Military Engineer Services - Punjab

40845501 tender for special repair / replacement of e / m plants and machineries at af station bhisiana; 1 supply installation , comissioning and testing of ( pump set with suitable capacity 3 ph motor ) horizontal split casing type capable of delivering 125 m3 hr at60 mtr head directly coupled with suitable capacity of electric motor 3 phase 415v 1440rpm rating as per the recommendation of manufacture of pump set, suitable new foundation same size as per oem recommendation providing new rccfoundation ( minimum height of foundation from gl 01 mtr ) , base plate made from 6 mm thick ironplate / angel suitable size as per oem recommendation pump frame , iron angles frame , anti vibration pad , nut bolts washer for holding to pump with motor , with 0 vibration of pump set, including necessery electrical connection and water connectionout let / inlet water suply pipe ci / di / ms pipe testing complete, as directed by eng in charge. pcc 1:2:4 type b 1 with 20 mm grade stone aggregate foundation bolts, nuts washer etc of suitable size, complete all as specified and directed. note 1: the cost shall be included suitable arrangement of crane to installation of new pump in 09 meter depth of sewage well and lifting of old from existing location.note 2 : the cost shall be included of dismantling and reconnecting of existing all electrical and water pipe line connection with all fittings into pump and motor. 2 supply installation , comissioning and testing of ( pump set with sitable capacity 3 ph motor ) pump set horizontal split casing non clog type capable of delivering 125 m3 hr at40 mtr head directly coupled with suitable capacity of electric motor 3 phase 415v 1440rpm rating as per the recommendation of manufacture of pump set, suitable new foundation in ( 09 mtr depth of sewage well ) same size as per oem recommendation providing new rccfoundation minimum height for foundation from base 01 metre , base plate made from 6 mm thick ironplate / angel suitable size as per oem recommendation pump frame, iron angles frame, anti vibration pad , nut bolts washer for holding to pump with motor, with 0 vibration of pump set, including necessery electrical connection and water connectionout let / inlet water suply pipe ci / di / ms pipe testing complete.as existing and as directed by eng in charge. pcc 1:2:4 type b 1 with 20 mm grade stone aggregate foundation bolts, nuts washer etc of suitable sizecomplete all as specified and directed. ( 1 pump sewage no ii ) note 1: the cost shall be included suitable arrangemen of equipment or crane to installation of new pump in 09 mtr depth of sewage well and lifting of old pump from existing location.note 2: the cost shall be included of dismantling and reconnecting of existing all electrical and water pipe line connection with all fittings into pump and motor. 3 supply installation , connecting comissioning and testing of pump setcentrifugal type ( horizantal multistage type ) 70 m3 at 40 mtr head with electric motor3 phase 415 volts, 50 c / s 1440 rpm of rating as per the recommendation of manufacturer of pump set, suitable capacity new foundation same size as per oem recommendation providing new rccfoundation, base plate made from 6 mm thick ironplate / angel suitable size as per oem recommendation pump frame, iron angles frame , anti vibration pad , nut bolts washer for holding to pump with motor , with 0 vibration of pump set, including necessery electrical connection and water connection out let / inlet water suply pipe ci / di / ms pipe testing complete.as existing and as directed by eng in charge. pcc 1:2:4 type b 1 with 20 mm grade stone aggregate foundation bolts, nuts washer etc of suitable size, complete all as specified and directed. ( 02 nos level tank ) note 1: the pump and motor should be multi stage type.note 2: the cost shall be included of dismantling and reconnecting of existing all electrical and water pipe line connection with all fittings into pump and motor. 4 supply installation , connecting comissioning and testing of pump setcentrifugal type ( horizantal split case non clogtype ) 50m3 / hr at 30 mtr head with electric motor3 phase 415 volts, 50 c / s 1450 rpm of rating as per the recommendation of manufacture of pump set, suitable capacity new foundation same size as per oem recommendation providing new rccfoundation, base plate made from 6 mm thick ironplate / angel suitable size as per oem recommendation pump frame , iron angles frame , anti vibration pad , nut bolts washer for holding to pump with motor , with 0 vibration of pump set, including necessery electrical connection and water connection outlet / inlet water suply pipe ci / di / ms pipe testing complete as existing and as directed by eng in charge. pcc 1:2:4 type b 1 with 20 mm grade stone aggregate foundation bolts, nuts, washer etc of suitable sizecomplete all as specified and directed.04 nos ( sewage 03, backwash 01 ) note 1 : the pump and motor should be split case type.note 2: the cost shall be included of dismantling and reconnecting of existing all electrical and water pipe line connection with all fittings into pump and motor. 