Department Of Fertilizers - Punjab

39100492 bids are invited for hydrogen gas 99.999% pure in party own cylinders (q3) , nitrogen gas 99.999% pure in party own cylinders (q3) total quantity : 600...

Punjab State Power Corporation Limited - Punjab

35704727 tender for work of routine, breakdown & preventive mtc. and overhauling jobs of various mechanical auxiliaries comprising of hydrogen gas plant, dm plant, fire fighting system, vertical & horizontal pumps, air compressors, etc connected lp piping & valves, operation & maintenance of mechanical workshop and plant drainage pumps of 2 x 210 mw & 2 x 250 mw ghtp stage i & ii, on lump sum basis for a period of one year....

Department Of Fertilizers - Punjab

35701457 bids are invited for various type of gas detectors hydrocarbon gas detector along with sensor , hydrogen gas detector along with sensor , h2s gas detector along with sensor , co gas detector along with sensor , ammonia gas detector along with sensor , oxygen depletion gas detector along with sensor total quantity : 20...

Hindustan Insecticides Limited - Punjab

35671574 supply of the following material(s) 1. refilling of nitrogen cylinder (10 m3) 2. refilling of hydrogen gas cylinder filling 7 cu.m 3. refilling of zero air gas cylinder filling 7 cum...

Punjab State Power Corporation Limited - Punjab

34673429 tender for breakdown/ preventive mitc and overhauling of dm plants, dg sets, compressors, hydrogen gas plants, fire protection system, ac system and other allied mechanical auxiliaries of stage ii and iii for units bhel make 210 mw each and work of central mechanical workshop...

Punjab State Power Corporation Limited - Punjab

34647585 breakdown / preventive mtc. & overhauling of dm plants, d.g. sets, compressors, hydrogen gas plants, fire protection system, ac system and other allied mechanical auxiliaries of stage ii and iii for 4 units bhel make 210 mw each and work of central mechanical workshop at ggsstp, rupnagar....

National Fertilizers Limited - Punjab

34370377 spx / 2022 / 196 process gas clean moisture filter process gas clean moisture filter , process gas clean moisture filter make : agilent technology part no. of filter : cp17971p service : installed on carrier gas to gas chromatographs ( ae 1002 & ae 1013 ) to absorb moisture in hydrogen gas. quantity= 10nos....

Punjab State Power Corporation Limited - Punjab

33817040 breakdown / preventive maintenance & overhauling of dm plants, d.g. sets, compressors, hydrogen gas plants, fire protection system, ac system and other allied mechanical auxiliaries of stage ii and iii for 4 units bhel make 210 mw each and work of central mechanical workshop at ggsstp, rupnagar...

National Fertilizers Limited - Punjab

32421443 supply of gas detectors tender no. nfb / pur / sa / 210158 dt 26.03.2022 for gas detectors , lab items , item code 8080879 two wire loop powered ammonia gas detector complete unit for hazardous area with following or better specifications gas sensor moduletype electrochemical, gas ammonia, ran ge 0 to 100 ppm ammonia, response time 50 percent full scale in less than 15 sec, transmitter with display unit explosion proof design, local display backlit lcd display, operation voltage 24vdc, user input switch on display panel, output linear 4 to 20 ma output, hart enable ( optional ) , error less than 2 percent of urv, approvals fm / csa / atex / iecex / ccoe , classification explosion proof, rating ip64 or better, operating temperature between 20 to 50 degc, cable entry 1 / 2 inch npt ( f ) , mounting bracket, cable glands, plugs & other accessories required for installation & calibration of detector qty= 3 no. , item code 8080950 three wire loop powered hydrocarbon gas detector complete unit for hazardous area with following or better specifications gas sensor moduletype catalytic, gas hydrocarbon, range 0 to 100 percent lel standard, response time 50 percent full scale in less than 15 sec within 100 percent lel applied, transmitter with display unit explosion proof design, local display backlit lcd display, operation voltage 24vdc, user input switch on display panel, output linear 4 to 20 ma output, hart enable ( optional ) , error less than 2 percent of urv, approvals fm / csa / atex / iecex / ccoe , classification explosion proof, rating ip64 or better, operating temperature between 20 to 50 degc, cable entry 1 / 2 inch npt ( f ) , mounting bracket, cable glands, plugs & other accessories required for installation & calibration of detector qty= 2 no. , item code 8080951 three wire loop powered hydrogen gas detector complete unit for hazardous area with following or better specifications gas sensor moduletype catalytic, gas hydrogen, range 0 to 100 percent lel standard, response time 50 percent full scale in less than 15 sec within 100 percent lel applied, transmitter with display unit explosion proof design, local display backlit lcd display, operation voltage 24vdc, user input switch on display panel, output linear 4 to 20 ma output, hart enable ( optional ) , error less than 2 percent of urv, approvals fm / csa / atex / iecex / ccoe , classification explosion proof, rating ip64 or better, operating temperature between 20 to 50 degc, cable entry 1 / 2 inch npt ( f ) , mounting bracket, cable glands, plugs & other accessories required for installation & calibration of detector qty= 1 no. , item code 8080952 two wire loop powered co gas detector complete unit for hazardous area with following or better specifications gas sensor moduletype electrochemical, gas co, range 0 to 100 ppm co, response time 50 percent full scale in less than 15 sec, transmitter with display unit explosion proof design, local display backlit lcd display, operation voltage 24vdc, user input switch on display panel, output linear 4 to 20 ma output, hart enable ( optional ) , error less than 2 percent of urv, approvals fm / csa / atex / iecex / ccoe , classification explosion proof, rating ip64 or better, operating temperature between 20 to 50 degc, cable entry 1 / 2 inch npt ( f ) , mounting bracket, cable glands, plugs & other accessories required for installation & calibration of detector qty= 2 no. => limited...

