Military Engineer Services - Punjab

37274515 repair and replacement of plastering, flooring, joinery, connected b / r items and periodical services to otm accn in new cantt zone ‘a’ at mil stn patiala under ge ( south ) patiala. 1 taking down chowkhats or frames (wooden joineries with wooden or steel chowkats) complete with shutters (without taking off shutters from the frames) exc 1.5 sqm butnot exc 4.00 sqm each and removing from site or to store as complete all as specified and directed by engineer in charge. 2 taking down chowkhats or frames(wooden joineries with wooden or steel chowkats) complete with shutters (without taking off shutters from the frames) notexc 1.5 sqm each and removing from site or to storecomplete all as specified and directed by engineer in charge. 3 taking down wooden shutters of any description exc 1.00 sqm but not exc 2.00 sqm each and removing from site or to storecomplete all as specified and directed by engineer in charge. 4 s &f pressed steel framed made out of 1.25mm thick ms sheet, of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc,complete all as specified and directed by engineer in charge. 5 description all as per serial item no 4 here in before but size 105 x 60mmcomplete all as specified and directed by engineer in charge. 6 m&l for cement concrete 1:2:4 type b 0 using 12.5 mm graded crushed stone aggregate as in mass concrete or filling backs of chowkats complete all as specified andcomplete all as specified and directed by engineer in charge. 7 s&f factory made flush shutters 35mm thick minimum 5 ply, solid core construction, with block board core and plywood face panels, commercial type on both sides with 6mm thick lipping frame to match including supply and fixing following itemscomplete all as specified and directed by engineer in charge:(a) stainless steel (304 grade) finished butt hinges 100mm 4 nos per leaf(b) stainless steel (304 grade) finished tower bolt 150mm long 2 nos per leaf(c) stainless steel (304 grade) finished handles 150 mm 2 nos per leaf(d) stainless steel (304 grade) finished sliding door bolt/aldrop 16 x 300mm 1 no per leaf(e) stainless steel (304 grade) finished floor door stooper 1 no per leaf 8 s&f 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in ssr 91 pt 1 section 8 clause 8.20(a), kiln seasoned and chemically pressure treated all as specified including stainless steel 304 grade wire cloth (wire dia. 0.36mm) and supply and fixing the following itemscomplete all as specified and directed by engineer in charge.:(a) stainless steel (304 grade) finished butt hinges 100mm 3 nos per leaf(b) stainless steel (304 grade) finished tower bolt 150mm long 2 nos per leaf(c) stainless steel (304 grade) finished handles 150 mm 2 nos per leaf(d) stainless steel (304 grade) finished sliding door bolt/aldrop 16x300mm 1 no per leaf 9 providing and fixing factory made extruded aluminium casement windows (with provision for cooler) with 50 micron powder coating doubled panelled anddouble shutters consisting of frame and mullion of 101.60x44.45x1.29 mm and shutters made of 63.5x31.75x1.29mm and to be fixed with and including epdm gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size with and including 5mm thick glass in front shutters and stainless steel wire gauge 0.36mm dia and 1.40 aperature in inner shutters complete fixed incomplete all as specified and directed by engineer in charge including supply and fixing following items : (a) stainless steel (304 grade) finished butt hinges 100mm 2 nos per leaf.(b) powder coated aluminium tower bolt 150mm long 2 nos per leaf.(c) powder coated aluminium handles 150 mm 1 nos per leaf. 10 s & f anodised aluminium window and ventilator shutters fixed type without sash bar,powder coating of any colour ( thickness of powder not less than 50 microns). aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc.complete all as specified and directed by engineer in charge. 11 powder coated 50 microns extruded aluminium glazing doors & shutters made out of section 63.5x38.10x1.29mm for chowkats or frame & shutters made of size 44.45x44.45x1.29mm for side rails and middle rail, 114.3x44.45x1.29mm for top rails and bottom rails and including 12mm thick high density fibre board pre laminated on both sides (water proof) below & above middle/lock rail and to be fixed with and including epdm gasket to render the glazing, air and water tight etc. and aluminium beads 20mm sizecomplete all as specified and directed by engineer in charge.including supply and fixing the following items:(a) stainless steel (304 grade) finished butt hinges 100mm 3 nos per leaf.(b) powder coated aluminium tower bolt 150mm long 2 nos per leaf(c) powder coated aluminium handles 150 mm 2 nos per leaf 12 s & f in repair aluminium tower bolt 200mm longaddand fixedcomplete all as specified and directed by engineer in charge. 13 s & f in repair aluminium alloy, anodised, sliding door bolt 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed by engineer in charge. 14 s & f in repair mild steel butt hinges of size 100mm medium weight cold rolledcomplete all as specified and directed by engineer in charge. 15 s & f in repair floor door stopper 150 mm long of aluminium alloy body and toungue anodised with hard drawn steel springfixedin floorscomplete all as specified and directed by engineer in charge. 16 s & f in repairaluminium handles of size 150mm ovaltypecasttype anodisedcomplete all as specified and directed by engineer in charge. 17 framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conformint to fe 410 w complete all as specified and directed by engineer in charge. 18 s & f factory made solid panel pvc door shutters 30 mm thick (style) consisting of frame made out of m.s. tubes for top & bottom rails. m.s. frame shall be covered with heat moulded plain colour pvc ‘c’ channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour pvc sheet to be fitted in the m.s. frame welded / sealed to the stiles & rails with suitable pvc sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing s& f complete all as specified and directed by engineer in charge. 19 s & f solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with m.s. square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by engineer in charge. 20 s & f 100 mm size pvc butt hingescomplete all as specified and directed by engineer in charge. 21 s & f 125 mm pvc handlescomplete all as specified and directed by engineer in charge. 22 s & f200 mm long pvc tower boltcomplete all as specified and directed by engineer in charge. 23 m & l for preparing new or previously untreated surfaces of wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primercomplete all as specified and directed by engineer in charge. 24 m & l for preparing new or previously untreated surfaces of steel or iron work of any description and girth over 10cmand applying two coats of synthetic enamel paintcomplete all as specified and directed by engineer in charge. 25 factory made steel window box type using erw hollow p section comprising double frame for and including gauged and glazed skeleton shutter jointed internally with flat iron 40x4mm complete including grill of 8mm square bars, fixed horizontally @ 10cm c/c, hinges, handle, tower bolts, stops, lugs etc. all as shown on drawing no. td 219(c) sheet 1/3 to 3/3complete all as specified and directed by engineer in charge and as approved by genote: (i) for the purpose of measurement & payment double shutter with frame shall be considered as one unit. (ii) unit rate quoted against this item shall also include the iron mongery and grill as shown on drgs.(iii) glazing, wire mesh & painting shall be measured & paid for separately. 26 taking down old unserviceable wire cloth any size from wooden/ metal framescomplete all as specified and directed by engineer in charge. 27 s & f galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples incl replacement of second class wooden beading where ever reqdcomplete all as specified and directed by engineer in charge. 28 hacking out old broken glass (any thickness , size , quality or description) from wooden or metal frames glazed with oil putty or fixed with beads complete all as specified and directed by engineer in charge. 29 s & f sheet glass ordinary quality 4 mm thick not exe.0.50 sqm glazing with oil putty or fixed with wooden beads in squares any size of panecomplete all as specified and directed by engineer in charge. 30 description all as per serial item no 38 here in before but 4mm thick frosted glasscomplete all as specified and directed by engineer in charge. 31 s&f mild steel rat tail rod pattern helical door spring of size 300mm including roller and roller plate fixing to iron frame by weldingcomplete all as specified and directed by engineer in charge. 32 demolition of cement concrete un reinforced in ground floors and pavingsnexec 150 cm thick (above or below ground level) complete all as specified and directed by engineer in charge. 33 demolition of re inforced cement concrete of any description and in any position incl cutting of re inforcement to facilitate demolition where everreqd complete all as specified and directed by engineer in charge. 34 m & l for machine cut mirror polished kota stone 20mm 25mm thick slab as in cooking platforms/ landings, treads and risers of stairs and stepslaid over and includingscreed bed or 15mm th bedding layer in cement mortar 1:3 as base laid and jointed with grey cement slurry mixed with pigment to match the shade including rubbing, polishingcomplete all as specified and directed by engineer in charge. 35 m & l for machine cut mirror polished kota stone slab flooring 20mm 25mmthick laid over and including 20mmscreed bedor bedding layer in cement mortar 1:4 as base laid and jointed with grey cement slurry mixed with pigment to match the shade including rubbing, polishingcomplete all as specified and directed by engineer in charge. 36 rounding to edges of stone slabs one edge , such as in steps, cooking plateforms & other similar situationscomplete all as specified and directed by engineer in charge. 37 dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by engineer in charge. 38 m & l for glazed ceramic coloured tiles in verticle surfaces joint free with glazed economy finish grade b ii (b) of size 300 x 600mm or bigger size7 mm thickas approved set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over 10 mm thick rendering in cement mortar in cm 1:3 for dado etc.,complete all as specified and directed by engineer in charge.note for skirting onlyskirtingmay be providedfrom the same tiles as being used in the floor of sameroomto match in lieu of economy finish tiles but nothing extra shall be admissible on this account. 39 m & l for non skid ceramic joint free tiles {non skidfinish/ matt superior finish grade b i or b ii (b) as approved}7 to 8 mm thick with rectified edges, (square/rectangular) area of each tile exceeding 0.11sqm and not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 15 mm thick cement screedbed in cm 1:4complete all as specified and directed by engr in charge 40 m & l for vitrified ceramic tiles 8 9mm thick light colour (square/ rectangular) polished, area of each tile 600 x 600 mm , in floors etc. set and jointedin neat cement slurry and pointed in white or coloured cement to match the shade of tileover 15mm thick screed/ bedding layerin cm 1:4complete all as specified and directed by engineer in charge. 41 m & l for pcc 1:2:4 type b1 (using 12.5mm graded stone aggregate)25 mm thick to receive the floortiles complete all as specified and directed by engineer in charge. 42 taking down cementplaster or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed by engineer in charge. 43 m & l for rendering 15mm thick cement plaster in cement mortar 1:4 using wpcon fair faces of brick or concrete surfaces on walls etc., finishedeven and fairwithout using extra cement, complete all as specified and directed.note: supply only wpc shall be measured separately & paid for accordingly & shall beprovided @ 3% by weight of cement or as per manufacturers instructionscomplete all as specified and directed by engineer in charge. 44 supply only liquid waterproofing compound complete all as specified and directed by engineer in charge. 45 m & l for rendering 10 mm thick cement plaster in cement mortar 1:6 on fair faces of brick or concrete surfaces on walls etc., finishedeven and smooth without using extra cement,complete all as specified and directed by engineer in charge. 46 dubbing out average 15 mm thick in cement mortar 1:4 on irregular faces of walls, ceiling & chhajjas incl removing carefully old damaged loose concrete from rcc / pcc surfaces of ceiling/ chhajjas for double storey bldgscomplete all as specified and directed by engineer in charge. 47 m & l for rendering 10mm thick cement plasterin cm 1:3on concrete surfaces in ceiling/ chhajjas finished even and smooth without using extra cement complete all as specified and directed by engineer in charge. 48 preparation of new plastered or unplastered surfaces of walls etc.,and m & l for applying twocoat of distemper oil emulsion (obd) over a coat of chalk whiting (as primer)complete all as specified and directed by engineer in charge. 49 m & l for preparation of new plastered or unplastered surfaces of ceiling etc.,and applying three coat of lime white wash on ceiling surfacescomplete all as specified and directed by engineer in charge. 50 preparation of new plastered or unplastered surfaces of walls etc.,and m & l for applying twocoat of cement base paintover a coat of alkli resistance priming paint (as primer)complete all as specified and directed by engineer in charge. 51 m & l for pcc 1:2:4 type b1 (using 12.5mm graded stone aggregate) as in roof kerbs, pcc khurras, coping on parapet wall, mud stops, steps small sumps and like items slightly rounded or chamfered on the edgescomplete all as specified and directed by engineer in charge. 52 racking out joints , hacking for key incl removal of all grass, vegetation growth from roofs etc., andm & l for flush pointing to roof tiles/ terracing incement mortar 1:3complete all as specified and directed by engineer in charge. 53 demolition of brick work including all quains and arches pillars etc built in cement mortar or cement lime mortarcomplete all as specified and directed by engineer in charge. 54 m&l for brick work in cement mortar (1:6) using sub class b old size bricks staight or curved on plan exc 6.0 m mean raiduscomplete all as specified and directed by engineer in charge. 55 m & l 50mm thick pcc (1:3:6) type c2 (using 40mm grade aggregate) as in plinth protection, finishing the surfaces even & smooth w/o using extra cement complete all as specified and directed by engineer in charge. 56 s & f precast concrete interlocking paver block any shape and size & incl 25mm thick layer of sand cushion complete all as specified and as directed. confirming to is 15658 2006 of 60 mm thickness, m 35 gradecomplete all as specified and directed by engineer in charge. 57 dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by engineer in charge. 58 dismantling timber scantlings in framed work 40 sq. cm and over in section, in any position complete all as specified and directed by engineer in charge. 59 anodised aluminium snap grid frame work for false ceiling all as specified (size of grid 605 x 605mm) incl hangers 6 mm dia. g.i. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of g.i. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm longcomplete all as specified and directed by engineer in charge. 60 material & labourforgypsum board 600mmx 600mm x 12mm thick in ceiling fixedas per manufacturers instructions all as specified andcomplete all as specified and directed by engineer in charge. 61 s & f for hollowpvc wall liningconsisting of5mm thick wood grain printed pvc sheet inclusive of solvent cement and fixing at site on pvc frame as per specifications and drawing complete all as specified and directed by engineer in charge. 62 m & l for 5mm thick pvc sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make pvc frame as per specification and drawing complete all as specified and directed by engineer in charge. 63 s &f in repairpvc (swr) pipe110 mm bore rain water pipe single socketed in any length with rubber ring joints,fixed to wall complete all as specified and directed by engineer in charge. 64 complete removal of existing treatment of any type/description such as cement base paint, external emulsion etc from external surfaces of walls/rcc surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc with mechanical means/grindercomplete all as specified and directed by engineer in charge. 65 applying acrylic wall care putty in external walls/rcc surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior paintingcomplete all as specified and directed by engineer in charge.notes : (i) the prepared surface after wall putty, the contractor will inform to the ge as well as to the engineer in charge for site inspection before applying further external finishes. please note that the further external finishes work will start only after approval of the prepared surface from the ge as well as to the engineer in charge through site order. 66 applying 02 coats of exterior emulsion paint (light shade) as per manufacture instructions by using roller to external walls/rcc surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed by engineer in charge. 67 writing letter of figures (block, roman italic or indian) n exc 30cm high complete all and the colour of paint and dimension of letter to be used as approved by engr in charge. 68 writing stops , commas, short lines, dashes, hypens, brackets etc and the colour of paint and dimension of letter to be used as approved by engr in charge. 69 m&l for cement plastering 5mm thick in(small patches) cemet mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by engineer in charge. 70 complete removal of existing treatment of any type/description such as distempering work, internal emulsion etc from internal surfaces of walls & ceiling with mechanical means/grindercomplete all as specified and directed by engineer in charge. 71 applying acrylic thick wall care putty on internal surfaces of walls/ceilings (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving interior paintingcomplete all as specified and directed by engineer in charge.notes : (i) the prepared surface after wall putty, the contractor will inform to the ge as well as to the engineer in charge for site inspection before applying further external finishes. please note that the further external finishes work will start only after approval of the prepared surface from the ge as well as to the engineer in charge through site order. 72 applying 02 coats of interior emulsion paint (light shade) as per manufacture instruction by using roller to wall surfaces over & including a coat of interior wall primer as recommanded for under coat by manufacturer of interior emulsion by using following brands of emulsion and primercomplete all as specified and directed by engineer in charge. 73 m&l for preparing existing old treated surface of external walls/rcc surfaces/soffits of chajjas/roof projection/centilevers/balcony etc incl cornices and applying one coat of cement base paint @5sqm/kg/1 coat by usingof cement based paint by rollercomplete all as specified and directed by engineer in charge. 74 m&l for preparing existing old treated surface of external walls/rcc surfaces/soffits of chajjas/roof projection/centilevers/balcony etc incl cornices and applying two coat of cement base paint @5sqm/kg/1 coat by usingof cement based paint by rollercomplete all as specified and directed by engineer in charge. 75 m& l for prepration of old plastered surface/unplastered surfaces including washing, rubbing down and stoping of distempered and painted surfaces and applying two coat of oil bund distemper on wallcomplete all as specified and directed by engineer in charge. 76 m& l for prepration of old plastered surface/unplastered surfaces including washing, rubbing down and stoping of distempered and painted surfaces and applying one coat of oil bound distemper on wallcomplete all as specified and directed by engineer in charge. 77 m & l for preparing existing treated surfaces on wall including cornices and applying one coat of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. this shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. about 1.3 kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub resistant. small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by engineer in charge. 78 m & l for preparing existing treated surfaces on wall including cornices and applying two coat of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. this shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. about 1.3 kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub resistant. small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by engineer in charge. 79 m & l for preparing existing treated surfaces on ceiling including cornices and applying one coat of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. this shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. about 1.3 kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub resistant. small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by engineer in charge. 80 m & l for preparing existing treated surfaces on ceiling including cornices and applying two coat of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream. this shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth. 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream. about 1.3 kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub resistant. small quantity of ultramarine blue (upto 3 gm per kg of lime) shall also be added to the of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by engineer in charge. 81 m & l for preparing old painted steel and iron surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by engr in charge. 82 m & l for preparing old painted wood & wood based surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by engr in charge. ...

Ministry Of Defence - Punjab

36687407 bids are invited for electrician tool kit (q3) , forming embankments including raising or lowering using sieved clean sand not exceeding 1.5 metre high from base , exceeding 1.5 metre but not exceeding 3 metre high from base , exceeding 3 metre but not exceeding 4.5 metre high from base , exceeding 4.5 metre but not exceeding 6.0 metre high from base , making mixture of local sand and saw dust in equal proportions and filling the same in jute bags , ditto but 3 to 4.50 mtr high , ditto but 4.50 to 9.00 mtr high , dismantling of brickwork or stone boulder masonry built in cement mortar including all quoins , m and l for brickwork using retrieved subclass b old size bricks straight or curved on plan exc 6m mean radius , m and l brick work with sub class b bricks straight or curved on plain exc 6m , taking down cement plaster of any description on brick concrete or stone walls etc , m and l rendering 15mm thick on brick work or concrete surface in cement mortar 1.4 finished , m and l two coats of exterior acrylic emulsion paint over a coat of exterior water based primer total quantity : 1580...

Indian Army - Punjab

36661794 bids are invited for brown drawing sheet , colin bottle , lime , air freshner , gum bottle , plastic emulsion paint , fire extinguisher dry powder , geru powder , printed register , napthelene ball , coconut broom with strips , paint red colour asian , paint black colour asian , paint yellow colour , paint white colour asian , paint green colour asian , paint silver colour , paint golden colour , dispanser water bottle , 5 pin extension board , red colour folder , calender frame , harpic mse total quantity : 2082...