5 supply installation , connecting comissioning and testing of ( pump set with sitable capacity 3 ph motor ) pump set of monoblock pump set suitable for 415 v , 3phase system having capacity 5 hp at 30 mtrhead with electric motor3 phase 415 volts, 50 c / s , 1500 rpm of rating as per the recommendation of manufacture of pump set, suitable capacity new foundation same size as per oem recommendation providing new rccfoundation, base plate made from 6 mm thick ironplate / angel suitable size as per oemrecommendation pump frame, iron angles frame, anti vibration pad, nut, bolts, washers for holding to pump with motor, with 0 vibration of pump set, including necessery electrical connection and water connection outlet / inlet water suply pipe ci / di / ms pipe testing completeas existing and as directed by eng in charge. pcc 1:2:4 type b 1 with 20 mm grade stone aggregate foundation bolts, nuts washer etc of suitable size, complete all as specified and directed. ( lorry filling 02 trop 01 ) note : the cost shall be included of dismantling and reconnecting of existing all electrical and water pipe line connection with all fittings into pump and motor. 6 supply installation, connecting comissioning and testing of pump set with suitable capacity motor of monoblock pump set suitable for 415 v , 3phase system having capacity 525 lpm , 18 24 mtr head . with electric motor3 phase 415 volts, 50 c / s , 2830 of rating as per the recommendation of manufacture of pump set, with trolly mounted havingrubber tyre alonwith tube & steel rimmake mrf, pump will have trolly mounted having rim size 14 inch, section width 165 mm.size of tyre 40cm x 40 cm x 14cm, tread depth of tyre 8.5 mm, menimum weight 7 kg, make mrf / ceat. the wheel will have rubber tyre alonwith tube & steel rim, nut bolt, washer etc. the wheel with suitable size bearing both wheelwill be fixes in trolly with axle , the axlce made of 65 mm dia heavy grade steel pipe , minimum length of axle 1.5 mtr, support angel iron frame made of 6 mm thick iron plate, duly painted with two coat of stove enamel paint which is capable to carry the load of monoblock pump , andpulling arrangemnt, vibration pad, nut bolts washer for holding to pump with motor, with 0 vibration of pump set, including necessery water connectioninlet / out let, testing complete.as existing and as directed by eng in charge. having arrangement ofsuitable capacity dolstarter mounted on trollyand frame having plate / angeland amp meter, voltmert, single phase preventopr, dry run protection, relay, tripping on / off indicator button, iron angles frame, anti vibration pad, nut bolts washer for holding to pump with motor and water connectioninlet / outlet testing complete as existing and as directed by eng in charge. ( trolly mounted 01 ) 7 supply installation , connecting comissioning and testing of pump set with suitable capacity motorof monoblock pump set suitable for 415 v , 3phase system having capacity 405 lpm , 12 18 mtr head . with electric motor3 phase 415 volts, 50 c / s , 2830 of rating as per the recommendation of manufacture of pump set, with trolly mounted having 400 mm dia wheel withofrubber tyre alonwith tube & steel rimmake mrf , pump will have trolly mounted having rim size 14 inch , section width 165 mm.size of tyre 40cm x 40 cm x 14cm, tread depth of tyre 8.5 mm, menimum weight 7 kg , make mrf / ceat .the wheel will have rubber tyre alonwith tube & steel rim , nut bolt , washer etc, , the wheel with suitable size bearing both wheelwill be fixes in trolly with axle , the axlce made of 65 mm dia heavy grade steel pipe , minimum length of axle 1.5 mtr , support angel iron frame made of 6 mm thick iron plate, duly painted with two coat of stove enamel paint which is capable to carry the load of monoblock pump , andpulling arrangemnt , , vibration pad , nut bolts washer for holding to pump with motor , with 0 vibration of pump set, including necessery water connectioninlet / out let, testing complete.as existing and as directed by eng in charge.make