 sqmm as per is 10322 at complete all as specified and directed. 42 item no 24 : supply and fixing of 60w led high bay light with surface mounted device ( smd ) with multiple led with borosilicate glass lens and acrylic, with aluminum reflector, operating voltage between 140 270vac, power factor more than 0.95%, intergal driver with 5kv surge protection differential mode / coman mode , led cct 5665±355k as per ansi bin, over load protection, no load protection, driver should be concealed under ip66 and bis marking ( r no. for driver ) , driver certiifcation iec64347 2 13 is ( 15885 ) , system lumen >15000, cri>70, over all electrical efficency more than 90%, connecting with pvc copper cable of size 3x1 sqmm complete all as specified and directed. 43 item no 25 : supply, installation, connecting and testing of ceiling fan electric single phase 230 volts ac of sweep 1200mm having service value more than 4, complete with mounting arrangment in ceiling such as down rod 600mm, hooks, clamps, nuts, bolts and washers etc complete all as specified and directed. 44 item no 26 : material and labour for ceiling rose surface type, 65mm x 50mm two to three terminals / pvc / polycarbonate, isolated body fixed on pvc block complete all as specified and directed. 45 item no 27 : supply and fix of mcb sp 6 32 amp 230v complete all as specified and directed. 46 item no 28 : material and labour for call bell ding dong ac 230 volt single pole complete all as specified and directed. 47 item no 29 : supply and fix environmental friendly, ultra modern, energy saving, surface mounted, decorative stud bulk head edge lit led luminaire comprising of high brightness leds of capacity 10 watts complete all as specified and directed. 48 road, path & culverts 49 item no 30 : delinators of size 700x100x50mm of abs round body fixed with 100mm dia highly reflective reflector, duly uv stablized, in yellow colour complete all as specified. 50 item no. 31: cat eye two way reflective of size 100 x 100 x 18.5mm with pvc body with reflective panels amber / red / white complete all as specified and directed. 51 item no. 32: supply only sand for sand cusioning under interlocking paver block complete all as specified and directed. 52 item no. 33 : m&l bringing approved earth from outside md land including cost of earth & carriage complete all as specified and directed. 53 item no. 34 :painting lines, dashes, arrows, letters etc on road pavement and the like not exceeding 10 cm wide with thermo plastic paint . 54 item no. 35 :painting lines, dashes, arrows, letters etc on road pavement and the like exceeding 10 cm wide with thermo plastic paint. 55 item no.36 : providing, laying, compaction of granular sub base by providing close graded material conforming to specifications i.e grading ii, conforming to clause 401 of mort&h specifications for road and bridge works ( fifth revision ) , mixing in a mechanical mix plant at omc, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller of capacity 8 to 12 tonne to achieve the desired density, 150 mm thick compacted thickness, complete all as specified and directed by engr in charge. 56 item no. 37 : providing, laying, compaction of wet mix macadam conforming to clause 406 of mort&h specifications for road and bridge works ( fifth revision ) , 250 mm thick ( compacted thickness, 125 mm thick in two separate layers ) with mechanically crushed graded stone aggregates and granular material ( size range 53 mm to 0.075 mm ) , grading of aggregates as per table 400 13 of mort&h specifications for road and bridge works ( fifth revision ) , including premixing the material with water at omc in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub base / base course on well prepared surface and compacting with vibratory roller of 8 to 12 tonne capacity to achieve the desired density , required gradient and camber etc., complete all as specified and directed by engineer in charge. nnotes: n1. the wmm shall be laid in two layers i.e each layer of 125 mm thick ( compacted thickness ) . n2. for payment purpose, both layers shall be considered as one unit. 57 item no 38 : preparation of un surfaced wet mix macadam ( wmm ) surfaces by brushing with wire brushes for re moving caked mud , dust, loose material, foreign material etc., sweeping with power brooms and finally fanning the cleaned surface with air compressors to remove all loose dirt etc. and applying evenly a priming coat on un surfaced wet mix macadam surfaces conforming to clause 502 of mort&h specifications for road and bridge works ( fifth revision ) , with