Tata Memorial Centre - Punjab

39765328 extra low voltage ( elv ) to provide extra low voltage ( elv ) items , intelligent addressable fire detection system supply of intelligent addressable fire alarm panelmicroprocessor based technology; combination photo, thermal, and infrared technologywith fire fighter master telephone control and battery back up as per nfpa 72along with all the mounting accessories. the panel shall have minimum 640 character backlight display with supports up to 159 detectors and 159 modules per slc, 318 devices per loop / 3, 180per facp or network node. built in alarm, trouble, security, and supervisory relays. history file with 4000 event capacity in nonvolatile memory, plus separate 1000 event alarm only file. 2 loop panel , supply of intelligent addressable photothermal infra red detector with detector base & detector junction box along with all the mounting accessories. , supply of intelligent addressable ror cum fixed type thermal detector with detector base & detector junction box along with all the mounting accessories. , supply of response indicator with back box along with all the mounting accessories. , supply of gi box 2 module , supply of intelligent addressable manual call point with back box along with all the mounting accessories. , supply ofhooter cum strobe with back box, required power supply along with all the mounting accessories. , supply of intelligent addressable control module with back box along with all the mounting accessories. ( for hooter cum stobe ) , supply of intelligent addressable control relay module with back box along with all the mounting accessories. ( for ahu tripping purpose ) , supply of intelligent addressable monitor module with back box along with all the mounting accessories. , supply of intelligent addressable fault isolator module with back box along with all the mounting accessories. , supply of2 c x 1.5mm2cross sections, copper conductor, frls pvc sheathed armoured cable for loop with all accessories. , supply of2 core 24v dc power wire for hooter ( 2c x 1.5 sq.mm frls flexible cable ) , voice evacuation system ( pa system ) supply of 6w ceiling speaker with an excellent audio performance and aesthetic appealing enclosure. this speaker features a high sound pressure level and a wide frequency response and low distortion for high sound level suitable for speech and music reproduction model no: hn cl06 , supply of class d type digital power amplifiers, rack mount along with all the necessary support & mounting brackets, cabling and all other complete accessories. 1 x 500 w , 1 x 240 w , supply of 19 15u rack for mounting of controller, amplifier, etc. the rack shall be provided with utility sockets, cabling with cable ties & proper cable management, fansfor ventilation, cable entry plates / ports and all other necessary complete accessories. battery back up of sufficient rating shall be provided to for 24 hours during normal operation and 30 minutes during alarm condition. , supply of 2cx1.5 sq.mm stranded copper conductor, twisted pair, sheilded, pvc insulated, frls pvc sheathed armoured cable , gi saddle 1 / 4 , screw 1.5 black phosphated drywall gypsum screw , rawal plug 25*6 mm , cctv system and telephone system supply of ip indoor fixed dome camera, poe based ( with maximum wattage of 5 watts per camera ) , 1 / 2” cmos / ccd sensor, resolution: 2 megapixels ( 2048 x 1536 ) for color;1 megapixel ( 1280 x 960 ) for b / w , frame rate: cif 30 fps, vga 30 fps, mega 20 fps. h.264 and mjpeg stream, 1 lux colour / 0.1 lux bw @ 1 / 60 sec, , wide dynamic range, duplex bi directional audio support, sdhc memory card slot, megapixel, supported protocols: tcp / ip, http, ftp, smtp, dns, ntp, snmp, onvif support along with all the necessary mounting brackets, fixing supports, poles, junction box, patch cables, etc. with complete accessories. ( note: vendor to specify the considered lens size ) compatible with hus user version 5 software , supply of wdr ptz ip camera, poe based ( with maximum wattage of 31 watts per camera ) , 1 / 2.8 2 megapixel sensor sony progressive cmos with auto / colour / bw day night, 360 degree, optical zoom 30x and digital zoom16x, full hd 1080p resolution, 50 / 60fps imag, true wdr 120db ensure glare free images, motion sensor, supports upto 128gb micre sdhc ( class 10 ) card for local video storage on events, contiuous, or schdule, or with network interuption. ip67 / ip66 wheather proof and ik10 vandal resistant camera housing.wide dynamic range, duplex bi directional audio support, sdhc memory card slot, megapixel, supported protocols: tcp / ip, http, ftp, smtp, dns, ntp, snmp, onvif support along with all the necessary mounting brackets, fixing supports, poles, junction box, patch cables, etc. with complete accessories. ( note: vendor to specify the considered lens size ) compatible with hus user version 5 software , supply of sip telephone instruments , supply of 48 port cat 6 patch panel, fully loaded, rack mount complete withi / o socket , supply of 24 port cat 6 patch panel, fully loaded, rack mount complete with i / o socket , supply of distributed network switches ( 48 port cat 6 type, 10base t / 100base tx / 1000base t, with gigabit interface 4 fibre optic port, ( 1 / 10g uplink ) sfp+ trans receiver module, poe based ) , rack mount, along with all the necessary fixing supports, patch cables, etc. with complete accessories. , supply of distributed network switches poe ( 24 ] port cat 6 type, 10base t / 100base tx / 1000base t, with gigabit interface 2 / 4 fibre optic port, sfp trans receiver module, poe based ) , rack mount, along with all the necessary fixing supports, patch cables, etc. with complete accessories. , supply of 15 u rack with cable managers, utility switches complete with all accessories , supply of single port rj 45, cat6information outlet , supply of 1 module pvc box , supply of 4 x 4pvc box , supply of 4 x 4gi box , supply of single port rj 45, i / o face plate , supply of cat 6 patch cord 1 mtr. ( field side & rack side ) , supply of utp cat 6 unarmoured cable , supply of heavy duty upvc trunking 50x50mm std length 2 mtrs , supply of heavy duty flat angle 100x50 , supply of heavy duty flat tee 50x50 , supply of heavy duty end cap 50x50 , supply of heavy duty 32x12.5mm dia. pvc trunking ( casing caping ) , supply of heavy duty 32x12.5mm external angle , supply of heavy duty 32x12.5mm flat tee , flexible pipe 25 mm white , gi raceway 100 x 50 mm with cover , anchor fastner ( drop in anchorfastner ) for 16mm rod , gi screw 1 / 2 , thread rod 1000mm length for 16mm drop in anchor fastner , screw 1.0 black phosphated drywall gypsum screw...