kirloskar / cg / jyoti, suitable mounting arrangement on trolly fordolstarter given in schedule , nut bolts washer for holding to pump with motor water connectioninlet / out let, testing complete.as existing and as directed by eng in charge.make kirloskar / cg / grundfoss ) / jyoti. all as directed and specified by engr in charge ( trolly mounted 04 ) 8 supply installation, comissioning and testing of pump set with suitable capacity motor of monoblock pump setde watering type having sludge handling capacity 7 mm suitable for 415 v, 3 phase system having capacity 295 lpm , 11 mtr head, with electric motor 3 phase 415 volts, 50 c / s, 2830 of rating as per the recommendation of manufacturer of pump set, pump set, with trolly mounted having 400 mm dia wheel withofrubber tyre alonwith tube & steel rimmake mrf , pump will have trolly mounted having rim size 14 inch, section width 165 mm.size of tyre 40cm x 40 cm x 14cm, tread depth of tyre 8.5 mm, menimum weight 7 kgmake mrf / ceat. the wheel will have rubber tyre alonwith tube & steel rim , nut bolt , washer etc, , the wheel with suitable size bearing both wheelwill be fixes in trolly with axle , the axlce made of 65 mm dia heavy grade steel pipe , minimum length of axle 1.5 mtr , support angel iron frame made of 6 mm thick iron plate, duly painted with two coat of stove enamel paint which is capable to carry the load of monoblock pump , andpulling arrangemnt, vibration pad, nut bolts washer for holding to pump with motor , with 0 vibration of pump set, including necessery water connectioninlet / outlettesting complete as existing and as directed by eng in charge.having suitable mounting arrangement on trolly fordolstarter given in schedule, nut bolts washer for holding to pump with motor water connectioninlet / outlet testing, complete all as specified and directed. ( trolly mounted 03 ) 9 supply testing, commisioning of pumping sets centrifugal type, ic engine driven complete ( 12 bhp ) air clooled 1500 rpm, inclusive fuel tank 20 ltr capacity, maintenance free battery 12 volt 01 no, in build self starter 01, and additional of manually hand operated axial drive arrangemnt. the diesel driven pump will have trolly mounted having rim size 14 inch, section width 165 mmsize of tyre 40cm x 40 cm x 14cm, tread depth of tyre 8.5 mm, minimum weight 7 kg, make mrf / ceat. the wheel will have rubber tyre alonwith tube & steel rim, nut bolt, washer etc. the wheel with suitable size bearing both wheelwill be fixes in trolly with axle , the axlce made of 65 mm dia heavy grade steel pipe, minimum length of axle 1.5 mtr, support angel iron frame made of 6 mm thcik iron plate, duly painted with two coat of stove enamel paint which is capable to carry the load of ic engine with centrifugal pump and pulling arrangemnt, vibration pad, nut bolts, washer for holding to pump with motor, with 0 vibration of pump set including necessery water connectioninlet / outlet testing completeas existing and as directed by eng in charge. 10 supply & fixing of hose pipe63 mm dia, 36 metres long complete as per is 884 985 including pre fitted both ends flanges made of stainles steel, complete all as specified and directed. 11 supply and fix garden irrigation green hose pipe isi mark pvc material with fibre reinforce 40 mm bore including suitable metal clamps with nut and bolts. the cost shall be included fixing of clamp, nut bolt, flage, rubber gasket etc with plastic 40 mm dia foot valve for suction pipe, complete all as specified and directed. 12 supply, install, testing and commissioning of twin lobe, roots type air blowers with motor of designed capacity and head ( 1050 cum / hr. of free air at 0.65 kg / cm2, or as required ) driven through v belt or directly coupled through flexible coupling to a tefc motor of suitable hp 7.5 phase supply, 415v, 50 cycles and complete in respect along with necassary connection to air grid, air flow meters, silencers, pressure release valves, butterfly valve nrvs, etc as shown in drawing, complete all as specified and directed.air blowers :moc : cast irontype : oil free positive displacement screw typecapacity m3 / hr @ 6000 mm wc : 1050air quality : class o [ 100% oil free air ] drive : directnoise level : < 77+ / 3 db ( a ) note: cost quoted to be inclusive of foundation and fixing of equipment to the foundation by means of base plate, grouting bolt etc.foundation shall be of pcc 1:3:6 at least450 mm above floor width of foundation shall be sufficient to give 100 mm clearance on both side of equipment. 