cationic bituminous emulsion ss1 grade, confirming to is 8887 ( latest edition ) @ 7.5 kg per 10 sq metres using primer distributor which shall be self propelled or towed bitumen pressure sprayer complete all as specified and directed by engineer in charge. n 58 item no. 39 : providing, laying & compaction of bituminous macadam ( bm ) 50 mm compacted thickness conforming to clause 504 of mort&h specifications for road and bridge works ( fifth revision ) , using mechanically crushed stone aggregates and granual material etc. of grading ii as per table 500 7 of mort&h specifications for road and bridge works ( fifth revision ) , premixed with bituminous binder, bitumen grade vg 30 @ 3.50% ( percentage by weight of total mix ) prepared in batch type hot mix plant of 100 120 tph capacity transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density complete all as specified and directed by engineer in charge. nnotes : ( i ) the contractor shall quote the rate against item considering 3.5% vg 30 bitumen content. job mix formula as per mort&h specifications for road and bridge work ( fifth revision ) for bituminous concrete shall be got designed from nit / ctl / govt engg college and shall be got approved from ge in writing well before commencement of work without any financial effect to the department. also the bitumen content shall not be less 3.4% by weight of total mix as per clause 504.2.4 of mort&h specifications ( fifth revision ) . n ( ii ) if qty of binder contents is less than the qty as specified in respective items of boq, it shall be adjusted at supply only rates of paving bitumen @ rs 45.00 per kg and if qty of binder contents is more than the qty as specified in respective items of boq no adjustment shall be made. 59 item no. 40 : preparation of surfaces and applying evenly a tack coat conforming to clause 503 of mort&h specifications for road and bridge works ( fifth revision ) , with cationic bituminous emulsion rs1 grade, confirming to is 8887 ( latest edition ) @ 2.5 kg per 10 sq metres using using primer distributor which shall be self propelled or towed bitumen pressure sprayer complete all as specified and directed by engineer in charge. n 60 item no. 41 : preparation of existing black top surfaces and applying evenly a tack coat conforming to clause 503 of mort&h specifications for road and bridge works ( fifth revision ) , with cationic bituminous emulsion rs1 grade, confirming to is 8887 ( latest edition ) @ 2.5 kg per 10 sq metres using using primer distributor which shall be self propelled or towed bitumen pressure sprayer complete all as specified and directed by engineer in charge. 61 item no. 42 : providing and laying 30 mm thick ( consolidated thickness ) bituminous concrete ( bc ) layer conforming to clause 507 of mort&h specifications for road and bridge work ( fifth revision ) including cost of coarse aggregates, fine aggregates, filler, 5.5% binder ( paving bitumen grade vg 30 ) content by weight of total mix and crushed aggregates of grading 2, anti stripping agent, warm mix additives ( quantity, quality and grade as per the approved job mix formula ) etc, cleaning and pre heating of the mineral aggregate, filler & bitumen to the specific temperature, thoroughly mixing with binder of specified bitumen content, anti stripping agent, warm mix additives as per mix design in hot mix plant of 100 120 tph capacity, carrying the hot mixed materials by means of tipper, trucks, or any other approved and suitable arrangements, laying the hot premixed materials over the prepared surface by means of paver finisher including manual operation as and when required for proper grade, level and camber thorough rolling with power roller 8 to 12 tonnes smooth wheeled, vibratory and tandem roller with necessary hand packing and pinning to give an even surface, including running expense of all plants and machineries, inclusive of proper traffic control during laying to the satisfaction of engineer in charge, required quality control tests at required interval etc complete in all respects complete all as specified and directed by engr in charge. n n n 62 ( item no 42 contd..... ) notes : ( i ) the contractor shall quote the rate against item considering 5.5% vg 30 bitumen content. job mix formula as per clause no 505.3.3 of mort&h specifications for road and bridge work ( fifth revision ) for bituminous concrete shall be got designed from nit / ctl / govt engg college and shall be got approved from ge in writing well before commencement of work without any financial effect to the department. also