Ministry Of Defence - Punjab

36628543 bids are invited for applying two coats of synthetic enamel paint , excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m depth , returning filling in including spreading levelling watering and well ramming in layers n exc 25 cm. , removing excavated material soils n.exc 250 mtr and n exc 500 mtr , m and l for cement concrete type d2 1.4.8 40 mm graded aggregate , m and l for reinforced cement concrete niminal mix type b1 1.2.4 20 mm graded aggregate , m and l mild steel tmt bars 10 mm dia and over cut to length bent to shape required including cranking , m and l mild steel tmt bars 5 mm dia and over upto and including 10 mm dia in cut to length bent to shape , mand l formwork to sides of concrete foundations footings bases of columns raft and raft beams , m and l rendering 15 mm thick cement plaster 1.4 on fair faces of brick work or concrete surfaces , m and l two coat of exterior emulsion paint apex over a coat of primer , surface excavation n exc not exceeding 30 cm deep and 15 cm deep , hardcore of gauge n exc. 63 mm deposited spread and levelled , m and l for cement concrete 75 mm thick 1.3.6 type c2 using 40 mm graded stone aggregates. , demolition of un reinforced cement concrete in ground floor and paving not exceeding 15 cm thick , m and l for cement concrete 1.2.4 type b 1 using 20mm graded aggregate , m and l for 100 mm thick pcc 1.4.8 type d 2 using 40mm graded stone aggregate , m and l factory made machine pressed precast concrete interlocking paver block any shape and size , clay bricks is:1077 ( q3 ) total quantity : 32416...

Ministry Of Defence - Punjab

36123355 bids are invited for taking down cement plaster of any description on brick walls or concrete surfaces etc , rendering 15 mm thick in cement mortar 1.4 on brick or concrete surfaces of walls finished , rendering 15 mm thick in cement mortar 1.6 on brick or concrete surfaces of walls finished , preparation and finishing old pastered wall surfaces with the following treatments. a. 2 mm thick textured finish etc. , preparation and finishing new pastered wall surfaces with the following treatments a. 2 mm thick textured finish etc , supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating , providing and appliying aggregate textured wall coating in spectrum pigmented ornaplast finish , preparation and finishing new pastered wall surfaces with the following treatments. a. applying 1.5 to 2.0 mm thick uniform coating sand stone , rendering plaster 15 mm thick in cement mortar 1.4 in patches n.exc 3 sqm in repairs on brick or concrete surfaces of walls , taking down chowkhats or frames with shutters without taking off shutters from the frames , taking down chowkhats or frames with shutters without taking off shutters from the frames area exceeding 1.50sqm , demolition of brickwork built in cement mortar including all quoins arches pillars etc but excluding ashlars facings , demolition of reinforced cement concrete of any description and in any position not otherwise , demolition of cement concrete unreinforced in ground floors and pavings not excceding 15cm thickness , demolition of stone slabs kota stone granite slab of any description or thickness in floor etc , m and l preparing of new surface of wall and applying two coats of exterior emulsion paint , brick work using bricks old size bricks fly ash bricks straight or curved on plan exceeding 6.00 metre , brick work with sub class b bricks using old bricks as specified in straight or curved on plan exceeding 6.00 metre , brick work half brick thick wall using 1 33exceeding 6.00 metre , brick work half brick thick wall using 07 , s and f stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm , framed mild steel work such as grills grating etc. with ends of bars shouldered and or riveted or forged , sheet glass 4mm thick ordinary quality and glazing with oil putty or wooden beads in squares n. exc. 0.5 sq.mm , cement concrete 1.2.4 type b 0 using 12.5mm graded stone aggregate as in coping including necessary formwork , 100 mm thick cement concrete type d 2 1.4.8 using 40 mm graded stone aggregate finished even and rough , supply only fine aggregate sand for concrete for sand cushion for paver block. , m and l for machine pressed pre cast concrete interlocking paver block any shape and size confirming to is15658 2006 of 80 mm thick , mild steel tmt bars 10mm dia and over cut to length bent to shape required including cranking , m and l pre cast rcc 1.2.4 type b1 with 20mm graded stone aggregate as in manholes cover slab etc , preparation of old painted wood and wood based surfaces of any description not other wise described over 10cm width , preparation of old painted steel surfaces of any description not otherwise described over 10 cm width , 75 mm thick cement concrete type c 1 1.3.6 using 20 mm graded stone aggregate finished , granite any type and any shade 15 to 18 mm thick as in step jambs cooking platform and like , rounding of moulding to edges half round of stone of any description including rubbing and polishing , rendering 5 mm thick on fair faces of concrete surfaces finished fair and even on ceiling surfaces in cement mortar , two coats of synthetic enamel paint over and including a coat of red oxide primer , 500 litre capacity three layered polyethylene water storage tanks cylindrical vertical with closed top , 1000 litre capacity three layered polyethylene water storage tanks cylindrical vertical with closed top , preparation of old plastered unplastered old decorated surfaces of walls pillars cornices by brooming down or steel brushing , m and l preparing of new surface of wall and applying two coats of acrylic distemper over a coat of wall care putty , m and l for preparation of old surfaces of ceiling including scraping down smoke soot moulds , preparation of old treated surfaces of walls pillars cornices etc and applying one coat of water emulsion paint total quantity : 18419...

Punjab State Transmission Corporation Limited - Punjab

36085086 tender for extension of carrier room building at 132 kv s / s gholia kalan earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches , stacking the excavated soil clear from the edge of excavation and subsequent filling around masonary in 15 cm layers with compaction including diposal of all surplus soil as directed within a lead of 30 metres. 2 earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outsidethe building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres 3 dismantling brick work tile, masonry or tile lining : in cement 4 dismantling concrete: reinforced cement concrete 5 centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels 6 centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 7 cement concrete 1:8:16 with 40mm gauge stone aggregate. 8 cement concrete 1:6:12 withstone aggregate 40mm gauge(mixing by mechanical means using concrete mixer volumetric type) 9 cement concrete 1:2:4 with stone ballast or shingle (mixing by mechanical means using concrete mixer volumetric type) 10 reinforced cement concrete m 20 mechanically batch mixed using batch type concrete mixer as per is : 1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in superstructure . 11 damp proof course 7.5 cm thick of cement concrete 1: 2: 4 with two coats of bitumen 20/30 penetration at 1.65 kg per sqm laid hot and sanded. 12 first class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth . 13 first class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level. 14 first class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth 15 first class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level 16 extra for work done in additional storey up to 4m above the top of structural roof of lower storey 17 terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 kg/sqm top of rcc slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc. 18 top khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16 19 bottom khurra on ground 1.2mx0.6m consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3 20 cement concrete 1:2:4 gola 10cm x 10cmconcave quadrant along junction of roofs withparapet wall finished smooth, where speciallyspecified. 21 providing & fixing ceiling consisting of 600mmx600mmx12.5mm thick gypsum board g.i cradling hanged from the ceiling by means of g.i hanger complete as per drawings. 22 providing and fixing 110 mm dia swr upvc rain water pipe (ring fitted type a ) as per is : 13592 including jointing during masonary complete as per specifications and to the entire satisfication of engineer in charge.(if fixed on wall face clamp to be paid separatly as per respective item) 23 providing and fixing 110 mm dia swr upvc bend for rain water pipe as per is : 14735 including jointing as per specifications and to the entire satisfaction of engineer in charge. 24 base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material 25 conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material 26 conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material 27 providing and laying vitrified floor tiles of different sizes in light colour shades made using double charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to is : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( design is homogenous throughout the tile body ). 28 12.5 mm thick cement plaster 1:4 29 12.5 mm thick cement plaster 1:5 30 20 mm thick cement plaster 1:4 in two coat work 31 20mm thick cement plaster 1:5 in two coat work 32 10 mm th. cement plaster 1:4 under ceiling 33 applying priming coat with metal primer onnew steel or iron work including preparation ofsurface. 34 painting two or more coats with anti corrosive bitumastic paint to give an even shade 35 finishing walls with acrylic smooth exterior paint of required shade with 2 coats applied @ 1.67 ltr/10 sqmtr over & incluiding base coat of water proofing cement paint applied @ 2.20 kg / 10 sqm 36 wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) 37 preparation of plastered surface for oil bound distampered including sand papering the surface 38 cost of aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings(excluding sliding bolt) 39 providing and fixing hydraulic door closer isi mark with necessary screw etc. complete: isi designation no i (size of) 40 providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to is: 733 and is : 1285 of jindal, hindalco, mahavir or equivalent make approved by engineer in charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required pvc plug/neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/paneling, c.p.brass/stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. glazing and paneling to be paid for separately) : 41 providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to is: 733 and is : 1285 of jindal, hindalco, mahavir or equivalent make approved by engineer in charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required pvc plug/neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/paneling, c.p.brass/stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. glazing and paneling to be paid for separately) : 42 providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to is: 12823 grade l type ll, in paneling fixed in aluminium doors, windows shutters and partition frames with c.p. brass / stainless steel screws etc. complete as perarchitectural drawings and directions of engineer in charge.pre laminated particle board with decorative lamination on both sides. 43 providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with pvc plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . (cost of aluminium snap beading shall be paid in basic item) 44 providing and fixing aluminium sliding door bolts isi marked anodized (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with nuts andscrews etc. complete : 45 cold twisted detormed (ribbed/ tor s teel bar) bars (fe 500 grade as per is 1786 1985) , for r.c.c works, where not including in the complete rate of rcc including bending and biding placing in position complete. 46 providing & fixing stair case railing made out of ms square bars20x20m as vertical post 0.70mtr high 47 providing & fixing of 10 gauge welded mesh of 25mm x 25mm size fixed on steel glazing with ms flat 20mm x 6mm beeding complete in all respect including painting two coats with synthetic enamel paint and priming coat 48 recessed pvc conduit pipe wiring system with modular switches:wiring in pvc insulated copper conductor single core fr cable (isi marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge pvc conduit pipe 20mm/ 25mm dia. (isi marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with brass lugs) required for suitable number of modules (modular accessories) for having step type electronic fan regulators (two module) 100watts, bell push, 6amp. 2/3 universal socket (shuttered), 16/20amp. combined/ universal socket (shuttered), 6/10amp. switches, 16/20amp. switches with indicator etc. and covered with frame plate etc., pvc connector (for fan box and call bell), steel hooks, sheet metal fan box (1.6mm thick shape hexagonal), circular junction boxes (four way pvc 1½ deep for walls and ci 3 deep for ceiling), bonding to earth with pvc insulated copper conductor single core fr cable (isi marked) 1sq. mm, 1100volts grade (for 6amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface): 49 wiring fan point without fan box in pvc insulated copper conductor single core frls cable (isi marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts 50 wiring fan point with sheet metal fan box (shape hexagonal & sheet thickness not less than 1.60 mm) in pvc insulated copper conductor single core frls cable (isi marked) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts 51 wiring light point 52 wiring 6 amp plug control 53 wiring 3 pin 16/20 amp. power plug control (shuttered) and switch 54 supply and erection of pvc insulated fr single core unsheathed copper conductor cable (isi marked) suitable upto 1100 volts grade confirm to is:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the engineer in charge: 55 pvc insulated copper conductor single core frls cable (isi marked) overall 2.5 sq.mm, 1100volts grade 56 pvc insulated copper conductor single core frls cable (isi marked) overall 4 sq.mm, 1100volts grade 57 supply & erection of pvc conduit pipes (isi marked) as per is9537:part iii & hdpe pipes (isi marked) as per is:4984:1995 for wiring purposes including bends, junction boxes, steel hooks, m.s. saddle clamps and other petty materials etc., as per pwd general specifications: 58 heavy gauge pvc conduit pipe 25mm dia. (isi marked 2mm thick) on surface 59 supply and erection of miniature circuit breaker mcbs for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles ac supply with breaking capacity of 10ka, curve c and low watt losses as per is/iec 60898 1, energy limitation class 3, true contact indication, label holder facility in the existing mcb distribution board as per pwd general specifications including connections with suitable size of thimbles/lugs: 60 mcb single pole 0.5 4amp. (10ka, curve c) 61 providing andfixing general purpose tube fitting of 20watt of havells make 62 providing and fixing 18 dia exhaust fans in switch house building 63 supplying and fixing concealed tube fittingof 2 x 2 with electronic chok & cfltubes of wipro make ( model wcp 17236 sg) of 2 x 36 w (tc l) 64 providing and fixing electric ceiling fans with regulator complete in all respects 1400 mm sweep confirmingto is 374 / 79 duly amended up to date. 65 p&f m.s cable racks made of m.s angle iron for various size of 50x50x6 mm complete as per dwg 66 providing and fixing ms angle iron nosing made out of30x30x5 angle and flat 25x3 mm 600mm c/c wt 2.56 kg/mtr. complete in all respects 67 supply & placinfg in positions cheqquerred plate 5 mm thicki/c cutting & grinding of edges complete in all respects 68 extra carriage of materials & diff. of rates of material cement 69 extra carriage of materials & diff. of rates of material steel 70 extra carriage of materials & diff. of rates of material fine sand 71 extra carriage of materials & diff. of rates of material coarse sand 72 extra carriage of materials & diff. of rates of material crushed bajri 13.2mm 73 extra carriage of materials & diff. of rates of material crushed bajri 11.2mm 74 extra carriage of materials & diff. of rates of material stone metal 40mm 75 extra carriage of materials & diff. of rates of material bricks 76 extra carriage of materials & diff. of rates of material tiles ...

Punjab State Transmission Corporation Limited - Punjab

36085078 tender for extension of carrier room building at 132 kv s / s sosan earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches , stacking the excavated soil clear from the edge of excavation and subsequent filling around masonary in 15 cm layers with compaction including diposal of all surplus soil as directed within a lead of 30 metres. 2 earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outsidethe building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres 3 dismantling brick work tile, masonry or tile lining : in cement 4 dismantling concrete: reinforced cement concrete 5 centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels 6 centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. 7 cement concrete 1:8:16 with 40mm gauge stone aggregate. 8 cement concrete 1:6:12 withstone aggregate 40mm gauge ( mixing by mechanical means using concrete mixer volumetric type ) 9 cement concrete 1:2:4 with stone ballast or shingle ( mixing by mechanical means using concrete mixer volumetric type ) 10 reinforced cement concrete m 20 mechanically batch mixed using batch type concrete mixer as per is : 1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in superstructure . 11 damp proof course 7.5 cm thick of cement concrete 1: 2: 4 with two coats of bitumen 20 / 30 penetration at 1.65 kg per sqm laid hot and sanded. 12 first class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth . 13 first class burnt brick work laid in cement sand mortar 1:5 in first storey up to 4 metres above plinth level. 14 first class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth 15 first class burnt brick work laid in cement sand mortar 1:4 in first storey upto 4 metres above plinth level 16 extra for work done in additional storey up to 4m above the top of structural roof of lower storey 17 terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another laver of 25mm mud plaster including two coats of bitumen laid hot at 1.65 kg / sqm top of rcc slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc. 18 top khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16 19 bottom khurra on ground 1.2mx0.6m consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3 20 cement concrete 1:2:4 gola 10cm x 10cmconcave quadrant along junction of roofs withparapet wall finished smooth, where speciallyspecified. 21 providing & fixing ceiling consisting of 600mmx600mmx12.5mm thick gypsum board g.i cradling hanged from the ceiling by means of g.i hanger complete as per drawings. 22 providing and fixing 110 mm dia swr upvc rain water pipe ( ring fitted type a ) as per is : 13592 including jointing during masonary complete as per specifications and to the entire satisfication of engineer in charge. ( if fixed on wall face clamp to be paid separatly as per respective item ) 23 providing and fixing 110 mm dia swr upvc bend for rain water pipe as per is : 14735 including jointing as per specifications and to the entire satisfaction of engineer in charge. 24 base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling using mechanical mixer for mixing of material 25 conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material 26 conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material 27 providing and laying vitrified floor tiles of different sizes in light colour shades made using double charge technology ( thickness to be specified by the manufacturer ) with water absorption’s less than 0.08% and conforming to is : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement: 4 fine sand ) , complete. ( design is homogenous throughout the tile body ) . 28 12.5 mm thick cement plaster 1:4 29 12.5 mm thick cement plaster 1:5 30 20 mm thick cement plaster 1:4 in two coat work 31 20mm thick cement plaster 1:5 in two coat work 32 10 mm th. cement plaster 1:4 under ceiling 33 applying priming coat with metal primer onnew steel or iron work including preparation ofsurface. 34 painting two or more coats with anti corrosive bitumastic paint to give an even shade 35 finishing walls with acrylic smooth exterior paint of required shade with 2 coats applied @ 1.67 ltr / 10 sqmtr over & incluiding base coat of water proofing cement paint applied @ 2.20 kg / 10 sqm 36 wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade ( two or more coats ) 37 preparation of plastered surface for oil bound distampered including sand papering the surface 38 cost of aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings ( excluding sliding bolt ) 39 providing and fixing hydraulic door closer isi mark with necessary screw etc. complete: isi designation no i size of 40 providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections conforming to is: 733 and is : 1285 of jindal, hindalco, mahavir or equivalent make approved by engineer in charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required pvc plug / neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p.brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. glazing and paneling to be paid for separately ) : 41 providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections conforming to is: 733 and is : 1285 of jindal, hindalco, mahavir or equivalent make approved by engineer in charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required pvc plug / neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p.brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. glazing and paneling to be paid for separately ) : 42 providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to is: 12823 grade l type ll, in paneling fixed in aluminium doors, windows shutters and partition frames with c.p. brass / stainless steel screws etc. complete as perarchitectural drawings and directions of engineer in charge.pre laminated particle board with decorative lamination on both sides. 43 providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with pvc plug / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) 44 providing and fixing aluminium sliding door bolts isi marked anodized ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade with nuts andscrews etc. complete : 45 cold twisted detormed ( ribbed / tor s teel bar ) bars ( fe 500 grade as per is 1786 1985 ) , for r.c.c works, where not including in the complete rate of rcc including bending and biding placing in position complete. 46 providing & fixing stair case railing made out of ms square bars20x20m as vertical post 0.70mtr high 47 providing & fixing of 10 gauge welded mesh of 25mm x 25mm size fixed on steel glazing with ms flat 20mm x 6mm beeding complete in all respect including painting two coats with synthetic enamel paint and priming coat 48 recessed pvc conduit pipe wiring system with modular switches:wiring in pvc insulated copper conductor single core fr cable ( isi marked ) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge pvc conduit pipe 20mm / 25mm dia. ( isi marked ) recessed in wall etc., complete with powder coated / anodized concealed metal boxes ( 1.6mm thick with brass lugs ) required for suitable number of modules ( modular accessories ) for having step type electronic fan regulators ( two module ) 100watts, bell push, 6amp. 2 / 3 universal socket ( shuttered ) , 16 / 20amp. combined / universal socket ( shuttered ) , 6 / 10amp. switches, 16 / 20amp. switches with indicator etc. and covered with frame plate etc., pvc connector ( for fan box and call bell ) , steel hooks, sheet metal fan box ( 1.6mm thick shape hexagonal ) , circular junction boxes ( four way pvc 1½ deep for walls and ci 3 deep for ceiling ) , bonding to earth with pvc insulated copper conductor single core fr cable ( isi marked ) 1sq. mm, 1100volts grade ( for 6amp. wall socket & plug control point ) and other petty material etc., including the cost of above material, cutting and filling up of chases ( with finishing the surface ) : 49 wiring fan point without fan box in pvc insulated copper conductor single core frls cable ( isi marked ) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts 50 wiring fan point with sheet metal fan box ( shape hexagonal & sheet thickness not less than 1.60 mm ) in pvc insulated copper conductor single core frls cable ( isi marked ) overall 1.5 sq. mm, 1100volts grade with step type electronic fan regulator 100watts 51 wiring light point 52 wiring 6 amp plug control 53 wiring 3 pin 16 / 20 amp. power plug control ( shuttered ) and switch 54 supply and erection of pvc insulated fr single core unsheathed copper conductor cable ( isi marked ) suitable upto 1100 volts grade confirm to is:694 / 1990 left bare in pipe or casing of suitable size complete in all respect as desired by the engineer in charge: 55 pvc insulated copper conductor single core frls cable ( isi marked ) overall 2.5 sq.mm, 1100volts grade 56 pvc insulated copper conductor single core frls cable ( isi marked ) overall 4 sq.mm, 1100volts grade 57 supply & erection of pvc conduit pipes ( isi marked ) as per is9537:part iii & hdpe pipes ( isi marked ) as per is:4984:1995 for wiring purposes including bends, junction boxes, steel hooks, m.s. saddle clamps and other petty materials etc., as per pwd general specifications: 58 heavy gauge pvc conduit pipe 25mm dia. ( isi marked 2mm thick ) on surface 59 supply and erection of miniature circuit breaker mcbs for circuit protection against overload and short circuit current fault suitable for 240 / 415 volts 50cycles ac supply with breaking capacity of 10ka, curve c and low watt losses as per is / iec 60898 1, energy limitation class 3, true contact indication, label holder facility in the existing mcb distribution board as per pwd general specifications including connections with suitable size of thimbles / lugs: 60 mcb single pole 0.5 4amp. ( 10ka, curve c ) 61 providing andfixing general purpose tube fitting of crompton make on wall ( model dijb12414eb9 ) of 1x36w 62 providing and fixing 18 dia exhaust fans in switch house building 63 supplying and fixing concealed tube fittingof 2 x 2 with electronic chok & cfltubes of wipro make ( model wcp 17236 sg ) of 2 x 36 w ( tc l ) 64 providing and fixing electric ceiling fans with regulator complete in all respects 1400 mm sweep confirmingto is 374 / 79 duly amended up to date. 65 p&f m.s cable racks made of m.s angle iron for various size of 50x50x6 mm complete as per dwg 66 providing and fixing ms angle iron nosing made out of30x30x5 angle and flat 25x3 mm 600mm c / c wt 2.56 kg / mtr. complete in all respects 67 supply & placinfg in positions cheqquerred plate 5 mm thicki / c cutting & grinding of edges complete in all respects 68 extra carriage of materials & diff. of rates of material cement 69 extra carriage of materials & diff. of rates of material steel 70 extra carriage of materials & diff. of rates of material fine sand 71 extra carriage of materials & diff. of rates of material coarse sand 72 extra carriage of materials & diff. of rates of material crushed bajri 13.2mm 73 extra carriage of materials & diff. of rates of material crushed bajri 11.2mm 74 extra carriage of materials & diff. of rates of material stone metal 40mm 75 extra carriage of materials & diff. of rates of material bricks 76 extra carriage of materials & diff. of rates of material tiles...