Indian Institute Of Science Education And Research - Punjab

39313533 tender for annual maintenance contract of 66 / 11 kv sub station; 1 annual maintenance and repair of 66 / 11 kv electrical sub station having the following: 66 / 11 kv , 6.3 / 8 mva three phase power transformer ( 2 nos ) , 72.5 kv 31.5 ka 1600 amp sf6 ckt breaker ( 3 nos ) , 72.5 kv 31.5 ka 1250 amp isolators without earthswitch ( 6 nos ) , 72.5 kv 31.5 ka 1250 amp isolators with earthswitch ( 1 nos ) , 60 kv zno surge arresters ( gapless ) ( 9 nos ) , instrument transformers : 72.5 kv 31.5 ka cts of ratio 300 150 / 1 1 accuracy class 0.2, 0.2 , burden 20va, 20va ( 3 nos ) , 72.5 kv 31.5ka cts of ratio 150 75 / 1 1 1 1 of accuracy class 0.2, ps, ps, ps, burden 20va, 20va, 20va, 20 va ( 6 nos ) , 72.5 kv pts of ratio 66kvv3, 110v / v3, 110v / v3 of accuracy class 0.2, 0.2 burden 50va, 50va ( 3 nos ) , 72.5 kv pts of ratio 66kv / v3, 110v / v3, 110v / v3 of accuracy class 0.2 3p, 0.2 3p, burden 50va, 50va ( 6 nos ) , power cables ( aluminium, armoured ) : 11kv ( earthed ) xlpe 3c x 185 sq mm ( 600 mtr ) , 11kv ( earthed ) xlpe 3c x 35 sq mm ( 75 mtr ) , 1.1 kv xlpe 3.5c x 70 sq mm ( 150 mtr ) , 1.1 kv xlpe 3.5c x 25 sq mm ( 100 mtr ) , 1.1 kv xlpe 4 x 6 sq mm ( 800 mtr ) , 1.1 kv xlpe 1 x 10 sq mm ( 50 mtr ) , frls control cables ( copper, armoured ) : 12c x 4 sq mm ( 1000 mtr ) , 10 c x 2.5 sq mm ( 400 mtr ) , 4c x 4 sq mm ( 1500 mtr ) , 4c x 2.5 sq mm ( 500 mtr ) , 12 kv 12 panel vcb switch board ( 1 set ) , 220v 100ah battery ( 1 set ) , 10a / 20a battery charger for 220v, 100ah battery. ( 1 set ) , 11 / 0.4, 63 kva dry type station transformer ( 1 set ) , 25kva, 3 phase dg set with sound proof enclosure ( 1 set ) , lt switchgear: 415v acdb ( 1 set ) , 200v dcdb ( 1 set ) , 72.5 kv control & relay panel: incomingline panel ( 1 nos ) , transformer panel ( 2 nos ) , switchyard erection material like conductor, earth electrode, earth mesh of complete switch yard and earthing connection to all equipments, lightning protection of switchyard ( earth wire screen ) disc insulators, hardware fitting, connectors, fire fighting system of transformers. gantry towers and beams for switchyard and equipment and support structure for all equipments: bay marshalling kiosks ( 3 nos ) , including deputing trained person during working hours six days a week. 2 consumables parts ( from sl. no. 3 to 63 ) etc to be used duringamc on need basis 3 bus bar aluminium ( 60x10mm ) 4 new ct 400 / 5a / 1a 5 epoxy ( spot ) insulators ( cg make 11 kv ) 6 spots ( cg make 11 kv ) 7 bus bar cross bushing for cg make 11 kv panel 8 fiber sheets for cg make 11 kv panel 9 new repair of pin / male contacts ( cg make 11 kv ) 10 transformer oil 11 new repair of jaws / tulip contacts ( cg make 11 kv ) 12 vaccuum bottle reconditioning ( cg make 11 kv ) 13 vaccuum bottle new ( cg make 11 kv ) 14 monoblock insulation with varnish for cg make 11 kv panel 15 painting of existing cabinet and removal of rust and moisture for cg make 11 kv panel 16 repair of spring charging motor for cg make 11 kv vcb. 17 ht cable sleeve set. 18 ht insulator for bus bar mounting in 11kv vcb. make : cg or eq. 19 indoor cable end termination with heat shrinkablejointingkitcompletewithallaccessoriesincluding lugssuitablefor185 sq. mm, 3 core, xlpealuminium conductor cable of 11 kv grade. make : cg / raychem rpg / 3m. 20 epoxy insulator ( phase to phase separator for 11kv ht vcb feeder ) .make : cg or eq. 21 monoblock for fix contact ( panel side ) in 11kv ht panel.make : cg or eq. 22 oil monitoring gauge for power transformer 6.3 / 8mva. 23 mounting channel for mounting insulators in 11kv vcb.make : cg or eq. 24 digital active power meter in mw unit, mf for ctr 150 / 1a = 2. make : ae or eq. 25 digital reactive power meter in mvar unit, mf for ctr 300 / 1a = 2. make : ae or eq. 26 digital reactive power meter in mvar unit, mf for ctr 150 / 1a = 2. make : ae or eq. 27 p / f duco / automotive / hammerstonepaint on electrical ht power panel including filling, surface preparation, etc. 28 power pack battery, 12v 7ah, smf type.make : amaron / exide / rocket. 29 11 kv ht vcb adapter assembly 30 push button, green, black, red colour 31 ht vcb stopper rubber bush 32 ht / lt panel door lock 33 indicator ( red, yellow, green, blue, white ) 34 power packfor 11 kv panel 35 dehydration of transformer of capacity 6.3 / 8 mva 36 power pack battery, 12v 7ah, smf type.make : amaron / exide / rocket. 37 silica gel 38 pt for 11kv vcb panel, ratio 11000 / 110 / 110, va / class lv i 100 / 0.5, lv ii 100 / 3p, yyy connection, 50 hz. make : crompton greaves 39 breather assembly 1 kg 40 breather assembly 5 kg 41 vmr 3 phase relay. make : proton or eq., model : pr 07 42 contactor.make : abb, model : ua 30 30 10ra 43 ampere meter ( analog type ) . make : ae or eq. 44 providing and fixing 25mm x 5mm gi strip on surface or in recess for connections etc as required. 45 vcb interrupter bottle of 11kv ht breaker including its housing, dismantling, fitting. 46 pt set including male female insulators for 11 kv vcb incl. fitting. 47 overcurrent earth fault relay, aux 18 52 vdc, ct 1a / 5a.make : crompton greaves ( cgi14n model ) 48 ht panel space heater completewith thermostat, holder etc. 49 power pack with battery backup, input 230v ac, output 24v dc, 4a. make : alan, model: app 230024 or eq. 50 spring charging motor 51 tnc switch 52 pt fuse with holder 53 oc / ef protection relay, 6x6. make : ashida, model : adr 141a 54 11kv vcb pt set 55 tripping coil 24v 56 analog ampere meter 600 / 5a 57 11 kv vcb ct for 200 / 100 / 5amp 58 rack in mechanism for 11 kv vcb of cg make, code : 1syptp22043. 59 digital ammeter 60 main mechanism for 11 kv vcb of cg make, code : 1tpasb22443 61 sf6 gas cylinder for 66 kv breaker. capacity 9 kgs 62 ct set for 11 kv vcb. make cg, code 200 102319...

Water Supply And Sanitation Department - Punjab

37847280 tender for supply and erection of single phase copper wound automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140 260 volts single phase ac supply and output voltage 220 ± 5% volts single phase ac supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the ms sheet box of suitable size. there should be power control relay and single pole mcb (c curve, 10ka) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided., automatic voltage stablizer 4 kva, p/f capacitor of ac, repair of 200mm i/d sluice valve including cost of opening, carriage from govt. college to workshop at lathe machine & back fitting at site with providing of ss spindle, jain dori, nut bolt...

Indian Army - Punjab

36851972 bids are invited for demand of stores power contacor , control relay , micon 175 , on oblique off , washer gun , vsp 3 , gas , steel barrel , sensor gun , led , lubracating grease , car vaccum cleaner , can , funnel , bareel pump , battery charger total quantity : 449...

