Military Engineer Services - Punjab
37267106 tender for maintenance / repair of ceiling fans and other fans and electric meters at zone a and zone m under age e / m v of ge north bathinda at bathinda mil stn...
37267106 tender for maintenance / repair of ceiling fans and other fans and electric meters at zone a and zone m under age e / m v of ge north bathinda at bathinda mil stn...
37267102 tender for maintenance / repair of ceiling fans and other fans and electric meters at zone b under age e / m v of ge north bathinda at bathinda mil stn...
36481869 bids are invited for hardware items mse laptop , finger print reader , electric meter total quantity : 4...
35980546 bids are invited for ceiling fan 1200 mm sweep including fan blade down rod canopy ect makke polycab or havells or orient , electric meter single pace 230 volt 10 to 40 ampr make benlo or neptune or hpl , exhaust fan 230 volt metal body 300 mm sweep make polycab or havells or orient , ac window type 1 point 5 tr capacity 5 star rating make blue star or volts or lg , ac split type 2 tr capacity 5 star rating make blue star or volts or lg , desert cooler metal body including fan moter fan blade make khaitan or cg or symphony...
35811376 tender for provision of mob equipment stores for med regt ( fd regt ) and rewiring of bldg no. p 67 ( 12 qtrs ) or md accn of engr regt at 550 acre under ge ( east ) ferozepur cantt b / r workexcavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, for lying cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft loose soil complete all as specified and as directed. 2 m&l cement concrete in foundations 1:4:8 type d 2, ( 40mm graded stone aggregate as in sub base of foundation, filling and mass concrete complete all as specified and as directed. 3 m&l for brickwork with subclass ‘b’ bricks, straight or curved on plan exc 6m mean radius built in cm ( 1:6 ) complete all as specified and as directed. 4 returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm soft / loose soil complete all as specified and as directed. 5 removing excavated material / soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. 6 use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or to batter rough finishedsurface of concrete complete all as specified and as directed. 7 use and waste of formwork to sides of pillars, posts, struts, piers, columns etc rough finishedsurface of concreteall as complete all as specified and as directed. 8 use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick ( horizontal or sloping ) rough finishedsurface of concrete complete all as specified and as directed. 9 use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of rcc / pcc bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm widerough finishedsurface of concretecomplete all as specified and as directed. 10 use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finishedsurface of concretecomplete all as specified and as directed. 11 m&l rcc design mix m 25 ( using 20mm graded stone aggregate ) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and as directed. 12 m&l rcc design mix m 25 ( using 20mm graded stone aggregate ) columns, pillars, piers, posts and struts complete all as specified and as directed. 13 m&l rcc design mix m 25 ( using 20mm graded stone aggregate ) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. 14 m&l rcc design mix m 25 ( 20mm graded stone aggregate ) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. 15 m&l mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 16 all as per item no 15 above but 5mm dia and over upto and incl 10mm dia in stirupps, spacers and binders etc complete all as specified and as directed. 17 m&l rendering 12mm thickin cement mortar ( 1:4 ) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. 18 m&l rendering 15mm thickin cement mortar ( 1:6 ) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. 19 m&lrendering 10 mm thick cement plaster on ceiling surfaces in cement mortar 1:4 finished fair and evenwithout using extra cement complete all as specified and as directed. 20 supply only integral water proofing compound conforming is 2645 1975 of approved make complete all as specified and as directed. 21 m&l preparation of newly plastered surfaces of walls etc, and applying three coats of white wash complete all as specified and as directed. 22 m&l preparation of new plastered surfaces of ceiling & applying two coats of white wash complete all as specified and as directed. 23 m&l applying double coats of bitumen elastometric waterproof coating as on damp proof course / roof including cleaning of surfaces complete all as specified and as directed. 24 m&l 75mm thick cement concrete 1:4:8 type c 2, using 40mm graded brick aggregate as in sub floor, sub base etc, finishing surfaces rough to receive the topping layer all as complete all as specified and as directed. 25 m & l machine pressed precast conctete interlocking paver block any shape and size confirming to is 15658 2006 of 60 mm thickness m 35 grade, jointed and pointed with gray cement and no pigment over sand cushioning complete all as specified and directed. 26 m & l sand filling under floors or in foundations including watering and consolidationcomplete all as directed by engieer in charge . 27 m&l 75mm thick cement concrete ( 1:3:6 ) type c 1 using 20mm graded stone aggregate as in plinth protection, surfaces finished even and fair without using extra cementincluding provision of construction joints complete all as specified and as directed. 28 m&l 75 mm thick cement concrete ( 1:2:4 ) type b 2 using 40mm graded stone aggregate as in floor topping, surface finished even and smooth without using extra cement complete all as specified and as directed. 29 m&l glass dividing strips, 3 mm thick and 38mm width of strip, inserted in position, conform to design complete all as specified and as directed. 30 s&f pressed steel frames ( 1.25mm sheet thickness ) for doors with one or more rebates including necessary fixing lugs , hinges, lock plate, etc., size of frame 105mm x 60 mmincluding one shop coat of red oxide primer complete all as specified and as directed. 31 s&f of 40mm thick flush door shutter of solid core construction with particle board core and plywood face panels, commercial type on both sides one face is covered with decorative face veneerwith lipping / frame to match complete all as specified and as directed. 32 s&f factory made box type steel window with pintal hinges & 2 nos 150 mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on drawing no cejz / td 06 / 07 & cejz / td 07 / 07. 33 s&f factory made box type steel window with pintal hinges & 2 nos 150 mm mild steel tower bolts to each shutter, steel handle and withoutglazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on drawing no cejz / td 06 / 07 & cejz / td 07 / 07. 34 s&f steel ventilators fixed type complete with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and as directed. 35 mild steel framed work of e 165 ( fe 290 ) as in grills / guard bars shouldered with steel window / ventilator frames including red oxide primer coat complete all as specified and as directed. 36 s&f mild steel door handles, stove enameled black, medium wt 125 mm long and fixed with steel screws complete all as specified and as directed. 37 s&f mild steel barrel tower bolts, stove enameled black, with bright bolt, medium weight 150 mm long and fixed with steel screws complete all as specified and as directed. 38 s&f 300 mm long mild steel, sliding door bolt, plate type, stove enameled black, with bright bolt not less than 12 mm dia with and including bolts and nuts complete all as specified and as directed. 39 s&f 3 mm thick, plainsheet glass ordinary quality and glazing, with oil putty or with wooden beads ( supplied alongwith shutters ) , in squares n.exc 0.50 sqm complete all as specified and as directed. 40 s&f stainless steel wire cloth0.56 mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staplescomplete all as specified and as directed. 41 m&l cement concrete ( 1:3:6 ) type c 1 using 20 mm graded stone aggregate as in fillings and mass concrete, filling backs of chowkats etc, complete all as specified and as directed. 42 m&l preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed. 43 m&l preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and as directed. 44 m&l preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paintcomplete all as specified and as directed. 45 e / m worksm&l for point wiring with 1.5 sqmm ( nominal area ) , pvc insulated, frls multistranded, single core unsheathed, copper conductor cables drawnthrough and including pvc conduit with allaccessories concealled in wall and fixed to ceiling etc. with and including 1.5 sqmm ( nominal area ) pvc insulated, frls unsheathed, multi stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth dolly including sunken boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light / fan / bell point controlled by one , one way switch all as specified and directed. ( a ) one light point / fan point / exhaust point controlled by one single pole one way switch. ( note: wiring shall be done in colour coding ) 46 all as per item no 45 hereinbefore butone 3 pin socket outlet 5 amps independent boardcomplete all as specified and as directed. 47 all as per item no 45 hereinbefore but one 3 pin socket outlet 5amps on the same board with other switches complete all as specified and as directed. 48 all as per item no. 45 here in before but one 15 amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 sqmm pvc insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 sqmm green colours pvc insulated, unsheathed, stranded copper conductor cable. 49 all as per item no. 45 here in before but one 15 amps socket outlet point controlled by one single pole switch one way and wiring with 4.0 sqmm pvc insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 4.0 sqmm green colours pvc insulated, unsheathed, stranded copper conductor cable. 