Military Engineer Services - Punjab

35481451 tender for certain repair to esh building and accn in fasf under age br ii at nams &f for 15 mm bor gi tube medium grade freed to wall or under floor incl taking up or down old tube complete including cutting closes and make good in cm 1:3 complete all as specified and directed. 2 s& f in repair20 mm bore g.i tubing in new or old location ( wall / roof ) with all fittings incl taking up or down old tube complete all as specified and directed. 3 fixing only in repair steel tubing and connection 20 mm dia bore to wall and laid in floors incl taking up or down old tube and cleaning for refixing complete all as specified and directed. 4 s&f for rotational moulded polythene 500 litres water storage tanks cylindrical vertical with closed top hoisted and fixed in position incl 20 mm dia float valve with aluminium fitting incl old disconnecting and taking down complete all as specified and directed. 5 all as per item above but 1000 litres water storage tanks. 6 all as per item above but 2000 litres water storage tanks. 7 m&l for brickwork with subclass b bricks ( old size bricks ) , straight or curved on plan exc 6m mean radius, built in cm 1:6 complete incl demolition of brickwork / stone built in cement mortar etcall as specified and directed. 8 all as per item above here in before but except bricks complete all as specified and directed. 9 m&l for brick work with sub class ‘b’ bricks ( old size brick ) straight or curved on plan to any radius in half bricks thick walls, built in cm 1:4 complete incl demolition of brickwork / stone built in cement mortar etc all as directed. 10 m&l for rendering 15 mm thick cement plaster in cm 1:6 onbrick work or concrete surfaces including finished even and smooth without using extra cement all as specified and directed. 11 m&l, rendering 15mm thick in cm 1:4 onof brick work or concrete surfacefinish ever and smooth ( w / o using extra cement ) incl wpc as per user manual complete all as specified and directed. ( wpc will be measured and paid separately ) . 12 m&l, rendering 15mm thick in cm 1:6 onof brick work or concrete surfacefinish even and smooth ( w / o using extra cement ) incl taking down old plaster on brick or stone walls , scrubing down with water etc & dispose off debris where directed by eic, complete all as specified and directed. 13 m&l, rendering 15mm thick in cm 1:4 onof brick work or concrete surfacefinish even and fair ( w / o using extra cement ) incl taking down old plaster on brick or stone walls , scrubing down with water etc & dispose off debris where directed by eic, complete all as specified and directed. note : ( wpc shall be measuared seperatly and @ 3% by weight of cement / 200ml for 50kg cement bags or as per manufacturers instructions ) . 14 supply only liquid wpc complete all as specified. 15 m&l, rendering 10mm thick in cm 1:3 over concrete surface as on ceiling finish even and smooth w / o using extra cement incl taking down old plaster on ceiling , scrubing down with water etc & dispose off debris where directed by eic, complete all as specified and directed. 16 m & l for three coat of white wash incl preparation of new plaster surface of ceiling complete all as specified and directed. 17 m&l for two coat of oil bound distemper by spray machine over one coat of primer on new plasterd surfaces of walls, pillars cornces etc incl prepartion of new plastered surfaces through electrical operated grinder complete all as spd and directed 18 m&l for applying two coats of cement base paints over one coat of primer on walls etc, incl preparing new surfaces of walls by brooming down or by steel wire brushing complete all as directed . 19 m&l fortwo coat ofacrylic smooth exterior emulsion paint on walls, pillars cornices etc surfaces by spray machine over one coat of primer incl preparation of new plasterd surface complete all as spd and directed. note : colour and make as approved by engr in charge 20 m&l for applying two coats of oil bound distemper by spray machine incl preparation of oldsurface by complete removal existing treatement on walls through electrical operated grinder etc, incl necessary minor repair of wall by putty complete all as spd and directed. 21 m&l for applying two coats of cement base paints on walls etc, incl preparation of oldsurface and complete removal existing treatement on wall complete all as specified and directed. 22 m&l fortwo coat ofacrylic smooth exterior emulsion paint on walls, pillars cornices etc surfaces by spray machine on old plastered / unplastered surfaces of walls, pillers, corniceson incl preparation of old surfacesthrough electrical operated grinder complete incl edges overto obtain smooth finish using sand paper, over one coat of primer complete all as specified and directed. 23 m&l for one layer of compound of altek / birla putty 3mm th on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as spd and directed. 24 m & l for repair to rcc chajjas, roof projection edges , hanging part of chajjas, edges ofchajjas, rcc parapets, under the roof / floor slabs with pcc 1:2:4 ( using 12.5mm crushed graded agg ) incl neccasary renforcement 8mm to 12mm tmt bars , form work, ms wire mesh for boundingthe concreteonground requiredand plaster work in cm 1:3 & periodical services to match with the existing surfaces finishing at any height of buildings etc completed all as specified and directed by engr in charge. 25 s&f in repair for 3mm thick, sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exc 0.5 sqm in each pane fixed with oil putty or beads and incl hacking out glass old complete all as specified and directed. 26 s&f in repair for stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples / beading complete all as specified and directed.. 27 m & l for pcc 1:4:8 type d 2 ( using 40 mm agg. ) in sub base of flooring incl demolition complete all as specified and directed. 28 m&l for non skid ceramic any coloured / printedtiles 7 to 8 mm thick ( square / rectangular ) area of each tile exc 0.06 sqm but not exc 0.11 sqm as in floor of shade & designed as approved by ge, set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles, over15 mm thick rendering as screed bed in cement mortar ( 1:4 ) in floors, incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. 29 all as per item above but area of each tile exe 0.11 sqm but n.exe 0.18 sqm, in floors & dado etc complete all as specified and directed. 30 m&l for glazed ceramic coloured / printed / dark tiles size 300x200mm x7mm thick on vertical surface in skirting / dado , set and jointed in neat cement slurry and pointed with white cement with pigment to match the colour of tiles, 10 mm thick rendering on fair faces of concrete surface ofverticle in cm ( 1:3 ) finished even and smooth without using extra cement complete, shade & design as approved by eic / ge, incl dismantling and rubbish off the primises etc all as specified and directed. 31 all as per itemabove but area tiles of size exc 0.09sqm but n.exc 0.18sqm on vertical surface in skirting / dado etc. 32 m&l for virified ceramic tiles light / dark shade 10 mm thick ( square / rectangular ) polished, area of each tiles not exc 0.36 sqm , in floors, on vertical surfaces of wall etc. set and jointed in neat cement slurry over 15 mm thick screed bed or bedding layer in cm 1:6 for laying floor finishes and pointed in white or coloured cement to match and incl dismantling / demolition and rubbish off the primises etc complete all as speciefied and directed. 33 all as per item above butarea of each tiles exc 0.36 sqm butnot exc 0.42 sqm, complete all as speciefied and directed. 34 m&l for green marble 15 17 mm thick over cement screed bed laid on 15 mm thick cm 1:6 andjointed with grey cement slurry mixed with pigment ot match the shade of the slab / staircase / steps, riserincl rubbing and polishingincl moulding rounding to edge of marble & dismantling complete all as specified and directed. 35 m&l for granite 18 20mm thick ( of any type ) work ( table rubbed and polished ) in steps, jambs, pillars, window cills, cooking platforms, wash basin platform and like in cement mortar ( 1:6 ) including pointing in white cement ( 1:2 ) using marble dust with admixture of pigment to match with shade of granite incl moulding , rounding of edgeing and dismantling complete all as spd and directed. 36 s&f in repair 18 / 19 mm prelaminated particle board, prelaminated both side with decorative choice lamination & other side balancing white lamination , fixed with screws to timber / steel frame work ( incl 2 nos 100mm aluiminium handles, 1 nos 100mm hasp & staples for each shutter ) complete all as specified and directed. 37 m & l forpcc 1:3:6 type c 2 ( using 40mm agg. ) in plinth protection, path and pavingincl demolition and rubbish off the primises all as specified and directed. 38 m & l forpcc 1:2:4 type b 2 ( using 40mm graded stone aggregate ) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement , rubbish off the primises and incl demolition complete all as spd & directed . 39 s&f mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides ) and hanging; also fastening and fixing conforming to fe 290 grade e 165, complete all as specified. 40 s&f for 40mm thick flush shutters, solid core construction, with blockboard core and plywood face panels, commercial type on both sides incl taking down shutter & two coat of synthetic enamel paint over a coat of red oxide on wooden surface and cutting holes in frames of any type / walland making good dismantled portion in pcc 1:2:4 type b 1 / cement plaster 1:4 as require and make finish good to the existing surface and the followingbuilders hardware contain each shutter : ( i ) three x ms butt hinges, medium weight, cold rolled mild steel 100mm long ( isi marked ) with welded or screwed as required. ( ii ) two x aluminum anodized barrel tower bolts of extruded section 150mm long ( isi marked ) . ( iii ) two x aluminum handles cast type anodized 150mm long ( isi marked ) . ( iv ) two x aluminium alloy, anodised, sliding door bolt of 250mm long & 16mm dia with hasp, staple ( bolt type ) and fixing clips of sheet, complete all as specified and directed. 41 s&f for 110mm bore pvc pipes single socketed pressure rating @4kg / sq cmlength medium grade with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up / down old pipe with all fittings all as specified and directed by engineer in charge. 42 all as per item above but laid in trench or in floor complete all as specified and directed. 43 s&f for 125 / 110mm bore pvc gully trap setting / jointed with solvent cement complete all as specified and directed.. 44 s&f for 110mm bore pvc bends / junctionany radius complete all as specified and directed.. 45 m&l in repair for pvc hollow wall panelling 7 to 8mm thick any colour / design approved by engr in charge, inclusive of fixing on to wall incl moulding end caps fixed with pvc sleeves, screws as required at site & dismantling complete all as specified and directed 46 m & l for one coat of synthetic enamel paint on steel surface incl preparation of old steel surface width or girth exc 10cm all as specified and directed. 47 m&l for one coats of synthetic enamel paint on wooden surfaces of any description over 10cm width or girth including preparation of old surfaces complete all as specified and directed. 48 s&f for 2nd class hard wood glazed and skelton door shutters 35mm thick, open rebated and prepared to received glass / gauge etc ( without sash bars ) edges of framing plain, chamfered or rounded and mitred , beads for securing glass etc the size of member of shutter as specified in ssr part i clause 8.23 ( b ) and fitted to chowkahts fixed with stainless steel wire cloth 0.36mm nominal dia of wireand average width of aperture 1.40mm fixed with wire staples or wooden beads incl taking down shutter and two coat of synthetic enamel paint over a coat of red oxide on wooden surface & cutting holes in frames of any type / walland making good dismantled portion in pcc 1:2:4 typeb1 / cement plaster 1:4 as require and make finish good to the existing surface & incl the followingbuilders hardware contain each shutter : ( i ) three x ms butt hinges, cold rolled mild steel 100mm long ( isi marked ) with welded or screwed as required. ( ii ) two x aluminum anodized barrel tower bolts of extruded section 150mm long ( isi marked ) . ( iii ) two x aluminum handles cast type anodized 150mm long ( isi marked ) .complete all as specified and directed. 49 m&l for preparation of roof surface & applying evenly a tack coat of industrial bitumen 85 / 25 grade @ 1.2 kg / sqmincludingapp based polymeric membrane minimum weighing 3 kg / sqm and minimum 3 mm thick reinforced wih polyster non wove fabric ( wt not less than 150 gms / sqm ) land on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mmincl rendering 10mm thick in cm 1:3withwpc in sunken slab / wall complete all as specified and directed. 50 m&l, cement concrete 1:7:12 ( 40 mm graded aggregate ) in lean concrete including demolition complete all as specified and directed. 51 s & f solid pvc door frame of size 50 x 47 mm made out of 5 mm plain colour pvc sheet reinforced with ms square tube incl taking down old frame any type complete all as specified and directed. 52 s&f factory made solid panel pvc door shutter 30 mm thick ( style ) consisting of frame made out of ms tubes for top & bottom rails ms frame shall be convered with heat moulded plain colour pvc `cchannel having a pvcsheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour pvc sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain colour pvc sheet to be fitted in the ms frame welded / sealed to the stiles and raials with suitabale pvc sheet beading, and jointed together with solvant cement, fixing in the frame at side as per specification and drawing incl taking down old shutter complete all as specified and directed complete all as specified and directed. 53 s & f for butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, 100mm, type c 21 complete all as specified and directed. 54 s&f for aluminum handles cast type anodized 100 mm long ( isi marked ) complete all as specified and directed. 55 s&f for 150mm aluminium anodised barrel tower bolts of extruded section and fixed isi marked complete all as specified and directed. 56 m&l for box type steel window 1.25 mm thick made of erw tube p section of size 60 x 25 mm double rebated outer frame comprise of glazed skeleton shutter ( two gauged shutters and two glazed shutter ) of erw tube p section size 50 x 20 mm and 1mm thick one / two nos openable leaf consisting of two nos sash bar of t section 20x3mm welded to frame with one no vertical mullion of erw box type t section of size 60 x 25 mm and 1.25 mm thick and fi 2 mm thick welded / screwed to frame for fixing of glass including fittings and fixture like handle, tower bolt, stopper, cleat, pintal hinges, hold fast etc. ( i ) hold fast, 150mm long of 120mm x 3 mm made to shape 04 nos per window. ( ii ) handle of z sec 20mm x 25mm, 100 mm long 1 no per leaf ( iii ) ms tower bolt 150mm long 2 no per leaf ( iv ) z sec 20mm x 25 mm, 100 mm long stopper 1 no per leaf ( v ) cleat 55 mm long of hollow square 15mm x 20mm x.63mm welded to hinge 1 no per leaf. ( vi ) ms pintal hinges of size 75mm x 12mm 2 nos per leaf . ( vii ) 10 mm square guard bar, 10 cm centre to centre. ( viii ) 25x4 mm flat iron all around for joint of both frame. ( ix ) stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples& 3mm thick, sheet glass ordinary quality and glazing with oil putty . ( x ) two coat of synthetic enamel paint to ms window and guard bar. note : incl taking down old steel / wooden window and making good dismantled portion with pcc 1:2:4 type b0 incl hold fast pcc ( four no’s for each window ) & around required plaster in cm 1:4 and match with existing finishing complete all as specified and directed by engineer in charge. 57 m&l for anodised aluminium framed workfor door, window / vent ( powder coated ) aluminium section weighting 0.55kg / rm with one or more rebated incl jointed cleat for fixing etc complete all as specied and directed 58 m&l for anodised aluminium powder coated door, window and ventilator shutters, aluminium section weighting 0.55kg / rm fixed type without sash bar, incl necessary 4.8mm th sheet glass ordinary quality & glazing / black or pvc sheet joining with cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, lock , 2 nos aluminium handles 150mm, 2 x aluminium tower bolts 150mm with each shutter any type complete all as specified all as specified. 59 m&l anodized aluminium window shutter sliding type with2 track side and bottom framehaving 75 mm x 44 mm x 3 mm thick stiles bottom rail and top rail includingdouble shutters 2 nos glazed ang gauzed shutters each, necessary ftting joinery cleat glasing packing snap beading 10 mm x 10 mm , 2 nos of anodixed aluminium handle 150 mm size, including sliding rulers, 2 nos of 100 mm long alu tower bolt etc inlcuding frame of section 100 mm x 44 mm x 3 mm and including 5.00 mm thick floatglassand fixing incl taking down old ms / aluminium window complete all as specified & directed by engineer in charge.make of aluminium section hindalco / jindal 60 s&f aluminium wire guard mesh of 4mm nominal dia of wire and average width of aperture 75 85mm and fixed with aluminium frame / staples complete all as spd and directed 61 m&l for 4.8 to 5.5mm thick float glass ordinary quality, glazing or black with aluminum beeding and gasket to aluminum frameworkin squareexc 0.50 sqm ineach pane in repair complete all as specified. 62 s & ffor 12 mm thick glass door, frosted with certain logo, fixed with floor spring, fixed on floor with two nos stainless steel handle oneach leaf incl necessary provision to lock the door completed all as specified and directed. 63 s&f for pre painted galvalume aluminum zinc coating gi based corrugated / plain steel sheet 0.50mm thick of an colour profile az 150 with side lap as in roof covering / cladding to wall, ridge etcfixed with l or j hooks / self tapping screws and incldismantling of plain or corrugated steel / ac sheeting in roof covering all as specified and directed by eic. 64 all as per above item here in –before but except sheeting. 65 s / f steel work in tubular trusses and posts, vertical / horizontal bar, chin up bar and similar work including special shaped washers, chequered plates, etc complete using butt welded tubes conforming to is 1161 1979 graded st 240 with one shop coat of zinc chromate primer including dismantling of old mild steel of any description complete all as specified and directed. 66 excavating in post holes ( or similar holes ) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to a distance not exceeding 100 mtr making goodin soft / loose soil complete all as specified and directed. 67 m&l for pcc ( 1:3:6 ) , type c 2, using 40 mm graded aggregate as foundation / mass concrete complete all as specified and directed. 68 m & l for chequered tiles of size 300 x 300 x 25 mm thick ( colour and glazed approved by eic ) with grey cement and pigments laid over 15 mm thick screed bed in cm 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed. 69 m&l for machine pressed precast concrete interlocking paver block any shape and size confirming to is 15658 2006 of 60mm thickness, with grey cement, pigment with 25mm thick sand fillingincl dismantling and rubbish off the primises all as specified and directed. 70 all as per item above but except paver block shall be reused after necessary cleaning and making good all as specified. 71 m&l for broken bricks hard core gauge n.exc 63mm deposited, spred and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces. 72 s & f dor plain gypsum board panel 12.5mm thick on ceiling with and incl necessary gi frame used with t or any section accessories etc of galvanized steel all as per manufacturer design conforming to is 2095 and 2542 ( 1981 ) the weight of the board shall be not less than 7 kg per sqm incl dismantling of walls and ceiling board any type and two coat of obd over a coat of putty complete all as specified and directed.make.everest, gyprock.amstrong. 73 m&l for pointing to brick tiles in cm 1:3 laid flat in roofing incl racking out joints complete all as specified . 74 m&l for pcc1:3:6 type c2 as in roof pading ( average th 40mm ) ( using 12.5 mm graded aggregate ) complete all as specified and directed. 75 m & l for applying two coat of undiluted thick coat of acrlic reinforcement liquid applied elastorneric water proofing membrane with uv resistance properties and solar refective properties over one coat of primer ( 1:3, dilution:water ) note: every each coat gap between 6 hrs ) complete all as specified and directed.make : asian paint, sika, fosroc 76 s & f in repairfor viterous china squating pan of ( orrissa pattern ) size 580 mm white with p or s trap front or back inlet and integral foot rest ( excluding flushing cisteern and flush pipe ) fixed inclcement concrete bedding as required set complete all as specified and directed. 77 s & f in repair for viterous china wash down water closet pan ( pedestal pattern ) coloured includingp or s trap with flush pipe of chromium plated brass 32 mm dia for low levelflushing cistern incl plastic seat cover white closed pattern with float bottom and cover and jet connection and mild steel chrominum plate or aluminized hanging device fixed in repairs complete all as specified and directed. 78 s & f in repair for viterous china wash hand basin white flat back size 550 x 400 mm with leg incl cp waste coupling, waste pipe & plug and porclain stopper brackets and cutting for and pinning in ends of brackets or erceting stand fixed complete all as specified and directed. 79 s & f in repairvitreous china ware over counter ovel wash hand basin, any colour, size 570 x 450 mm sizeincluding cutting for and pinning ends of brackets or erecting stand including fixing waste pipe , cp waste coupling & bottle trap all as specified and approved by enger in charge. 80 s&f in repair 10 ltr capacity low levels flushing cistern with pvc bend and pvc flush down pipe etc complete all as specified and directed. ( make : parryware / hindware ) 81 s & f in repair bib tap cp fancy type / long body15 mm bore with will crutch or buttewrfly handle screwed down screwed to iron pipe complete with all fittings all as specified and directed. 82 s & f in repair angle cockcp fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for unions complete all as specified and directed. 83 s & f in repair stop cock concealed long shank chromium plated fancy type 15 mm borescrewed down high pressure with crutch or butter fly handle complete all as specified and directed. 84 s& f for in repair swan neck pillar cock chromium plated fancy type screw with iron pipe incl all fittings complete all as specified and directed . 85 s&f in repair hole washbasin mixer wround spoutwith 375 mm long braided hosescomplete all as spd and directed. 86 s & f in repairwall mixer 15 mm bore ( fancy type ) cast copper alloy with capstan head, cp screwed down high pressure with long screwed both ends for iron pipe as per union complete all as specified and directed. 87 s& f for looking mirror of best size ( 600 x 450 ) mm bevelled edged mirror of selected quality glass mounted on 6mm th ac building board, aluminium channel around fixed with provision of hanging hooks complete all as specified and directed. 88 s&f in repair for door closer hydrulicacally, alluminium regulated designation no 1 universal type suitable for door shutter complete all as specified and directed. 89 s&f for pvc connections 45cm long superior quality with ptmt nut on both sidecomplete all as specified and directed. 90 s&f for 100mm bore cast iron soil, waste and vent pipes, in any lengthwith or without ears, with cement joints, fixed to walls etcincl taking down old pipe complete all as specifed and dirtected. 91 s&f for 100mm bore ci bends ( any radius ) , diminishing pieces or tapers ( larger bore measured ) 92 m&l for taking down rolling shutter size exc 5 sqm but n. 16 sqm and refixing in position after necessary repair to welding work, repair / replacement of ball bearing chain wheels, anchor rod , gear box etc incl greasing & easing of rolling shutter and applying a coat of synthetic enamel paint on steel surfaces complete all as specified and directed. 93 ditto all as per item above but shutter size exc 16 sqm but n. exc 28 sqm complete all as specified and directed. 94 m & l for providing pre cast cement concreate louvers and jallers 40m thick set in cement motor 1:4 of type b1:2:4 ( 12.5mm graded stone aggrigate ) measured solid all mounding but including frame, taking down etc coplete all as speified and directed. 95 m & l for providing pre cast cement concreate ( rcc jali piller ) size of piller 100x100x700mm and taking down compleateall as speified and directed. 96 s&f inrepair 300mm ms rat tail road ordinery pattern spring including roller and roller plate complete all as specified and directed. 97 s&f in repair floor door stoper of aluminum with hand down steel spring fixed in floors overall length of cover plate 140mm compleate 98 taking down of old gate, area n exc 15 sqm and erection and refixing the same aftermaking it serviceable, easing, renewing and greasing, oiling complete including cutting, filling for hold fast incl making good in pcc 1:2:4, type b 0 as required, including one coat of synthetic enamel paint to ms gate as required complete all as specified and directed. 99 m&l machine cut kota stone of size 45 x 60cm or 60 x 60cm, mirror polished ( selected quality ) slab flooring 20 to 25 mm thicklaid in slope and jointed with grey cement slurry mixed with pigment to match the shade of slab, over and including screed bed of 20mm thick in cm 1:4, complete, all as specified and as directed by engr in charge. 100 m&l for forming 12mm thick expansion joints filled with pre formed bituminous filler and top 30mm primed and sealed with sealing compound, grade b in on concrete slab all as specified and directed. 101 taking down carefully the existing aluminium / copper point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets, ceiling rose, regulators and light fittings any type etcby unscrewing and taken away from site complete.note :cost of unserviceable materials will be charged from the contractor against schedule of credit. 102 m & l for point wiring for one light point / bell / fan point controlled by one switchcomplete with 1.5 sqmm single core pvc insulated unsheathed cable 1100 volts grade, multistranded with copper conductors conforming to is specifications, drawn through and including conceled conduitconcealed / fixed on wall / ceiling with suitable clamps, screws, etc or concealed in wall including terminal boxes fabricated with 1.6 mm ms sheet concealed in walls covered with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch sockets outlets, fan regulators, etc, including provn of 1.5 sqmm pvc insulated unsheathed cable with multistranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified and as directed : 103 all as per item no 101 here in before but with one 3 pin 5 amps switch socket on independent board. 104 all as per item no 101 here in before but withone 3 pin 5 amps switch socket on same board. 105 all as per item no 101 here in before but with cable 2.5 sqmm ( nominal area ) multistranded copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continous earth wirte pvc insulated 2.5 sqmm copper multistranded conductor connecting to common earth and earth dolly complete all as specified and directed 106 supply and fix switch piano one way 5 a, sp, 230 volts. 107 supply and fix ofswitch 16 amps flush type. 108 supply and fixing of socket outlet two in one, 3 pin each suitable for 5amperes flush type, 230 volts ac complete all as specified and directed. 109 supply and fixing of socket outlet two in one, 3 pin each suitable for 15amperes flush type, 230 volts ac complete all as specified and directed. 110 supply and fix stepped type electronic fan regulator flush type all as specified and directed. 111 supply and fixing ceiling rose surface bakelite3 terminals 65x32mm complete all as specified 112 s&f lamp holder, pvc / polycarbonate type with cord grip cap suitable for pendant / batten fittings including led bulb 9 watt, 230 volt complete all as specified and directed 113 s&f distribution boarddouble doormade out of crca mild steel sheet surface with insulated material like polyester or with epoxy powder coating and ip 43 & ik 09 protection surface mounting spn 12 way, 240 volts with bus bar rating 200 amps, dust and vermin proof suitable for incorporation of mcb’s and isolators etc complete all as specified. make :legrand / hager / schneider elect . ( note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash / colour / distemper etc is included in quated rate ) 114 supply and fixing in replacement of led t 8 tube light fitting with single side connection polycarbonateled tube rod 18 / 20 / 22w 4 feet with crca box suitable box complete including rotary type bipin holder and connection with pvc insulalted twin core 23 / 0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed. make : wipro cat part no for ftl wi0922208p , tube light ll13 181 65se , havells cat part no for ftl 1 x 22 / 20 wssbswh tube light sstl20wled865spc, crompton cat part no ftl1gp131lt8 16 tube light ltt8 20 & orient cat part no libt 188 55 rated power ( 01 x 18 / 20wt 8 led tube ) note: led box and led channel should be of same make 115 m & l for sub main wiring with pvc insulated, 1100 volts grade single core multistranded copper conductor cable conforming to is specifications, 2 runs of 6sqmm including 1 run of 6 sq mmsingle core multistranded copper conductor, pvc insulated cables as earth continuity conductor drawn through and including one run of 25 mm dia rigid pvc conduit and conduit accessories fixed on wall / ceiling etc., or concealed in wall and connecting to common earth dolly all as specified and directed including taking down all sub main wiring . make of frls wire; polycab / havells / rr cable, make of pvc pipe polycab / finolex / kalinga premium. note :2 run of 6 sqmm, 1 run of 6 sq mm and 1 run of pvc conduit will bemesuared as 1 unit. 116 s&f distribution boarddouble doormade out of crca mild steel sheet surface with insulated material like polyester or with epoxy powder coating and ip 43 & ik 09 protection surface mounting spn 8 way, 240 volts with bus bar rating 200 amps, dust and vermin proof suitable for incorporation of mcb’s and isolators etc complete all as specified. . ( note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash / colour / distemper etc is included in quated rate ) 117 s & fin repair mcb spn, 240 volts, 40 to 63 ampere, rupturing capacity 10 ka, ‘b’ curve type complete all as specified and directed.make :legrand / hager / schneider elect 118 s & f in repairmcb single pole, 240 volts, 6 to 32 ampere, rupturing capacity 10 ka, ‘b’ curve type complete all as specified and directed. make :legrand / hager / schneider elect 119 s & f in repairmcb single pole, 240 volts, 40 to 63 ampere, rupturing capacity 10 ka, ‘b’ curve type complete all as specified and directed. make :legrand / hager / schneider elect 120 earthing complete with gi earth plate electrode of size 60 x 60 x 0.6 cms burried directly in ground vertically at a depth of not less than 2.25 mtrs below normal ground level with top edge of the earth plate at a depth not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cms thick and packed layer of charcoal dust and common salt filling in alter nate layers etc and connected to and including gi earth striq size 25x4mm upto 7.5 mtr by means of bolts, nuts, checknuts and washers made out of galvanised iron and protected by light grade 15 mm dia 5 mtr long and connected to main control panel and gi pipe 20 mm medium grade as watering pipe including funnel, wire mesh, pcc pit made up of pcc 1:2:4 type c2 and rcc cover 40 mm thick with 8 mm bar 15 c / c including excavation and earth work all as specified in ssr part 1 2009. 121 m&l forroad cutting including excavation and gettingout, returing fittlinginspreading levelling and well rammingin layers, soling with broker builders or quarried stone, inter stices filled, 7.5 cm thick ( compacted thickness ) wbm ( water bound macadam ) with coarse aggregateretreived from road cutting consolidated to required gradientand camber, including applying evenly a priming / tack coat with bituminous primerand making surface even and getting our surplus soil complete all as specified and directed. 122 supply and fixing / laying galvanised pipe 50 mm bore medium grade fixed to pole with clamps nuts, bolts and washers or laid under road crossing or fixed to wall complete all as specified and directed. 123 supply and fix in replacement of security light fitting led 25 watt aluminum pressure dia cast housing with touched glass cover ip 66 protectionincludingsuitable sizeand accessories complete mounted including connection with 3 core pvc insulated overall sheathed flexible cable with muyltistranded copper conductor of size not less than 1.0 sq mm from celing rose to fitting terminal including taking down old cfl security light fittingall as specified and as directed. 124 s& f gi bracket light grade gi pipe 1.2 mtr length of suitable dia for fixing of street light fitting25 / 35 wattincluding connection all as specified and directed. 125 s&f mccb incomer distribution board double door vertical type made out of crca ms sheet surface with insulated material like polyester or with epoxy powder coating surface mounting tpn 4 way, 415 volts with copper bus bar rating 200 amps, dust and vermin proof suitable for incorporation of mccb and ip 43 ik 09protection with and incl 100 amp 36 ka 4 pole mccb with thermal magnetic setting and icu = ics = 100% ) complete all as specified. . ( note : the cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash / colour / distemper etc is included in quated rate ) 126 m & l for laying of lt cable of 1100 volt xlpe insulated and pvc sheathed of size 25 sqmm 4core with cable gland including taking down oldunserviceble cable complete all as specified and directed by engineer in charge.make havells, glostar & polycab. 127 excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc1.5 mtr in depthall as specified & directed. 128 returning, filling in, any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified& directed. 129 removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed. 130 supply, laying & fixing double wall corrugated ( dwc ) pipes made of high density polyethylene ( hdpe ) with all accessories i.e. all type of joints, sockets, elbows, bends and end cap etc. of size 75 mm outer dia and 61 mm inner dia complete all as specified and directed. make : telerex / tirupati or e in c approved make 131 taking down ceiling fan of any make & sweep size by disconnecting clips, lock nuts etc. from existing position of any height, keeping in safe costudy and hanging the same after cleaning andpainting of ceiling fan complete with synthetic enamel paint by spraying one coat and marking mes no. complete all as specified and directed by engr in charge. 132 supply & fixing in replacement ofamaze square / round recess mounteddown lighter12 watt including separate replaceable electronic driver celling cut out 106mm x 106mm height 33mm square shaped polycarbonate fixturecomplete all as specified and directed. 133 supply and fixing led luminaire 600 mm x 600 mm, 35 / 36 watt, 220 v ac recessed type with high efficiency pmma diffuser soft glare free light complete with driver, holders & led lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizecomplete. 134 supply & fixing in replacement ofamaze square / round recess mounteddown lighter15 watt including separate replaceable electronic driver celling cut out 106mm x 106mm height 33mm square shaped polycarbonate fixturecomplete all as specified and directed. 135 supply and fixing ofexhaust fan of sweep 230 mm complete with self closinglouvers, mounted in suitable opening arrangement and suitable for operation on 230 volts single phase, 50 hz, ac supplyand including two core pvc insulated, pvc sheathed copper conductor flexible cable 1.5 sqmm and making all necessary connection and fixed by using 4 nos 100 mm long 10 mm dia bolts, nuts and washers and grouted in wall in wall with cement1:3 completed all as specified and directed. make: havells / cg / orient.note: the cost of making hole in the existing wall and making good the disturbed surface of wall / ceiling etc as original i.e. brick work, plastering, white washing ect. is included in the quoated rate and no extra payment will be made to contractor in this effect. 136 single pole and neutral enclosure 32 a , 230 v with a two pin and earthplug and socket complete with one singlepole mcb 25 a complete all as specified and directed....