13 takng down unserviceable air grid made of gi / ci pipe and filter media from all 03 beds and deposit out side of bed and clean filter media with fresh water and again filling of same filter media after cleaningfilter bed andsupply, install, testing and commissioning ofnew air gridfrom air blower to all 03 beds of coarse bubble, lateral & header type in medium grade ( ss304pipe 65 mm bore with frp coated 3mm thick ) construction for filter bed cap 20000 gln / hr . non clog type air dispersion system capable 3 5 cfm of air or as required with oxygen transfer efficiency of 5 6% per / meter water depth, fine bubble membrane diffusers complete in all respect with fittings, valve and suitable nrv will be fixed in air line which is capable to release the blower air and stopping sand and mud to re enter into the air pipe liner, support, clamps and accessories complete all as shown in drawings. air grid when being fed by air blower of 1050 cum / hr capacity should supply minimum following qty of air, filter bed 03 nos. note : contractor shall be required to submit air grid drawings within 30 days of placement of work order. design of air grid to be approved by accepting officer before execution. air grid to be made of ss 304 frp coated.note : the cost shall be includedss 304 pipe and fitting along with prp coating 3mm thick. 14 taking out the existing pump and motor from the base plate of capacity 40 30 hp and deposit to mes storeincluding disconnecting the existingelectrical connection, suction and delivery line including earthwork and dismantling / demolition / breaking the existing rcc / pccfoundation at main main pump house / sewage pump in depth of 09 meters from ground level, complete all as specified and directed.note the cost shall be included making good disturbed surface as same as existing using pcc 1:2:4 and cement wash. the cost shall also included removing demolition materilal obtaining from old structure and deposited 500 mtr away from pump house. the contractorwill check the site and will take measurement of existing foundation i.e. length, width, height , nut , bolt size, base frame etc. before quoting of tenderand take measurement of existing pump with motor foundation. 15 taking out the existing pumpand motor from the base plate ofcapacity 10 20 hp and deposit to mes storeincluding disconnecting the existingelectrical connection, suction and delivery line including earthwork and dismantling / demolition / breaking the existing rcc / pccfoundationat main pump house / sewage pump in depth of 09 meters from ground level, complete all as specified and directed.note the cost shall be included making good disturbed surface as same as existing using pcc 1:2:4 and cement wash. the cost shall also included removing demolition material obtaining from old structure and deposited 500 mtr away from pump house . the contractorwill check the site and will take measurement of existing foundation i.e. length, width, height , nut , bolt size , base frame etc. before quoting of tenderand take measurement of existing pump with motor foundation. 16 taking out the existing pumpand motor from the base plate ofcapacity 1 5 hp and deposit to mes storeincluding disconnecting the existingelectrical connection, suction and delivery line including earthwork and dismantling / demolition / breaking the existing rcc / pccfoundationat main pump house, complete all as specified and directed.note the cost shall be included making good disturbed surface as same as existing using pcc 1:2:4 and cement wash. the cost shall also included removing demolition material obtaining from old structure and deposited 500 mtr away from pump house . the contractorwill check the site and will take measurement of existing foundation i.e. length, width, height, nut, bolt size, base frame etc. before quoting of tenderand take measurement of existing pump with motor foundation. 17 supply, installation, testing and commissioning of chloronome plant brine based suitable for hypo strength 6 8 gpl, chlorine producingto generate 500 g / hr, salt requirement 2.12 kg / hr, water consumption 70 lph, 415 volt, 3 ph 50 hz of water per day at 2 ppm dose and capable of producing actual chlorine generated 500 kg / hr of available chlorine in the form of sodium hypochloride continous strength 0.7 to 0.8 % electrolyser will be bipolar and cathode & anode intitanium coated with mixed metal oxide and cell body is pvc with dosing pump ( 01 working and 01 standby ) mechanically actuated disphragam pump and electrolyser tank of min 500 ltrs capacity made of pvc internally and frp externally of vinyl ester resin and salt dosing tank of hdpe including supporting