National Fertilizers Limited - Punjab

32320622 gas detectors tender no. nfb / pur / sa / 210158 dt 26.03.2022 for gas detectors , lab items , item code 8080879 two wire loop powered ammonia gas detector complete unit for hazardous area with following or better specifications gas sensor moduletype electrochemical, gas ammonia, ran ge 0 to 100 ppm ammonia, response time 50 percent full scale in less than 15 sec, transmitter with display unit explosion proof design, local display backlit lcd display, operation voltage 24vdc, user input switch on display panel, output linear 4 to 20 ma output, hart enable ( optional ) , error less than 2 percent of urv, approvals fm / csa / atex / iecex / ccoe , classification explosion proof, rating ip64 or better, operating temperature between 20 to 50 degc, cable entry 1 / 2 inch npt ( f ) , mounting bracket, cable glands, plugs & other accessories required for installation & calibration of detector qty= 3 no. , item code 8080950 three wire loop powered hydrocarbon gas detector complete unit for hazardous area with following or better specifications gas sensor moduletype catalytic, gas hydrocarbon, range 0 to 100 percent lel standard, response time 50 percent full scale in less than 15 sec within 100 percent lel applied, transmitter with display unit explosion proof design, local display backlit lcd display, operation voltage 24vdc, user input switch on display panel, output linear 4 to 20 ma output, hart enable ( optional ) , error less than 2 percent of urv, approvals fm / csa / atex / iecex / ccoe , classification explosion proof, rating ip64 or better, operating temperature between 20 to 50 degc, cable entry 1 / 2 inch npt ( f ) , mounting bracket, cable glands, plugs & other accessories required for installation & calibration of detector qty= 2 no. , item code 8080951 three wire loop powered hydrogen gas detector complete unit for hazardous area with following or better specifications gas sensor moduletype catalytic, gas hydrogen, range 0 to 100 percent lel standard, response time 50 percent full scale in less than 15 sec within 100 percent lel applied, transmitter with display unit explosion proof design, local display backlit lcd display, operation voltage 24vdc, user input switch on display panel, output linear 4 to 20 ma output, hart enable ( optional ) , error less than 2 percent of urv, approvals fm / csa / atex / iecex / ccoe , classification explosion proof, rating ip64 or better, operating temperature between 20 to 50 degc, cable entry 1 / 2 inch npt ( f ) , mounting bracket, cable glands, plugs & other accessories required for installation & calibration of detector qty= 1 no. , item code 8080952 two wire loop powered co gas detector complete unit for hazardous area with following or better specifications gas sensor moduletype electrochemical, gas co, range 0 to 100 ppm co, response time 50 percent full scale in less than 15 sec, transmitter with display unit explosion proof design, local display backlit lcd display, operation voltage 24vdc, user input switch on display panel, output linear 4 to 20 ma output, hart enable ( optional ) , error less than 2 percent of urv, approvals fm / csa / atex / iecex / ccoe , classification explosion proof, rating ip64 or better, operating temperature between 20 to 50 degc, cable entry 1 / 2 inch npt ( f ) , mounting bracket, cable glands, plugs & other accessories required for installation & calibration of detector qty= 2 no. => limited...