Department Of Civil Aviation - Punjab

34702877 bids are invited for earth work in excavation , filling available excavated earth , supplying and filling in plinth with sand , providing and laying in position cement concrete 1 1 3 , providing and laying in position cement concrete 1 4 8 , providing and fixing up to floor five level precast cement concrete hollow block , 12 mm cement plaster of mix 1 6 , providing and fixing to existing door frames 24 mm thick pvc door shutters , providing and laying vitrified tiles in floor with spacers 600 x 600 mm , providing and laying vitrified tiles in skirting 600 x 600 mm , grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix , finishing walls with water proofing cement paint , finishing walls with acrylic smooth exterior paint , wall painting with plastic emulsion paint , painting with synthetic enamel paint , repairs to plaster , providing and fixing brass curtain rods , providing and fixing curtains , taking out existing wooden door shutter, repair by cutting, painting etc. and refixing , providing and fixing aluminium sliding door bolts 250x16 mm , providing and fixing aluminium tower bolts 200x10 mm , providing and fixing aluminium handles 150mm , renewal of old putty of glass panes , supplying, stacking and spreading at site. good earth , providing and fixing aluminium work for doors, windows, ventilators and partitions. for fixed portion , providing and fixing aluminium work for doors, windows, ventilators and partitions for shutters , providing and fixing 12 mm thick prelaminated particle board , providing and fixing glazing in aluminium door, window with float glass panes of 4.0 mm thickness , providing and fixing aluminium hydraulic door closer , providing and fixing aluminium handles 200 mm , providing and fixing aluminium handles 125 mm , providing and fixing aluminium tower bolts 100 x 10 mm , providing and fixing chromium plated brass 100 mm mortice latch and lock , providing and fixing aluminium hanging floor door stopper , providing and fixing aluminium grill...