the bitumen content shall not be less 5.4% by weight of total mix as per clause 507.2.5 of mort&h specifications ( fifth revision ) . n ( ii ) the cost of materials, transportation, job mix formula from lab and testing charges for various tests as required are included in the unit rate quoted by the contractor. n ( iii ) cost of filler i.e rock dust, hydrated lime or cement is deemed to be included in unit rate. n ( iv ) if qty of binder contents is less than the qty as specified in respective items of boq, it shall be adjusted at supply only rates of paving bitumen @ rs 45.00 per kg and if qty of binder contents is more than the qty as specified in respective items of boq no adjustment shall be made. n ( v ) after spreading of mix as per clause 507.4.7 of mort&h specifications entire surface during the operation shall be rolled with road roller 8 10 tonnes ( smooth wheeled ) followed with vibratory road roller of 8 10 tonnes static weight, followed by finish rolling with 6 to 8 tonnes smoooth wheeled tandem roller as per clause no 507.4.8 of mort&h specifications ( fifth revision ) and the cost of the same shall be deemed to be included in the quoted rate. n n 63 air conditioning 64 item no. 43: supply, install, testing and commissioning of install air cooled spilt type air conditioners electric driven ( 240 volts, single phase, 50 hz supply ) with energy efficient scroll compressor, working on r 134 a or superior environment friendly refrigerant, cordless remote operated, comprising of indoor unit, wall mounted, material of construction of indoor unit abs, power consumption ( max ) 4000 watts, outdoor unit, powder coated, integral refregerant piping, electric connection ( between indoor and outdoor unit located up to a maximum distance of 10 meters ) and condensate water drainage arrangement etc pressore testing, leak testing, vaccumisation, r 134a gas charging, shifting of indoor and outdoor unit, mounting arrangement of indoor unit with anchor fastner, support rod, vibration isolators complete of following capacity or nearest higher standard size complete of following capacity: 4500 k cal per hour ( 1.5 ton ) .bee 5 star rated complete all as specified & directed. 65 item no:44 : supply, install, testing and commissioning of install air cooled spilt type air conditioners electric driven ( 240 volts, single phase, 50 hz supply ) with energy efficient scroll compressor, working on r 34a or superior environment friendly refrigerant, cordless remote operated, comprising of indoor unit, wall mounted, material of construction of indoor unit abs, power consumption ( max ) 4000 watts, outdoor unit, powder coated, integral refregerant piping, electric connection ( between indoor and outdoor unit located up to a maximum distance of 10 meters ) and condensate water drainage arrangement etc pressore testing, leak testing, vaccumisation, r 134a gas charging, shifting of indoor and outdoor unit, mounting arrangement of indoor unit with anchor fastner, support rod, vibration isolators complete of following capacity or nearest higher standard size complete of following capacity 6000 k cal per hour ( 2 ton ) .bee 3 star rated all as specified and directred by eng in charge. 66 item no 45 voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stablilized at 230 v with accuracy of 2.5% and of following capacity complete all as specified & directed. 67 ( a ) 4.0 kva 68 ( a ) 5.0 kva 69 summer appliances 70 item no. 46 : supply and installation of desert cooler with outer body made of pgi ( plain galvanised iron ) sheet not less than 1.20 mm thickness for fixed part , thickness of pgi sheet for shutter not less than 0.80 mm thick, front grill made of pgi sheet with minimum weight 2.80 kgs. overall outer size not less than 66 cm x 66 cm x 99 cm ( height ) , electric driven copper wounded fan motor having nominal air flow capacity 4000 cum per hour and submersible pump for required flow of water ( sigle phase ) , complete all as specified & directed. 71 item no. 47: voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stablilized at 230 v with accuracy of 2.5% and of capacity 2 kva complete all as specified & directed. 72 item no. 48: supply and installed regrigerators, electric driven ( single phase ) , capacity 215 litres frost free complete all as specified & directed. 73 item no. 49 : supply and installed deep freezer hard top 320 ltrs capacity having double door complete all as specified and directed by eic 74 item no.50 : m&l for heavy duty pvc stands for placing / staging of water coolers and refrigirators of proper sizes complete all as specified & directed. 