structure , 1mx1.5x1.2 mtr height made of fly as brick with cement mortar, 15 mm thick cement base plasterpipe lines network, pvc valve etc complete and comprehensivewarranty for 01 years for the entire unit / plant. note : the cost shall be included suitable cpacity of rectifier and electric cable, starter unit for dosing pump model no pcp 500, the cost shal be included following ( i ) inlet valve*01 no, ( ii ) inlet solenoid valve 01 no, ( iii ) manual valve at brine tank inlet 01 no, ( iv ) brine tank hdpe materila 500 lt cap 01 no, ( v ) level switch on brine tank 01 no, ( vi ) agitator01 no, ( vii ) brine tank drain valve 01 no, ( viii ) brine pump inlet / out let valve 01 no, ( ix ) strainer at brine pump suction 01 no, ( x ) brine pump 02 no, ( 1w+1s ) pump typediaphragm, pressure ratin of pump 2kg / cm2, ( xi ) acid inlet / outlet valves 02 no, acid tank 500 ltr with frp coated 01no, ( xii ) acid tank valves 03 no, ( xiv ) acidrecirculating pump 01 no, ( xv ) acid pump out let valve 01 no, ( xv ) starter cum control panel 01 no, control type relay based, power control 415 v 3 ph 50 hz make pristine water, industrial devices indian pvt ltd, chloro tech equipments pvt ltd, oximax water quality solutions ( xvi ) dc rectifier 01 no type oil / aircooled variac type, power input 415 v ac , 3 ph , 50 hz, out put 25 v dc, 130 a dc, piping and fitting as reqired oem recommendation, chloine test kit 02no. 18 ( a ) supply, install, testing and commissioning of hypo solution dosing pump / injector aquafit / supreme / earth water techonology or equivalent max pressure 8kg / cm square& max flow rate 07 ltr / hr 15 mtr headincluding all accessories such aslead tubing connecting ferrules check valves all as directed. note : the cost shall be included suitable foundation / stand to installation of dosing pump on treated water sump with follwing accessories : ( b ) preparation tank model aqua1005 of net capacity 170 ltrs frp dosing tank dia 650 x net height 375 + conical 300mm, gross height with stand 1000mm consisting of water inlet line, outlet with y strainer, drain, overflow, conical bottom of sludge deposition, pot hole with cover, level gauge ( i ) water inlet line ( ii ) out let with y strainer ( iii ) drain pipe / over flow pipe ( iv ) connecting bottom for sludge deposition ( v ) pot hole coveragitator 120 watt 900 rpm single phase flange mounted motor with plastic shaft and impeller; ( vii ) water inlet line ( viii ) outer with strainer ( ix ) drain pipe / over flow pipe ( c ) service tank model no. aqua1006 of net capacity 100 ltrs of frp dosing tank top dia 540mm x bottom dia 480mm x height 575mm consisting of water inlet line. dosing pump inlet arrangement, drain overflow, level gauge, inspection port ( i ) water inlet line ( ii ) outlet with y strainer ( iii ) drain pipe / over flow pipe ( iv ) provision of mounting pump on lid / wallagitator 120 watt 900 rpm single phase flange mounted motor with plastic shaft and impeller. 19 supply and fixingnrv ( non return valve of size 150 mm boreflanged and drilled ends ) complete, isi marked, including jointing material such as rubber gasket, bolts, nuts etc suitable for size 150 mm all as specified and as directed by eng in charge. 20 supply & fixing of strainer ytype conforming to is of size 150 mm dia flanged and drilled ends complete, isi marked including jointing material such as rubber gasket, bolts, nuts etc suitable for size 150 mm all as specified and as directed by eng in charge. 21 supply and fixing sluice valve, 150 mm pn 1.6 type flanged and drilled ends complete with brassspindle including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 150 mm, complete all as specified and directed. 22 supply and fixing sluice valve, 250 mm pn 1.6 type flanged and drilled ends complete with brassspindle including jointing material such as rubber gasket, bolts, nuts etc suitable for size 250 mm, complete all as specified and directed. 23 supply and fixing sluice valve, 350 mm pn 1.6 type flanged and drilled ends complete with brassspindle including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 350 mm, complete all as specified and directed. 24 supply and fixing sluice valve, 450 mm pn 1.6 type flanged and reducer for fixing sluice valve in 300 mm old ci pipe line, drilled ends complete, with brass spindle including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 450 mm, complete all as specified and directed.note : the cost shall be inluded reducer for fixing 450 mm sluice valve in 300 mm dia ci pipe line and 20 mtr long 25 mm dia solid iron rod handel wiht top edge t made of 450 mm wide.the valve shall be fitted in 18 mtr under ground sump .all lighting and tools and plant required to fix in sump in existing pipe wiht leak proof arrangemnt. 