Military Engineer Services - Punjab

34417623 annual maintenance of jcos or md accn in candeth & malhotra enclaveunder age br i of ge n mamun 1 taking down chowkhats of frames n.exc 1.50 sqm with shutters ( without taking off shutters from the frames ) , removal from site complete all as specified and directed. 2 all as per srl item no 1, but exceeding 1.5 sqm and n.exc 4 sqm. 3 taking down shutters of any description exc 1 sqm but n exc 2 sqm each, removal from site complete all as specified and directed. 4 taking down shutter exc 1 sqm to 2 sqm and refixing in same opening safely, ( including minor repair ) complete all as specified and directed. 5 s&f box type steel windows and ventilators comprised of tubular frame and shutters made out of 1.25 mm thick m s sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter ( wire cloth and glass panes only shall be measured and paid seperately ) with side hung shutters with steel handle and steel peg stay dovetailed or welded including 2 nos tower bolts 150 mm long for each leaf and 10 mm square bar grills at spacing as shown on drg welded to fi frame work, including other fittings, hinges, handles, tarred hold fasts, pcc blocks etc all as shown on drg no cepz / td 354 / 09 sheet 1 / 3 to 3 / 3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 6 s&f pressed steel frame made out of ms sheet 1.25mm thick of size 125x60mm for doors / windows with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including filling of concrete 1:3:6 type c 0 ( 12.50 mm graded aggregate ) back of chowkhats and including two coats of synthentic enamel paint over shop coat of primer complete all as specified and sirected. 7 all as per item 6 but size 105x60 mm. 8 s&f 2nd class hard wood 35mm thick glazed and skeleton shutters, open rebated and prepared to receive glass or gauge etc ( divided into squares with plain chamfered or rounded , mitred and rebated sash bars, any numbers ) , edges of framing plain chamfered or rounded fitted with cut and mitered beads and fitted to chowkats for securing glass / gauge size of stiles rails and other parts as per clause 8.24 ( a ) of ssr part icomplete all as specified & directed. 9 s&f 35mm thick factory made plain framed panelled shutters of 2nd class hard wood two panel with lock rail and panel of 9mm thick bwp commercial ply. the size of rail and stile as per is 1003 ( part i ) kiln seasoned and chemically pressure treated factory made shutters wood is to be incorporated complete all as specified and directed. 10 m&l preparation of wood or wood based surfaces of any descriptionover 10 cm width or girth and applying two coats of synthetic enamelpaint over a coat of pink primer complete all as specified and directed. 11 m&l for 18 to 20 mm thick perlaminated pvc solid board with acrylic lamination not less than 0.50 mm thick ( one side decorative choice laminaate and other side balancing white ) having weight not less than 9 kg / sqm as in kitchen cabinet, cupboard with suitable 125 mm long fancy handle ( as per sample ) and pelmet box fixed with screws to pvc / timber frame work complete all as specified and directed. 12 s&f factory made wood grain solidpannel pvc door shutter 30mm thick ( style ) consisting of frame made out of ms tube s for top and bottom rails. ms frame shall be covered with heat moulded plain colour pvc c channel having a pvc sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour & as gap insert for top rail & bottom rail panelling of plain colour sheet to be fitted in ms frame welded / sealedto stiles & rails with suitable pvc sheet beadingand joined together with solvent cement , supplying & fixing in the frame at site as per specification & drawing compete all as specified and directed. 13 m&l soild pvc door frame wood grain colour coated of size 50mm x 95mm made out of 5mm wood grain colour pvc sheet reinforced with ms sqaure tube , supply and fixing in opening as per specification & drawing complete all as specified and directed. 14 m&l for repair to old steel window shutter not exc 1 sqm each including replacement of all hinges, handle, and necessary welding to shutter and chowkhat for making window in serviceable condition including two coats of synthetic enamel paint complete all as specified and directed. 15 all as per item 14 butexc 1 sqm and n exc 2.00 sqm each. 16 s&f for 100 mm long butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and as directed. 17 s&f for 100 mm long hasp staples, mild steel wirw type stove enamelled black including bolt to hinge plate and fixed with screws complete all as specified and as directed. 18 s&f aluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded setion or cast aluminium alloy and fixed 250 mm long complete all as specified and directed. 19 s&f anodised aluminium barral tower bolt extruded section 200 mm size complete all as specified and directed. 20 s&f anodised aluminium handle cast type 125 mm size complete all as specified anddirected. 21 hacking out old broken glass ( any thickness , size, quality, or description ) from wooden frame glazed with putty or fixed with beads, rubbish off the premises complete all as specified anddirected. 22 s&f frosted glass pin head type 3 mm thick ordinary quality and glazing with oil putty n.exc 0.5 sqm in each pane complete all as specified and directed. 23 all as per item no. 22 but plain 3mm thick sheet glass. 24 s&f mild steel 300mm, ordinary rat tail rod pattern springs including roller & roller plate including necessary welding complete all as specified and directed. 25 s&f in repairms helical aluminium door spring 150mm size fixed to steel framecomplete all as specified and directed. 26 s&f for stainless steel wire cloth 0.36 mmnominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks, or galvanized wire staples complete all as specified and directed. 27 all as per item no. 26 but s&f in repair. 28 taking up or down steel water tubing and connections including cleaning for refixing or removal to store for bore of pipe 15mm borecomplete all as specified and directed. 29 s&f 15mm bore tubes medium grade galvanized isi marked with all fittings short pieces and fixed complete to walls, floor, ceiling etc, complete all as specified and directed. 30 all as per srl item no 29, but fixing only 31 all as per item no 28 but 20mm bore. 32 all as per item no 29 but 20mm bore. 33 all as per srl item no 32, but fixing only 34 taking down eaves gutters and rainwater pipes 100 mm dia ( any size or pattern ) , including all fitting , head , shoes , bend, swan nacks etc., including cleaning or refixing or removal to store complete all as directed and directed. 35 s&f pvcb ( swr ) pipes 110mm bore, single socketd , in any length with rubber ring joints , in any length fixed to walls, complete all as specified and directed. 36 s&f pvc ( swr ) bend any radius 110mm dia borecomplete all as directed. 37 m&l cutting chases pinning in brick mas and making good to facing where required and pointing in cement and making good in cm 1:3 cutting n.exc. 10cm in girth complete all as specified and as directed. 38 m&l for ( 60 to 100 mm thick ) repair to rcc sunshades, chajjas, balconies, columns, bands, beams and similar rcc work at any position / height by dismantling loose / disintegrated portion, dubbing out with cement concrete 1:1½:3, using 6 to 12.50mm graded stone aggregate required shape and finish including provision of necessary formwork / supports etc ( upto double storey bldg ) , removing correded reinforcement , with and including providing ( duly welded ) new reinforcement as per existing or ( as directed ) required as per site condtion, rendering exposed surface with plaster 5mm thick in cm 1:3 mixed with wpc as per manufacturer instruction, applying two coats of exterior emulsion paint over a coat of primer complete all as specified and as directed. 39 m&l glazed ceramic coloured tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including bedding layeer of mortar 10mm thick in cm ( 1:4 ) , finished rough including dismantlingfloor, hearth or wall tiling including cement mortar bedding ( but not backing removing serviceable tiles to store and rubbish off the premises complete allas specified & directed. 40 all s per item 39 but non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqmbut not exceeding 0.18 sqmin floors, laid over 15mm thick screed bed cm 1:6. 41 m&l marble work 14 to 16mm thick ( table rubbed and polished ) in cooking plateformwindow cill etc in cement mortar including pointing in white cement ( 1:2 ) using marble dust with admixture of pigment to match set and jointed in neat cement slurry and pointed in coloured cement ( to match ) laid over 15mm thick screed bed in cm ( 1:6 ) including dismantling of existing marble work, bedding layer of mortar, rubbish off the premises all as specified and as directed. 42 all as per item no 41 but in vertical surface ( skirting / dado etc ) laid over bedding layer of mortar 10mm thick in cm ( 1:4 ) . 43 s&f in repair angular stop cock15mm bore dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 44 s&f in repairbib taps for 15 mm bore dia, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrulecomplete all as specified and directed. 45 all as per item 72 but long body 46 s&f in repair pillar tap 15 mm bore dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lette ed hot or cold with long screwed shanks and fly nuts, screwed for ironpipe and fixed complete all as specified and directed. 47 s&fin repairs vitreous china wash basin, white flat back, size 550 x 400 mm including waste pipe , brackets and cutting for and pinning in ends of brackets or errecting standwith waste coupling and 32 mm diawaste pipe complete all as specified and directed. 48 s&f in reapirtowel rail cp 24, dia 3 / 4 size complete all as specified and directed. 49 s&f in repair cp soap dish holder complete all as specified and directed. 50 s&f in repair 600 x 450 mm bevelled edge mirror of selected quality glass 5mm thick, mounted on 6 mm thick ac building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified. 51 s&f ci floor trap 75mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type b 1 with cp grating with or without hole for waste pipe complete all as specified and directed. 52 s&f in repair pvc flushing cistern 10 ltr capacity including pvc connection inlet and and outletconnections, brackets, pvc flush pipe with bend 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to wc complete all as specified and directed. 53 s&f vitreous china wash down water closet pan pedestal pattern, white ( excluding supply of flushing cistern and flush pipes, but including fixing thereof ) , including making connections to trap, and to flush pipe including plastec seat and cover ( as directed ) with stainless steel or aluminised hinging device and fixed in repair complete all as specified and directed. 54 s&f in repair 32mm dia pvc waste pipe complete all as specified and directed. 55 s&f in repair 20mm dia of pipe bass brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. 56 s&f in repair health foucet hand shower 8mm dia 1m long flexible hook and wall hook complete all as specified and directed. 57 s&f in repair vitreous china, squatting from pan orissa pattern white size 580mm x 440mm white with integral footrest including provisionof lean concrete bedding connection to drain out pipe and to flush pipe and to flush pipe anti syphonage pipe etc complete including making good to floor where required competeall as specified and directed. 58 s&f cover for plastic water closet seat, closed pattern with flat bottom & cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. 59 s&f pvc connections 15mm size with ptmt nuts of length 450mm complete all as specified and directed. 60 s&f in repair20mm dia mild steel fancy type dropery rod, wooden shade withpvc bracket and pvc fenial fixed over doors and windows with steel screws and pvc rawl plug / cleat complete all as specified and directed. 61 s&f sink with drainage board made of stainless steel 1 mm thick kitchen laboratory with plugs, washer and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx415mmx460mm bowl size 410 mm x330mmx160mm complete all as specified and directed. 62 s&f rotational moulded polyethlene water storage tanks of capacity 500 litres two layers ( cylindrical vertical with closed top ) , isi marked hoisted and fixed in position all as specified in ssr part i complete including 20mm dia ball brass valve high pressure with polythene float and dismantling of existingtank ( rcc or pvc ) of any capacity complete all as specified & directed. 63 s&f in repair 20mm size gun metal globe or gate valves with iron wheel head, screwed both endsfor iron pipe and fixedcast copper chromium plated fancy type alloy isi marked with crutch or butter fly handles screwed down screwed for iron pipe of 20mm bore complete all as specified and directed 64 s&f in repair pvc lidfor water tank of capacity 500 ltrcomplete all as specified and directed. 65 dismantling brick tile or terracing tiles single layer on s / s or d / s roof complete all as specified and directed. 66 m&l pcc 1:2:4 type b 0 ( using 12.5 mm graded stone aggregate ) padding as levelling course / padding using water proofing compound laid over existing roof , suface finished rough to recieve cement mortar including necessary formwork including demolition of existing concrete of any description and removal of debris out of the premises complete all as specified and as directed.note ; ( wpc shall be measured and paid seperately ) . 67 m&l forcement concrete ( 1:2:4 ) type b1 ( using 20 mm graded crushed stone aggregate ) as in repair to chajjas, roof projection, kerbs ( gola to joint with parapet etc ) and the like rounded or chamfered on edges including necessary form work complete all as specified and as directed. 68 m&l 20mm thick cement plaster in cement mortar 1:4 on concrete surface, surface finished even and smooth using wpc ( liquid ) as per manufacturer instruction or @ 0.200 ltr in 50 kg of cement complete all as specified and as directed 69 m&l for app modified roof treatment over existing non accessible rcc roof slab / chajjah / canopy / parapet wall ( to be executed through approved applicator of the membrane manufacturer ) with following specification etc complete all as specified and directed : ( a ) cleaning existing surface properly, applying oil bound bitumen primer @ 0.30 liter / sqm manufacture by the same agency as that of app with a density 0.87 0.89 kg per liter at 25 degree centigrade on prepared surface, laying not less than 3.0mm thick app modified water proofing membrane, weighing not less than 3.60 kg / sqm, reinforced with non woven polyster fiber weight not less than 160gsm / sqm using butane torch by torch application with 10cm side laps and 15cm end lap. ( b ) top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 kg / sqm as prescribed by manufacture of membrane. 70 taking down cement plaster on brick walls or stone walls any descrition etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed. 71 m&l for 15mm thick cement plaster in cm 1:4 ( in two layers i.e 1st layer 10mm, external layer 5mm thick ) on stone masonary or other than fair faces of brick work surfaces finishing the surfaces even and smooth without using extra cement. external layer of plaster shall be using wpc complete all as specified and directed. ( note: wpc shall be measured and paid seperately ) 72 m&l rendering 10mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar ( 1:6 ) finished even and fair without using extra cement all as specified and directed. 73 m&l rendering 5mm thick cement plaster on faces of concrete surfaces in cement mortar ( 1:3 ) as in ceiling finished even and fair without using extra cement all as specified and directed. 74 m&l preparation of new plastered surface of walls and applying wall care putty ( any thickness ) to obtain the surface even and smooth, applying two coats of oil emulsiondistemper complete all as specified & directed. 75 m&l preparation of new plastered surface of external wall surface applying two coat of cement base paint including curing complete over a coat ofalkali resistant priming paint complete all as specified & directed. 76 m&l three coats of white wash on newly plastered surface of walls including preparation of surfaces complete all as specified and directed. 77 m&l two coats of white wash on newly plastered surface of ceiling including preparation of surfaces complete all as specified and directed. 78 m&l for complete removal of existing treatment from walls, applying wall care putty ( any thickness ) to obtain the surface even and smooth, and applying two coats of distemper oil emulsion, white or tinted complete all as specified & directed. 79 m&l forpreparation of old plastered surfacesby scrapping down smoke roots, moulds salts and treading oil and greasy spotswith wire brush and applying one coat of white wash on wall complete all as specified & directed. 80 m&l forpreparation of old plastered surfacesby scrapping down smoke roots, moulds salts and treading oil and greasy spotswith wire brush and applying one coat of white wash on ceiling complete all as specified & directed. 81 m&l forpreparation of old plastered surfacesby scrapping down smoke roots, moulds salts and treading oil and greasy spotswith wire brush including removing all nails & washing with clean water down and applying one coat of oil bound distemper on wall , white or tinted complete all as specified & directed. 82 m&l prepration of old steel surfaces of anydescription, not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint , white or tinted complete all as specified and directed. 83 m&l prepration of old wooden surfaces of anydescription, not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint , white or tinted complete all as specified and directed. 84 dismantling of brick work built in cement mortar including all quoins, arches, pillars etc, rubbish off the premises complete all as specified and directed. 85 m&l for brick work with fly ash bricks ( old size bricks ) straight or curved on plan exc 6 mtr mean radius built in cm ( 1:6 ) complete all as spd and directed 86 all as per item 85 but using old servicable bricks. 87 demolition of cement concrete ( un reinforced ) in ground floor and paving n.exc 15 cm thick ( below or above ground level ) , removal of rubbish complete all as specified and directed. 88 m&l 75mm thick cement concrete type c 1, 1:3:6 ( using 20mm graded stone aggregate ) as in plinth protection, laid in slope finished even and fair including making joints at every 2.5 m and at corner, filled with bitumen 85 / 25 and sand in ratio 1:2 by weight complete all as specified and directed. 89 s&f in repair 100 mm bore ci bends ( any radius ) diminishing pieces or tapers ( larger bore measured ) complete all as specified and directed. 90 all as per item 89 but 75 mm bore ci bends 91 all as per item 89 but with ovel asses door 92 all as per item 90 but with ovel asses door 93 s&f in repair cast iron branch peices, single ( equal or unequal ) ordinary or inverted ( spigot or socket type ) , or with parrallel branches fitted with oval access doors of 100 mm bore diacomplete , isi marked complete all as specified & directed. 94 all as per item 93 but 75 mm bore. 95 s&f 100 mm bore cast iron ( sand cast ) soil waste and vent pipes isi marked in any length with or without ears fixed to walls with clamps and cement joints including dismantling complete all as specified and directed. 96 all as per item 95 but 75 mm bore. 97 all as per item 95 but 75 mm bore, laid in floor with cement joints. 98 all as per item 95 but 50 mm bore. 99 all as per item 95 but 100 mm bore, laid in floor with cement joints. 100 s&f in repair cast iron cowl for 50 mm dia complete all as specified and directed. 101 m&l for opening of air lock in gi pipe 15mm / 20mm by removing / taking down of gi pipe ( including flushing out sand / silt ) and refixing as same to obtain optimum water pressure complete all as specified and directed. 102 m&l for providing and injecting chemical emulsion for post constructional anti termite treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litre per linear meter including drilling and plugging of holes etc in apron / plinth protection complete all as specified in is code 6313 part ( 3 ) : 2001 and as directed by engr in charge. note: chlorphyriphos 20% ec or lindane 20% ec isi marked shall be used. 103 m&l for providing and injecting chemical emulsion for post constructional anti termite treatment of soil under existing floors using chemical emulsion @ one litre per hole 300 mm apart along the junction of floor and wall, along joints in floors including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floor complete all as specified in is code 6313 part ( 3 ) : 2001 and as directed by engr in charge.note: chlorphyriphos 20% ec or lindane 20% ec isi marked shall be used. 104 m&l 10 mm thick cement plaster in cm 1:3 on brick or concrete surface of sunken floor finished even and smooth using wpc liquid @ 0.200 ltr in 50 kg of cementor as per manufacturers instructions complete all as specified & directed. 105 m&l forbitumen blown any grade, applied hot, two coats to concrete / plastered surfaces @ 1.5 kg per sqm per coat and applying polythene film black, 50 micron complete for sunken floor slab duly embedded in side wall / covered fillet complete all as specified and directed. 106 supply only liquid water proofing compound. 107 m&l for 25 mm thick pcc type b 1, 1:2:4 ( using 20mm graded crushed stone aggregate ) as in sub floors for laying floor finish complete all as specified and directed. 108 m&l plain cement concrete 1:5:10 type e2 using 40mm graded stone aggregate as in sunken floors and complete all as specified and directed. 109 m&l for kitchen slab / shelves supported on wall / beams using reinforced cement concrete type b1 ( 1:2:4 ) using 20 mm aggregate ( max thickness of slab 100mm ) including necessary formwork and demolition of existing slab / shelves, removal of rubbish complete all as specified and as directed. 110 m&l tmt steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips compete all as specified and as directed. 111 deduct:total amount of schedul a section ii ( sch of credit ) rs 59325.00 ( to be deducted from schedule ‘a’ ( boq ) to arrive at the contract sum....

Military Engineer Services - Punjab

34304134 job work quotation for m and l for preparation of newly plastered surface and applying two coats of exteriar emulsion paint over one coat of primer...

Punjab And Sind Bank - Punjab

33295199 tender for furnishing of tables/counters of punjab and sind bank zonal ofice, ludhiana (pb) board / ply laminate 1mm th. door closer / floor spring glue for fixing commercial board / laminate glass mortice latch & lock vertical blinds tapestry/leather foam aluminium sections false ceiling synthetic enamel emulsion paint/plastic paint mcbs db’s switch & socket pipe (pvc) telephone cable wires cables fans mirror optics spot light & light fittings ...

Military Engineer Services - Punjab

33110337 job no sw177 provn of klp otm accn for army avn sqn at bathinda mil stn m and l for preparation of newly plastered surface and applying two coats of exterior emulsion paint over one coat of primer...