Indian Institute Of Science Education And Research - Punjab

31147761 supply, installation and commissioning of gas chromatograph mass spectrometer ( gc ms ) instrument with accessories 1532 supply, installation and commissioning of gas chromatograph mass spectrometer ( gc ms ) instrument with accessories 1532 , supply, installation and commissioning of gas chromatograph mass spectrometer ( gc ms ) instrument with accessories ( as per technical details given below ) , gc oven ( as per technical details given below ) , programmable split / split less capillary injector ( as per technical details given below ) , auto sampler ( as per technical details given below ) , fi detector ( as per technical details given below ) , ms detector ( as per technical details given below ) , software ( as per technical details given below ) , columns ( as per technical details given below ) , other essentials: helium gas cylinders ( as per technical details given below ) , hydrogen gas cylinder ( as per technical details given below ) , zero air gas cylinder ( as per technical details given below ) , nitrogen gas cylinder ( as per technical details given below ) , double stage isi marked ss regulators for each cylinder ( as per technical details given below ) , wall mount gas purification system for he, n2, h2, zero air ( as per technical details given below ) , air compressor with 5 years warranty ( as per technical details given below ) , 1. online ups: suitable on line ups with at least one hour back up 2. computer: oem pc or intel i7 processor with windows desktop ( i5 or better processor with mac ) . 22 inch screen or better. full hd monitor. hdd minimum 500 gb. minimum 16 gb ram. optical dvd recordable, wired and wireless operating system with latest operating system for mac / windows, mouse and keyboard. 3. printer: compatible laser printer ( as per technical details given below ) , consumables: auto sampler syringe ( as per technical details given below ) , consumables: liner for split / splitless mode ( as per technical details given below ) , consumables: compatible ferrules for ms ( as per technical details given below ) , consumables: filaments ( as per technical details given below ) , consumables: vacuum pump oil ( as per technical details given below ) , consumables: 2 ml vials with screw caps ( as per technical details given below ) , consumables: screw caps & septa for 2 ml vials ( as per technical details given below ) , consumables: inlet septa ( as per technical details given below ) , consumables: jet for fid ( as per technical details given below ) , consumables: column nut for fid ( as per technical details given below ) , consumables: column nut for ms ( as per technical details given below ) , consumables: calibration standard for ei mode ( as per technical details given below ) , consumables: column cutter ( as per technical details given below ) , consumables: o rings 20 ( as per technical details given below ) , consumables: glass wool ( as per technical details given below ) , optional items: hydrogen generator with 5 year warranty ( as per technical details given below ) , optional items: nitrogen generator with 5 years warranty ( as per technical details given below ) , optional items: zero air gas generator with 5 year warranty ( as per technical details given below ) , any other charges, if any ( a ) , any other charges, if any ( b ) , any other charges, if any ( c ) ...

Indian Institute Of Science Education And Research - Punjab

30845229 supply and installation of gas chromatograph for liquid samples 1530 supply and installation of gas chromatograph for liquid samples 1530 , supply & installation of gas chromatograph for liquid samples ( as per technical details as givenbelow ) , gas chromatograph ( as per technical details as givenbelow ) , gc oven ( as per technical details as givenbelow ) , split / splitless capillary injector ( as per technical details as givenbelow ) , fid ( as per technical details as givenbelow ) , suitable 30m hp 5 or equivalent capillary column from oem for analysis organic compounds. ( as per technical details as givenbelow ) , software: system should be quoted with original licensed software needed to control the system along with original cds ( as per technical details as givenbelow ) , essential accessories: • hydrogen gas cylinder with double stage ss regulators for each gas. ( as per technical details as givenbelow ) , essential accessories: • zero air gas cylinder with double stage ss regulators for each gas. ( as per technical details as givenbelow ) , essential accessories: • nitrogen gas cylinders with double stage ss regulators for each gas. ( as per technical details as givenbelow ) , essential accessories: • gas purification panel. ( as per technical details as givenbelow ) , essential accessories: • ss tubing with colored sleeves for each gas : 20 feet for each gas.total 60 feet. ( as per technical details as givenbelow ) , essential accessories: • pvc casing for gas lines: 20 feet ( as per technical details as givenbelow ) , essential accessories: • ferrules, nuts, union & clamps as per installation requirements. ( as per technical details as givenbelow ) , autosampler ( as per technical details as givenbelow ) , essential consumables from oem: • vials and caps 1000 • liner 10 • ferrules 10 • column nut 10 • septa 50 • autosampler syringe 2 ( as per technical details as givenbelow ) , any other charges, if any ( a ) , any other charges, if any ( b ) , any other charges, if any ( c ) , any other charges, if any ( d ) ...