50 s&f switch piano flush type 6 amps, single pole one way, white in colour, duly isi marked complete all as specified and directed. 51 s&f switch piano flush type 20 amps, single pole one way, white in colour, duly isi marked complete all as specified and directed. 52 s&f socket outlet2 in 1, 5 pin, 6 amps, white in colour, duly isi marked complete all as specified and directed. 53 s&f socket outlet, uni, 2 in one10 amps & 20 amps, white in colour, duly isi markedcomplete all as specified and directed. 54 s&f ceiling rose surface type, 240 volts, 50 hz, 6a, pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals dulyisi marked complete all as specified and directed. 55 s&f rotary stepped type electronic fan regulator for ceiling fan 1200 / 1400mm size, 240 volts, 6 amps, 100w, white in colour, duly isi marked complete all as specified. 56 s&f lamp angle holder ( plastic ring ) , 240 volts, 50 hz, 6a, white in colour, duly isi marked complete all as specified and directed. 57 s&f led bulb of 9 watt, b22, 6500k all as specified and directed. 58 s&f 20w, 6500 k, 4 feet led square tube light fitting, energy efficient fixed to wall / ceiling etc complete all as specified and as directed. 59 s&f led sleeky bldg street light ( lens ) fitting of 35 watts, 6000k, including gi bracket bend to shape made out of gi pipe light grade of 25 mm, size up to 1.2 mtr long etc complete with ms clamps made of 25x3mm ms plate, duly painted with two coats of aluminium paint with nuts / bolts / washers and all fixing arrangements to wall / pole, including connecting up with 2 core copper flexible wire of size 23 / 00.0076 complete all as specified and as directed. 60 s&f exhaust fan heavy duty with louvers complete of sweep size 300mm, 900 rpm, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of pvc flexible copper cable of size 23 / 00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and as directed. 61 s&f ceiling fan 1200mm sweep, ac single phase 230 volts 50hz, at bldgs upto 5 mtrs height, including provision of flexible cable 3 core copper conductor of size 23 / 0.0076 of suitable length from ceiling rose to ceiling fan upto 1.5 mtr for giving connection and all hanging arrangement i.e. standard down rod, hanging clamp, with rubber real nuts bolts, spring washers and locking of splite pin, plastic canopy with screw compete without fan regulator and marking of mes nos with black synthetic enameled paint all as specified and as directed. 62 s&f factory made sheet metal enclosures double door type made out of crca 1.2 mm thick m.s. sheet, powder coated, partly embedded in wall, ip 43 protection, vtpn db with 200 amps rated bus bar, 4 way, 415 volts, vertical type, dust and vermin proof, suitable for incorporation of mccbs / mcbs, factory made, including thermal based release adjustable type 4 pole 63 amps, 50 hz, 415 volts with rupturing capacity 16 ka and making good distrubbed surfaces with matching colour, complete all as specified and as directed. 63 s&f factory made sheet metal enclosures double door type made out of crca1.2 mm thick m.s sheet, powder coated, spn db with 200 amps rated bus bar, 8 way, ip 42 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of mcbs duly cocealled in wall, factory made, including making good distrubbed surfaces with matching colour complete all as specified and as directed. 64 s&f mcb spn, 40 amps, 240 volts, b series, 10ka duly isi marked, complete all as specified and as directed. 65 s&f mcb sp, 6a 32 amps, 240 volts, b series, 10ka duly isi marked, complete all as specified and as directed. 66 m&l for sub main wiring with two single core 2x4 sqmm pvc insulated and unsheathed stranded copper conductoralongwith earth wire 4.0 sqmm drawn in including pvc rigid conduit connected to main board complete all as specified and directed ( note: two runs cable and one number earth wire and suitablepvc conduit shall measured together as unit length ) . 67 m&l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire complete all as specified and as directed. 68 m&l for earthing complete with galvanized steel plate elecrode of size60 cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead gi wire of 4mm dia ( 8 swg ) by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles. the other end of gi earth wire is connected to main switch board and protected by light grade gi pipe of 15 mm bore. provision of 20mm bore light grade gi pipe for watering including gi funnel and wire mesh. pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. cement concrete chamber of pcc ( 1:3:6 ) type c 2 using 40 mm graded stone aggregate.the chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete ( 1:2:4 ) type b 1 using 20 mm graded stone aggregate and ms angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to exposed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in electrical plate no 3 of ssr part 1 ( 2009 ) . 69 supplying, laying, jointing and testing xlpe insulated, armoured, electric cables ( heavy duty ) with aluminium conductor, 1100 volts, grade cross sectional area 25 sqmm 4 core confirming to is:7098 1985 laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and as directed. ( note: excavation & earth work, cable preotection coverand sand cushion shall be measured &separately ) 70 m&l dry and clean fine sand for cable cushioningto underground cable protection, complete all as specified and as directed. note punned down thickness shall be measured. 71 s&f cover to underground cable with one layer of bricks using sub class ‘b’ bricks ( old size ) laid flat across the cable complete all as specified and as directed. 72 s&f mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles / walls, laid under floor / road crossings, complete with and includingclamps socket & elbow etc complete all as specified and as directed. 73 taking down carefully existig copper / alumn point wiring for light / fan / bell / socket 5 / 15 amp points complete withfitting and fixtures such as switches, sockets, c / rosess, holders and bracket fittings with battens / conduits / wires, t / l fittings and making good the disturbed surfacesof walls and roofs etc.and to match with existing colour complete all as specified and directed. 74 taking down carefully unserviceable main switches and distribution boards with fuses / mcbs ( single phase or three phase ) of any capacity complete all as specified and as directed. 75 taking down carefully old unserviceable sub main wiring including meters and making good disturbed surfaces and matching with existing complete all as directed and specified 76 s&f bell push flush, type 6 amp single pole one way, white in colour, duly isi marked complete all as specified and as directed. 77 s&f door bell ding dong single phase 240 volts, white in colour, duly isi marked complete all as specified and as directed. 78 s&f batten holder ( with metal ring ) , 240 volts, 50 hz, 6a, white in colour, duly isi marked complete all as specified and as directed. 79 s&f factory made three phase and neutral sheet steel made out of crca 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing mcbs and the second for protection of mcbs fitted with colour bus bar of capacity 200 amps, neutral link, earth bar and din rail suitable for use on 240 / 415v, 50hz supply, vtpn db, partly immersed in wall, including of mccb 4 pole adjustable thermal & fixed magnetic type 100 amps, 50hz, 415 volts with rupturing capacity 16 ka and making good distrubbed surfaces with matching colour, complete all as specified and as directed. 80 s&f mcb spn, 40a 63amps, 240 volts, c series, 10ka duly isi marked, in mcb db, complete with connection testing and commissioning complete all as specified and as directed. 81 m&l for sub main wiring with two single core 2x6 sqmm frls insulated and unsheathed stranded copper conductoralongwith earth wire 6.0 sqmm frls drawn in includingrigid conduit connected to main board complete all as specified and directed ( note: two runs cable and one number earth wire and suitableconduit shall measured together as unit length ) . 82 cutting holes making good the distributed surface, grouting nuts for fixing of exhaust fans complete all as specified and directed. 83 m&l for disconnecting electric meter of any cap and refixing same after rewiring, in meter box including connection complete all as specified and as directed. 84 s&f sheet metal meter box single door minimum size 35x50x25cm for electric meter factory made of ms sheets / crca sheet duly painted with powder paint and door hinged locking arrangement conforming to is 5039 of 1983. the electric meter / switch box shall be suitable for fixing one number of electric meter and knock out holes for incoming and outgoing cable. before the powder paint process the sheet steel shall go through the anti corrosion conditioning process in not less than seven tank process. concealed in wall, including making good distrurbed surfaces with matching colour, complete all as specified and as directed. 85 fixing or hanging only ceiling fans height upto 3mtr to 5 mtrs ceiling height of bldg including three core fr pvc insulated & overall round sheathed flexible with pvc, colour of cores are red, black & yellow / green is for earthing. sheath colour is black of cable size 23 / 0.0076 complete all as specified. ( note : ceiling fans obtained / taking down from item sr no.73 as above ) ...
35777465 bids are invited for ceiling fan 1200 mm sweep including fan blade down rod canopy ect makke polycab or havells or orient , electric meter single pace 230 volt 10 to 40 ampr make benlo or neptune or hpl , exhaust fan 230 volt metal body 300 mm sweep make polycab or havells or orient , ac window type 1 point 5 tr capacity 5 star rating make blue star or volts or lg , ac split type 2 tr capacity 5 star rating make blue star or volts or lg , desert cooler metal body including fan moter fan blade make khaitan or cg or symphony mse total quantity : 480...