Military Engineer Services - Punjab

32853680 repair maintenance to misc items of work roof treatment with tilings repair to window shutter etc for domestic depot area at unchibassi under ge ( s ) pathankot 1 demolition of brick work / stone masonrybuilt in cement mortar including all quoins, arches, pillars etc complete all as specified. 2 m & l for brick work with sub class ‘b’ ( old size ) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified. 3 all as per srl item no. 02 above, but except bricks. 4 brick work with sub class ‘b’ bricks, straight or curved on plan any radius in half brick thick wall with old size bricks built in cement mortar 1:4 complete all as specified. 5 taking down cement plaster of any description including raking outjoints, hacking for key, scrubbing down with water etc complete all as specified and directed. 6 m&l for rendering 15mm thick in cm 1:4 using liquid water proofing compound on brick work or concrete surfaces on wall, surfaces finished even and smooth using extra cement complete all as specified and directed. ( note : wpc shall be measured and paid separately under respective item ) . 7 m&l for rendering 10 mm thick in cement and sand mortar 1:6 on other than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement complete all as specified and directed. 8 m&l for rendering 10 mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling / top and sides of chajjas / facia of roof projection incl necessary formwork including finishing the surface even and smooth without using extra cement complete all as specified and directed. 9 supply only polymer liquid water proofing compound. 10 m&l for preparation of newly plastered / prepared surfaces of walls and applying three coats of white wash complete all as specified and directed. 11 all as per srl item no. 10 above, but on ceiling 12 m&l for preparation of newly plastered / prepared surfaces of walls and applying two coats of oil bound distemper over a coat of primer to match the shade as per existing colour scheme / pattern complete all as specified and directed. 13 m&l for preparation of newly plastered / prepared surfaces of walls and applying two coats of cement base paint over a coat of primer to match the shade as per existing colour scheme / pattern complete all as specified and directed. 14 m&l for preparation of newly plastered / prepared surfaces of walls and applying two coats of exterior acrylic emulsion paint over a coat of primer to match the shade as per existing colour scheme / pattern complete all as specified and directed. 15 preparation of existing surfaces incl washing, rubbing down and stopping of painted surfaces of walls and applying one coat of white wash complete all as specified. 16 all as per srl item no. 15 above, but on ceiling 17 m&l for preparation of existing surfaces incl washing, rubbing down and stopping of distempered and painted surface of walls and applying one coat of oil bound distemper to match the shade as per existing colour scheme / pattern complete all as specified and directed. 18 m&l for preparation of existing surfaces incl washing, rubbing down and stopping of painted surface of walls and applying one coat of cement base paint to match the shade as per existing colour scheme / pattern complete all as specified and directed. 19 m&l for preparation of existing surfaces incl washing, rubbing down and stopping of painted surface of walls and applying one coat of exterior acrylic emulsion paint to match the shade as per existing colour scheme / pattern complete all as specified and directed. 20 demolition of cement concrete ( un reinforced ) of any description and in any position not otherwise specifically provided for complete all as specified and directed. 21 demolition of cement concrete ( reinforced ) of any description and in any position not otherwise specifically provided for complete all as specified and directed. ( reinforcement cut as required to facilitate demolition ) 22 m&l for 75mm thick pcc 1:4:8, type d 2 ( using 40mm graded stone aggregates ) as in sub base for pavement, path etc, complete all as specified and directed. 23 m & l for 50mm thick pcc ( 1:3:6 ) type c 2 using 40mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified. 24 m & l for 25 mm thick pcc 1:2:4 type b 0, using 12.50 mm graded stone aggregate, including finishing surface of concrete topping even and rough complete all as specified. 25 m & l for 40mm thick pcc ( 1:2:4 ) type b 1 ( using 20mm graded stone aggregate ) as in floors and similar works, including finishing the surface of concrete topping even & smooth without using extra cement complete all as specified and directed. 26 dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) and removing rubbish off premises complete all as specified. 27 s & f for non skid coloured ceramic tiles 7 to 8 mm thick ( square / rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade oftiles over and including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified. 28 s & f for glazed coloured ceramic tile 450 x 300 x 7mm thick ( coloured ) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4 complete all as specified. 29 m & l for non skid ceramic joint free tiles 7 to 8 mm thick coloured / wooden finish ( square / rectangular ) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:6, complete all as specified. 30 m & l for non skid ceramic joint free tiles 7 to 8 mm thick coloured / wooden finish ( square / rectangular ) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in skirting / dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4 complete all as specified.. 31 m & l for 18mm thick udaypur green marble machine cut in any position bull nosed on front face, laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 15 mm thick screed bed in cement and sand mortar 1:4 complete all as specified and directed. 32 m & l for 18mm thick granite ( of any type ) machine cut in any position bull nosed on front face, laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing over and including 15 mm thick screed bed in cement and sand mortar 1:4 complete all as specified and directed. 33 m & l for rubbing and polishing of existing kota stone flooring, steps and skirting complete all as specified and directed. 34 m & l for coloured chequered cement concrete tiles 30cm x 30cm x 20 22mm thick with grey cement and pigment, set, jointed and pointed in white or coloured cement to match the shade of tiles over and including 20 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and directed. 35 m & l for machine pressed precast concrete interlocking paver block incl 6 8 mm thick white cement layer coated with epoxy coating ( red / yellow ) built with grey cement and pigment of 60mm thickness, any shape and size confirming to is incl 50mm thick sand filling under paver, properly levelled etc complete all as specified and directed. 36 all as per srl item no. 35 above, but except tile / paver block. 37 dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings complete all as specified and directed. 38 m & l for pre painted galvalume aluminum zinc coating gi based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering, fixed with self tapping screws etc complete all as specified. 39 m & l for pre painted galvalume aluminum zinc coating gi based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering, fixed with self tapping screws etc complete all as specified. 40 dismantling of plain or corrugated asbestos sheeting, any gauge, thickness, including nainital or similar pattern roof coverings complete all as specified and directed. 41 m & l for 6mm thick asbestos cement, corrugated or semi corrugated sheets in roofs, walls etc fixed with l type or j type or cranked hook bolts etc complete all as specified. 42 all as per srl item no 41 above but except sheets. 43 m&l for asbestos cement two piece adjustable plain wing ridge 6mm thickfixed with l type or j type or cranked hook bolts complete all as specified and directed. 44 dismantling of wall and ceiling boards ( fibre, pulp, insulation, etc ) or insulation boards / slabs / blankets, any thickness, including cover fillets complete all as specified and directed. 45 s&f gi snap grid frame work ( grid size 60x60cm ) for false ceiling with powder coated gi angle of size 25x25mm, main runner t of size 25x40mm secondary runner t size 25x30mm suspended with 3mm gi wire with butterfly clips for levelling complete all as specified and directed. 46 m&l for false ceiling of 9.5mm thick gypsum tiles ( 600x600mm ) laminated with pvc film on the face side & metalised polyester film on the back side with all four edges sealed with pvc film ( shade either plain white or crack ) complete all as specified and directed. 47 m&l for non asbestos 4mm thick e boards of size 60x60cm laid in gi grid for false ceiling purpose complete all as specified and directed. 48 dismantling of bricks ( laid flat or on edge ) or brick tiles in floors, etc. ( each layer ) laid, bedded and pointed in any mortar complete all as specified and directed. 49 roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brusing neat cement slurry with 3.00kg per sqm all as spd & directed. 50 m & l for pcc ( 1:2:4 ) type b 1 using 20 mm graded crushed stone aggregate on roof slab including finishing the top surface even & smooth without using extra cement complete all as specified and directed. 51 m & l for rendering 10 mm thick in cm 1:3 on flat roof surface mixed with liquid water proofing admixture as per manufacturer instructions when concrete surface is green, finished even and smooth without using extra cement all as specified. ( note : wpc shall be measured and paid separetly ) . 52 app modified roof treatment over existing accessible / non accessible rcc roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc including dismantling existing water proofing treatment of any description complete all as specified and directed : ( a ) cleaning existing surface properly. ( b ) applying oil bound bitumen primer @ 0.30 litre / sqm manufacture by the same agency as that of app with adensity of 0.87 0.89 kg per litre at 25 degree centigrade on prepared surface. ( c ) laying not less than 3mm thick app modified water proofing membrane weighing not less than 3.60 kg / sqm reinforced with non woven polyster fiber of weight not less than 160 gsm / sqm using butane torch by torch application with 10 cm side laps and 15 cm end lap. laying of membrane , physical property of membrane shall be as under : ( i ) membrane weight not less than 3.60 kg / sqm. ( ii ) non woven polyester weight not less than 160 gsm / sqm. ( iii ) softening point of membrane not less than 150 degree celcius. ( iv ) joint tensile strength longitudinal not less than 650 sqcm and transverse not less than 450 sqcm at 230 degree celcius. ( v ) tear strength longitudinal not less than 300 n and transverse not less than 250 n. ( vi ) elongation and reinforcement not less than 30%. ( vii ) impermeability under water pressure not less than 3 kg / sqcm. ( d ) app membrane shall be laid using butane torch by torch application with minimum 10 cm side overlap and 15 cms end lap. 53 m & l for cement concrete tiles 30cm x 30cm x 20 22mm thick with grey cement and no pigment, machine pressed, set, jointed and pointed in white or coloured cement to match the shade of tiles over and including 20 mm thick screed bed in cement and sand mortar 1:6, complete all as specified and directed. 54 m & l for 40mm thick brick tiles laid on 20mm thick screed bed in cement mortar 1:6 and joints grouted flush in cement mortar ( 1:3 ) even and levelled, complete all as specified and directed. 55 all as per srl item no. 54 above, but except tile. 56 taking down chowkhats or frameswith shutters ( without taking off shutters from the frames ) of size n. exc 1.5 sqm each and removing from site complete all as specified and directed. 57 all as per srl item no. 56 above, but area exceeding 1.5 sqm and not exceeding 4.00 sqm each, complete all as specified and directed. 58 taking down shutters of any description, area not exceeding 1.00 sqm each, complete all as specified and directed. 59 taking down shutters of any description, area exceeding 1.00 sqm and not exceeding 2.00 sqm each, complete all as specified and directed. 60 s & f for pressed steel frames of size 105 x 60 mm for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, incl filling of pcc 1:3:6 type c 1 using 12.5mm graded stone aggregate as in frames / hold fast blocks complete all as specified and directed. 61 s & f for pressed steel frames of size 125 x 60 mm for doors with one or more rebates incl necessary fixing lugs, hinges, lock strike plate, incl filling of pcc 1:3:6 type c 1 using 12.5mm graded stone aggregate as in frames / hold fast blocks complete all as specified and directed. 62 s & f for solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with m.s. square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed. 63 s & f for factory made solid panel pvc door shutter 30 mm thick both side prelaminated with wood grain / coloured paint ( style ) consisting of frame made out of m.s. tubes for top & bottom rails complete all as specified and directed. 64 s & f for factory made 35 mm thick, 2nd class hardwood plain framed, panelled shutter ( two panel ) with lock rail and panel of 9 mm b.w.p. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. the size of rail and stile as per is : 1003 ( part i ) , kiln seasoned and chemically pressure treated complete all as specified and directed. 65 s & f for factory made 35 mm thick, 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. ( without sash bars ) , edges offraming plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc, supplied and fitted to chowkats complete all as specified and directed. 66 s & f for factory made 20 mm thick flush shutters, solid core construction and plywood face panels, commercial type on both sides complete all as specified and directed. 67 s & f for framed work such as grills, gratings, etc.. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors, door shutters; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work, complete all as specified and directed. 68 s & f for z section steel windows / ventilators with side hung shutters including projecting type hinges with 2 nos steel handle, 2 nos tower bolt and 01 no steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and directed. 69 all as per srl item no 68 above but without glazing bars. 70 painting to newly surfaces of wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, with two coat of synthetic enamel paint over a coat of pink primer complete all as specified. 71 preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and priming with red oxide zinc chrome and painting with two coats of synthetic enamel paint complete all as specified and directed. 72 m&l for painting to old painted surfaces of wood or wood basedsurfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, with one coat of synthetic enamel paint to match the shade as per existing colour scheme / pattern complete all as specified and directed. 73 m&l for preparation ofold painted steel surfaces of any descriptionexc 10 cm width or girth and painting with one coat of synthetic enamel paint to match the shade as per existing colour scheme / pattern complete all as specified and directed. 74 taking down steel window / gate / door shutter of any description for repair purpose such as welding etc, incl replacement of ms tower bolt / handle / peg stay to make the shutter serviceable and refixed in same position after complete repair, complete all as specified and directed. 75 taking down steel rolling shutters of any description area not exc 10 sqm complete all as specified and directed. 76 s&f steel rolling shutters, 1.25mm thick lath without ball bearing in, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position push pull or manual type complete all as specified and directed. 77 supply only safety lever locks mild steel with 4 levers for rolling shutters, complete all as specified and directed. 78 supply only ball bearing for rolling shutters, complete all as specified and directed. 79 taking down steel rolling shutter of any description for over hauling repairs / replacement of lath strips, guide channel, hood cover, lock plate bracket plate, helical spring, ball bearing etc and refixing after complete repair, incl greasing oiling etc for smooth functioning in position of area of rolling shutter n exc 10 sqm, complete all as specified and directed. 80 taking down sliding steel door of any description for over hauling repairs, replacement of rolling wheel, ball bearing , repairing rolling track etc and refixing after complete repair, incl greasing oiling etc for smooth functioning in position of area of shutter n exc 10 sqm, complete all as specified and directed. 81 supply only roller wheel, axle, nut and bolt with locking pin etc. for sliding steel door complete all as specified and directed. 82 s & f for butt hinges, 100 mm long medium weight, complete all as specified. 83 s & f for 300mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixedwith hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section complete all as specified. 84 s & f for 150mm long, aluminium anodised, barrel tower bolts, of extruded section isi marked complete all as specified. 85 s & f for aluminium handles cast type anodised of size 125mm long isi markedcomplete all as specified & directed. 86 s & f for continous ( piano ) type hinges mild steel bright finish or electrogalvanised with wide of flaps 40mm, complete all as specified & directed. 87 s & f for 150 mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate, isi marked complete all as specified. 88 s & f for floor door stopper of aluminium alloy body, two legged not less than 50mmcomplete all as specified & directed. 89 s & f for 40 mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified. 90 hasp and staple of size 100 mm, safety type, aluminium anodised with hinge pin incl bolt to hinge plate and fixed with screw complete all as specified. 91 hacking out old broken glass ( any thickness, size, quality or description ) from metal frames including punching or drilling out old glazing pins / spring clips and providing and fixing new ones glazed with oil putty fixed with beads or in wooden shutters complete all as specified and as directed. 92 s & f for 03 mm thick sheet glass, ordinary quality and glazing with oil putty / wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified. 93 s & f for 03 mm thick figured ( frosted ) glass, ordinary quality and glazing with oil putty / wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified. 94 galvanized mild steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified. 95 all as per the description of item no.94 above but fixed in repair. 96 m & l for ball catcher with proper magnetic effect fixed with shutter complete all as specified and directed. 97 s&f 20 mm bore pvc coated ms curtain rod, length of one rod not more than 1.5 metre including a pair of brackets and knobs with each length / piece, fixed on doors and windows opening for hanging curtains complete all as specified and directed. 98 s & f rotational moulded polyethlene water storage tanks of capacity 500 litres three layers ( cylindrical vertical with closed top ) hoisted and fixed in position all as specified in ssr part i including dismantling of existing pvc tank of any capacity complete all as specified & directed. 99 all as per item no 98 above but 1000 litres capacity. 100 s & f 20mm dia for ball valves high pressure of ptmt with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed, complete all as specified and directed. 101 mild steel tmt bars 10 mm dia and over, quality conforming to grade 415 mpa cut to length , bent to shape required including cranking , bending and binding with mild steel wire ( annealed ) not less than 0.9mm dia complete all as specified and directed. 102 providing cement concrete type b 1, 1:2:4 ( 20 mm graded crushed stone aggregate ) as in landings, parapet walls, facia, cover slabs upon drainage system incl necessary form work etc, complete all as specified and directed. 103 pcc ( 1:2:4 ) type b 1 using 20mm graded crushed stone aggregate as in benching, coping & hanuching etc complete all as specified and directed. 104 m&l for cement concrete 1:3:6, type c 1 ( using 20mm graded crushed stone aggregate ) as in surface channels and drains complete all as specified and directed. 105 extra for forming fair faces ( finished ) drain of channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitered stopped end etc complete all as specified and directed. 106 providing reinforced cement concrete type b 1, 1:2:4 ( 20 mm graded crushed stone aggregate ) as in slabs supported on walls, landings, balconies, canopies, deck slabs and in shelves and the like incl necessary form work etc, complete all as specified and directed. 107 note: in case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account....

Military Engineer Services - Punjab

32507251 jobwork quotation for m and l for preparation of newly plastered surface and applying two coats of exteriar emulsion paint over one coat of primer...

Department Of Defence - Punjab

32447563 bids are invited for double coat of synthetic enamel paint over one coat of primer on gi corrugated sheet , two coats of asian apex,berger,nerolac or equivalent paint to runway controller huts and toilet at both ends of runway during the flying ,water emulsion paint on runway tail area during the flyingoperation total quantity : 3300...

Military Engineer Services - Punjab

32026582 provn of standby arrangement and connected items for sewage plant no 2 and 3 under ge ( west ) ferozepur cantt 1. power transformers 132 / 66 / 33 / 22kv 2. distribution transformers 11 kv above 500 kva capacity 3. distribution transformers upto 500 kva capacity 4. power & distribution transformers upto 10 mva & upto 33 kva 5. chemical earthing 6. star rated energy efficient step down transformers upto 200 kva capacity ( 4 / 5 star rating only to be used ) 7. ht switch gear 132 / 33 kv & 66 kv, vcb ( out door / indoor ) / ct & pt 8. ht switch gear 33 / 66 kv, sf6 ( out door / indoor ) 9. ht switch gear 11 kv, vcb ( indoor / out door ) , ht ring main unit, sf6 / vacuum, 11 kv / ct & pt 10. ht switch gear protection relays ( electromechanical / numerical ) octagonal / high mast poles 11. package / unified substation 12. lt / ht cable joints heat shrinkable / cold shrinkable / push on type 13. gang operated switch device 14. lightening arrestor 15. ht / lt pcc poles 16. ct & pt, 11 & 33 kv 17. ht xlpe cables 132 / 66 / 33 kv & 11 kv 18. ht / lt steel tubular swaged poles 19. steel tubular decorative pole octagonal / high mast light and poles20. lt panels / apfc panels / ac control panels / pump house panels for ss having capacity 1000 kva and above lt panels / apfc panels / ac control panels / pump house having capacity below 1000 kva 21. high voltage insulating rubber mat 22. lt air circuit breakers 23. mccb’s 24. mcb / elcb / rccb / rocb / isolators / mcb dist boards 25. power contactors 26. voltmeter / ammeter / frequency meter / pf meter ( analog type ) 27. voltmeter / ammeter / frequency meter / pf meter ( electronic type / digital type ) 28. lt cables, 1100 volts, xlpe 29. pcc cable covers 30. change over switches 31. smart / tamper proof energy meters 32. voltage stabilizers upto 25 kva 33. voltage stabilizers above 25 kva ( servo controlled ) 34. ups ( off line & on line 35. dg sets ( i ) engine ( ii ) alternator 36. dg set integrator 37. lt capacitor banks 38. ht capacitor banks 39. pvc rigid conduit 40. pvc conduit pipe / gi conduit pipe, all accessories 41. ms conduit / erw conduit pipe42. pvc copper wires 650 / 1100 volts 43. pvc wires & cable upto 650 / 1100 volts 44. pt switch / sockets / ceiling roses / fan regulators 45. laminated sheet cover 46. modular switches / sockets / fan regulators 47. street light fittings & accessories– hpsv ( 70 / 150 / 250 / 400 ) , hpmv– ( 80 / 125 / 250 / 400 ) / metal halide 48. tube light / street light fittings 49. flood light fittings 50. acsr conductor / over head conductor 51. box type decorative light fittings 52. cfl fittings 53. cfl lamps 54. led lamps 55. sk fittings 56. ceiling fans / exhaust fans / wall mounted fans / air circulators ( only 5 star bee rating fans shall be provided ) 57. water heaters ( only 5 star bee rating water heaters shall be provided ) 58. bus bar trunking systems59. battery charger 60. lead acid batteries 61. led light fittings 62. flame proof switches / sockets / db’s 63. flame proof light / fittings 64. flame proof exhaust fans / pedestal fans / flame proof ac 65. solar street light fittings 66. street light timers 67. aviation obstruction light 68. transformer oil 69. integrated solar light ( led based ) 70. earthing system, lightening protection system, surge protection devices 71. copper clad steel conductor 72. cable junction boxes, circuit breaker boxes, dc rated junction boxes 73. push button stations 74. indoor / outdoor luminaire incl street light & garden light 75. overhead conductor 76. gi pipes / ms pipes 77. hdpe / upvc / ppr pipes 78. ci pipes 79. di pipes80. sluice valves / return valves / release valves 81. butterfly valve / check valves 82. gun metal globe valve 83. gi fittings 84. pump sets mono block 85. centrifugal pumps 86. submersible pumps 87. non clog sewage pumps 88. vertical turbine pumps 89. dosing pump / bleaching dozer 90. motor starters 91. electric motor 92. single phase preventors / phase sequence corrector 93. lifts / elevators 94. solar water heating works b ) air conditioning items 1. window type / split type air conditioners ( only 5 star rating ac’s shall provided ) 2. water coolers 3. refrigerator 4. deep freezer 5. cassette type ac 6. pillar type ac7. ductable ac 8. air curtain 9. fire damper 10. aluminium extruded / aluminium grill / diffuser 11. desert coolers 12. chillers / chilling units 13. air handling unit, cooling coil for ahu 14. cooling towers 15. fractional hp motors 16. variable frequency drivers ( vfd ) 17. pot / y strainer 18. pressure gauge / dial type thermometers 19. insulation ( fibre glass ) 20. insulation ( expanded polyethylene ) 21. insulation ( cross polyethylene foam ) 22. insulation ( nitrile ruber ) 23. tf thermocol for pipe insulation 24. controls ( 3 way valves ) / thermostats 25. extruded aluminium grills / diffusers / fire dampers 26. copper refrigerant piping 27. gi sheets for ducting 28. actuator 29. centrifugal fans ( ahu’s ) 30. strip heaters 31. humidistat / thermostate 32. air filter / hepa filter 33. factory built ducts 34. flexible connector 35. hot water generator 36. water treatment plant 37. duct flange 38. expansion valve 39. flow switch 40. automatic air vent 41. 3 way modulating valve 42. room thermostat / ahu thermostat 43. hp / lp cutouts / controls 44. air washers 45. propeller fans 46. butterfly valve c ) fire detection, fire alarm fire hydrant rrl hose pipe fire panel hooter / siren manual call bell point smoke / heat / ionisation detector addressable & non addressable7. water sprinkler head 8. fire extinguisher all type 9. fire fighting equipment’s 10. accessories 11. automatic fire detection & suppression system1. chloro pyriphos emulsifiable concentrate ( 20 ec ) 2. pressed steel door frames / chowkhats for doors / cupboards and windows frames 3. steel windows / vents4. rolling shutters & rolling grills 5. welded wire mesh / fabric 6. factory made panelled door shutters 7. factory made flush door shutters 8. pvc door frame / shutters 9. upvc windows / doors 10. iron mongery 11. standard mortice lock 12. hydraulic door closer 13. anodised aluminium doors / windows / frames / partitions 14. aluminium wooden doors and windows fittings 15. aluminium section16. aluminium sheets 17. aluminium composite panels 18. particle board ( veneered & unveneered laminated ) 19. plywood for general purposes 20. decorative laminates 21. fibre board ( medium density ) 22. pre fab panel boards / wall lining ceiling tiles 23. plain & pre laminated mdf & hdf boards 24. galvanised steel sheets & colours coated galvanised steel sheets 25. polycarbonate sheets 26. galvalume sheets 27. ac sheets / ac boards ( corrugated, semi corrugated ) 28. gypsum board 29. pvc tiles / sheet 30. glass mosaic tiles 31. terrazzo tiles / ppc tiles / ppc chequered tiles 32. interlocking tiles / exterior tiles / paver blocks 33. decorative textures / coatings 34. exposed brick façade35. glazed earthen ware tiles 36. glazed ceramic / non skid wall / floor tiles 37. vitrified tiles ( normal / anti skid ) 38. hdpe storage water tanks 39. sanitary appliances / fittings ( chinaware ) 40. water closet seats and cover ( solid bakelite ) thermostat moulded toilet seat cover 41. pvc flushing cisterns 42. stainless steel kitchen sink with or without draining board, plate rack 43. ss wash basin / wcs / stainless steel towel rail / towel rack / towel ring / soap dish / tph 44. ball valves ( horizontal plunger type ) 45. shower roses chromium plated ( shivel type ) 46. bath room fancy fittings 47. cp brass bathroom fittings and accessories 48. brass valve isi 49. bib taps and stop cock ( cp ) fancy fittings 50. ready made bathroom cabinets 51. salt galzed stone ware pipes / glazed stone ware pipes52. concrete hume pipes 53. ac pipes 54. pvc rain water pipe / sewage pipes 55. gi pipe / fittings 56. ci pipes fittings ( for sewerage / rainwater ) 57. soil waste pipe fittings / steel manhole cover 58. ppr pipes 59. hdfe pipes / snr pipes ( water / sewage ) 60. sand cast iron spigot & socket soil waste, vent pipes & fittings 61. cement based paints 62. dry distemper / oil bound distemper / plastic emulsion / exterior emulsion / silicon paints & coating 63. plastic emulsion paint 64. paint exterior 65. synthetic enamel paint 66. false ceiling tiles / board ( gypsum board / pop / mineral fibre ) 67. glass reinforced gypsum ( grg ) ceiling tiles68. drapery rods vista levalor 69. mirror looking saint gobain, glass 70. false ceiling / metal false ceiling gypboard, anchor, 71. ptmt fitting prayag, 72. wc seat cover isi marked isi marked specifications 73. frp door / frame shutter selected 74. rolled frames gi section windows ( pre painted / colour coated ) ashish 75. pvc wall paneling hr doors, ( make ecocell ) , 76. ms pipes apl appolo, 77. window blinds wintree ser no company name ( e ) cement...