Punjab State Power Corporation Limited - Punjab

29781431 procurement of spares for hydrogen gas plant at ggsstp rupnagar procurement of spares for hydrogen gas plant at ggsstp rupnagar , electrode plate for hydrogen gas plant without nickel plating ( as per drawing at annexure i ) , complete set of bell ( for water electrolytic cell for generation of hydrogen gas having generating cell capacity 0.85 nm3 / hr., 99.9% purity ) fitted with 5 cathodes+4 anodes separated with asbestos sheet and having d.c. current 2000 amps. 2.5 volts per cell as per annexure i....

Punjab State Power Corporation Limited - Punjab

29781387 procurement of spares for hydrogen gas plant at ggsstp rupnagar , electrode plate for hydrogen gas plant without nickel plating ( as per drawing at annexure i ) , complete set of bell ( for water electrolytic cell for generation of hydrogen gas having generating cell capacity 0.85 nm3 / hr., 99.9% purity ) fitted with 5 cathodes+4 anodes separated with asbestos sheet and having d.c. current 2000 amps. 2.5 volts per cell as per annexure i....

Department of Cooperation - Punjab

29746404 supply of hydrogen gas cylinders supply of hydrogen gas cylinders , compressed hydrogen gas in cylinders of 7nm3 water capacity...

Institute of Nano Science and Technology - Punjab

29435600 annual rate contract for refiling of various analytical gases annual rate contract for refiling of various analytical gases as per nit document attached. , argon gas purity 99.999% , argon gas purity 99.9999% , carbon dioxide per kg gas purity 99.99% , carbon dioxide per kg gas purity 99.999% , carbon dioxide per kg gas purity 99.9999% , nh3 ( ammonia ) gas purity 99.999% , helium gas purity 99.999% , helium gas purity 99.9999% , hydrogen gas purity 99.999% , nitrogen gas purity 99.999% , nitrogen gas purity 99.9999% , oxygen gas purity 99.99% , oxygen gas purity 99.999% , oxygen gas purity 99.9999% , zero air gas purity 99.999% , zero air gas purity 99.9999% , ch4 methane 99.999% , ( argon 90% + hydrogen10 % ) 99.999% , ( argon 95% + hydrogen 05 % ) 99.999% , ( ammonia 10% + helium 90 % ) 99.999% , ethane gas purity 99.999% , ( argon 80% + hydrogen 20 % ) 99.999% , carbon monoxide gas purity 99.97% , flue gas ( 12% co2 + 7% o2 + 1500ppm so2 + 470 ppm nox + balance n2 ) , any other charges, if any ( a ) , any other charges, if any ( b ) , any other charges, if any ( c ) , any other charges, if any ( d ) ...

Punjab State Power Corporation Limited - Punjab

29399515 routine maintenance, breakdown mtc., preventive mtc. and overhauling jobs of various mechanical auxiliaries such as hydrogen gas plant, dm plant, water based fire fighting system complete with fire fighting pumps, air compressors, self cleaning filter’s of acw, plate heat exchangers of dm cooling water, raw water pumps, service water pumps, aph wash pumps, sludge disposal pumps, re claimation pumps, chemical dozing pumps, acid/alkali handling pumps, potable water pumps and misc. horizontal/vertical/ submersible sump pumps. various pumps & auxiliaries installed at hydrogen gas plant, pre treatment plant, water clarification plant, effluent treatment plant, ash water recovery system, raw water chlorination & cw chlorination system. concerned eot/hot cranes/hoists. all connected lp piping, nrvs & valves etc. including lp piping, nrvs & valves etc. before suction & after discharge valve of cw, bacw, tacw, hot well make up, stator water make up, boiler fill, acw, sgdmcw, tgdmcw and tg cycle make up pumps. operation and maintenance of mechanical workshop & plant drainage sump pumps installed at sump pump no. 1&2, of 2x210 mw stage i & 2x250 mw stage ii, ghtp, lehra mohabbat, on lump sum basis...