35373251 tender for provision of mob equipment stores for medical regt ( fd regt ) and rewiring of bldg no. p 67 ( 12 qtrs ) or md accn of engr regt at 550 acre under ge ( east ) ferozepur cantt / r workexcavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, for lying cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft loose soil complete all as specified and as directed. 2 m&l cement concrete in foundations 1:4:8 type d 2, ( 40mm graded stone aggregate as in sub base of foundation, filling and mass concrete complete all as specified and as directed. 3 m&l for brickwork with subclass ‘b’ bricks, straight or curved on plan exc 6m mean radius built in cm ( 1:6 ) complete all as specified and as directed. 4 returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm soft / loose soil complete all as specified and as directed. 5 removing excavated material / soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. 6 use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or to batter rough finishedsurface of concrete complete all as specified and as directed. 7 use and waste of formwork to sides of pillars, posts, struts, piers, columns etc rough finishedsurface of concreteall as complete all as specified and as directed. 8 use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick ( horizontal or sloping ) rough finishedsurface of concrete complete all as specified and as directed. 9 use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of rcc / pcc bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm widerough finishedsurface of concretecomplete all as specified and as directed. 10 use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finishedsurface of concretecomplete all as specified and as directed. 11 m&l rcc design mix m 25 ( using 20mm graded stone aggregate ) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and as directed. 12 m&l rcc design mix m 25 ( using 20mm graded stone aggregate ) columns, pillars, piers, posts and struts complete all as specified and as directed. 13 m&l rcc design mix m 25 ( using 20mm graded stone aggregate ) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. 14 m&l rcc design mix m 25 ( 20mm graded stone aggregate ) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. 15 m&l mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 16 all as per item no 15 above but 5mm dia and over upto and incl 10mm dia in stirupps, spacers and binders etc complete all as specified and as directed. 17 m&l rendering 12mm thickin cement mortar ( 1:4 ) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. 18 m&l rendering 15mm thickin cement mortar ( 1:6 ) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. 19 m&lrendering 10 mm thick cement plaster on ceiling surfaces in cement mortar 1:4 finished fair and evenwithout using extra cement complete all as specified and as directed. 20 supply only integral water proofing compound conforming is 2645 1975 of approved make complete all as specified and as directed. 21 m&l preparation of newly plastered surfaces of walls etc, and applying three coats of white wash complete all as specified and as directed. 22 m&l preparation of new plastered surfaces of ceiling & applying two coats of white wash complete all as specified and as directed. 23 m&l applying double coats of bitumen elastometric waterproof coating as on damp proof course / roof including cleaning of surfaces complete all as specified and as directed. 24 m&l 75mm thick cement concrete 1:4:8 type c 2, using 40mm graded brick aggregate as in sub floor, sub base etc, finishing surfaces rough to receive the topping layer all as complete all as specified and as directed. 25 m & l machine pressed precast conctete interlocking paver block any shape and size confirming to is 15658 2006 of 60 mm thickness m 35 grade, jointed and pointed with gray cement and no pigment over sand cushioning complete all as specified and directed. 26 m & l sand filling under floors or in foundations including watering and consolidationcomplete all as directed by engieer in charge . 27 m&l 75mm thick cement concrete ( 1:3:6 ) type c 1 using 20mm graded stone aggregate as in plinth protection, surfaces finished even and fair without using extra cementincluding provision of construction joints complete all as specified and as directed. 28 m&l 75 mm thick cement concrete ( 1:2:4 ) type b 2 using 40mm graded stone aggregate as in floor topping, surface finished even and smooth without using extra cement complete all as specified and as directed. 29 m&l glass dividing strips, 3 mm thick and 38mm width of strip, inserted in position, conform to design complete all as specified and as directed. 30 s&f pressed steel frames ( 1.25mm sheet thickness ) for doors with one or more rebates including necessary fixing lugs , hinges, lock plate, etc., size of frame 105mm x 60 mmincluding one shop coat of red oxide primer complete all as specified and as directed. 31 s&f of 40mm thick flush door shutter of solid core construction with particle board core and plywood face panels, commercial type on both sides one face is covered with decorative face veneerwith lipping / frame to match complete all as specified and as directed. 32 s&f factory made box type steel window with pintal hinges & 2 nos 150 mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on drawing no cejz / td 06 / 07 & cejz / td 07 / 07. 33 s&f factory made box type steel window with pintal hinges & 2 nos 150 mm mild steel tower bolts to each shutter, steel handle and withoutglazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on drawing no cejz / td 06 / 07 & cejz / td 07 / 07. 34 s&f steel ventilators fixed type complete with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and as directed. 35 mild steel framed work of e 165 ( fe 290 ) as in grills / guard bars shouldered with steel window / ventilator frames including red oxide primer coat complete all as specified and as directed. 36 s&f mild steel door handles, stove enameled black, medium wt 125 mm long and fixed with steel screws complete all as specified and as directed. 37 s&f mild steel barrel tower bolts, stove enameled black, with bright bolt, medium weight 150 mm long and fixed with steel screws complete all as specified and as directed. 38 s&f 300 mm long mild steel, sliding door bolt, plate type, stove enameled black, with bright bolt not less than 12 mm dia with and including bolts and nuts complete all as specified and as directed. 39 s&f 3 mm thick, plainsheet glass ordinary quality and glazing, with oil putty or with wooden beads ( supplied alongwith shutters ) , in squares n.exc 0.50 sqm complete all as specified and as directed. 40 s&f stainless steel wire cloth0.56 mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staplescomplete all as specified and as directed. 41 m&l cement concrete ( 1:3:6 ) type c 1 using 20 mm graded stone aggregate as in fillings and mass concrete, filling backs of chowkats etc, complete all as specified and as directed. 42 m&l preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed. 43 m&l preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and as directed. 44 m&l preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paintcomplete all as specified and as directed. 45 e / m worksm&l for point wiring with 1.5 sqmm ( nominal area ) , pvc insulated, frls multistranded, single core unsheathed, copper conductor cables drawnthrough and including pvc conduit with allaccessories concealled in wall and fixed to ceiling etc. with and including 1.5 sqmm ( nominal area ) pvc insulated, frls unsheathed, multi stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth dolly including sunken boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light / fan / bell point controlled by one , one way switch all as specified and directed. ( a ) one light point / fan point / exhaust point controlled by one single pole one way switch. ( note: wiring shall be done in colour coding ) 46 all as per item no 45 hereinbefore butone 3 pin socket outlet 5 amps independent boardcomplete all as specified and as directed. 47 all as per item no 45 hereinbefore but one 3 pin socket outlet 5amps on the same board with other switches complete all as specified and as directed. 48 all as per item no. 45 here in before but one 15 amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 sqmm pvc insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 sqmm green colours pvc insulated, unsheathed, stranded copper conductor cable. 49 all as per item no. 45 here in before but one 15 amps socket outlet point controlled by one single pole switch one way and wiring with 4.0 sqmm pvc insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 4.0 sqmm green colours pvc insulated, unsheathed, stranded copper conductor cable. 50 s&f switch piano flush type 6 amps, single pole one way, white in colour, duly isi marked complete all as specified and directed. 51 s&f switch piano flush type 20 amps, single pole one way, white in colour, duly isi marked complete all as specified and directed. 