75 item no. 51 : supply and installed desert cooler electric driven ( single phase ) , having nominal air flow capcity of 4000 cum per hour complete all as specified & directed.. 76 external electrification 77 item no.52 : supply and laying sub class ‘b’ old size bricks laid adjacent to each other perpendicular to the direction of cable in trenches for protection of cable all as specified and directed. 78 item no. 53 : earthing complete with galvanised steel earth plate electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metre below ground level connected with earthing 32 x 6 mm strip galvanised iron of earthinglead all as shown in plate no. 02 to the earthing test point all as specified and indicted including testing on completion complete all as directed. ( cost of 7.5mm length of gi protection pipe shall be included in the rate of thid item. 79 item no. 54 : m&l for ms junction box made out of 2 mm thick sheet of size 300mm x 250mm x200 mm including aluminium busbar single phase with neutral of 63 amp capacity with , mcb sp 10 amp 01 nos for incoming and out going connections including necessary welding work, clamps and mounting on poles etc complete all as specefied and directed. 80 item no. 55 : s&f led street light ip 66 powder coated pressure die cast aluminium compact high power led street light fitting 25 watts with heat resistant toughned glass complete with all accessoreis watts. make: polycabpub05007 or equivalent or equivalent makes mentioned in tender documents complete all as specefied and directed. 81 item no. 56 : s & f brackets for street light lumanaries 40 mm light grade gi pipe with 2 nos clamps etc length of gi pipe not more than 1.5 metre length. ( for fixing on poles ) 82 item no. 57 : supply, levelling and well ramming sand cushioning in trenches for cable protection complete all as speified and as directed. note : thickness of sand cushioning after punning down shall be measured for payment purpose. 83 item no. 48 : item no.6 : cable ( with approved colour coding as per is ) with single core frls pvc insulated flexible multistranded copper conductor 1.1 kv grade for security light fitting ( main cable : number of runs indicated below ) along with one run of single core frls pvc insulated flexible multistranded copper conductor 1.1 kv grade for earthing in and including pvc conduits of suitable size, for 2 runs of 2.5 sqmm main cable + 1 run of 1.5 sqmm. 84 item no.58 : cable ( with approved colour coading as per is ) with single core frls pvc insulated flexible multistranded copper conductor 1.1 kv grade for security light fitting ( main cable : number of runs indicated below ) along with one run of single core frls pvc insulated flexible multistranded copper conductor 1.1 kv grade for earthing in and including pvc conduits of suitable size, for 2 runs of 2.5 sqmm main cable + 1 run of 1.5 sqmm. 85 item no. 59 : supply , installation, commissionning and testing of out door lt panel board made out of crca sheet 3.15 mm thick vermin proof factory made with angle and aluminium bus bar of capacity 200 amps for 3 phase and neutral with nessary angle iron 50 x 6 mm support frame including two coats powder painting over a coat of red oxide primer and grout in pcc complete all as specified and directed comprising of the following : nincoming n ( a ) aluminium bus bar of capacity 200 amps for 3 phase with neutral one job n ( b ) mccb 415 v, 100 a, 4 pole with over load , short circuit and earth fault protection with earth module breaking capacity 25 ka 01 nos. n ( c ) digital votl meter 0 500 volts square flush mounted with inbuild selector switch 01 nos. n ( d ) digital ampere meter square flush mounted with inbuild selector switch 01 nos n ( e ) indicator lamps ryb led type 01 set of three. ( e ) ct coils 100 / 5 a 03 nos. nout going n ( a ) mccb 63 a, 415v , 3 pole with over load short circuit protection, breaking capacity 16 ka 03 nos ( 2+1 ) n ( b ) mcb 20 a, 230v , 2 pole with over load short circuit protection, breaking capacity 10 ka 01 nos n nnote : ( i ) all mccbs / instruments / mcbs / bus bar shall be housed in a separate housing with on off latches in the housing. ( location sainik institute ) 86 external water supply 87 item no. 60 : m & l for cutting of exiting 150 mm dia ci / di / gi pipe line and including insert t of 50 mm dia branch pipe including complete earth work end joint as specified & directed. 88 item no. 61 : m&l for construction of brick masonry valve pit of size 900 x 900 x 900 mm ( internal dimension ) one brick thick wall in cm 1:4 on 100mm thick pcc 1:4:8 type d 2 ( 40mm graded aggregate ) as in foundation, and 15mm thick rendering in cement mortar ( 1:4 ) internally, externally up to 15cm below gl, providing valve pit cover made of 3mm thick ms sheet / plate, welded including provision of hinges, handle and locking arrangement including 40 x 40 x 6mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in pcc block 1:2:4 type b 1 ( 20mm graded aggregate ) of size 230 x 200 x 100mm, including two coats of anti corrosive paint over a coat of red oxide zinc chrome primer and necessary earth work in soft / loose soil complete all as specified & directed....