Punjab State Power Corporation Limited - Punjab

28732281 breakdown preventive mtc and overhauling of dm plants dg sets compressors hydrogen gas plants fire protection system ac system and other allied mech auxiliaries of stage iiand iii for 4 units bhel make 210 mw each and work of central mech workshop breakdown preventive mtc and overhauling of dm plants dg sets compressors hydrogen gas plants fire protection system ac system and other allied mech auxiliaries of stageii and iii for 4 units bhel make 210 mw each and work of central mech workshop...

Punjab State Power Corporation Limited - Punjab

28673178 breakdown preventive mtc and overhauling of dm plants dg sets compressors hydrogen gas plants fire protection system ac system and other allied mech auxiliaries of stage iiand iii for 4 units bhel make 210 mw each and work of central mech workshop breakdown preventive mtc and overhauling of dm plants dg sets compressors hydrogen gas plants fire protection system ac system and other allied mech auxiliaries of stageii and iii for 4 units bhel make 210 mw each and work of central mech workshop...

National Fertilizers Limited - Punjab

27270932 nfb/pur/sa/200075 two loop powered gas detectors , instrumentation items , two wire loop powered ammonia gas detector complete unit for hazardous area with following or better specifications gas sensor module type electrochemical , gas ammonia , ran ge 0 to 100 ppm ammonia , response time 50 percent full scale in less than 15 sec , transmitter with display unit explosion proof design , local display backlit lcd display , operation voltage 24vdc , user input switch on display panel , output linear 4 to 20 ma output , hart enable ( optional ) , error less than 2 percent of urv , approvals fm/csa/atex/iecex/ccoe , classification explosion proof , rating ip64 or better , operating temperature between 20 to 50 degc , cable entry 1/2 inch npt ( f ) , mounting bracket , cable glands , plugs & other accessories required for installation & calibration of detector . item code: 8080879 . , three wire loop powered hydrocarbon gas detector complete unit for hazardous area with following or better specifications gas sensor module type catalytic , gas hydrocarbon , range 0 to 100 percent lel standard , response time 50 percent full scale in less than 15 sec within 100 percent lel applied , transmitter with display unit explosion proof design , local display backlit lcd display , operation voltage 24vdc , user input switch on display panel , output linear 4 to 20 ma output , hart enable ( optional ) , error less than 2 percent of urv , approvals fm/csa/atex/iecex/ccoe , classification explosion proof , rating ip64 or better , operating temperature between 20 to 50 degc , cable entry 1/2 inch npt ( f ) , mounting bracket , cable glands , plugs & other accessories required for installation & calibration of detector . item code: 8080950 . , three wire loop powered hydrogen gas detector complete unit for hazardous area with following or better specifications gas sensor module type catalytic , gas hydrogen , range 0 to 100 percent lel standard , response time 50 percent full scale in less than 15 sec within 100 percent lel applied , transmitter with display unit explosion proof design , local display backlit lcd display , operation voltage 24vdc , user input switch on display panel , output linear 4 to 20 ma output , hart enable ( optional ) , error less than 2 percent of urv , approvals fm/csa/atex/iecex/ccoe , classification explosion proof , rating ip64 or better , operating temperature between 20 to 50 degc , cable entry 1/2 inch npt ( f ) , mounting bracket , cable glands , plugs & other accessories required for installation & calibration of detector . item code: 8080951 . , two wire loop powered co gas detector complete unit for hazardous area with following or better specifications gas sensor module type electrochemical , gas co , range 0 to 100 ppm co , response time 50 percent full scale in less than 15 sec , transmitter with display unit explosion proof design , local display backlit lcd display , operation voltage 24vdc , user input switch on display panel , output linear 4 to 20 ma output , hart enable ( optional ) , error less than 2 percent of urv , approvals fm/csa/atex/iecex/ccoe , classification explosion proof , rating ip64 or better , operating temperature between 20 to 50 degc , cable entry 1/2 inch npt ( f ) , mounting bracket , cable glands , plugs & other accessories required for installation & calibration of detector . item code: 8080952 . , two wire loop powered chlorine detector complete unit for hazardous area with following or better specifications gas sensor module type electrochemical , gas chlorine , range 0 to 5 ppm chlorine , response time 50 percent full scale in less than 15 sec , transmitter with display unit explosion proof design , local display backlit lcd display , operation voltage 24vdc , user input switch on display panel , output linear 4 to 20 ma output , hart enable ( optional ) , error less than 2 percent of urv , approvals fm/csa/atex/iecex/ccoe , classification explosion proof , rating ip64 or better , operating temperature between 20 to 50 degc , cable entry 1/2 inch npt ( f ) , mounting bracket , cable glands , plugs & other accessories required for installation & calibration of detector . item code: 8080953 . ...