52 s&f socket outlet2 in 1, 5 pin, 6 amps, white in colour, duly isi marked complete all as specified and directed. 53 s&f socket outlet, uni, 2 in one10 amps & 20 amps, white in colour, duly isi markedcomplete all as specified and directed. 54 s&f ceiling rose surface type, 240 volts, 50 hz, 6a, pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals dulyisi marked complete all as specified and directed. 55 s&f rotary stepped type electronic fan regulator for ceiling fan 1200 / 1400mm size, 240 volts, 6 amps, 100w, white in colour, duly isi marked complete all as specified. 56 s&f lamp angle holder ( plastic ring ) , 240 volts, 50 hz, 6a, white in colour, duly isi marked complete all as specified and directed. 57 s&f led bulb of 9 watt, b22, 6500k all as specified and directed. 58 s&f 20w, 6500 k, 4 feet led square tube light fitting, energy efficient fixed to wall / ceiling etc complete all as specified and as directed. 59 s&f led sleeky bldg street light ( lens ) fitting of 35 watts, 6000k, including gi bracket bend to shape made out of gi pipe light grade of 25 mm, size up to 1.2 mtr long etc complete with ms clamps made of 25x3mm ms plate, duly painted with two coats of aluminium paint with nuts / bolts / washers and all fixing arrangements to wall / pole, including connecting up with 2 core copper flexible wire of size 23 / 00.0076 complete all as specified and as directed. 60 s&f exhaust fan heavy duty with louvers complete of sweep size 300mm, 900 rpm, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of pvc flexible copper cable of size 23 / 00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and as directed. 61 s&f ceiling fan 1200mm sweep, ac single phase 230 volts 50hz, at bldgs upto 5 mtrs height, including provision of flexible cable 3 core copper conductor of size 23 / 0.0076 of suitable length from ceiling rose to ceiling fan upto 1.5 mtr for giving connection and all hanging arrangement i.e. standard down rod, hanging clamp, with rubber real nuts bolts, spring washers and locking of splite pin, plastic canopy with screw compete without fan regulator and marking of mes nos with black synthetic enameled paint all as specified and as directed. 62 s&f factory made sheet metal enclosures double door type made out of crca 1.2 mm thick m.s. sheet, powder coated, partly embedded in wall, ip 43 protection, vtpn db with 200 amps rated bus bar, 4 way, 415 volts, vertical type, dust and vermin proof, suitable for incorporation of mccbs / mcbs, factory made, including thermal based release adjustable type 4 pole 63 amps, 50 hz, 415 volts with rupturing capacity 16 ka and making good distrubbed surfaces with matching colour, complete all as specified and as directed. 63 s&f factory made sheet metal enclosures double door type made out of crca1.2 mm thick m.s sheet, powder coated, spn db with 200 amps rated bus bar, 8 way, ip 42 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of mcbs duly cocealled in wall, factory made, including making good distrubbed surfaces with matching colour complete all as specified and as directed. 64 s&f mcb spn, 40 amps, 240 volts, b series, 10ka duly isi marked, complete all as specified and as directed. 65 s&f mcb sp, 6a 32 amps, 240 volts, b series, 10ka duly isi marked, complete all as specified and as directed. 66 m&l for sub main wiring with two single core 2x4 sqmm pvc insulated and unsheathed stranded copper conductoralongwith earth wire 4.0 sqmm drawn in including pvc rigid conduit connected to main board complete all as specified and directed ( note: two runs cable and one number earth wire and suitablepvc conduit shall measured together as unit length ) . 67 m&l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire complete all as specified and as directed. 68 m&l for earthing complete with galvanized steel plate elecrode of size60 cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead gi wire of 4mm dia ( 8 swg ) by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles. the other end of gi earth wire is connected to main switch board and protected by light grade gi pipe of 15 mm bore. provision of 20mm bore light grade gi pipe for watering including gi funnel and wire mesh. pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. cement concrete chamber of pcc ( 1:3:6 ) type c 2 using 40 mm graded stone aggregate.the chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete ( 1:2:4 ) type b 1 using 20 mm graded stone aggregate and ms angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to exposed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in electrical plate no 3 of ssr part 1 ( 2009 ) . 69 supplying, laying, jointing and testing xlpe insulated, armoured, electric cables ( heavy duty ) with aluminium conductor, 1100 volts, grade cross sectional area 25 sqmm 4 core confirming to is:7098 1985 laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and as directed. ( note: excavation & earth work, cable preotection coverand sand cushion shall be measured &separately ) 70 m&l dry and clean fine sand for cable cushioningto underground cable protection, complete all as specified and as directed. note punned down thickness shall be measured. 71 s&f cover to underground cable with one layer of bricks using sub class ‘b’ bricks ( old size ) laid flat across the cable complete all as specified and as directed. 72 s&f mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles / walls, laid under floor / road crossings, complete with and includingclamps socket & elbow etc complete all as specified and as directed. 73 taking down carefully existig copper / alumn point wiring for light / fan / bell / socket 5 / 15 amp points complete withfitting and fixtures such as switches, sockets, c / rosess, holders and bracket fittings with battens / conduits / wires, t / l fittings and making good the disturbed surfacesof walls and roofs etc.and to match with existing colour complete all as specified and directed. 74 taking down carefully unserviceable main switches and distribution boards with fuses / mcbs ( single phase or three phase ) of any capacity complete all as specified and as directed. 75 taking down carefully old unserviceable sub main wiring including meters and making good disturbed surfaces and matching with existing complete all as directed and specified 76 s&f bell push flush, type 6 amp single pole one way, white in colour, duly isi marked complete all as specified and as directed. 77 s&f door bell ding dong single phase 240 volts, white in colour, duly isi marked complete all as specified and as directed. 78 s&f batten holder ( with metal ring ) , 240 volts, 50 hz, 6a, white in colour, duly isi marked complete all as specified and as directed. 79 s&f factory made three phase and neutral sheet steel made out of crca 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing mcbs and the second for protection of mcbs fitted with colour bus bar of capacity 200 amps, neutral link, earth bar and din rail suitable for use on 240 / 415v, 50hz supply, vtpn db, partly immersed in wall, including of mccb 4 pole adjustable thermal & fixed magnetic type 100 amps, 50hz, 415 volts with rupturing capacity 16 ka and making good distrubbed surfaces with matching colour, complete all as specified and as directed. 80 s&f mcb spn, 40a 63amps, 240 volts, c series, 10ka duly isi marked, in mcb db, complete with connection testing and commissioning complete all as specified and as directed. 81 m&l for sub main wiring with two single core 2x6 sqmm frls insulated and unsheathed stranded copper conductoralongwith earth wire 6.0 sqmm frls drawn in includingrigid conduit connected to main board complete all as specified and directed ( note: two runs cable and one number earth wire and suitableconduit shall measured together as unit length ) . 82 cutting holes making good the distributed surface, grouting nuts for fixing of exhaust fans complete all as specified and directed. 83 m&l for disconnecting electric meter of any cap and refixing same after rewiring, in meter box including connection complete all as specified and as directed. 84 s&f sheet metal meter box single door minimum size 35x50x25cm for electric meter factory made of ms sheets / crca sheet duly painted with powder paint and door hinged locking arrangement conforming to is 5039 of 1983. the electric meter / switch box shall be suitable for fixing one number of electric meter and knock out holes for incoming and outgoing cable. before the powder paint process the sheet steel shall go through the anti corrosion conditioning process in not less than seven tank process. concealed in wall, including making good distrurbed surfaces with matching colour, complete all as specified and as directed. 85 fixing or hanging only ceiling fans height upto 3mtr to 5 mtrs ceiling height of bldg including three core fr pvc insulated & overall round sheathed flexible with pvc, colour of cores are red, black & yellow / green is for earthing. sheath colour is black of cable size 23 / 0.0076 complete all as specified. ( note : ceiling fans obtained / taking down from item sr no.73 as above ) ...