25 supply and fix foot valve conforming to is 4038, 150 mm dia flnged endand rubber gasket, leather jip andcomplete, with stainless steel nut bolt rust proof including jointing material such as rubber gasket etc suitable for size 150 mm, complete all as specified and directed. 26 supply and fix foot valve conforming to is 4038, 80 mm dia flnged endand rubber gasket , leather jip andcomplete, with stainless steel nut bolt rust proof, including jointing material such as rubber gasket etc suitable for size 80 mm, complete all as specified and directed. 27 supply and fixnrv pn 1.0 ( non return valve of size 250 mm boreflanged and drilled ends complete, isi marked including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 250 mm, complete all as specified and directed. 28 supply and fixnrv pn 1.6 ( non return valve of size 65 mm boreflanged and drilled ends complete, isi marked including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 65 mm, complete all as specified and directed. 29 supply and fixnrv pn 1.6 ( non return valve of size 80 mm boreflanged and drilled ends complete, isi marked including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 80 mm all as specified and as directed by eng in charge. 30 supply and fixnrv pn 1.6 ( non return valve of size 50 mm boreflanged and drilled ends complete, isi marked including jointing material such as rubber gasket, bolts, nuts, etc suitable for size 50 mm all as specified and as directed by eng in charge. 31 supply and fixgun metal, globe or gate valves 50 mm dia with iron wheel head, screwed both ends for iron pipe and supply fixed new one, complete all as specified and directed. 32 supply and fix foot valve conforming to is 4038, 50 mm dia flnged endand rubber gasket , leather jip andcomplete, with stainless steel nut bolt rust proof, including jointing material such as rubber gasket, , etc suitable for size 50 mm, complete all as specified and directed. 33 supply and fix sluice valve, 80 mm pn 1.6 type flanged and drilled ends complete, with stainless steel spindle including jointing material such as rubber gasket, bolts, nuts etc suitable for size 80 mm, complete all as specified and directed. 34 supply and fixgun metal globe or gate valves 65 mm dia with iron wheel head, screwed both ends for iron pipe and supply fixed new one, complete all as specified and directed. 35 supply and fix pressure gauge 100 mm dia with ball valve of pressure 25 kg / sqcm ( 40 hp 09, 30 hp 01, 20 hp 02, 10 hp 04, air blower 02 ) , complete all as specified and directed. 36 supply and fixgun metal, globe or gate valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and supply fixed new one, complete all as specified and directed. 37 supply and fixgun metal, globe or gate valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and supply fixed new one, complete all as specified and directed. 38 supply and fix ms erw pipe nominal dia 350 mm as per is 3589 ( 1981 ) thickness 6.0 mm, including specialfittings , joints complete for deliveryandside including necessarynutsbolts and rubber etc, all as specified and directed. note :the cost shall be inclusive for making header for connection of varios sizes of ms / di / gi pipe line for delivery includingwelding, bending work. 39 supply and fix ms erw pipe nominal dia 150 mm as per is 3589 ( 1981 ) thickness 6.0 mm, including specialjoints complete for deliveryandside including necessarynutsbolts and rubber etc, all as specified and directed for, complete all as specified and directed. note :the cost shall beinclusive for making header for connection of varios sizes of ms / di / gi pipe line for delivery includingwelding, bending work . 40 supply and laying 100 mm bores of tubes medium grade galvanised with all fittings and fixed, complete laid in trenches, complete all as specified and directed. 41 supply and laying 80 mm bores of tubes medium grade galvanised with all fittings and fixed complete laid in trenches, complete all as specified and directed. 42 supply and laying 50 mm bores of tubes medium grade galvanised with all fittings and fixed complete laid in trenches, complete all as specified and directed. 43 supply and laying 20 mm bores of tubes medium grade galvanised with all fittings and fixed complete laid in trenches, complete all as specified and directed. 44 supply and laying 25 mm bores of tubes medium grade galvanised with all fittings and fixed complete laid in trenches, complete all as specified and directed. 