Military Engineer Services - Punjab

35865589 tender for repair / replacement / maintenance of misc items including installation high mast lights, eot crane solar water heater systems and water heaters at af stn bhisiana supply , laying , jointing and testing in replacementxlpe insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sq mm 4 core with aluminum thimble of same size complete all as specified and directed by engineer in charge. 2 supply , laying , jointing and testing in replacement xlpe insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sq mm 4 core with aluminum thimble of same size complete all as specified and directed by engineer in charge. 3 excavation in trenches not exc. 1.5 m wide and notexceeding 1.5m depth for foundation of poles / laying of cables / stay / strut etc not exceeding 10 sq m on planand getting out in soft / loose soil complete all as specified and directed by engineer in charge. 4 returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by engineer in charge. 5 removing excavated material ( soil ) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by engineer in charge. 6 m&l sandcushioning ( fazilka dry sand ) ) in trenches / ducts for protection of ug cables ( below, above and around the ug cable laid ) of 23 cm spread thickness ( 8 cm in depth before laying the cable and 15 cm in depth after laying the cable ) and consolidated ( punned ) upto 180mm thickness, complete all as specified and as directed.note : for the purpose of payment, punned thickness of sand cushioning only will be measured. 7 m&l for brick protection cover of under ground cable by old size bricks common burnt clay building bricks sub class `b’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed by engineer in charge. 8 supply and fix in replacement led electronicdriver suitable for 60 watt ledas light sources incluing taking down and old fitting as per repairingrequirement complete all as specified & directed by engr in charge. 9 supply and fix in replacement led electronicdriver suitable for 45 watt ledas light sources, incluing taking down and old fitting as per repairingrequirement complete all as specified & directed by engr in charge. 10 supply and fix in replacement led post top lantern with die cast aluminium spigot, spun aluminium, powder coated top cover acrylic diffuser ip 65 protection class of 25 / 30 watt fitted on the piller with the help of gi pipe / pcc work / nut bolts and connection with 2.5 sqmm 3 core copper cable including all fixing accessories complete all as specified and directed engr in charge. 11 m&l in replacement for highly efficient led street light 90 watt luminaries new generation energy saving & environment friendlywith lens made of pressure die cast aluminium alloyhousing lm24 for gear and exturded alluminium lamp housing & enclouser with toughened glass with ip 66 of protection class, with high power leds as light source having luminous efficiency should be > 80lm / w with active power factor correction ( apfc ) electronic gear ( heat shrink for better heat transmission ) .it shall have epoxy powder coated grey finish phosphochromate treatment and operating voltage range should be fron 120 volt to 270 volt ac and frequency range 50hz and suitable for an ambient temparature from 40°c to 50 °cand humidity level 10% to 90% including connection with pvc unsheathed wirealuminium conductor 3 x 1.5sqmm fitted on pole / building with gi bracket of suitable size and connection with 2.5 sqmm 3 core wire upto bus bar of oh line / pvc jn box / lt panel / building for connection including taking down of unserviceable light fitting of any type / size complete all as specified and directed engr in charge. 12 s&f pvc insulated multi stranded copper conductor cable 1.5 sqmm 3 core, round flexible for connection of street light fitting with bus bar and flexible conduit including taking down unserviceable cable of any description, complete all as specified and as directed. 13 m&l in replacement for highly efficient integral type led flood light 60 watt new generation energy saving & environment friendly made of pressure die cast aluminium with lens & enclouser with toughened glass with ip 66 of protection class, with high power leds as light source having luminous efficiency should be > 80lm / w with active power factor correction ( apfc ) electronic gear ( heat shrink for better heat transmission ) .it shall have epoxy powder coated grey finish phosphochromate treatment and operating voltage range should be fron 120 volt to 270 volt ac and frequency range 50hz and suitable for an ambient temparature from 40°c to 50 °cand humidity level 10% to 90% including connection with pvc unsheathed wirealuminium conductor 3 x 1.5sqmm fitted on pole / building with gi bracket of suitable size and connection with 2.5 sqmm 3 core wire upto bus bar of oh line / pvc jn box / lt panel / building for connection including taking down of u / s light fitting of any type / sizecomplete all as specified and directed engr in charge. 14 m&l for scraping down and removing of old deteroirated paint from existing steel tubular poles above ground level, preparing surface for painting, applying two coats of aluminium paint upto full height of pole including ms clamps, gi brackets, fittting etc.complete all as directed at site including black and white strips of30cms each upto 1.5 mtrs above pccwith black and white paint and marking of pole no. 2 mtr above pcc , cutter shoud not be long than 6 cms height as 16 cm dia circle around the marker number complete all as directed by engr in charge. 15 m&l in replacement for time light distribution board switches of capacity 65 amps digitial timer box including ( i ) contactor rating 65 amp 3pole / 230v, ( ii ) digital timer programmable type and ( iii ) mcb 65 amp tpn, ( iv ) copper wiring required for connections ( v ) selecter switch. the timer box out door type, mounted on gi angle iron frameof size 25x25x4mm grouted in cement concrete, including necessary excavation and earth work, connection of lt ug cable.complete all as specified and directed by engr in charge. 16 m&l for welding of existing lt panel / bus bar chamber / junction boxes with the help of welding machine, after filing nuts, bolts, etc. includinglocking arrangement and applying one coat of synthetic enamel ivory paint ( smoke grey ) to steelsurface after disconnecting the electrical connections and reconnection the same at various sitesby taking safety precautions after painting complete as specified and directed by engr in charge. 17 m&l in replacement earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand includinggi strip of size 32x6mmupto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of gi and connected to earhing test point and earth dollyall as shown in electrical plate no 3 of mes ssr part i and testing on completion includingnecessary excavation and earth work in any type of soil, pcc ( 1:3:6 ) type c1 chamber, pre cast rcc slab 50mm thic in cement concrete ( 1:2:4 ) , type b1, reinforced with welded steel wire fabric or xpm, ( weight not less than 4 kg per sqm ) with cast iron frame, funnel with watering pipe 20mm dia medium grade, wire mesh and lugs, gi protection pipe, 15mm dia, light grade, 7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed. 18 s&f in replacement of pvc sintex pole mounted junction box 250x250mm, having 04 nos of aluminium bus bar mounted on insulator with the help of nut, bolts, clamps including single pole mcb of 6 amps, 2.5 sqmm copper conductors cable 3 corefor connection of incoming and outgoing cables complete all as specified and directed by engineer in charge 19 s&f in replacement of sheet metal ( ms ) bus bar box single door, outdoor type weather proof, size 300x300x200mm mounted on ground with iron angles ( 25x25x4mm ) . having alluminium bus bar 4 nos, rated 100amp all as specified & directed by eng in charge. 20 m&l for highly efficient integral type led flood light 200 wattenergy saving & environment friendly made of pressure die cast aluminium with lens & enclouser with toughened glass with ip 66 of protection class, with high power leds as light source having luminous efficiency should not be less 90 lumen with active power factor correction ( apfc ) electronic gear ( heat shrink for better heat transmission ) .it shall have epoxy powder coated grey finish phosphochromate treatment and operating voltage range should be fron 120 volt to 270 volt ac and frequency range 50hz and suitable for an ambient temparature from 40°c to 50 °cand humidity level 10% to 90% including connection with pvc unsheathed wirecopper conductor 3 x 4.0 sqmm fitted on high mast pole includingconnection and taking down of old unserviceable light fitting complete all as specified and directed engr in charge. 21 m&l for preventive maintenance of existing eot crane at height of 20 to 22 metre ( approx ) from representative of firm as approved by ge including ( i ) dismantling of hoisting gear box, ( ii ) drain of old oil, ( iii ) cleaning & greasing of gear box long travel and cross travel and refilling of fresh oil ( iv ) fill up fresh oil in gear box ( v ) checking of hoisting, long travel, cross travel, brake unit , oiling of brake unit pins. greasing of long travel cross travel wheel bearing, checking of panel board and connections , checking of rail alignment, checking of cross travel alignment.checking and oiling greasing of wire rope, rope drum, pedstal bearings, load test using dead weight and any minor defects all connections electrical / mechanical components, including any minor repair deemed to be included in the above quoted rate complete all as specified and directed by eng in charge.note: ( i ) all work shall be executed in presence of contractor, he will be solely responsible for safety of working personels at site. ( ii ) contractor shall provide necessary t&p, safety equipmentsoil, grease, gear box oil, cloth waste and minor spare required and any other material required for executionwill be deemed to be in quoted unit rate. ( iii ) approval of the firm shall be taken from ge before works commencement. 22 m&l for maintenance of existing traffic control barrier, including: winding of 0.5 hp electric motor, wiring of control panel, replacement of control switches, repairing & greasing of mechanical unit & gear box mechanism, painting work & fabrication work required. including ( i ) 6 sqmm xlpe cable100 rm for electric supply ( ii ) 2.5 sqmm 3 core copper cunductor100rm ( ii ) excavation work for both supply cable and signal cable etc.complete all as specified and directed by engg in charge. note: this job included all electrical and mechanical items require to make the road barrier in serviceable condition. 23 s&fpvc insulated multi stranded copper conductor cable 6 sqmm 4 core, round flexible for connection with circuit including taking down unserviceable cable of any description, complete all as specified and as directed. 24 s&f pvc insulated multi stranded copper conductor cable 4 sqmm 3 core, round flexible for connection with circuit including taking down unserviceable cable of any description, complete all as specified and as directed. 25 material and labour for contactor ofcoil voltage 110 volt model mnx 25 including taking down unserviceable contactorof any description, complete all as specified anddirected by engineer in charge. make l&t / havells / c&s 26 material and labour for single phase preventor including taking down unserviceable preventorof any description, complete all as specified anddirected by engineer in charge. 27 material and labour for suitable rocker holder of eot crane 2 tonincluding taking down unserviceable rocket holderof any description, complete all as specified anddirected by engineer in charge. . 28 material and labour for iec style control relay , 24 vdc, 10a and 18 pins including taking down unserviceable iec style control relayof any description, complete all as specified anddirected by engineer in charge. . 29 m&l in replacementvfd for 2 ton eot crane 1.5 kw, 2 hp including connection and testing complete all as specified and directed by eng in charge. make delta / schneider or equivalentnote: ( i ) all work shall be executed in presence of contractor, he will be solely responsible for safety of working personels at site. ( ii ) contractor shall provide necessary oil, grease, gear box oil, cloth waste and minor spare required willdeemed to be in quoted rate. ( iii ) the contractor shall replace the vfd in control panel which is 20 22 mtr height from ground 30 m&l in replacementvfd for 2 ton eot crane 2.2 kw, 3 hp including connection and testing complete all as specified and directed by eng in charge. make delta / schneider or equivalentnote: ( i ) all work shall be executed in presence of contractor, he will be solely responsible for safety of working personels at site. ( ii ) contractor shall provide necessary oil, grease, gear box oil, cloth waste and minor spare required will be deemed to be in quoted rate. ( iii ) the contractor shall replace the vfd in control panel which is 20 22 mtr height from ground 31 m&l in replacement ofvfd for 2 ton eot crane5.5 kw, 7.5hp including connection and testing complete all as specified and directed by eng in charge. make delta / schneider note: ( i ) all work shall be executed in presence of contractor, he will be solely responsible for safety of working personels at site. ( ii ) contractor shall provide necessary oil, grease, gear box oil, cloth waste and minor spare required will be deemed to be in quoted rate. ( iii ) the contractor shall replace the vfd in control panel which is 20 22 mtr height from ground 32 m&l for dismantaling and taking down complete 25 / 35 / 50 ltr capacity geysers from site and brought to e / m store yard & refixing the same after carrying out following works: ( i ) complete cleaning and de scaling of inlet and outlet connections, inner tanks, fittings, fixtures & outlet pipelines etc with suitable chemical agent. ( ii ) complete servicing and maintenance. ( iii ) replacement of unserviceable spares as deemed necessary such as inner tank, outer cover, inner assembly, glasswool, rubber gaskets, nuts, bolts, clamps, etc., repair of minor leakages if any by carrying out minor welding / brazing. ( iv ) complete testing and to ensure proper functioning & maintaining proper water temparature complete all as specified and directed.note: the cost for all spares & items such as heating element thermostat, inner assembly, inner tank, outer cover, etc shall be paid in respective items separately. 