34773990 tender for provision of mob equipment stores for med regt ( fd regt ) and rewiring of bldg no. p 67 ( 12 qtrs ) or md accn of engr regt at 550 acre under ge ( east ) ferozepur cantt 1 b / r workexcavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, for lying cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft loose soil complete all as specified and as directed. 2 m&l cement concrete in foundations 1:4:8 type d 2, ( 40mm graded stone aggregate as in sub base of foundation, filling and mass concrete complete all as specified and as directed. 3 m&l for brickwork with subclass ‘b’ bricks, straight or curved on plan exc 6m mean radius built in cm ( 1:6 ) complete all as specified and as directed. 4 returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm soft / loose soil complete all as specified and as directed. 5 removing excavated material / soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed. 6 use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or to batter rough finishedsurface of concrete complete all as specified and as directed. 7 use and waste of formwork to sides of pillars, posts, struts, piers, columns etc rough finishedsurface of concreteall as complete all as specified and as directed. 8 use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick ( horizontal or sloping ) rough finishedsurface of concrete complete all as specified and as directed. 9 use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of rcc / pcc bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm widerough finishedsurface of concretecomplete all as specified and as directed. 10 use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finishedsurface of concretecomplete all as specified and as directed. 11 m&l rcc design mix m 25 ( using 20mm graded stone aggregate ) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under reamed piles and mass concrete complete all as specified and as directed. 12 m&l rcc design mix m 25 ( using 20mm graded stone aggregate ) columns, pillars, piers, posts and struts complete all as specified and as directed. 13 m&l rcc design mix m 25 ( using 20mm graded stone aggregate ) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. 14 m&l rcc design mix m 25 ( 20mm graded stone aggregate ) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. 15 m&l mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and as directed. 16 all as per item no 15 above but 5mm dia and over upto and incl 10mm dia in stirupps, spacers and binders etc complete all as specified and as directed. 17 m&l rendering 12mm thickin cement mortar ( 1:4 ) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. 18 m&l rendering 15mm thickin cement mortar ( 1:6 ) on any face of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed. 19 m&lrendering 10 mm thick cement plaster on ceiling surfaces in cement mortar 1:4 finished fair and evenwithout using extra cement complete all as specified and as directed. 20 supply only integral water proofing compound conforming is 2645 1975 of approved make complete all as specified and as directed. 21 m&l preparation of newly plastered surfaces of walls etc, and applying three coats of white wash complete all as specified and as directed. 22 m&l preparation of new plastered surfaces of ceiling & applying two coats of white wash complete all as specified and as directed. 23 m&l applying double coats of bitumen elastometric waterproof coating as on damp proof course / roof including cleaning of surfaces complete all as specified and as directed. 24 m&l 75mm thick cement concrete 1:4:8 type c 2, using 40mm graded brick aggregate as in sub floor, sub base etc, finishing surfaces rough to receive the topping layer all as complete all as specified and as directed. 25 m & l machine pressed precast conctete interlocking paver block any shape and size confirming to is 15658 2006 of 60 mm thickness m 35 grade, jointed and pointed with gray cement and no pigment over sand cushioning complete all as specified and directed. 26 m & l sand filling under floors or in foundations including watering and consolidationcomplete all as directed by engieer in charge . 27 m&l 75mm thick cement concrete ( 1:3:6 ) type c 1 using 20mm graded stone aggregate as in plinth protection, surfaces finished even and fair without using extra cementincluding provision of construction joints complete all as specified and as directed. 28 m&l 75 mm thick cement concrete ( 1:2:4 ) type b 2 using 40mm graded stone aggregate as in floor topping, surface finished even and smooth without using extra cement complete all as specified and as directed. 29 m&l glass dividing strips, 3 mm thick and 38mm width of strip, inserted in position, conform to design complete all as specified and as directed. 30 s&f pressed steel frames ( 1.25mm sheet thickness ) for doors with one or more rebates including necessary fixing lugs , hinges, lock plate, etc., size of frame 105mm x 60 mmincluding one shop coat of red oxide primer complete all as specified and as directed. 31 s&f of 40mm thick flush door shutter of solid core construction with particle board core and plywood face panels, commercial type on both sides one face is covered with decorative face veneerwith lipping / frame to match complete all as specified and as directed. 32 s&f factory made box type steel window with pintal hinges & 2 nos 150 mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on drawing no cejz / td 06 / 07 & cejz / td 07 / 07. 33 s&f factory made box type steel window with pintal hinges & 2 nos 150 mm mild steel tower bolts to each shutter, steel handle and withoutglazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on drawing no cejz / td 06 / 07 & cejz / td 07 / 07. 34 s&f steel ventilators fixed type complete with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and as directed. 35 mild steel framed work of e 165 ( fe 290 ) as in grills / guard bars shouldered with steel window / ventilator frames including red oxide primer coat complete all as specified and as directed. 36 s&f mild steel door handles, stove enameled black, medium wt 125 mm long and fixed with steel screws complete all as specified and as directed. 37 s&f mild steel barrel tower bolts, stove enameled black, with bright bolt, medium weight 150 mm long and fixed with steel screws complete all as specified and as directed. 38 s&f 300 mm long mild steel, sliding door bolt, plate type, stove enameled black, with bright bolt not less than 12 mm dia with and including bolts and nuts complete all as specified and as directed. 39 s&f 3 mm thick, plainsheet glass ordinary quality and glazing, with oil putty or with wooden beads ( supplied alongwith shutters ) , in squares n.exc 0.50 sqm complete all as specified and as directed. 40 s&f stainless steel wire cloth0.56 mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staplescomplete all as specified and as directed. 41 m&l cement concrete ( 1:3:6 ) type c 1 using 20 mm graded stone aggregate as in fillings and mass concrete, filling backs of chowkats etc, complete all as specified and as directed. 42 m&l preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed. 43 m&l preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified and as directed. 44 m&l preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paintcomplete all as specified and as directed. 45 e / m worksm&l for point wiring with 1.5 sqmm ( nominal area ) , pvc insulated, frls multistranded, single core unsheathed, copper conductor cables drawnthrough and including pvc conduit with allaccessories concealled in wall and fixed to ceiling etc. with and including 1.5 sqmm ( nominal area ) pvc insulated, frls unsheathed, multi stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth dolly including sunken boxes of suitable size with 3 mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light / fan / bell point controlled by one , one way switch all as specified and directed. ( a ) one light point / fan point / exhaust point controlled by one single pole one way switch. ( note: wiring shall be done in colour coding ) 46 all as per item no 45 hereinbefore butone 3 pin socket outlet 5 amps independent boardcomplete all as specified and as directed. 47 all as per item no 45 hereinbefore but one 3 pin socket outlet 5amps on the same board with other switches complete all as specified and as directed. 48 all as per item no. 45 here in before but one 15 amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 sqmm pvc insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 sqmm green colours pvc insulated, unsheathed, stranded copper conductor cable. 49 all as per item no. 45 here in before but one 15 amps socket outlet point controlled by one single pole switch one way and wiring with 4.0 sqmm pvc insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 4.0 sqmm green colours pvc insulated, unsheathed, stranded copper conductor cable. 50 s&f switch piano flush type 6 amps, single pole one way, white in colour, duly isi marked complete all as specified and directed. 51 s&f switch piano flush type 20 amps, single pole one way, white in colour, duly isi marked complete all as specified and directed. 52 s&f socket outlet2 in 1, 5 pin, 6 amps, white in colour, duly isi marked complete all as specified and directed. 53 s&f socket outlet, uni, 2 in one10 amps & 20 amps, white in colour, duly isi markedcomplete all as specified and directed. 54 s&f ceiling rose surface type, 240 volts, 50 hz, 6a, pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals dulyisi marked complete all as specified and directed. 55 s&f rotary stepped type electronic fan regulator for ceiling fan 1200 / 1400mm size, 240 volts, 6 amps, 100w, white in colour, duly isi marked complete all as specified. 56 s&f lamp angle holder ( plastic ring ) , 240 volts, 50 hz, 6a, white in colour, duly isi marked complete all as specified and directed. 57 s&f led bulb of 9 watt, b22, 6500k all as specified and directed. 58 s&f 20w, 6500 k, 4 feet led square tube light fitting, energy efficient fixed to wall / ceiling etc complete all as specified and as directed. 