45 supply and fix ci fittingsflanged end up to 200 mm to 300 mm dia bore such as bends ( any type radious and angle ) tapers any type , ( straight, bens increasing, decreasing or double socket etc ) tee places single branch, y junction, double branch, cross ( all sockets or socket and spigot ) collars caps and plugs, mechanicla joints suitable for 150 / 80 / 100 mm pipe, complete all as specified and directed. note :the cost shall be included for nut bolt any size and length rquire to fix , joint of ms pipe and joint, elbow, tee, bend, flanged or existing pipe suction and delivery. 46 supply and fix ci fittingsflanged end up to 150 mm dia bore such as bends ( any type radious and angle ) tapers any type , ( straight, bens increasing, decreasing or double socket etc ) tee places single branch , y junction , double branch , cross ( all sockets or socket and spigot ) collars caps and plugs, mechanicla joints suitable for 150 / 80 / 100 mm pipe, complete all as specified and directed.note :the cost shall be included for nut bolt any size and length rquire to fix, joint of ms pipe and joint , elbow , tee, bend , flanged ro existing pipe suction and delivery. 47 taking down u / s & supply and fix new electirc control panel ( cpri approved ) for pumping sets, cubical type, for in door typeuse, floor mounted, factory fobricated, dust, weather & vermin proof, powder coated, made out of crca sheet of 2.00 mm thick and angle iron legs of size 50 mm x 50mm x 5mm with front openable with locking arrangements, shutters for each mccb / starters having hinges on one side and locating knobs press type on other side and rear openable door complete with fully enclosed bus bar chamber, having insulated bus bar made out of aluminium strips of rating 800 amps for 3 phase & nutral415 volts, 50 c / s 4 wire system, with cable entry provision completeall as specified and including suitable pcc work as per recommended by manufacturer equipped with the following items: note : ( 1 ) the cost of pcc foundation shall be deemed to be included in this item rate. ( new pump house stand by ) 2. the item will be deposit in e / m store ( main pump house ) ( a ) incoming: ( i ) mccb, 4 pole, 415 volt of rating 400 amps, 36 ka 01 no. ( i / c ) ( a ) outgoing ( i ) mccb, 4 pole, 415 volt of rating 125 amps, 25 ka 09 no. in each starter, ) ( ii ) volt meter, digital type0 500 volts with selector switch 1no. ( each starter ) ( iii ) amp meter digital type 0 150 amps, ct operated with cts and selector 09 set ( iv ) indicator lamp suitable for indicationof 3 phases 01 set of three ( v ) separate enclosure for each fully automatic star delta starter heavy dutystandard model incorporating heavy duty 4 pole contactor type dc1 dx overload typelr3d / lr1d auto start switch 3 position selector switch for spp auto spp / manual / manual voltmeter with selector switch, suppressed scale, motor on & trip led indicator star delta timer forcentrifugal pumping set 09 nos relay range 48 57 note : the each starter should have separate steel body enclosure in separate compartment for each pump total starter qty 09 nos. ( vi ) single phasing, over load, phase reversal, under volatage, dry run protection unit 09 nos. 48 taking down u / s & supply and fix new electirc control panel ( cpri approved ) for pumping sets, cubical type, for in door typeuse, floor mounted, factory fobricated, dust, weather & vermin proof, powder coated, made out of crca sheet of 2.00 mm thick and angle iron legs of size 50 mm x 50mm x 5mm with front openable with locking arrangements, shutters for each mccb / starters having hinges on one side and locating knobs press type on other side and rear openable door complete with fully enclosed bus bar chamber, having insulated bus bar made out of aluminium strips of rating 250 amps for 3 phase & nutral415 volts, 50 c / s 4 wire system, with cable entry provision completeall as specified and including suitable pcc work as per recommended by manufacturer equipped with the following items: note : the cost of pcc foundation shall be deemed to be included in this item rate. the item will be deposit in e / m store ( level tank ) ( a ) incoming: ( i ) mccb, 4 pole, 415 volt of rating 160 amps, 25 ka 01 no. ( a ) outgoing ( i ) mccb, 4 pole, 415 volt of rating 40 amps, 16 ka 03 no. pump 3, ( ii ) mccb, 4 pole, 415 volt of rating 25 amps, 16 ka 01 no. ( submersible 01 ) , ( iii ) volt meter, digital type0 500 volts with selector switch 01no. ( iv ) amp meter digital type 0 150 amps, ct operated with cts and selector 