33 m&l for spray painting to existing geysers of capacity 25 / 35 ltrs with two coat of synthetic enamel white paint over one coat red oxide ( primer ) including scratching of old paint and making surface smooth by using filler etc complete all as specified and directed by engineer in charge. 34 m&l for spray painting to existing geysers of capacity 50 ltrs with two coat of synthetic enamel white paint over one coat red oxide ( primer ) including scratching of old paint and making surface smooth by using filler etc complete all as specified and directed by engineer in charge. 35 s&f in repair pvc connection pipe 15mm size and 45 cm in length with adopter nuts of pvc , complete all as specified and as directed. 36 s&f geyser element 2 kw, isi mark ( as approved ) including taking down / out unserviceable one, complete all as specified and as directed by engineer in charge. 37 s&f in replacement of thermo static switch of geyserincluding taking down / out unserviceable one, complete all as specified and as directed by engineer in charge. 38 s&f in replacement brass safety valve, isi marked for geysers, including taking down / out unserviceable one, complete all as specified and as directed by engineer in charge. 39 replacement of indicating bulb of geyser including taking down / out unserviceable one, complete all as specified and as directed by engineer in charge. 40 s&f pvc insulated multi stranded copper conductor cable 2.5 sqmm 3 core, round flexible for connection to geyser including taking down unserviceable cable of any description, complete all as specified and as directed. 41 m&lfor grouting the one set of bolts / anchor / fastners of suitable size including nuts ( one set include four bolts and four nuts ) in wall including taking down & refixing the existing geysers at site any make & size and making good the disturbed surface, complete all as specified and directed. 42 s&f in replacement only outer body / cover suitable for 25 / 35 ltr cap geyser made out of mild steel pre treated and stove enamelled sheet of 18 swg complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body easing including two coat of white synthetic enameled paint over one coat of red oxide primer, complete all as specified and directed. 43 s&f in replacement only outer body / cover suitable for 50 ltr cap geyser made out of mild steel pre treated and stove enamelled sheet of 18 swg complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body easing including two coat of white synthetic enameled paint over one coat of red oxide primer, complete all as specified and directed. 44 s&f in replacement ofinner tank made of stainless steel for geysers of capacity 25 / 35 ltr complete all as specified and directed. 45 s&f in replacement ofinner tank made of stainless steel for geysers of capacity 50 ltr complete all as specified and directed. 46 s&f in replacement geyser inner assembly complete as per existing shape / size as per existing for geyser of capacity 25 / 35 / 50 ltr having suitable numbers of slots & pipes provisions complete with rubber gasket & bolts for fixing completeall as specified and directed. 47 s&f in replacement glass wool of minimum density48 kg / m3 of approved quality, and quantity as per requirement for geyser of any capacity complete all as specified and directed. 48 s&f in replacement bottom inspection cover in two pieces made of minimum size 20 swg gi sheet suitable for 25 / 50 ltrs capacity geysers of any make, inclusive of one red oxide primer coat, one under coat and one finishing coat ofwhite color paint complete on outer surface and inner surface, complete all as specified and directed. 49 s&f in replacement top cover made of minimum 20 swg size gi sheet suitable for 25 / 50 ltrs capacity geysers of any make, inclusive of one red oxide primer coat, one under coat and one finishing coat ofwhite color spray paint complete on outer surface and inner surface, complete all as specified and directed. 50 labour only for attending complaints, carry out inspection, identifying the fault of geyser / solar water heating system at various location and making geyser / solar water heating system serviceable after testing, complete all as specified and directed.notes: ( i ) cost of minor spares such as rubber gaskets, nuts, bolts, clamps, flanges and minor welding / brazing and loose connection deemed to be included in the quoted rates. ( ii ) cost of major spare such as heating element, thermostat, hot water pipe, mcb, safety valve, indicating bulbwill be measured and paid under respective items of schedule. ( iii ) if contractor fail to attend / rectify complaints within 16 hrs of complaint time, recovery at rs @ 200 per day will be done form workdone amount. ( iv ) geyser already considered under item no 32 here in before shall not be considred under this item. 51 supply, laying & testing of tubes ( in repair ) , medium grade galvanised, 15mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors including taking out unserviceable, complete all as specified and directed. 52 s&f in repair angle valve 15mm bore ( dia ) , cast copper alloy, chromium plated, screwed down, high pressure, screwed both ends for iron pipe with wall flange, complete all as specified and as directed. 53 s&f in repairs bib tap 15mm bore ( dia ) , 2 in 1, cast copper alloy, chromium plated, suitable for fixing of jet including flange screwed down, complete all as specified and as directed. 54 m&l submain wiring with 2 runs of copper conductor pvc insulated unsheathed cable 1100 volt grade 4 sqmm drawn through pvc conduit medium grade isi marked 25mm dia as per is specification fixed concealedin wall / ceiling including conduit and conduit accessories and incl provn of pvc insulated 2.5 sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site.note : two runs of 4 sqmm cable alongwith one run of 2.5 sqmm pvc insulated unsheathed copper conductor as earth wire, conduitand conduit accessories will be measured as one length. 55 s&f in repairs metal plug and socket including one no. mcb 20a complete all as specified and directed by engr in charge. 56 m&l for dismantaling and taking down complete solar water heater system of 300 lpd capacity installed at single / double / triple storey bldgs and re fixing the same after carrying out following works: ( i ) complete cleaning and de scaling of inlet and out let connections, solar collectors, glasses, hot water tank, cold water tank, make up tank, fittings, fixtures & pipelines etc with suitable chemical agent. ( ii ) complete servicing and maintenance. ( iii ) replacement of unserviceable spares as deemed necessary such as hot water tank, flat plate collectors, rubber gaskets, nuts, bolts, clamps, flanges etc., repair of minor leakages if any by carrying out minor welding / brazing. ( iv ) complete testing and to ensure proper functioning & maintaining minimum water temparature i.e. 60°c complete all as specified and directed.notes : ( a ) cost of minor spares such as chemical agents, rubber gaskets, nuts, bolts, clamps, flanges etc and minor welding / brazing deemed to be included in the quoted rates. ( b ) the cost of hot water tank, flat plate collectors shall be paid in respective items separately. 57 m&l for hot water tank in replacement of capacity 300 ltrs without heat exchanger ( non pressurized ) type, cylindricalshape, inner tank made of ss 304l with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool / rockwool not less than 100mm thick layer & outer metallic body and including suitable electrical backup ( heating elements & thermostat ) , sacrificial anode, temperature guage & make up tank etc. complete all as specified and directed. the electrical back up system should be thermostatically controlled at 50°c for hard water and 55°c 60°c for soft water. 58 m&l for hot water tank in replacement of capacity 200 ltrs without heat exchanger ( non pressurized ) type, cylindricalshape, inner tank made of ss 304l with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool / rockwool not less than 100mm thick layer & outer metallic body and including suitable electrical backup ( heating elements & thermostat ) , sacrificial anode, temperature guage & make up tank etc. complete all as specified and directed. the electrical back up system should be thermostatically controlled at 50°c for hard water and 55°c 60°c for soft water. 59 m&l in replacement for flat plate collector isi marked in the standard size of 1860mmx1240mmx100mm ( minimum dimensions ) complete in all respects having fabricated aluminium sheet outer frame casing & back plate and toughened radiation glass having exellent solar transmittance, heat absorbing unit shall be consisting of copper sheet ultrasonic / laser welded to specified nos of copper tubing grid, with selective black chrome or ultra selective sputtered coating, absorber plate must be encased in not less than 50mm resin bonded insulation & aluminum foil for barrier against out gassing complete with end plates, collars and fixing arrangement with washer / rubber seals / hose pipe connection etc. complete all as specified and directed 60 supply, laying & testing of tubes ( in repair ) , medium grade galvanised, 20mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors, complete all as specified & directed by engineer in charge. 61 supply, laying & testing of tubes ( in repair ) , medium grade galvanised, 25mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors, complete all as specified & directed by engineer in charge. 62 supply and fixing ( in repair ) of aluminium cladding with wire mesh and minimum 50mm thick glasswool of 48 kg / m3 density for hot water 15 / 20 / 25 mm gi tubing complete with fittings and fixing materials complete all as specified & directed by engineer in charge. 63 s&f in replacement toughned radiation glass having exellent solar transmittance ( minimum 90% ) , of minimum 4 mm sizethick and of standard size as per existing arrangementof solar collector complete all as specified & directed by engineer in charge. 64 s&f in replacement of solar water heater temperature gauge / thermostat as per existing size complete all as specified & directed by engineer in charge. 65 s&f in replacement heating element 5 kw 230v ac, 50 cycle, triangular / round type isi marked complete with rubber gasketfor hot water tank electrical back up system complete all as specified & directed by engineer in charge. 66 s&f in replacement heating element 2 / 3 kw 230v ac, 50 cycle, triangular / round type isi marked complete with rubber gasketfor hot water tank electrical back up system complete all as specified & directed by engineer in charge. 67 m&l submain wiring with 2 runs of copper conductor pvc insulated unsheathed cable 1100 volt grade 6 sqmm drawn through pvc conduit medium grade isi marked25mm dia as per is specification fixed concealedin wall / ceiling including conduit and conduit accessories and incl provn of pvc insulated 4 sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site. note : two runs of 6 sqmm cable alongwith one run of 4 sqmm pvc insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length. 68 s&f vertical mcb db tpn 4 way factory made ip 54 protection class metal double door with 200 amp rating bus bar 240 / 430v including provision for mounting mccb upto 125 amps rating including taking out unserviceable complete all as directed by engr in charge. 69 s&f mcb db spn 8 way factory made ip 43 protection class metal double door with 200 amp rating bus bar 240 / 430v for fixing of mcbs / isolators / rccbs etc including taking out unserviceablecomplete all as specified and directed. 70 s&f mcb db spn 4 way factory made ip 43 protection class metal double door with 200 amp rating bus bar 240 / 430v for fixing of mcbs / isolators / rccbs etc including taking out unserviceable, complete all as specified and directed 71 s&f 3 pole mccb 100 amps 50 hz 415 v with rupturing capacity 16 ka etc including taking out unserviceable, complete all as specified and directed 72 s&f 3 pole mccb 125 amps 50 hz 415 v with rupturing capacity 16 ka etc including taking out unserviceable, complete all as specified and directed 73 s&f mcbs 240 volts 10 ka finger proof terminal, bi connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, isi markedto be fixed on db for following item no 74 & 75note : db shall be measured and paid separately under respective items of sch a. 74 all as per item no 73 but for mcb spn 40 to 63 amps. 75 all as per item no 73 but for mcb sp 5 to 32 amps....