Kendriya Vidyalaya Sangathan - Punjab

30830120 bids are invited for cement paint (q3) , putty is:419 (q3) , gypsum building plaster excluding premixed is:2547 (q3) , plastic emulsion paint is:15489 (q3) , enamel, synthetic, exterior: (a) undercoating (b) finishing paint is:2932 (q3) , washabledistemper is:428 (q3) total quantity : 414...

Power Grid Corporation Of India Limited - Punjab

30780228 bids are invited for plastic emulsion paint is:15489 (q3) , putty is:419 (q3) , enamel, synthetic, exterior: (a) under coating (b) finishingpaint is:2932 (q3) , paint brushes (q3) , cement paint (q3) total quantity : 1156...

Ministry Of Power - Punjab

29026329 bids are invited for enamel, synthetic, exterior: (a) under coating (b) finishing paint is:2932 , plastic emulsion paint is:15489 total quantity : 342...

Indian Bank - Punjab

28247510 tender for the furnishing & electrical works in indian bank at moga a) board / ply b) laminate c) door closer / floor spring d) drawer & keyboard, slide rails e) glue for fixing commercial board / laminate f) glass g) mortice latch & lock h) vertical blinds i) tapestry/leather foam j) aluminium sections k) false ceiling l) synthetic enamel m) emulsion paint/plastic paint a) sfu/mccb/ change over switch/db b) voltmeter/ampere meter c) armored unarmored cable d) pvc insulated wires e) telephone cable data cables & i.o’s g) modular switch / socket / call bell h) light fittings & lamps ceiling fan/wall bracket fan/exhaust polycab /finolex/havells. finolex/delton/havells. lucent/d link/cat vi. havells/legrand. philips/crompton/wipro/havells. crompton/orient/khaitan/bajaj. asian, nerolac, ici, berger asian, nerolac, ici , berger specifications / brands / make of items for electrical work to be used. l&t/ mds/ legrand/havells. ae/l&t. gloster/ cci/polycab. triveni, modi float, saint gobain, asahi. godrej, harrison. vista levelor / mac / neha. harmony, vimal, bhor or as approved jindal/mahavir/hindalco india gypsum marked “gypsteel” luxas / burma / unity / wood queen make (ripsa boards)conforming to isi standards. merino, century, greenlam: 1mm th. everite, doorking, sandhu, nitco. earl bihari, ebco (telescopic) fevicol (pidilite)...

Military Engineer Services - Punjab

27412555 purchase of stores against certain items of ca no ceafu 10 / 18 19 provn / demolition / addn / altn to deficient living in accn at af station pathankot , ( a ) s& f stainless steel railing complete all as specified and directed fixed in position complete . ref drg no cweaf / j / 20 / 2018 sheet no 5 / 12 . note : the rate quoted by the firm shall be inclusive of gst and all other service charges . , ( b ) m&l applying two coats of acrylic exterior emulsion paint min four colours as approved of any shade / colour in camoflage pattern over a coat of primer including preparation of newly plastered surfaces as per manufacture instructions complete all as specified and as directed . note : the rate quoted by the firm shall be inclusive of gst and all other service charges ....

Military Engineer Services - Punjab

27294144 purchase of stores against ca no ceafu 10/18 19 provn/demolition/addn/altn to deficient living in accn at af station pathankot , ( a ) s& f stainless railing as per drawing all as specified and directed fixed in position complete . ref drg no cweaf/j/20/2018 sheet no 5/12 . qty 122 . 46 rm ( b ) m&l applying two coats of acrylic exterior emulsion paint min four colours as approved of any shade/colour in camoflage pattern over a coat of primer including preparation of newly plastered surfaces as per manufacture instructions complete all as specified and as direced . qty 1856 . 26 sqm note : the rate quoted by the firm shall be inclusive of gst and all other service charges . ...

Military Engineer Services - Punjab

25614203 certain sanctioned work for age b / r and age e / m at nams 2 surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed. 3 m&l for rough excavation not exceeding 1.5 m deep and getting out in soft / loose soil complete all as spd and directed. 4 excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation, etc., and getting out in soft / loose soil complete all as specified and directed. 5 excavating post holes or similar holes, each not exceeding 0.5 cum, getting out in soft / loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n.exc 50m & making good surface 6 m&l for returning, filling in, including spreading, levelling, watering and well ramming in layers under floors or trenches complete all as specified and directed.complete all as spd 7 m&l for removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 8 m&l hardcore of gauge not exc 63mm broken stone or boulders but not exc 100mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rolled / rammed to a true surface for levelling the surfaces 9 m & l reinforced cement concrete type a1 1:1.5:3 ( using 20 mm graded stone aggregate ) in foundations including rafts, footings and mass concrete complete all as specified and directed. 10 m & l for pcc 1:2:4 type b 2 ( using 12.5 mm graded stone aggregate ) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement , rubbish off the primises complete all as specified and as directed by engg in charge. 11 m&l for cement concrete , type c1 1:3:6 ( using 40 mm graded aggregate ) as in foundation filling and mass concrete complete all as specified and directed. 12 m&l for hard core of ( broken bricks ) of guage n.exc 63mm deposited spread and levelled in layer n.exc 15cm thick watered and rolled / rammed to a true surface complete all as specified and directed. 13 m & l for plain cement concrete type d2 1:4:8 ( using 40 mm graded granite stone aggregate ) in foundations, filling and mass concrete complete all as specified and directed. 14 m&l pcc 1:2:4 type b1 ( using 20 mm graded stonr aggregete ) as in coping, benching etc complete all as specified and directed. 15 supply only integral water proofing compound. 16 m&l for brick work with subclass ‘b’ bricks, straight or curved on plan exc 6m mean radius, built in cm 1:6 complete all as specified and directed. 17 m&l for brick work with locally available subclass ‘b’ old size bricks, straight or curved on plan to any radius in half brick thick walls built in cm 1:6 complete all as specified and directed by engg in charge. 18 material and labour for 15mm thick cement plaster in cm 1:4 on fair faces of brick work and finishing the surface even and smooth ( without using extra cement ) etc. complete all as specified and directed. 19 m&l for newly plastered wall surfaces and applying two coats of exterior weather proof emulsion paint over one coat alkali resistant primer complete all as specified and directed. 20 m & l for 15 17mm thick kota stone slab as in treads, risers and flooring etc. laid over 15 mm thick screed bed or bedding layers in cm 1:6 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and mirror polished polishing types complete all as specified and directed. 21 s & f mild steel rag or lewis bolts of 20 mm dia, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised and exc. 30 mm long complete all as specified and directed. 22 s & f steel work in tubular trusses and tubular posts including special shaped washers, etc., complete using but welded tubes confirming to is 1161 1979 graded st 240 complete all as specified and directed. 23 s & f rolled mild steel plates ( plain or chequered ) channels, square cut or notched, forming holes, without any attachment confirming to fe 410 w ( gde e 250 ) quality a, complete all as specified and directed. 24 m&l two coats of synthetic enamel paint over a coat of red oxide primer over steel surfaces including preparation of new surface complete all as specified and directed. 25 s&f for pre painted galvaume aluminum zinc coating gi based manglore / trapezoidal / semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding, fixed with self tapping screws as specifiedcomplete all as specified and directed. nnote design / pattern / colour of roofing sheet sheet to decided and approved by eic / ge. 26 m & l for 0.63mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings ( length and girth as fixed ) with grade of zinc coating 275 complete all as specified and direcyed. 27 use and waste form work to sides of concrfete footings and similar works for fair finished surface all as specifed and directed. 28 use and waste of form work to edges of concrfete flats, slabs etc incl fair finished surface all as specifed and directed. 29 use and waste of form to staircases with sloping or stepped soffits including risers and stringers ( excluding landing ) complete as specified and directed. 30 m & l for plain cement concrete type b1 1:2:4 ( using 20 mm graded granite stone aggregate ) in foundations, filling and mass concrete. 31 m & l for formwork to sides and soffits of floor or roof beam, lintel beams flat surface etc incl supports, overhangs etc complete all as specified. 32 m&l for box type steel window 1.25 mm thick made of erw tube p section of size 60 x 25 mm double rebated outer frame comprise of glazed skeleton shutter ( two gauged shutters and two glazed shutter ) of erw tube p section size 50 x 20 mm and 1mm thick one / two nos openable leaf consisting of two nos sash bar of t section 20x3mm welded to frame with one no vertical mullion of erw box type t section of size 60 x 25 mm and 1.25 mm thick and fi 2 mm thick welded / screwed to frame for fixing of glass including fittings and fixture like handle, tower bolt, stopper, cleat, pintal hinges, hold fast etc. ( i ) hold fast, 150mm long of 120mm x 3 mm made to shape 04 nos per window. ( ii ) handle of z sec 20mm x 25mm, 100 mm long 1 no per leaf ( iii ) ms tower bolt 150mm long 2 no per leaf ( iv ) z sec 20mm x 25 mm, 100 mm long stopper 1 no per leaf ( v ) cleat 55 mm long of hollow square 15mm x 20mm x.63mm welded to hinge 1 no per leaf. ( vi ) ms pintal hinges of size 75mm x 12mm 2 nos per leaf . ( vii ) 10 mm square guard bar, 10 cm centre to centre. ( viii ) 25x4 mm flat iron all around for joint of both frame. ( ix ) stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples. ( x ) two coat of synthetic enamel paint to ms window and guard bar complete all as specified and directed. 33 s & f mild steel box type ventilator fixed type with glazing bar with mesh & glass as per drg no. cejz / td 06 / 07 dt 07.06.07 complete all as specified. 34 s&f tmt bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips and complete all as specified. 35 all as per item 34 here in before but 6 to 8 mm dia and including in stirrups, spacers and binders and complete all as specified. 36 supply and fixing mild steel roof truss, purlins, rail and fastenings and heavy bracket framing ( beam, tee, angle, channel, flat section ) including distrance pieces, welding work, cleats, nutand bolt etc ( fe 410w ) complete all as specified and directed. 37 s&f 1.25mm thick steel rolling shutter with ball bearing and gear operated type with bevel gear box and crank handle as specified including to hood cover , an choring rod, stopper, holdfast, pulling hook, sliding lock, handle hasp and staple and one coat of primer erected in position as indicated complete all as specified and directed by engg in charge. 38 s & f safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed by engg in charge. 39 s & f ball bearing for rolling shutters complete all as specified and directed. 40 supply and fixing pre painted galvalume aluminum zinc coating gi based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roof covering / cladding to wall, in ridges, hips, vally gutter, drip complete all as specified and directed by engineer in charge. 41 s & f mild steel plates ( plain or chequered ) channels, square cut or notched ( ordinary and counter sunk ) forming holes, without ant attachment ( fe 410 w ) gde e 250 quality a complete all as specified and as directed by engg in charge. 42 m&l for providing 75 mm thick cement concrete ( 1:3:6 ) type ci using 40mm graded stone aggregate as in plinth protection / pathway surfaces even and smooth without using extra cement. 43 m&l for pre cast rcc normal mix ( 1:2:4 ) type b1 ( using 20 mm graded stone aggregate ) . as in slabs supported on walls, beams and coloums in floors and roofs, landing balconies chaza, etc all as specified and directed . 44 m&l for 15 mm thick rendering on external surface with cement mortar ( 1:4 ) on fair face of brick or concrete surface finished even and fair using wpc @3% by weight of cement complete all specified and directed ( wpc shall be mesuredand paid saparately ) . 45 m&l for 15 mm thick rendering on internal surface with cement mortar ( 1:6 ) on fair face of brick or concrete surface finished even and fair complete all specified and directed . 46 m&l preparation of newly plastered surfaces and applying two coats of cement base paint of shade as approve over a coat of cement primer on wall complete all as specified and directed. 47 m & l for preparation of new plastered surface of walls and applying three coats of white wash as directed. 48 s&f in 3mm glass thick ordinary quality and glazing with oil putty or wooden beading and securing pins n.exc 0.50 sqm each panes complete all as specified and directed. 49 m & for reinforced cement concrete type b0 1:2:4 ( using 12.5 mm graded granite stone aggregate ) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in item 159, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed 50 supply, lowering, commissioning & testing of submersible pump capacity 1350 lpm at head of 80 mtr with out let size 100 mm dia bore including electric motor driven 415 v 50 hz complete all as specified and directed. 51 supply, lowering, commissioning & testing of submersible pump capacity 1650 lpm at head of 80 mtr with out let size 125 mm dia bore including electric motor driven 415 v 50 hz complete all as specified and directed. 52 supply, lowering and fixing ms heavy duty flanged pipe 5.4mm thick 100 mm bore ( length not less thatn 3 mtr each ) ms flanged not less than 15mm thick on both side, with drilled holes and welded to ms pipe, including material and labour for jointing, fixing with nuts, bolt, rubber packing complete all as specified and directed. 53 supply, lowering and fixing ms heavy duty flanged pipe 5.4mm thick 150 mm bore or nearest higher size bore ( length not less thatn 3 mtr each ) ms flanged not less than 15mm thick on both side, with drilled holes and welded to ms pipe, including material and labour for jointing, fixing with nuts, bolt, rubber packing complete all as specified and directed. 54 s&f submersible cable 25 sqmm, 3 core pvc copper cable, 1100 volts gradde conforming is 694, complete with all accessories all as specified and as directed. 55 supply, laying & fixing double wall corrugated ( dwc ) pipes for passing the cable along wall / under road, path etc made of high density polythyline ( hdpe ) with all accessories i.e. all type of joints, sockets, elbows, bends and end caps etc.. all as specified and directed by engr in charge.of size 40 mm outer dia and 38 mm inner dia of pipe 56 supply, install, testing & commissioning factory made indoor type dust and vermin proof motor starter panel cubical double door hinged type compartmentalized of suitable size fabricated of crca sheet 2.0 mm thick machine pressed and angle iron frame powder coated inside and outside, including 4 pole 415 volt, ac, 50 hz, copper busbar of capacity 300 amps mounted on porcelain insulators and enclosed in bus bar chamber and connection from incoming and outgoing electric cable with suitable size thimbs.lugs with openable shutters and fixed on angle iron frame made out from 40x40x6mm angle iron andgrounted in pcc 1:2:4, type b 1 ( using 20mm graded stone agregate ) , including accomodating & comprising of the following including taking out old unserviceable motor starter panel all as specified and directed : ( a ) mccb 250 amps capacity with adjustable thermal release 4 pole of 25 ka rupturing capacity 01 no ( incomming ) . n ( b ) mccb 160 amps 25ka , three pole 415 volt 01 no. ( outgoing ) n ( c ) mcb 32 amps 10 ka tpn 415 volt 02 no. ( out going ) ( d ) ( i ) digital volt meter showing 0 500 volts complete with duly nprewired with copper cable of suitable size 01 no. ( ii ) digital ampere meter showing 0 100 amps with 01 no. n ( iii ) indication lamp ryb led type with protection fuses 01 set ( iv ) soft starter in steel enclosure comprising of the following appliances of make l&t csxi model cat part csxi 037 41 or equivalent in siemens, havells etc: na ) in built bypass contractor nb ) soft start / start stop / adjustable current limit nc ) essential motor protection against ( i ) overload ( ii ) single phasing ( iii ) instantaneous overcurrent ( iv ) phase sequence reversal ( v ) abnormality in supply ( vi ) unbalanced current nd ) thermistor protection through ptc ne ) excess start time setting 57 m & l for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level connected an including gi strip 32 x 6 mm as earth lead upto 7.5 mtr long by means of bolts, nuts, check nuts and washers etc with gi protection pipe of 40 mm bore medium grade and connected to earthing test point all as shawn in electrical plate no 3 of sr part i and as specified or indicated including excavation & earth work in any type of soilpcc ( 1:2:4 ) type b1 ( reinforced with welded steel wire fabric ( xpm ) of weight not less than 4 kg ( sqm ) with frame funnel with 20 mm bore gi pipe medium grade watering pipe, wire mesh and lugs test point etc and testing on completion. nnot : ( a ) the unit rates includes 32 x 6mm gi pipe strip and 40mm gi protection pipe top of earth plate upto test point ) 58 m&l for point wiring with 1.5 sqmm ( nominal area ) 1100 volt pvc insulated , frls unsheathed and multi stranded copper conductor cable in and including new pvc concealed conduit not less than 20mm dia 1.5mm thick for one light / fan point or bell point controlled by one switch ( including cutting chases and making good the disturbed surfaces ) and fixing new 3mm thick hylem sheet top cover, sheet screws and 1.6mm thick gi sunken boxes included 1.5 sqmm stranded copper conductor with green pvc insulation earth contunity conductor connected to common earth dolly etc . complete all as specified and directed. note : the cost of sunken boxes and bakellite sheet is included in the quoted rate ) 59 all as per item 58 here in before but for one three pin socket outlet 5 amps independent board complete 60 all as per item 58 here in before but for one three pin 5 amps socket outlet on the same board with other switches 61 all a per item no 58 here in above but with 2.5 sq mm size cable multi stranded frls copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continuous earth wire of pvc insulated 1.5 sq mm copper solid conductor connecting to common earth dolly complete. 62 supply and fixing switch piano type 6 amps one way 230 volts ac complete all as specified and as directed 63 supply and fixing socket outlet 5 pin, 6 amps flush type 230 volts ac complete all as specified and as directed 64 supply and fixing switch piano 16 amps type one way 230 volts ac complete all as specified and as directed 65 supply and fixing socket outlet 6 pin 6 / 16 amps multi purpose flush type 230 volts ac complete all as specified and as directed 66 supply and fixing ceiling rose 65x50 mm two to three terminals complete all as specified. 67 material and labour of lamp holder insulated body with back plate angle type for batten fitting fixed on bakelite sheet 100mmx100mm with 10 watt led bulb 230v ac cool day light 6500k having maximum height 1020mm heavy duty complete all as specified. 68 m&l for two single core sub main wiring 6 sqmm multi strand pvc insulated frls copper conductor cable including pvc insulated copper conductor cable of size 6 sqmm as cotinuous earth wire connecting to common earth including pvc conduit , connections of cable with mcbs or bus bars complete all as specified and directed 69 m & l for sheet steel enclouser distribution boards, double door factory made 3 phase 415 volts 4 way with 200 amps rating copper bus bar and pvc insulated copper jumpers of suitable size from the mccb to the out going circuits one incoming mccb and 12 outgoing mcbs circuits comprising of 3 phase 4 wire of suitable rating complete all as spcd and directed with the following accessories : ( for out going mcb measured and paid for separately ) ( a ) mccb 100 amps, 16 ka, tp, 415 volts, 50 hz = 01 no. 70 supply and fixing mcb single pole 6 to 32 amps all as specified and directed 71 supplying and fixing mcb dp 40 amps 240v, 10 ka, complete all as specified and as directed 72 m&l for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by gi pipe 15 mm bore ( light grade ) and watering pipe 20 mm bore gi pipe ( light grade ) and chamber of pcc 1:4:8 type d2 using 40 mm graded stone aggregate and coping shall be in pcc 1:3:6 type c1 using 20mm graded stone agg. 50 mm thick cover of rcc 1:2:4 type b1 using 20 mm graded stone agg. reinforced with 8 mm dia ms tor bar @ 80 mm c / c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of ssr pt 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point ( up to main switche, dbs ) complete all as specified & testing on completion. 73 supply & fix of led street light luminaire 25 watt 6000k with .high power led cool white, cri 75, + / 5% supply voltage 220 / 240 / 50 hz, light engine driver base.pole adapter, powder coated pressure die cast aluminium with heat resistant toughened glass with lens.complete all as specified and as directed. 74 supply & laying xlpe insulated armoured heavy duty electric cable with aluninium conductor 1100 volt grade cross section area 4 core 25 sqmm complete all as specified and as directed. 75 supply, laying & fixing double wall corrugated ( dwc ) pipes made of high density polythyline ( hdpe ) with all accessories i.e. all type of joints, sockets, elbows, bends and end caps etc.. all as specified and directed by engr in charge.of size50 mm outer dia and 38 mm inner dia complete all as specified and directed. 76 supply and fixing of led t 8 tube light fitting with single side connection led tube rod 18 / 20w 4 feet 1 x 18 / 20 watt ms crca box type including rotary type bipin holder and connection with pvc insulalted twin core 23 / 0.0076 twisted copper cable from ceiling rose to tube light fitting complete all as specified and directed. 77 supply and laying or fixing 1100 volts grade heavy duty cable with pvc insulated aluminium standard conductor served with an inner sheathing of pvc tape and over all pvc sheathed in service connections one twin core 6 sqmm cable standard conductor cable flat or circular all as specified and directed by engineer in charge. 78 s &f sheet metal enlosure for dbs where mcbs to be used double door factory made flush fixed complete with 100 amps rated bus bar 240 volts single phase 8 ways complete all as specified. 79 s &f led bulk head light fittings 10watt white including led strip as per ip65 in enginnering plastic housing withclear prismatic diffuser and making necessary connections complete all as specified 80 s & f bracket made out of gi pipe 40mm medium grade 1.2 mtr long made to shape with fixing clamps of ms flat 40x6mm nuts bolts etc for street light all as specified vand direceted. 81 supply & fixing flood light luminaire 120 watt with high power smd led cool white, supply voltage 220 / 240 / 50 hz, light engine driver base pole adapter, pressure die cast, polycarbonate, powdre coated in ip 66 incliding protection over temperature should be from the same manufacturer product complete all as specified and as directed, 82 supply and fixing ceiling fan 1200mm sweep copper winding with electronic regulator, low power consumption, high speed aluminium body with blade, double ball bearing of bee star rated including acessories connector, canopy, hanging rod and clamps , including electric connection with pvc flexible twin core copper wire from ceiling rose to ceiling fan complete all as specified and directed....