Military Engineer Services - Punjab

24445240 repair of submersible pump installed at amn dump barsat ge ( n ) patiala , repair of submersible pump to include the following services : ( a ) disconnecting the electric connections of submersible pumping set of capacity of 40 hp from panel board and taking down complete pump set with electric motor and column pipes manually/mechanically , dismantling pump from motor reconditioning the pump set and lowering after repairs as specified and directed by engineer in charge & testing . 01 each jobnote : the parts to be replaced and repairs as required and ordered by engineer in charge shall be paid separately under respective items here in after . , ( b ) transportation the submersible pumping set from pump house to workshop and back , dismantling the pump and replacing unserviceable parts i . e impellors , bushes , sleeves , shaft and neck ring , rubber bushes ec bringing back to site duly painted with anti corrosive paint all as directed by engineer in charge 01 each jobnote : spares such as impellors , shaft , bushes , thrust plates , sleeves , neck ring , rubber bushes etc will be paid under respective items . however the cost of fixing the spars and other machine works required to be done including rates quoted by the contractor . , ( c ) supply only stainless steel pump shaft suitable for 40 hp submersible pumping set 01 each , ( d ) supply only gun metal/bronze impellors suitable for 40 hp submersible pumping set 02 each , ( e ) supply only ms studs , nuts , bolts , washers for submersible pumping set of required size and for column pipes 08 kg , ( f ) supply only thrust plate suitable for 40 hp submersible pumping set 01 each , ( g ) supply and replacement of rubber gasket for ms flanges 150mm bore 15 each...

Military Engineer Services - Punjab

24445239 repair of submersible pump installed at firing range dablan ge ( n ) patiala , repair of submersible pump to include the following services : ( a ) disconnecting the electric connections of submersible pumping set of capacity of 40 hp from panel board and taking down complete pump set with electric motor and column pipes manually/mechanically , dismantling pump from motor reconditioning the pump set and lowering after repairs as specified and directed by engineer in charge & testing . 01 each jobnote : the parts to be replaced and repairs as required and ordered by engineer in charge shall be paid separately under respective items here in after . , ( b ) transportation the submersible pumping set from pump house to workshop and back , dismantling the pump and replacing unserviceable parts i . e impellors , bushes , sleeves , shaft and neck ring , rubber bushes ec bringing back to site duly painted with anti corrosive paint all as directed by engineer in charge 01 each jobnote : spares such as impellors , shaft , bushes , thrust plates , sleeves , neck ring , rubber bushes etc will be paid under respective items . however the cost of fixing the spars and other machine works required to be done including rates quoted by the contractor . , ( c ) material & labour for rewinding the submersible electric motor of capacity 3 phase , 10 hp 400/415 volts 50 c/s by opening the motor removing all burnt coils , cleaning the slots and rewinding the same with pvc insulated copper wire of exisitng gauge including providing bamboo pieces for locking the slots and reassembling , testing and commissioning of electric motor on full load for 8 hours continous running . 01 each job , ( d ) supply only gun metal/bronze impellors suitable for 40 hp submersible pumping set 01 each , ( e ) supply only ms studs , nuts , bolts , washers for submersible pumping set of required size and for column pipes 06 kg , ( f ) supply only thrust plate suitable for 40 hp submersible pumping set 01 each , ( g ) supply and replacement of rubber gasket for ms flanges 150mm bore 14 each...