Military Engineer Services - Punjab

35633740 maintenance and testing of mrs and connecting items at nams 1 servicing of ht vcb 11kv, 630a / 800a of kirloskar or as per existing make alongwith tripping system and testing of vaccum circuit breaker 11kv, 630a / 800a , 25ka including taking out breaker / trolley and carried out the fwg repair / tests made for smooth operation ( a ) cleaning and greasing of mechanism 01 job ( b ) tightning testing of mechanism parts 01 job. ( c ) alignment testing and adjustment of mechanism 01 job. ( d ) operation, testing of trip and close electrical and manual mode 01 job. ( e ) spring charging testing electrical and manual mode 01 job. ( f ) cleaning of panel insulater ct &pt unit 01 job. ( g ) cleaning and tightning of control / wiring ct &pt unit 01 job. ( h ) cleaning and testing of relay with current injection method 01 job. ( j ) testing of auxillary relay 01 job. ( k ) allingment of trolley, checking / greasing of shutter / lock of breaker note : ( a ) the cost of minor spare parts i.e springs, grommets, dust cover, ring of isolator contacts, clips, pin for release prop, y phase shround, over ride stop pin , grease and lacker etc. unless or otherwise mentioned here in after but essentially required to make the panel serviceable shall be deemed to be included in the quoted rate. 2 m&l for replacement of complete nut and bolts of vcb complete all as specified and as directed by engr in charge. note : size of nuts and bolts are same as per site no other size and shape accepted.. 3 material and labour in replacement instant relay having tripping control of over current earth fault cat no mc61a of lt make or cat no ir 13010 of c& s make. 4 supply and fixing in replacement automatic voltage regulator relay model avr 102 ( pe system pvt ltd bangalore ) complete all as specified. 5 excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out : ( a ) soft / loose soil 6 excavation in trenches not exceeding 1.5m wide and exceeding 1.5 m in depth but not exc 3 mtr in depth and getting out : ( a ) soft / loose soil 7 returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25cm soil / hard dense soil. 8 removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point. ( a ) soft soil / hard dense soil 9 m & l for natural river sand for cushioning to underground cable in trench all as specified and directed. 10 supply and lay in repair in trenches / road cross / floor etc , tube galvanised iron light grade with all fittings for protection of cable of size 100 mm dia bore all as specified & directed by engr in charge. 11 supply and fixing in replacement complete pt unit 100 / 50 / 5a, 15 va 50hz including wiring and connection suitable for 11kv vcb make areva / kirloskar / cg 12 supply and fixing in replacement of sensor for hv / lv safety element model 2220 r2 complete all as specified. 13 supply and fixing in replacement of hv / lv temp transformers model 2200 r2 complete all as specified. 14 supply and fixing in replacement of silica gel for transformers complete all as specified. 15 dehydration of old transformer oil by heating and maintaing breaking capacity above 40 kv complete all as specified and directed by eic. 16 supply and fixing in replacement ct unit 100 / 50 / 5a, 15 va 50hz suitable for 11kv vcb make areva / kirloskar / cg 17 supply and fixing in replacement push button complete all as specified. 18 supply and fixing in replacement earth fault relay with idmt complete all as specified. 19 supply and fixing 66kv lightening surge arrestor 10 ka class ii metal oxide gapless type as per existing technical specification and size for one phase complete all specified. 20 supply and fix in replacement spring charging electric motor suitable for kirloskar vcb of cap 630 amp with complete accessories as per existing. 21 material & labour for providing 20mm broken stone aggregate including spreading and levelling complete all as specified and directed. 22 servicing and repair / maint of hv sf6 breaker 66 kv alongwith tripping system and carried out the fwg repair / tests made for smooth operation. ( a ) cleaning and greasing of mechanism, operation, testing of trip and close electrical and manual mode, spring charging testing electrical and manual mode, cleaning of panel insulater ct &pt unit, ( a ) service will be carried out through service engineer of manfacturer / authorised service engineer only. ( b ) the cost of minor spare parts i.e nut and bolts, springs, grommets, clips, pin etc and refilling of gas required to make the breaker serviceable shall be deemed to be included in the quoted rate. 23 supply , jointing , testing in repair end termination jointing kit heat shrinkable out door type , suitable for ht 11000 volts grade cable of size 185 sqmm 3 core complete all as specified. 24 supply and fixing in replacement of remote hv winding temparature indicator o 150 degree centigrade model no 2220 r2 complete all as specified. 25 supply and fixing in replacement of remote lv winding temparature indicator o 150 degree centigrade model no 2220 r2 complete all as specified. 26 supply and fixing in replacement remote winding temparature indicator complete all as specified. 27 m& l for one layer of un reinforced precast concrete cable cover class hv type i, flat, size 300 x 180 x 40 mm laid flat in trenches over the cable with length of cover perpendicular to the direction of cable adjacent / abutting each other complete all as specified and as directed.make:approved in einc and isi maked 28 supply and fixing in replacement reomote oil tempatature indicator complete all as specified. 29 taking out carefully manually by excavation of existing lt / ht cable of size 10 sqmm to 95 sqmm with loops and relaying with dwc pipe the same after repair of cutting the damages / burnt parts of cable and reconnecting its into original positions complete with cable joints all as specified and directed by engineer in charge.note: ( i ) ht / lt cable joint & dwc pipe will be measured and paid sepearetly. ( ii ) unit rate shall be included in excavation and returning filling. 30 taking out carefully manually by excavation of existing lt / ht cable of size 120 sqmm to 240 sqmm with loops and relaying with dwc pipe the same after repair of cutting the damages / burnt parts of cable and reconnecting its into original positions complete with cable joints all as specified and directed by engineer in charge.note: ( i ) ht / lt cable joint & dwc pipe will be measured and paid sepearetly. ( ii ) unit rate shall be included in excavation and returning filling. 31 taking out carefully manually by excavation of existing lt / ht cable of size above 240 sqmm with loops and relaying with dwc pipe the same after repair of cutting the damages / burnt parts of cable and reconnecting its into original positions complete with cable joints all as specified and directed by engineer in charge.note: ( i ) ht / lt cable joint & dwc pipe will be measured and paid sepearetly. ( ii ) unit rate shall be included in excavation and returning filling. 32 excavates and relaying lt cables loops near the poles / transformers, cutting the damages / burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by engineer in charge. 33 prunning of trees of over head lines of any voltage by taking proper shutdown & removing the same from site upto a distance of 50 mtr all as directed by engr in charge. 34 material & labour for restrainging acsr conductor ht / lt providing proper sag all as specified and directed. note : upto 5 conductor will be consider as one span only. 35 material and labour for jointing broken / lying on ground conductor and restrach the same conductor with straching of 3 to 4 span complete with maintaing proper sag all as specified and as directed. note : conductor required for jointing broken conductor shall be included in the quoted rate. no extra payment shall be made to the contractor for the same. 36 material and labour for electrical shock treatment chart in hindi , english and punjabi complete with figures and letters complete of size not less than 50 cm x 75 cm engr in charge with white paint complete all as specified and as directed. 37 material and labour for locating the fault in vcb, repair / replacement of defected items, drying moisture from vcb and restand the elect supply complete all as specified and as directed. note : ( i ) all tools and plant including blower and othe equipment will be arranged by the contractor with no extra cost paid to contractor. ( ii ) one vcb will be catered as on job ( iii ) contractor shall deposit / procure all the material in advance to avoid any late night fault / after market hours / non availability of material in market. the elect supply shall be restore within 5 hours from the time of tripping / fault in day or night in the stn, failing this a panelty of rs 5000 / per complaint / fault will be imposed on the contractor from contractor dues. ( iv ) minimun one vcb shall be produce to contractor for restand / repair for one visit. contractor will not demand all vcb repair in one visit. visit and repair charges of electrician and helper are included in the quoted rate. no extra charges paid to contractor. 