59 s&f led sleeky bldg street light ( lens ) fitting of 35 watts, 6000k, including gi bracket bend to shape made out of gi pipe light grade of 25 mm, size up to 1.2 mtr long etc complete with ms clamps made of 25x3mm ms plate, duly painted with two coats of aluminium paint with nuts / bolts / washers and all fixing arrangements to wall / pole, including connecting up with 2 core copper flexible wire of size 23 / 00.0076 complete all as specified and as directed. 60 s&f exhaust fan heavy duty with louvers complete of sweep size 300mm, 900 rpm, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of pvc flexible copper cable of size 23 / 00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and as directed. 61 s&f ceiling fan 1200mm sweep, ac single phase 230 volts 50hz, at bldgs upto 5 mtrs height, including provision of flexible cable 3 core copper conductor of size 23 / 0.0076 of suitable length from ceiling rose to ceiling fan upto 1.5 mtr for giving connection and all hanging arrangement i.e. standard down rod, hanging clamp, with rubber real nuts bolts, spring washers and locking of splite pin, plastic canopy with screw compete without fan regulator and marking of mes nos with black synthetic enameled paint all as specified and as directed. 62 s&f factory made sheet metal enclosures double door type made out of crca 1.2 mm thick m.s. sheet, powder coated, partly embedded in wall, ip 43 protection, vtpn db with 200 amps rated bus bar, 4 way, 415 volts, vertical type, dust and vermin proof, suitable for incorporation of mccbs / mcbs, factory made, including thermal based release adjustable type 4 pole 63 amps, 50 hz, 415 volts with rupturing capacity 16 ka and making good distrubbed surfaces with matching colour, complete all as specified and as directed. 63 s&f factory made sheet metal enclosures double door type made out of crca1.2 mm thick m.s sheet, powder coated, spn db with 200 amps rated bus bar, 8 way, ip 42 protection surface mounting, 240 volts, dust and vermin proof, suitable for incorporation of mcbs duly cocealled in wall, factory made, including making good distrubbed surfaces with matching colour complete all as specified and as directed. 64 s&f mcb spn, 40 amps, 240 volts, b series, 10ka duly isi marked, complete all as specified and as directed. 65 s&f mcb sp, 6a 32 amps, 240 volts, b series, 10ka duly isi marked, complete all as specified and as directed. 66 m&l for sub main wiring with two single core 2x4 sqmm pvc insulated and unsheathed stranded copper conductoralongwith earth wire 4.0 sqmm drawn in including pvc rigid conduit connected to main board complete all as specified and directed ( note: two runs cable and one number earth wire and suitablepvc conduit shall measured together as unit length ) . 67 m&l for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire complete all as specified and as directed. 68 m&l for earthing complete with galvanized steel plate elecrode of size60 cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead gi wire of 4mm dia ( 8 swg ) by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles. the other end of gi earth wire is connected to main switch board and protected by light grade gi pipe of 15 mm bore. provision of 20mm bore light grade gi pipe for watering including gi funnel and wire mesh. pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. cement concrete chamber of pcc ( 1:3:6 ) type c 2 using 40 mm graded stone aggregate.the chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete ( 1:2:4 ) type b 1 using 20 mm graded stone aggregate and ms angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to exposed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in electrical plate no 3 of ssr part 1 ( 2009 ) . 69 supplying, laying, jointing and testing xlpe insulated, armoured, electric cables ( heavy duty ) with aluminium conductor, 1100 volts, grade cross sectional area 25 sqmm 4 core confirming to is:7098 1985 laid in trenches, in floor, in duct, through pipes or along the pole complete all as specified and as directed. ( note: excavation & earth work, cable preotection coverand sand cushion shall be measured &separately ) 70 m&l dry and clean fine sand for cable cushioningto underground cable protection, complete all as specified and as directed. note punned down thickness shall be measured. 71 s&f cover to underground cable with one layer of bricks using sub class ‘b’ bricks ( old size ) laid flat across the cable complete all as specified and as directed. 72 s&f mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles / walls, laid under floor / road crossings, complete with and includingclamps socket & elbow etc complete all as specified and as directed. 73 taking down carefully existig copper / alumn point wiring for light / fan / bell / socket 5 / 15 amp points complete withfitting and fixtures such as switches, sockets, c / rosess, holders and bracket fittings with battens / conduits / wires, t / l fittings and making good the disturbed surfacesof walls and roofs etc.and to match with existing colour complete all as specified and directed. 74 taking down carefully unserviceable main switches and distribution boards with fuses / mcbs ( single phase or three phase ) of any capacity complete all as specified and as directed. 75 taking down carefully old unserviceable sub main wiring including meters and making good disturbed surfaces and matching with existing complete all as directed and specified 76 s&f bell push flush, type 6 amp single pole one way, white in colour, duly isi marked complete all as specified and as directed. 77 s&f door bell ding dong single phase 240 volts, white in colour, duly isi marked complete all as specified and as directed. 78 s&f batten holder ( with metal ring ) , 240 volts, 50 hz, 6a, white in colour, duly isi marked complete all as specified and as directed. 79 s&f factory made three phase and neutral sheet steel made out of crca 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing mcbs and the second for protection of mcbs fitted with colour bus bar of capacity 200 amps, neutral link, earth bar and din rail suitable for use on 240 / 415v, 50hz supply, vtpn db, partly immersed in wall, including of mccb 4 pole adjustable thermal & fixed magnetic type 100 amps, 50hz, 415 volts with rupturing capacity 16 ka and making good distrubbed surfaces with matching colour, complete all as specified and as directed. 80 s&f mcb spn, 40a 63amps, 240 volts, c series, 10ka duly isi marked, in mcb db, complete with connection testing and commissioning complete all as specified and as directed. 81 m&l for sub main wiring with two single core 2x6 sqmm frls insulated and unsheathed stranded copper conductoralongwith earth wire 6.0 sqmm frls drawn in includingrigid conduit connected to main board complete all as specified and directed ( note: two runs cable and one number earth wire and suitableconduit shall measured together as unit length ) . 82 cutting holes making good the distributed surface, grouting nuts for fixing of exhaust fans complete all as specified and directed. 83 m&l for disconnecting electric meter of any cap and refixing same after rewiring, in meter box including connection complete all as specified and as directed. 84 s&f sheet metal meter box single door minimum size 35x50x25cm for electric meter factory made of ms sheets / crca sheet duly painted with powder paint and door hinged locking arrangement conforming to is 5039 of 1983. the electric meter / switch box shall be suitable for fixing one number of electric meter and knock out holes for incoming and outgoing cable. before the powder paint process the sheet steel shall go through the anti corrosion conditioning process in not less than seven tank process. concealed in wall, including making good distrurbed surfaces with matching colour, complete all as specified and as directed. 85 fixing or hanging only ceiling fans height upto 3mtr to 5 mtrs ceiling height of bldg including three core fr pvc insulated & overall round sheathed flexible with pvc, colour of cores are red, black & yellow / green is for earthing. sheath colour is black of cable size 23 / 0.0076 complete all as specified. ( note : ceiling fans obtained / taking down from item sr no.73 as above ) ...
34577123 bids are invited for supply of electrical items pvc insulated copper wire 1 sqmm , pvc insulated copper wire 1.5 sqmm , pvc insulated copper wire 2.5 sqmm , pvc insulated copper wire 4 sqmm , 2.5 x 2 core copper cable , insulation tape 20 mtr length , 6 amp switch piano type , 6 amp socket piano type , 16 amp switch piano type , 16 amp socket piano type , fan regulator , fan capacitor 2.5 uf , pvc pipe 25mm , pvc elbow 25mm , pvc junction 4 way 25mm , pvc anchor clip 25mm , gi clip 25mm , pvc cable clip 4mm , pvc cable clip 5 mm , pvc cable clip 6 mm , pvc cable clip 8 mm , pvc cable clip 10 mm , pvc cable clip 16 mm , flat head switch panel screw 25 mm , flat head switch panel screw 35 mm , flat head switch panel screw 50 mm , cable tie 300 mm , cable tie 250 mm , cable tie 150mm , energy electric meter single phase , 63 amp 4 pole isolator , 100 amp 4 pole isolator , 40 amp dp mcb , pvc round cover sheet , pvc fan round cover sheet , ceiling rose , bakelite sheet size 9x11 , bakelite sheet size 5x8 , bakelite sheet size 4x4 , mcb 16 amp , mcb box 12 way , gi box size 8x10 , gi box size 4x7 , gi box size 4x4 , copper ring type thimble 16 sqmm , copper ring type thimble 25 sqmm , copper ring type thimble 35 sqmm , copper ring type thimble 50 sqmm , copper ring type thimble 70 sqmm , heat shrinkable straight through jointing kit 25 sqmm , heat shrinkable straight through jointing kit 35 sqmm , heat shrinkable straight through jointing kit 50 sqmm , heat shrinkable straight through jointing kit 70 sqmm , heat shrinkable straight through jointing kit 185 sqmm , heat shrinkable straight through jointing kit 240 sqmm , bell switch , batton holder straight , batton holder angle , led tube light 18 watt , led mirror light 5 watt , ceiling fan total quantity : 6405...