Military Engineer Services - Punjab

24846393 periodical services incl camouflaging paint , plaster works to the amn sheds and other bldgs in technical area at mil stn dappar under ge ( p ) dappar , m&l for two coats of synthetic enamel paint camouflage paint including praparation of old steel surfaces to receive painting , washing and cleaning , of any description over 10 cm width or girth not otherwise described complete all as specified and directed . , m&l for applying acrylic thick wall care putty on internal / external surfaces of walls / ceilings / soffits ( thickness vary from 1 . 5 to 2 . 5 mm as required for desired smoothness and levelling of surfaces in two or more layers ) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed . make of wall putty : jk wall putty / birla wall care putty / bison wall putty . notes : ( i ) the prepared surface after wall putty , the contractor will inform to the ge as well as to the engineer in charge for site inspection before applying further finishes . please note that the further finishes work will start only after approval of the prepared surface from the ge as well as to the engineer in charge through site order . , applying 02 coats of exterior emulsion paint ( light shade ) @ 5 sq . m / litre / 2 coats by using roller / brush to external walls / rcc surfaces / soffits of chajjas / roof projections / cantilevers / balcony etc surfaces over & including a coat of exterior wall primer @ 11 sq . m / litre / 1 coat by roller burss or or mechnical spray all as directed by engr in charge as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed . make of exterior wall primer : asian / berger / nerolac [ best quality ] . make of exterior emulsion : asian ( ace ) / berger ( walmasta ) / nerolac ( suraksha superior ) , taking down cement plaster on brick wall on concrete surfaces incl hacking for key racking out joints scrubbing down with water etc . , m&l for cement plastering 15mm thick in two layers ( 10mm and 5mm respectively ) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturers instructions on brick work or concrete surfaces or in chajjas / parapet walls etc finished even and smooth without using extra cement complete all as specified and as directed by engineer in charge . note : wpc will be measured and paid separately . , supply only integral liquid water proofing compound complete all as specified & as directed by engineer in charge . make : pidilite / sika , m&l for applying 02 coats of interior emulsion paint ( light shade ) @ 10 sq . m / litre / 2 coats by using roller or mechnical spray all as directed by engr in charge to wall surfaces over & including a coat of interior wall primer @ 10 sq . m / litre / 1 coat as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed . make of interior wall primer : asian / berger / nerolac [ best quality ] . make of interior emulsion : asian ( tractor ) / berger ( bison ) / nerolac ( beauty smooth ) . , m & l for preparing existing treated surfaces of external walls / rcc surfaces / soffits of chajjas / roof projections / cantilevers / balcony etc including cornices and applying one coat of cement base paint @ 5 sq . m / kg / 1 coat by using following brands of cement based paint by roller complete all as specified & as directed by engineer in charge . make of cement paint : snowcem plus ( snowcem paints ) / asian / berger , m & l for preparing existing treated surfaces on ceiling including cornices and applying one coat of white wash by making the lime slaked at site and shall be mixed and stirred with about five liters of water for 1 kg of unslaked lime to make a thin cream . this shall be allowed to stand for a period of 24 hours and shall then be screened through clean coarse cloth . 1 kg of gum dissolved in hot water shall be added to every one cubic meter of lime cream . about 1 . 3 kg of sodium chloride dissolved in hot water shall also be added for every 10 kg of lime for making the coating hard and rub resistant . small quantity of ultramarine blue ( upto 3 gm per kg of lime ) shall also be added to the of white wash solution and the whole solution shall be stirred thoroughly before use complete all as specified and as directed by engineer in charge ....

Military Engineer Services - Punjab

23230369 purchase of stores , berger exterior water emulsion paint walmasta dark colour , berger exterior water emulsion paint walmasta light colour...

Bhakra Beas Management Board - Punjab

20810602 providing whitewashing, plastic emulsion paint on internal walls and synthetic enamel paint on doors and s of occupied bungalows, transport and store sub division and snowcem on external walls of c and d type quarters of eb colony at nangal township. => limited tender...

Bhakra Beas Management Board - Punjab

20800955 tender for providing whitewashing, plastic emulsion paint on internal walls and synthetic enamel paint on doors and windows of occupied bungalows, transport & store sub division and snowcem on external walls of c & d type quarters of eb colony at nangal township....

Bhakra Beas Management Board - Punjab

19988932 tender for providing white washing, plastic emulsion paint on internal walls and synthetic enamel paint on doors and windows of occupied bungalows, transport & store sub division and snowcem on external walls of c&d type quarters of eb colony at nangal township...

Ministry Of Communication And Information Technology - Punjab

18652752 tender for the work of provision of up gradation of parcel hub at rms, amritsar 1. acrylic emulsion paint 2. premium acrylic smooth exterior paint 3. aluminium composite panel 4. aluminium extrusions 5. aluminum sections 6. board & plywood 7. ceramic/rectified tiles 8. cp fittings 9. cpvc pipes 10. designer coloured cement concrete floor tiles for external used / concrete paver blocks. 11. epoxy primer & paints 12. float glass 13. flush doors (isi mark only) 14. galvanized/stainless steel anchor fasteners 15. gun metal gate valve 16. gypsum board false ceiling 17. hardner 18. hydraulic door closer 19. hydraulic floor spring 20. laminate 21. melamine polish 22. m. s. pipe 23. marine plywood / bwp ply 24. oil bound distemper 25. sanitary fittings 26. plastic connection pipe 27. ply wood 28. pre coated gi sheet for roofing 29. polymer modified cementitious grout 30. pre laminated particle board is : 12823 (gr i, type ii) 31. primer 32. pvc rain water pipe & fitting is:13592 type a 33. pvc shutter 34. pvc tank (isi marked) 35. r. c. c. pipes (np 2) 36. solid plastic seat cover for ewc 37. stainless steel 38. stainless steel sink with or without draining board. 39. structural silicon sealant 40. structural steel section 41. synthetic enamel paints 42. textured exterior wall paint 43. towel ring/towel rod/towel rack. 44. tubular section windows 45. tmt bars 46. vitrified tiles 47. waste pipe 48. water proofing compound (liquid) 49. wire mesh 50. white cement 51. wall putty 52. work stations/ modular furniture 53. stoneware pipe and gully trap 54. pvc flushing system 55. tactile tiles 56. plastic emulsion paint....

Bhakra Beas Management Board - Punjab

18605582 tender for procurement of synthetic enamel paints of 1st quality of different shades, emulsion paint, primer etc of make british/nerolac/asian/berger paint confirming to relevant....

Rural Development and Panchayat Raj Department - Punjab

18116223 supply of materials for the construction of nrega bhawan at vill. taranjikhera distt. sangrur ( nrega work ) ( re tender ) : 23 wall painting with plastic emulsion paint of approved brand and manufacturers (two coats) etc 24 finishing walls with acrylic smooth exterior paint or required shade with two coats applied @ 1.67 ltr/10 sqm etc. 25 prepration of plywood surface for painting i/c sand papering etc. 26 painting three coats including priming coat in all shade on new wood work. 27 painting three coats including priming coat in all shade on new steelwork. skilled labour 28 earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation. 29 cement concrete 1:8:16 with 40mm gauge brick ballast. 30 first class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. 31 reinforced cement concrete m 20 with cement @375/kg per cum hand mixed but excluding steel reinforcement centring and shuttering in foundation and plinth. 32 earth filling under floors surpluss soil etc. 33 first class burnt brick work laid in cement sand mortar 1:6 in super structure. 34 115 mm thick brick wall laid in cement sand mortar 1:4 without reinforcement in f&p. 35 115 mm thick brick wall laid in cement sand mortar 1:4 without reinforcement in super structure. 36 reinforced cement concrete m 20 with cement @375/kg per cum hand mixed but excluding steel reinforcement centring and shuttering in superstructure. 37 plain cement concrete 1:2:4. ...

Rural Development and Panchayat Raj Department - Punjab

18078473 supply of materials for the construction of nrega bhawan at vill. bir kalan distt. sangrur ( nrega work ) re tender 1 supply of brick bats. 2 supply of coarse sand. 3 supply of crushed bajri. 4 supply of good earth. 5 carriage of bricks. 6 supply & fixing of pressed steel frames ( chowkats ) consisting of 18 gauge ( 1.25mm ) thick steel sheet of the specified section ( standard design latest ) including iron lugs ( hold fasts ) iron hinges, confirming to p.w.d. specifications including bolts etc. ( a ) single rebate ( b ) double rebate 7 for estimate purpose shuttering may be taken as under ( a ) for foundation work & plinth beam. ( b ) for slab & stair case. ( c ) for columns beams, door lintles. 8 extra for smooth surface for finishing of rcc work. 9 terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling etc. 10 wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, etc. 11 supplying & fixing open able steel windows of standares rolled steel sections, joints etc. 12 supply of vitrified floor tiles 600 x 600 mm size. 13 anti skid floor tiles 10mm thick in flooring. 14 ceramic tiles 20cm x 20cm & 5mm thick in skirting dado on walls. 15 providing & fixing 110mm dia s.w.r. u.p.v.c. bend for rain water pipe etc. 16 providing & fixing 110mm dia s.w.r. u.p.v.c. bend for p.v.c. bend rain water pipe etc. 17 supply & fixing glass panes with glazing clips and special metal sash putty etc. ( 4mm thick above 0.40 sqm. area ) 18 wire gauge fixed on window of standard etc. 19 factory manufactured solid flush door 35mm thick fixed in position etc. 20 cost of aluminium fitting i.s.i. 21 providing and fixing aluminium sliding bolts. 22 preparation of plaster or concrete surface for painting ( indcluding sand papering the surface ) etc. 23 wall painting with plastic emulsion paint of approved brand and manufacturers ( two...

Rural Development and Panchayat Raj Department - Punjab

18078459 supply of materials for the construction of nrega bhawan at vill. taranjikhera distt. sangrur ( nrega work ) ( re tender ) : 23 wall painting with plastic emulsion paint of approved brand and manufacturers (two coats) etc 24 finishing walls with acrylic smooth exterior paint or required shade with two coats applied @ 1.67 ltr/10 sqm etc. 25 prepration of plywood surface for painting i/c sand papering etc. 26 painting three coats including priming coat in all shade on new wood work. 27 painting three coats including priming coat in all shade on new steelwork. skilled labour 28 earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation. 29 cement concrete 1:8:16 with 40mm gauge brick ballast. 30 first class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. 31 reinforced cement concrete m 20 with cement @375/kg per cum hand mixed but excluding steel reinforcement centring and shuttering in foundation and plinth. 32 earth filling under floors surpluss soil etc. 33 first class burnt brick work laid in cement sand mortar 1:6 in super structure. 34 115 mm thick brick wall laid in cement sand mortar 1:4 without reinforcement in f&p. 35 115 mm thick brick wall laid in cement sand mortar 1:4 without reinforcement in super structure. 36 reinforced cement concrete m 20 with cement @375/kg per cum hand mixed but excluding steel reinforcement centring and shuttering in superstructure. 37 plain cement concrete 1:2:4. ...

Hindustan Petroleum Corporation Limited - Punjab

18033871 tender for du installation work supplying & fixing m25 grade precast concrete poles for fencing with 6mm stirrups welded to four 8mm main vertical reinforcement size of pole 6’.o” length with bottom section 3”x4” & top section 3”x3” erecting, placing. grouting in proper line, levelled & painting of the pole with two coats of acrylic emulsion paint exterior grade over a coat of cement primer etc. completed as per the instnuction of ens. in charge(refer attached drawing) fixing of hpcl logo box in line and level on the granite curtain wall with the help of necessary fasteners surface dressing of the ground including removing small plants. bushes ,vegetation (dia less than 4”) and making surface levelled and disposal of rubbish outside hpcls premises to an unobjectionable place, as directed by the engnneer in charge etc.....

Rural Development and Panchayat Raj Department - Punjab

17875891 tender for supply of materials for the construction of nrega bhawan at vill. taranjikhera block dirba distt. sangrur ( nrega work ) : 23 wall painting with plastic emulsion paint of approved brand and manufacturers (two coats) etc. 24 finishing walls with acrylic smooth exterior paint or required shade with two coats applied @ 1.67 ltr/10 sqm etc. 25 prepration of plywood surface for painting i/c sand papering etc. 26 painting three coats including priming coat in all shade on new wood work. 27 painting three coats including priming coat in all shade on new steelwork. skilled labour 28 earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation. 29 cement concrete 1:8:16 with 40mm gauge brick ballast. 30 first class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. 31 reinforced cement concrete m 20 with cement @375/kg per cum hand mixed but excluding steel reinforcement centring and shuttering in foundation and plinth. 32 earth filling under floors surpluss soil etc. 33 first class burnt brick work laid in cement sand mortar 1:6 in super structure. 34 115 mm thick brick wall laid in cement sand mortar 1:4 without reinforcement in f&p. 35 115 mm thick brick wall laid in cement sand mortar 1:4 without reinforcement in super structure. 36 reinforced cement concrete m 20 with cement @375/kg per cum hand mixed but excluding steel reinforcement centring and shuttering in superstructure. 37 plain cement concrete 1:2:4. ...

Indian Army - Punjab

17549826 supply of store for security fence 102 galvanised steel sheets & colour coated galvanised steel sheets 103 polycarbonate sheet 104 galvalume sheets 105 gypsum board 106 pvc tiles / sheets 107 terrazzo tiles / ppc tiles / ppc chequered tiles 108 interlocking tiles / exterior tiles / paver blocks 109 decorative textures / coatings 110 glazed earthen ware tiles / floor tiles 111 vitrified tiles ( normal / anti skid ) 112 glazed ceramic / non skid floor tiles 113 hdpe storage water tank 114 sanitary appliance / fittings ( china ware ) 115 water closet sheet and cover ( solid bakelite ) thermostat moulded toilet sheet cover 116 pvc flusing cistems 117 ci flusing cistem 118 stainless steel kitchen sink with or without draining board plate rack 119 ball valves ( horizontal plunger tile ) 120 shower roses chromium plate ( swivel type ) 121 bathroom fancy fitting 122 bib taps and stop taps ( cp fancy fitting ) 123 readymade bathroom cabinets 124 salt glazed stone ware pipe / glass stone ware pipe 125 pvc rain water, pipe sewage pipe 126 gi pipes / fitting 127 ppr itmes 128 ci pipes fitting ( for sewerage / rain water ) 129 tee junction pvc 130 soil ate pipe fitting / steel manhole cover 131 hdpe pipe / snr pipes ( water / sewage ) 132 sand cast iron spigot & socket soil waste vent pipes & fitting 133 cement based paints 134 dry distemper / oil buund distemper plastic emulsion / exterior emulsion silicon paints and coating 135 plastic emulsion paints 136 prime for wood / steel 137 paint exterior 138 synthetic enemal paints 139 false ceiling tiles / board ( gypsum board / pop / mineral fibre ) 140 mirror looking 141 false ceiling 142 adhesive 143 cement 144 handyman tools ( spanner, drills etc ) 145 matress 146 frp septic tank...