38 material and labour for locating the fault in transformer of any capacity , pole mounted / plinth mounted, laid indoor on ground , repair / replacement of defected gasket, ht bush , lt bush, replacement of thimble of transformer , maggering transformer for detecting fault and retapping complete and make the transformer serviceable complete all as specified and as directed. note : ( i ) all tools and plant including magger , ladder and othe equipment will be arranged by the contractor with no extra cost paid to contractor. ( ii ) one transformer will be catered as on job ( iii ) contractor shall deposit / procure all the material in advance to avoid any late night fault / after market hours / non availability of material in market. the elect supply shall be restore within 5 hours from the time of tripping / fault in day or night in the stn, failing this a panelty of rs 5000 / per complaint / fault will be imposed on the contractor from contractor dues. ( iv ) minimun one transformer shall be produce to contractor for restand / repair for one visit. contractor will not demand all job in one visit. visit and repair charges of electrician and helper are included in the quoted rate. no extra charges paid to contractor. ( v ) strip opening of transformer for detecting fault shall be included in the quoted rate. no extra amount shall be paid to the contractor. note : ( i ) gasket, copper / aluminum thimble, ht / lt tape for any size of transformer will be included in the quoted rate . no extra amount shall be paid to the contractor for the same. ( ii ) lt / ht rod , transformer oil and insulator shall be measured and paid seperately. 39 material and labour for disconnecting all the transformer connection ( indoor / outdoor, plinth / pole mounted any type anywhere ) and carry transformer to other location ( top ii yard ) and shifting other transformer to the location of fault under the arrangement of contractor and connecting all the connection and make the light serviceable / functional complete all as specified and as directed. note : all tools, plants and vehicle for lifting and carrying shall be arranged by the contractor and not extra payment shall be paid to the contractor for the same. 40 material and labour for preparing mild steel sheet board 1.6mm thick 30cm x 20 cm having letter written with white paint ( man on work / shut down ) complete with hanging arrangement on vcb for shut down procedure complete all as specified and as dirrected. 41 excavates and relaying ht cables loops near the poles , transformers, vcb , cutting the damages / burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by engineer in charge. 42 material and labour for scraping out old paint and apply new painting to fire stand including fire bucket and fire bitter / fire hooks with red oxide and wiriting word as per direction by je / engr in charge with white paint complete all as specified and as directed. 43 dismantling the old and fainted equipment history sign board at installations in replacement and fabricated the new sign board not less than 2.25 feet in width and 4 feet in length printed with white stickers with complete detail of machinery ( ie name of installstion, date of installstion, sm no, mes no, capacity of the mechanary , date of manufacturer, initial amount , machinery supplied by the firm, job no, ca no, other requirements as directed ) made of aluminium composit panel not less than 3.0 mm thick duly company painted with the mes blue colour one side and grey colour other side computerised printing white strikers as on blue side for marking the name of installations, duly border with red colour tape as per site requirement and framed with aluminium binder in respect of different locations and installations under ge nams. fixing the same on wall of installations with proper alignment using necessary fasterner with nuts, bolts and washers all as specified and directed by engr in charge. 44 material and labour for prepairing , distrubution diagram of external services / sub stn diagram and make flex board of size not less than 1500mm x 1200mm complete with hanging arrangement on wall all as specified and as directed. 45 material and labour in replacement for framing of soft wood notice sign board of size 1200 mm x 1200 mm duly framed with 40 mm x 20 mm teek wood fixed with hassan cloth dark green / navy blue in colour fixed and stiched on the board properly in corporated with hanging arrangement with 02 nos hooks complete in all respected as specified and directed by engr in charge 46 supply and fixing in replacement fault alarm complete all as specified. 47 supply and fixing in replacement tap change in progress alarm complete all as specified. 48 supply and fixing in replacement emergency stop complete all as specified. 49 supply and fixing in replacement ryb indicator complete all as specified. 50 supply and fixing in replacement selector switch make kaybee complete all as specified. 51 supply and fixing in replacement of amp meter dm 3 252 complete all as specified. 52 supply and fixing in replacement of 11kv support insulator suitable for 11kv vcb ( vcb make areva, kirloskar & cg ) , dismantling and mantling of vcb panel labour charge, high quality 11kv vcb busbar insulation material and nutbolts included in quoted rates complete all as specified 53 supply and fixing, in replacement, air breather with silica gel as per existing suitable for 6 / 8 mva transformers main oil tank complete all as specified and directed. 54 supply and fixing, in replacement, air breather with silica gel as per existing suitable for 6 / 8 mva transformers oil conservator tank complete all as specified and directed. 55 m & l for in repair / replacement xlpe insulated , screened, pvc bedded, galvanised steel strip armoured electric power cable ( heavy duty ) with aluminium conductor, 11000 volts , grade cross sectional area 185 sqmm 3 core complete all as specified. 56 s & f in replacement end termination joint heat shrinkable of any size suitable for 3 core 11000 volts xlpe ht ug cable of size 95 sq mm to 120 sq mm complete all as specified and directed. 57 supply and fixing in replacement of auxalary switch 8 no + 8nc complete all as specified. 58 supply and fixing in replacement trip coil assembly 24v dc complete all as specified. 59 supply and fixing in replacement of contactor coil 220 volt dc complete all as per existing complete all as specified. 60 supply and fixing in replacement of pla relay of 220 volts dc , 04 mo, 04 nc complete all as specified. 61 supply only heavy duty ( suitable for ht ) copper thimble of size 120 to 185 sqmm complete all as specified. 62 supply and fixing in replacement three phase over current + earth fault digital relay with high set mc 61 anx, 4000, volts 24 240 ac / dc type mc 61 anx 4 no, make l&t or equivalent complete with wiring all as specified. 63 supply and fixing in replacement of muster trip relay voltage 220 volt dc vaz type of model no vaz 413yf67b, make areva or equivalent. 64 m& l for blue silica gel transformer breather 500 gm suitable for transformer of upto capacity 630 kva complete all as specified and as directed. 65 supply and fixing in replacment of hrc fuse cap 4 amp suitable for 11 kv vcb dc circuit all as specified and directed by engr in charge. 66 supply and fixing in replacment of hrc fuse cap 10 amp suitable for 11 kv vcb dc circuit all as specified and directed by engr in charge. 67 taking out existing gravels / hardcore material from the bottom of substn / equipment completely for cleaning and spraying of anti grass chemical and screnning the hardcore material and refill the same at places complete all as specified and directed by engr in charge. note: anti grass chemical and loose filling of aggregate for topping up will be measured and paid separetly respective item of boq. 68 supply & fixing in replacement disc type polymer insulator including fiixing arrangement ( steel straps, washers and nut and bolt ect ) for 11000 volts grade, including removal of existing insulators complete all as specified and directed. 69 supply and spraying anti vegetation chemical liquid of 1ltrs bottle mixed with water as per direction of engr in charge . note : complete anti vegeration chemical shall be deposit in advance and will be sprayed by the contractor labour as per direction and location where directed. 70 s&f in replacement 70sqmm ht 11kv single core heavy duty insulated cable from top disc insulator to god and disc to disc in any lenth with complete nuts & thimbles all as required at site. 71 s & f in replacement end termination joint heat shrinkable of any size suitable for 3 core 11000 volts xlpe ht ug cable of size 120 sq mm to 185 sq mm complete all as specified and directed. 72 material and labour straight through joint kit of heats shrinkable suitable for 120 sqmm to 185 sqmm ht 3 core 11000 volts xple cable type complete all as specified and directed. 73 replacement of old pcc pole and supply and erect new steel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts & screws as specified type 410 sp 55 ( 11 mtr long ) erecting in position all as specified / shown on drawing and as directed by engr in charge note: ( i ) excavation earth work and foundation will be measured and paid seperately under relevent items. 74 m & l in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint. 75 material and labour for disconneting of air break switch from the old pcc pole and refixing the same on the new steel tubular pole with new clamps and channel and reconnecting the same complete with applying grease to the links all as specified and as directed . 76 material and labour for top up of deficient transformer oil in transformer of any cap having dielectric strength not less than 60 kv at 4 mm gap conforming to is complete all as specified and directed. 77 supply and replacement brass stud for lt side suitable for transformers upto 600 kva. 78 supply and replacement ht 11 kv bush rod suitable for indoor / outdoor type upto 600 kva transformer complete with brass stud, brass nuts, brass cup and packing gasket complete all as spd and directed. 