Military Engineer Services - Punjab

24324868 repair of submersible pump installed at amn dump barsat ge ( n ) patiala , repair of submersible pump to include the following services : ( a ) disconnecting the electric connections of submersible pumping set of capacity of 40 hp from panel board and taking down complete pump set with electric motor and column pipes manually/mechanically , dismantling pump from motor reconditioning the pump set and lowering after repairs as specified and directed by engineer in charge & testing . 01 each jobnote : the parts to be replaced and repairs as required and ordered by engineer in charge shall be paid separately under respective items here in after . , ( b ) transportation the submersible pumping set from pump house to workshop and back , dismantling the pump and replacing unserviceable parts i . e impellors , bushes , sleeves , shaft and neck ring , rubber bushes ec bringing back to site duly painted with anti corrosive paint all as directed by engineer in charge 01 each jobnote : spares such as impellors , shaft , bushes , thrust plates , sleeves , neck ring , rubber bushes etc will be paid under respective items . however the cost of fixing the spars and other machine works required to be done including rates quoted by the contractor . , ( c ) supply only stainless steel pump shaft suitable for 40 hp submersible pumping set 01 each , ( d ) supply only gun metal/bronze impellors suitable for 40 hp submersible pumping set 02 each , ( e ) supply only ms studs , nuts , bolts , washers for submersible pumping set of required size and for column pipes 08 kg , ( f ) supply only thrust plate suitable for 40 hp submersible pumping set 01 each , ( g ) supply and replacement of rubber gasket for ms flanges 150mm bore 15 each...

Military Engineer Services - Punjab

24324856 repair of submersible pump installed at firing range dablan ge ( n ) patiala , repair of submersible pump to include the following services : ( a ) disconnecting the electric connections of submersible pumping set of capacity of 40 hp from panel board and taking down complete pump set with electric motor and column pipes manually/mechanically , dismantling pump from motor reconditioning the pump set and lowering after repairs as specified and directed by engineer in charge & testing . 01 each jobnote : the parts to be replaced and repairs as required and ordered by engineer in charge shall be paid separately under respective items here in after . , ( b ) transportation the submersible pumping set from pump house to workshop and back , dismantling the pump and replacing unserviceable parts i . e impellors , bushes , sleeves , shaft and neck ring , rubber bushes ec bringing back to site duly painted with anti corrosive paint all as directed by engineer in charge 01 each jobnote : spares such as impellors , shaft , bushes , thrust plates , sleeves , neck ring , rubber bushes etc will be paid under respective items . however the cost of fixing the spars and other machine works required to be done including rates quoted by the contractor . , ( c ) material & labour for rewinding the submersible electric motor of capacity 3 phase , 10 hp 400/415 volts 50 c/s by opening the motor removing all burnt coils , cleaning the slots and rewinding the same with pvc insulated copper wire of exisitng gauge including providing bamboo pieces for locking the slots and reassembling , testing and commissioning of electric motor on full load for 8 hours continous running . 01 each job , ( d ) supply only gun metal/bronze impellors suitable for 40 hp submersible pumping set 01 each , ( e ) supply only ms studs , nuts , bolts , washers for submersible pumping set of required size and for column pipes 06 kg , ( f ) supply only thrust plate suitable for 40 hp submersible pumping set 01 each , ( g ) supply and replacement of rubber gasket for ms flanges 150mm bore 14 each...