34439001 special repair / replacement of distribution board, sub main wiring and other connected items at q zone under ge ( east ) ferozepur cantt taking down carefully unserviceable main switches and distribution boards with fuses / mcbs ( single phase or three phase ) of any capacity complete all as directed and specified. 2 taking down carefully old unserviceable sub main wiring including meters and making good disturbed surfaces and matching with existing complete all as directed and specified. 3 s&f factory made three phase and neutral sheet steel made out of crca 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing mcbs and the second for protection of mcbs fitted with colour bus bar of capacity 200 amps, neutral link, earth bar and din rail suitable for use on 240 / 415v, 50hz supply, vtpn db, partly immersed in wall, including of mccb 4 pole adjustable thermal & fixed magnetic type 100 amps, 50hz, 415 volts with rupturing capacity 16 ka and making good distrubbed surfaces with matching colour, complete all as specified. 4 s&f factory made single phase and neutral sheet steel made out of crca 1.2 mm thick, powder coated double door vertical distribution board 8 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing mcbs and the second for protection of mcbs fitted with colour bus bar of capacity 200 amps, neutral link, earth bar and din rail. suitable for use on 240v, 50hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as directed and specified. 5 s&f mcb spn, 40a 63amps, 240 volts, c series, 10ka duly isi marked, in mcb db, complete with connection testing and commissioning complete all as directed and specified. 6 s&f mcb sp, 6a 32 amps, 240 volts, b series, 10ka duly isi marked, in the mcb db, complete with connection testing and commissioning complete all as directed and specified. 7 m&l for sub main wiring with two single core 2x6 sqmm frls insulated and unsheathed stranded copper conductoralongwith earth wire 6.0 sqmm frls drawn in and including rigid conduit connected to main board complete all as specified and directed ( note: two runs cable and one number earth wire and suitable conduit shall measured together as unit length ) . 8 m&l for disconnecting electric meter of any cap and refixing same after rewiring, in meter box including connection frls complete all as directed and specified. 9 m&l forearth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire complete all as directed and specified. 10 s&f xlpe insulated, armoured, 1100 volts grade, heavy duty cable of size 25 sqmm nominal cross section, 4 core, aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over all pvc sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing with double compression copper stain less steel gland at dbs and testing, complete all as directed and specified. ( note: excavation & earth work, brick protection and sand cushionshall bemeasured and paid separately ) 11 s&f xlpe insulated, armoured, 1100 volts grade, heavy duty cable of size 10 sqmm nominal cross section, 2 core, circular, pvc insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over all pvc sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing and testing, complete all as directed and specified. ( note: excavation & earth work, brick protection and sand cushionshall bemeasured and paid separately ) 12 s & f in repairs, installation, commissioning and testing polycarbonate asta cpri approved oem made meter enclosure. the meter box shall be made of modular polycarbonate thermoplastic enclosures which should be uv resistance in accordance with iec 61439 1, clause 10.2.4: the meter box with the provision for 6 nos single phase meters with provided bakelite sheet at the bottom of meters ( size 600 x 600 x 170mm ) . meter box type wall mounted type on mounting structure ral 7016, anti acid, anti corrosive & fully transparent door for meter vision with four side screw drive operated locking . degree of protection ip 65 in accordance with iec 60529 and against mechanical load should be ik08 ( 5 joule ) in accordance with iec 62262. the meter enclosure as per aproved make in mes command list. the manufacturer of panel shall submit a copy of his asta cpri test report in polycarbonate only also share panel assemble by oem, channel partner or sister concerned assembly will not accepted and submit the copy of asta cpri report shall have mention of following tests performed and passed out satisfactorily temperature rise, dielectric properties, short circuit withstand current – rated peak, short time withstand current and rated conditional short circuit current, effectiveness of protective circuits and submit the copy of type test reports for polycarbonate thermoplastic board only.test reports submitted of other material of construction like ms, ss will not be applicable. the meter box should passed glow wire test 960oc in accordance with 60695 2 11 [ flame retardant and self extinguishing ] . the gasket should be internally embedded made of polyurethane . meter enclosures provided with wall mounting povision & enclosures accessoriesas per ral 7035. make hensel / rittal / emitter / schneider / abb. 13 m&l for earthing complete with galvanized steel plate elecrode of size 60cm x 60cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead gi wire of 4mm dia ( 8 swg ) by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles. the other end of gi earth wire is connected to main switch board and protected by light grade gi pipe of 15 mm bore. provision of 20mm bore light grade gi pipe for watering including gi funnel and wire mesh. pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. cement concrete chamber of pcc ( 1:3:6 ) type c 2 using 40 mm graded stone aggregate.the chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete ( 1:2:4 ) type b 1 using 20 mm graded stone aggregate and ms angle iron 50 x 50 x 6mm frame including two coats of painting over a red oxide to exposed steel surfaces. excavation in soft / loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in electrical plate no 3 of ssr part 1 ( 2009 ) complete all as directed and specified. 14 excavation in trenches in soft / loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and not exc 10 sqm on plan, for laying of cable and getting out, complete all as directed and specified. 15 m&l dry and clean fine sand for cable cushioningto underground cable protection, complete all as directed and specified. note punned down thickness shall be measured. 16 s&f cover to underground cable with one layer of bricks using sub class ‘b’ bricks ( old size ) laid flat across the cable complete all as directed and specified. 17 returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer, complete all as directed and specified. 18 removal of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point complete all as directed and specified. 19 s&f mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles / walls, laid under floor / road crossings, complete with and including clamps socket & elbow etc including taking down, complete all as directed and specified. 20 supply and installation in repairs, commissioning and testing polycarbonate asta cpri approved oem made outdoor main lt panel with canopy ( mini. size 600 x 600 x 170 mm ) . the panel shall be made of modular polycarbonate thermoplastic enclosures including mccbs and indicator lamps which shall be uv resistance in accordance with iec 61439 1, clause 10.2.4: the panel shall be anti acid & anti corrosive. degree of protection against mechanical load shall be ik08 ( 5 joule ) in accordance with iec 62262. the manufacturer of panel shall submit a copy of asta cpri test report in polycarbonate only also share panel assembled by oem, channel partner or sister concern assembly will not be accepted. degree of ingress protection ip 65 in accordance with iec 60529. the gasket shall be internally embedded made of polyurethane. the panels made by aprroved enclosures in mes & they shall submit a copy of type test report of a board made out of polycarbonate thermoplastic panel in accordance with iec 60439 1. the cpri report shall have mention of following tests performed and passed out satisfactorily temperature rise, dielectric properties, short circuit withstand current – rated peak & short time withstand current and rated conditional short circuit current, effectiveness of protective circuits. the board manufacturer shall submit the copy of type test reports for polycarbonate thermoplastic board only. test reports submitted of other material of construction like ms, ss will not be applicable. each board shall have individual routine test report of the manufacturer. the panel shall pass glow wire test 960 degrees centigrade in accordance with 60695 2 11 [ flame retardant and self extinguishing ] . ms angle stand 450 height from gound.make hensel / rittal / emitter / schneider.incomer ( a ) mccb 100a fp 25ka thermal & magnetic released with earth fault protection with spreader links 01 nos. ( b ) led indicator r, y, b 01 set ( c ) copper bus tpn 150 amp 01 setoutgoing ( a ) mcb 63a spn 10ka 240v c curve 07 nos...
34295465 bids are invited for equipment for electrical shop multimeter , pliers , screw driver set , wire gauges , test pin , wires 0.75mm , wire 1mm , wire 1.5 mm , wire 2.5mm , wire 4 mm , resistances , fuse , switches one way , inductor , capacitor , sockets 6 amp , sockets 15amp , ceiling rose , electric kettle , hydrometer , cell tester , transformer single phase , transformer three phase , diodes , transistor , a.c ammeter , d.c ammeter, , a.c voltmeter, , d.c voltmeter , energy meter , wattmeter, , pmmc ammeter and , pmmc voltmeter , logic gates kit , batten , pvc pipe , batten gutti , pvc clamp for pvc pipe , switches two way , auto electric iron , electric meter , digital electric meter , nose plier , starting of induction motor by auto transformer , starting induction motor by d o l starter , automatic wire , board of safety instructions , ratchet wire crimping tool kit with 5 interchangeable jaws, wire striper and cutter for insulated and non insulated , chalk line marker , chisel , combination pleirs , connector screw driver set , double end spanner , flat screw driver medium , flat screwdriver small , grip plier , half round file , hand crimping tools ,hss twisted drill bit , line tester , magnetic spirit level ,measuring tape , meeger , monkey plier , pipe wrench ,reflecting life jacket , rubber hand gloves , safety belt , safetyhalmet , star screw driver medium , star screw driver small ,straight cutter , tool box , power factor meter , two wattmetermethod , thermister , speed control of dc shunt motor , studyof dc series motor with starter , swinburne test panel , opencircuit and short circuit test panel for transformer , three phasetransformer under balanced loadwinding panel for star tostar,star to delta, delta to star, delta to delta configuringconditions. , ohm law kit , lenz law kit , krichoff law kit ,filament lamp , battery charger , load test on single phasetransformer. , load test on dc generator , characteristics of dcshunt motor , starting induction motor by dol starter total quantity : 673...