79 m&l for re use un reinforced precast concrete cable cover laid flat in trenches over the cable with length of cover perpendicular to the direction of cable adjacent / abutting each other item retrieved from srl item no 56 above complete all as specified and as directed. 80 material and labour for reconditioning of battery complete with changing of positive and negative cells and battery outer cover and terminals compelte with checking voltage 2 v to 2.2 v , 150 180ah all as specified and as directed 81 material and labour for preparation of rig / battery bank cage , suitable for fitting of 14 battery , 2 volt each made of ms iron flat and angle iron 40x40x6mm having provision of top cover and locking system including lock and 2 keys and fixed in ground upto 25 cm grouted in ground and min 25 cm above ground complete all as specified and as directed. 82 material and labour for replacement of ht copper bus bar 1200 amp, suitable for ht vcb used for common bus bar in vcb panel including cutting as per site and making holes for cable connectiona complete with ht insulation as per colour coding ryb and as required at site complete all as specified and as directed. 83 supply and install heavy duty battery charger 24 v suitable for charging of battery bank of vcb complete all as specified and as directed. 84 routine testing of 66 kv assets by power grid corporation of india / pseb or authorised rep of manufacturer to be tested are as under ; ( a ) transformer 66 kv 6.3 / 8 mva 01 tests to be carried out ( i ) ir value test of both transformer and bushings. ( ii ) pi value test for 20 seconds and 120 seconds. ( iii ) no load current test ( iv ) magnetic balance test. ( v ) short circuit test. ( vi ) testing of tap changer. ( vii ) tan / delta test of transformer. ( viii ) dielectric strength of transformer oil ( xi ) dissolved gas analysis test 66 kv sf 06 breaker ( 02 nos ) tests to be carried out by the power grid corporation of pseb protectiion team. following test shall be carried out : ( i ) ir value both in open and close position. ( ii ) continuity of breaker in closed position. ( iii ) tripping and closing of breaker. ( iv ) functioning of all the tripping system / relays displayed on the control relay panel such as differential o / c, earth fault, metering circuits and all other protection emanating from transformer oil temp trip, oltc trip, winding temp gauge trip, bucholz relay, inter trip etc, calibration of all the relays and complete panel for time observed with respect to time setprimary injection of all the cts, complete all as specified and directed. ( v ) greasing / oiling of all the moving parts. ( vi ) operation / working of charging motor and limit switch. testing of 11kv, vcb breaker 14 nos through power grid corporation of india pseb. the equipments to be tested through protection team pseb are as under: ( a ) following tests to be carried out on each breaker ( nos of breaker 12 nos ) ; ( i ) ir value for open / close circuit fault relay, over load earth fault relay etc ( ii ) tripping and closing time in m / s. ( iii ) operation both manual and through motor. ( iv ) functioning of indicators. ( v ) continuity. ( vi ) ct ration through primary injection. ( vii ) polarity test. ( viii ) testing of all the protection relay i.e. o / c, earth fault, instantaneous, trip suspension, auxiliary relay etc. ( ix ) operation / working of charging motor and limit switch. ( x ) calibration of all relay, male, female contracts of vcb. notes : ( i ) any part / spare found defective during testing shall be repaired / replaced for which payment shall be made separately against respective items here in after. ( ii ) test sheet shall be prepared as specified under ps clause and shall be produced. 85 routine testing of 66 kv assets by power grid corporation of india / pseb or authorised rep of manufacturer to be tested areas under ; ( a ) transformer 66 kv 6.3 / 8 mva 01 tests to be carried out ( i ) ir value test of both transformer and bushings. ( ii ) pi value test for 20 seconds and 120 seconds. ( iii ) no load current test. ( iv ) magnetic balance test. ( v ) short circuit test. ( vi ) testing of tap changer. ( vii ) tan / delta test of transformer. ( viii ) dielectric strength of transformer oil ( xi ) dissolved gas analysis test 66 kv sf 06 breaker ( 01 nos ) tests to be carried out by the power grid corporation of pseb protectiion team. following test shall be carried out : ( i ) ir value both in open and close position. ( ii ) continuity of breaker in closed position. ( iii ) tripping and closing of breaker. ( iv ) functioning of all the tripping system / relays displayed on the control relay panel such as differential o / c, earth fault, metering circuits and all other protection emanating from transformer oil temp trip, oltc trip, winding temp gauge trip, bucholz relay, inter trip etc, calibration of all the relays and complete panel for time observed with respect to time setprimary injection of all the cts, complete all as specified and directed. ( v ) greasing / oiling of all the moving parts. ( vi ) operation / working of charging motor and limit switch. notes : ( i ) any part / spare found defective during testing shall be repaired / replaced for which payment shall be made separately against respective items here in after. ( ii ) test sheet shall be prepared as specified under ps clause and shall be produced. 86 testing of 11kv breaker through power grid corporation of india , through pseb protection team are as under: ( nrc map ph ii ) ( a ) tests to be carried out on each breaker ( nos of breaker five in nrc ii ) 87 testing of 11kv breaker through power grid corporation of india , through pseb protection team are as under: ( kathania map ph ii ) ( a ) tests to be carried out on each breaker ( five in kathania ii ) 88 testing of 11kv breaker through power grid corporation of india , through pseb protection team are as under: ( khterpal map ph ii ) ( a ) tests to be carried out on each breaker ( nos of breaker nine in khterpal ii ) 89 testing of 11kv breaker through power grid corporation of india , through pseb protection team are as under: ( noc map ph ii ) ( a ) tests to be carried out on each breaker ( nos of breaker three in noc ii ) 90 testing of 11kv breaker through power grid corporation of india , through pseb protection team are as under: ( nme map ph ii ) ( a ) tests to be carried out on each breaker ( nos of breaker one in nme ph ii ) the following tests are carried out srl no 86 to 90 ( i ) ir value for open ( ii ) tripping and closing time in m / s. ( iii ) operation both manual and through motor. ( iv ) functioning of indicators. ( v ) continuity. ( vi ) ct ration through primary injection. ( vii ) polarity test. ( viii ) testing of all the protection relay i.e. o / c, earth fault, instantaneous, trip suspension, auxiliary relay etc. ( ix ) operation / working of charging motor and limit switch. ( x ) calibration of all relay, male, female contracts of vcb. note : ( i ) any part / spare found defective during testing shall be repaired / replaced for which payment shall be made separately against respective items here in after except for minor parts such as packing, nuts bolts, cotton waste etc for which cost shall be deemed to be included in the unit rate quoted for this item. ( ii ) test sheet shall be prepared and produced to engr in charge. ( iii ) t&p / power back up / dc supply required for testing shall be provided by the contractor. 91 testing of 11kv breaker through power grid corporation of india , through pseb protection team are as under: ( top i ) ( a ) following tests to be carried out on each breaker ( nos of breaker seven in top i ) ( i ) ir value for open ( ii ) tripping and closing time in m / s. ( iii ) operation both manual and through motor. ( iv ) functioning of indicators. ( v ) continuity. ( vi ) ct ration through primary injection. ( vii ) polarity test. ( viii ) testing of all the protection relay i.e. o / c, earth fault, instantaneous, trip suspension, auxiliary relay etc. ( ix ) operation / working of charging motor and limit switch. ( x ) calibration of all relay, male, female contracts of vcb. note : ( i ) any part / spare found defective during testing shall be repaired / replaced for which payment shall be made separately against respective items here in after except for minor parts such as packing, nuts bolts, cotton waste etc for which cost shall be deemed to be included in the unit rate quoted for this item. ( ii ) test sheet shall be prepared and produced to engr in charge. 92 testing of 11kv breaker through power grid corporation of india , through pseb protection team are as under: ( top ii ) ( a ) following tests to be carried out on each breaker ( nos of breaker nine in top ii ) ( i ) ir value for open ( ii ) tripping and closing time in m / s. ( iii ) operation both manual and through motor. ( iv ) functioning of indicators. ( v ) continuity. ( vi ) ct ration through primary injection. ( vii ) polarity test. ( viii ) testing of all the protection relay i.e. o / c, earth fault, instantaneous, trip suspension, auxiliary relay etc. ( ix ) operation / working of charging motor and limit switch. ( x ) calibration of all relay, male, female contracts of vcb. note : ( i ) any part / spare found defective during testing shall be repaired / replaced for which payment shall be made separately against respective items here in after except for minor parts such as packing, nuts bolts, cotton waste etc for which cost shall be deemed to be included in the unit rate quoted for this item. ( ii ) test sheet shall be prepared and produced to engr in charge....