National Fertilizers Limited - Punjab

27023885 nfb / pur / sa / 200075 two loop powered gas detectors , instrumentation items , two wire loop powered ammonia gas detector complete unit for hazardous area with following or better specifications gas sensor module type electrochemical , gas ammonia , ran ge 0 to 100 ppm ammonia , response time 50 percent full scale in less than 15 sec , transmitter with display unit explosion proof design , local display backlit lcd display , operation voltage 24vdc , user input switch on display panel , output linear 4 to 20 ma output , hart enable ( optional ) , error less than 2 percent of urv , approvals fm / csa / atex / iecex / ccoe , classification explosion proof , rating ip64 or better , operating temperature between 20 to 50 degc , cable entry 1 / 2 inch npt ( f ) , mounting bracket , cable glands , plugs & other accessories required for installation & calibration of detector . item code: 8080879 . , three wire loop powered hydrocarbon gas detector complete unit for hazardous area with following or better specifications gas sensor module type catalytic , gas hydrocarbon , range 0 to 100 percent lel standard , response time 50 percent full scale in less than 15 sec within 100 percent lel applied , transmitter with display unit explosion proof design , local display backlit lcd display , operation voltage 24vdc , user input switch on display panel , output linear 4 to 20 ma output , hart enable ( optional ) , error less than 2 percent of urv , approvals fm / csa / atex / iecex / ccoe , classification explosion proof , rating ip64 or better , operating temperature between 20 to 50 degc , cable entry 1 / 2 inch npt ( f ) , mounting bracket , cable glands , plugs & other accessories required for installation & calibration of detector . item code: 8080950 . , three wire loop powered hydrogen gas detector complete unit for hazardous area with following or better specifications gas sensor module type catalytic , gas hydrogen , range 0 to 100 percent lel standard , response time 50 percent full scale in less than 15 sec within 100 percent lel applied , transmitter with display unit explosion proof design , local display backlit lcd display , operation voltage 24vdc , user input switch on display panel , output linear 4 to 20 ma output , hart enable ( optional ) , error less than 2 percent of urv , approvals fm / csa / atex / iecex / ccoe , classification explosion proof , rating ip64 or better , operating temperature between 20 to 50 degc , cable entry 1 / 2 inch npt ( f ) , mounting bracket , cable glands , plugs & other accessories required for installation & calibration of detector . item code: 8080951 . , two wire loop powered co gas detector complete unit for hazardous area with following or better specifications gas sensor module type electrochemical , gas co , range 0 to 100 ppm co , response time 50 percent full scale in less than 15 sec , transmitter with display unit explosion proof design , local display backlit lcd display , operation voltage 24vdc , user input switch on display panel , output linear 4 to 20 ma output , hart enable ( optional ) , error less than 2 percent of urv , approvals fm / csa / atex / iecex / ccoe , classification explosion proof , rating ip64 or better , operating temperature between 20 to 50 degc , cable entry 1 / 2 inch npt ( f ) , mounting bracket , cable glands , plugs & other accessories required for installation & calibration of detector . item code: 8080952 . , two wire loop powered chlorine detector complete unit for hazardous area with following or better specifications gas sensor module type electrochemical , gas chlorine , range 0 to 5 ppm chlorine , response time 50 percent full scale in less than 15 sec , transmitter with display unit explosion proof design , local display backlit lcd display , operation voltage 24vdc , user input switch on display panel , output linear 4 to 20 ma output , hart enable ( optional ) , error less than 2 percent of urv , approvals fm / csa / atex / iecex / ccoe , classification explosion proof , rating ip64 or better , operating temperature between 20 to 50 degc , cable entry 1 / 2 inch npt ( f ) , mounting bracket , cable glands , plugs & other accessories required for installation & calibration of detector . item code: 8080953 ....