32999129 ge(s)/m 03/2022 23 repair/replacement and winding of ceiling fan, electric meter, exhaust fan etc in md/otm accn of d i, d ii zone and ajay garrison under age em of ge (south) mamun...
31558429 8936 nit 83 21 22 maint / repair of ceiling fan, exhaust fan, electric meter and other fans under ge north bathinda at bathinda mil stn maint / repair of ceiling fan, exhaust fan, electric meter and other fans under ge north bathinda at bathinda mil stn...
31084750 job work order replacement of 44 nos electric meters in kk vihar...
31014762 spl repair replacement of ber electric meter with temper proof electronic meter connected allied wks and provn of certain minor works of em under ge east ferozepur cantt spl repair replacement of ber electric meter with temper proof electronic meter connected allied wks and provn of certain minor works of em under ge east ferozepur cantt...
30352027 addition / alteration and provn of basic amenties to certain smqs / omqs, ac for briefing hall, deficient electric meters at various locations and dg set at air force station pathankot addition / alteration and provn of basic amenties to certain smqs / omqs, ac for briefing hall, deficient electric meters at various locations and dg set at air force station pathankot...
30146377 job work order replacement of 44 nos electric meter...
29847522 job work order replacement of electric meters...
29643724 cwe / pat / t 59 / 2021 22 provn of pre paid meter in orrs messes institue and offrs accn at patiala mil stn under ge north patiala provn of pre paid electric meter in offrs messes institute offrs md accn at mil stn patiala under ge north patiala...
29602221 sale of condemned scraps items 1 old books 2 iron scraps 3 brass scraps 4 steel scraps 5 wooden scraps 6 plastic scraps 7 scraps papers 8 note books 9 text books 10 peg table 11 desert coolers with angle 12 table wooden 13 chair wooden 14 curtain rod with material 15 exhaust fan 12 16 ceiling fans 48 17 curtain cotton/cloth 18 aqua guard high flow 19 digital dvd player 20 electric meter single 21 automated vending machine for sanitary napkin 22 battery for power supply 23 bed single 24 pad lock 25 impex laminator 26 lawn mover complete 27 epabx telephone exhange 28 fadt 1/15h0 watt 29 dustbin big 30 cable 95mm 4 core 31 bed sheet 32 carpet door mat pvc 33 pressure cooker 22 ltrs 34 carpet 35 durrie 18 x 15 36 neel kamal chair plastic 37 teacher table 30 x 48 laminated board 38 student steel chairs 6x16 39 desk for students 40 paxioscope 41 computer chair revolving, printer 3r tvse classic, ups batteries 600va, badminton net, foot ball/volley ball, three desk oven lpg ...
24213099 repair to fan , electric meters and day to day complaints of internal electrification under ge gurdaspur . ...
23750952 repair to fan , electric meters and day to day complaints of internal electrification under ge gurdaspur . ...
23740818 special repair to roof treatment , sunken floor , plumbing , sanitary fittings , plastering including rewiring / replacement of old electric meter , water fitting , tiling , joinery of bldg no p 98 ( 01 to 08 qtrs ) under ge ( north ) mamun at mamun mil station...
23278733 providing of 3 phase electric meter providing of 3 phase electric connection for installation of explosive meltout unit ( emu ) in ammunition technical area at 33 fad dappar...
21790130 tender for accuring building on lease please : approximately carpet area 402 sq. ft. including app. 60 sq. ft. for place of vehicles / parking. the building should have independent electric meter and basic amenities like drinking water, toilet and bathroom. the land lord should be ready to make addition, alternation and to provide counters...
19917952 repair to fan, electric meters and day to day complaints of internal electrification under ge gurdaspur.=> open tender...
19895278 special repair of solar water heating system and provision of earthing lightening conductor electric meter and geysers under ge north at bathinda mil stn, spl repair of solar water heating system and provn of earthing lightening conductor electric meter and geysers under ge north at bathinda mil stn=> open tender...
19688438 special repair of solar water heating system and provision of earthing lightening conductor electric meter and geysers under ge north at bathinda mil stn, spl repair of solar water heating system and provn of earthing lightening conductor electric meter and geysers under ge north at bathinda mil stn=> open tender...
19688305 repair to fan, electric meters and day to day complaints of internal electrification under ge gurdaspur.=> open tender...
16295471 repair to fan, electric meters and day to day complaint of internal electrification under ge gurdaspur...
15579984 auction sale of lot no: 4 lot name: electric meter old unsv etc...
15141796 comprehensive maintenance of ceiling fans, exhaust fans electric meters and attending day to day complaints of internal electrification of certain area at tibri mil stn....
14450569 construction of toilet bathroom store room guard room provision of ceiling fan electric meter and certain other sanctioned works under age br v and age em v office of ge north bathinda mil stn...
14169301 construction of toilet bathroom store room guard room provision of ceiling fan electric meter and certain other sanctioned works under age br v and age em v office of ge north bathinda mil stn...
13444254 special repair replacement ber ceiling fans, exhaust fans, electric meters and geysers at tibri military station under ge gurdaspur...
12863584 repair maintenance of internal electrification fitting and fixtures distribution boards electric meters and submain for zone a area at dalhousie cantt...
12848104 repair maintenance of internal electrification fitting and fixtures distribution boards electric meters and sub main for zone b at dalhousie...
11813317 providing of automatic timer switch for street light near vivekanand circle,electric meter at shaurya school 04 led flood lights 120watt and 04 led 72 watt at triveni vihar and other sanctioned works under ge w pathankot, ge/pkt/t 48/2016 17...
11648329 provision of automatic timer switch for street light near vivekanand circle electric meter at shaurya school 04 led flood lights 120 watt and 04 led 72 w at triveni vihar and certain other sanctioned works under ge west pathankot, ge / pkt / t 48 / 2016 17...
11284240 special repairs for replacement of electric meter into tamper proof electronic energy meter at sangrur under ge south patiala,...
10552208 repair / replacement of internal electrification, fitting and fixtures, distribution boards, electric meters and submains at dalhousie cantt,...
10470672 provision of 06x 500 ltr solar water heaters for bathroom of otm accommodation at 550 acre of 17 assam ( now 12 assam ) and provision of special repair for replacement of ber electric meter with temper proof electronic meter and connected allied wks at ge ( west )...
10335839 provision of 06x 500 ltr solar water heaters for bathroom of otm accommodation at 550 acre of 17 assam ( now 12 assam ) and provision of special repair for replacement of ber electric meter with temper proof electronic meter and connected allied wks at ge ( west ) area an,...
9982003 provision of 06 solar water heaters of otm accommodation at 550 acre provision of special repair for replacement of ber electric meter with temper proof at ge ( west ) area and provision of 03 solar water heater for or lines at 507 asc under ge east ferozepur cantt,...
9928515 provision of special repair for replacement of ber electric meter with temper proof electronic meter and connected allied wks under ge east ferozepur cantt,...
9805809 provision of security lights, electric meters and dg sets under age e / m i of ge mamun at military station mamun...
9563115 provision of special repair for replacement of ber electric meter with temper proof electronic meter and connected allied wks under ge east ferozepur cantt,...
9374748 provision of special repair for replacement of ber electric meter with temper proof electronic meter and connected allied wks under ge east ferozepur cantt, provn of...
9196293 provision of special repair for replacement of ber electric meter with temper proof electronic meter and connected allied works under ge east ferozpur cantt...
7836856 as described in bill of quantities, special repairs to bldg no p 129/1 to p 129/4 of officers md accn, special repair to bldg no p 8 at mes colony and special repair/ replacement of ms boxes of defective electric meters at military station kapurthala under ge kapurthala...