Punjab State Power Corporation Limited - Punjab

34216414 supply of 66kv line control & relay panels 66 kv line cr panel cl1p scada 120 nos 66 kv line cr panel cl1p scada , 66kv line control & relay panel cl1p scadaw.r.t. te 266 / ssd 143 / 2022...

Rail Coach Factory - Punjab

26922872 supply of , supply,erection,testing & commissioning of control & relay panel for 25 kv outgoing feeder consisting of over current & earth fault relay(ocr &efr) type antp202 hv/lv &master trip relay aems 32 alind make or equivalent rdso make as per rdso specfication no ti/spc/psi/protct/6071 as per enclosed drawing no. rcf/el/25kv/cb 01&02 including all charges, as per latest rdso spec. no. ti/spc/psi/protct/6071, with a&c slip no 01 or latest...

Northern Railway - Punjab

26604358 supply of , digital voltmeter suitable for numerical control & relay panel as per is 3875 ( part1 3) specification ptr 27.5/110v ac (programmable), range; 0 20 v ac, display; 0 30 kv ac, aux supply; 110v dc & ac, acc, class; 0.5 and size 48x96mm make; rishab or similar...

Bhakra Beas Management Board - Punjab

10647927 online tender for supply, one no. control relay panel of 4 mva, 66 / 11kv transformer with accessories including packing, forwarding and commissioning at beas dam project...

Bhakra Beas Management Board - Punjab

10525435 supply, one no. control relay panel of 4 mva, 66 or 11kv transformer with accessories ic packing, forwarding and commissioning at beas dam project...

Bhakra Beas Management Board - Punjab

10308703 supply, one no. control relay panel of 4 mva, 66 or 11kv transformer with accessories ic packing, forwarding and commissioning at beas dam project...

Bhakra Beas Management Board - Punjab

10108884 supply, one no. control relay panel of 4 mva, 66 or 11kv transformer with accessories ic packing, forwarding and commissioning at beas dam project...

Bhakra Beas Management Board - Punjab

10049490 design, manufacture, supply, erection, testing, and commissioning of control & relay ( c&r ) panels for replacing existing c&r panels of unit no. i, ii, iv to vi with latest c&r panels having numerical generator & generator t / f protection , control panel of unit no. iii and common items for all six units such as control desks and synchronizing panel / equipment at pong power house, talwara....

Bhakra Beas Management Board - Punjab

9872513 online tender for supply, one no. control relay panel of 4 mva, 66 or 11kv transformer with accessories ic packing, forwarding and commissioning at beas dam project...

Bhakra Beas Management Board - Punjab

9721020 online tender for supply, one no. control relay panel of mva, 66 or 11kv transformer with accessories ic packing, forwarding and commissioning at beas dam project...

Bhakra Beas Management Board - Punjab

9716953 supply, one no. control relay panel of mva, 66 / 11kv transformer with accessories including packing, forwarding and commissioning at beas dam project...

Bhakra Beas Management Board - Punjab

9459857 design, manufacture, supply, erection, testing, and commissioning of control & relay ( c&r ) panels for replacing existing c&r panels of unit no. i, ii, iv to vi with latest c&r panels having numerical generator & generator t / f protection , control panel of unit no. iii and common items for all six units such as control desks and synchronizing panel / equipment at pong power house, talwara...

Northern Railway - Punjab

2543657 provision of additional control & relay panel alongwith modification in scada system due to 3rd line (murinda sahnewal ludhiana section) along with fault diagnostic kit....

Northern Railway - Punjab

2280114 provision of additional control & relay panel along with modification in scada system due to 3rd line....

Northern Railway - Punjab

2234831 up gradation of scada system with numerical relays and control & relay panel for butari/traction sub station....