Punjab State Power Corporation Limited - Punjab

24916257 routine , breakdown preventive mtc . and overhauling jobs of various mechanical auxiliaries comprising of hydrogen gas plant , dm plant , fire fighting system , vertical and horizontal pumps , air compressors , etc . , connected lp piping valves , operation maintenance of mechanical workshop and plant drainage pumps of ghtp stage i and ii , on lump sum basis for a period of one year . ...

Punjab State Power Corporation Limited - Punjab

24826152 breakdown preventive mtc and overhauling of dm plants dg sets compressors hydrogen gas plants fire protection system ac system and other allied mech auxiliaries of stage ii and iii for 4 units bhel make 210 mw each and work of central mech workshop...

National Fertilizers Limited - Punjab

24380445 gas clean moisture filter , electrical items : , process gas clean moisture filermake: agillent technology part no . of filter:cp17971pservice:installed on carier gas to gas chromatographs ( ae 1002 & ae 1013 ) to absorb moisture in hydrogen gas component to be filterd: moisture in hydrogen gas . qty=10nos...

Punjab State Co-Op Supply And Mktg Fed Ltd - Punjab

23798435 supply of testing of equipment testing of equipment under factories act ( incldg. hydraulic testing ) ammonia compressors with headers, ammonia accumulator vessel with coils, ammonia receivers (1.7m³ & 1.3 m³), ammonia oil separators, air receiver 6.2 m³, air receiver 500 ltrs., hydrogen gas holder 2.9 m³, spherical heat exchanger, auto claves, holding vessel, hydrogen surge vessel, heating column, caustic lye tank, lifting equipments (1,2,3 & 5 ton), thermopack, valves, pipe holders 2”,3”,4”, 6” (thermic fluid 200, air 100, ammonia 150”), hydrogen pipe holders, 1000 kva transformer crompton make, l.t. panel, 500 kva transformer emco make, l.t. panel, l.t. panel, d.g. set 187.5 kva kirloskar make, d.g. set 250 kva, ammonia section, packing section, pump house, v.p. plant, water treatment section, thermic boiler, cvl boiler...

Punjab State Power Corporation Limited - Punjab

21050080 tender for breakdown/preventive mtc. & overhauling of dm plants, d.g. sets, compressors, hydrogen gas plants, fire protection system, ac system and other allied mechanical auxiliaries of stage ii and iii for 4 units bhel make 210 mw each and work of central mechanical workshop at ggsstp, rupnagar....

Punjab State Power Corporation Limited - Punjab

20808613 tender for routine, breakdown & preventive mtc. and overhauling jobs of various mechanical auxiliaries comprising of hydrogen gas plant, dm plant, fire fighting system, vertical & horizontal pumps, air compressors etc., connected lp piping 8 valves, operation & maintenance of mechanical workshop and plant drainage pumps of 2x21 0 mw & 2x250 mw ghtp stage i & il, on lump sum basis for a neriod of one year....

Punjab State Power Corporation Limited - Punjab

20775693 routine, breakdown & preventive mtc. and overhauling jobs of various mechanical auxiliaries comprising of hydrogen gas plant, dm plant, fire fighting system, vertical & horizontal pumps, air compressors, etc., connected lp piping & valves, operation & maintenance of mechanical workshop and plant drainage pumps of 2x210 mw & 2x250 mw ghtp stage i & ii, on lump sum basis for a period of one year....

Markfed - Punjab

18844322 supply of tin containers plain and printed, poly mats and packets, corrugated boxes, pet bottles, pouch film, hydrogen gas cylinder, rice straw, duster, aluminum flex disk, gi plate stitching wire, metal marking ink, polyester filter cloth, vitamin a and d for trees, ammonia gas cylinder...