01 set ( v ) indicator lamp suitable for indicationof 3 phases 01 set of three 49 ( vi ) separate enclosure for each fully automatic star delta starter heavy dutystandard model incorporating heavy duty 4 pole contactor type dc1 dx overload typelr3d / lr1d auto start switch 3 position selector switch for spp auto spp / manual / manual voltmeter with selector switch, suppressed scale, motor on & trip led indicator star delta timer forcentrifugal pumping set 03 nos relay range 38 50, starter qty 01 nos.note : the each starter should have separate steel body enclosure in separate compartment for each pump total starter qty 03 nos. ( vii ) separate enclosure for each fully automatic dol starter heavy dutystandard model incorporating heavy duty 4 pole contactor type dc1 dx overload typelr3d, auto start switch 3 position selector switch for spp auto spp / manual / manual voltmeter with selector switch, dual analog, va meter, hour meterto monitor spcu , power on hour , motor on & trip led indicator , tp c curve mcb for short circuit protection forsumersiblepumping set 01 nos. relay range 18 25.note : the each starter should have separate steel body enclosure in separate compartment for each pump. ( vii ) single phasing, over load, phase reversal, under volatage, dry run protection unit 04 nos. 50 taking down u / s & supply and fix new electirc control panel ( cpri approved ) for pumping sets, cubical type, for in door typeuse, floor mounted, factory fobricated, dust, weather & vermin proof, powder coated, made out of crca sheet of 2.00 mm thick and angle iron legs of size 50 mm x 50mm x 5mm with front openable with locking arrangements, shutters for each mccb / starters having hinges on one side and locating knobs press type on other side and rear openable door complete with fully enclosed bus bar chamber, having insulated bus bar made out of aluminium strips of rating 120 amps for 3 phase & nutral415 volts, 50 c / s 4 wire system, with cable entry provision completeall as specified and including suitable pcc work as per recommended by manufacturer equipped with the following items: note : the cost of pcc foundation shall be deemed to be included in this item rate. ( new pump house stand by ) 2. the item will be deposit in e / m store ( air blower+ back wash ) ( a ) incoming: ( i ) mccb, 4 pole, 415 volt of rating 80 amps, 25 ka 01 no. ( a ) outgoing ( i ) mcb, 4 pole, 415 volt of rating 32 amps, 25 ka 04 nobackwash 2, air blower 02 ) ( ii ) mcb, 4 pole, 415 volt of rating 5 amps, 16 ka 01 no. ( foculator 04 ) ( iii ) volt meter, digital type0 500 volts with selector switch 01no. ( iv ) amp meter digital type 0 150 amps, ct operated with cts and selector 01 set ( v ) indicator lamp suitable for indicationof 3 phases 01 set of three ( vi ) single phasing, over load, phase reversal, under volatage, dry run protection unit 04 nos. ( vi ) separate enclosure for each fully automatic star delta starter heavy dutystandard model incorporating heavy duty 4 pole contactor type dc1 dx overload typelr3d / lr1d auto start switch 3 position selector switch for spp auto spp / manual / manual voltmeter with selector switch, suppressed scale, motor on & trip led indicator star delta timer forcentrifugal pumping set 02 nos. relay range 14 22.note : the each starter should have separate steel body enclosure in separate compartment for each pump total starter qty 02 nos. ( vii ) separate enclosure for each fully automatic star delta starter heavy dutystandard model incorporating heavy duty 4 pole contactor type dc1 dx overload typelr3d / lr1d auto start switch 3 position selector switch for spp auto spp / manual / manual voltmeter with selector switch, suppressed scale, motor on & trip led indicator star delta timer forair blower pumping set 02 nos. relay range 09 14.note : the each starter should have separate steel body enclosure in separate compartment for each pump total starter qty 02 nos. 51 supply and fixthree phase motor starterwith suitable arrangement for floor mountedthree phase dol starter ubical type, for indoordoor typeuse, floor mounted, factory fobricated, dust, weather & vermin proof, powder coated, made out of crca sheet of 2.15 mm thick and angle iron legs of size 50 mm x 50mm x 5mm with front openable with locking arrangementswith , incoporating heavy duty 4 pole contactor type tc1 dx overload relay type lr3d, auto start switch , 3 position slector switch for single phase preventer , auto / spp manual / manual ( as4 ) , on / off rocker switch, ryb led indicator, motor on&trip led indicator, dol in sheet steel enclosure suitable for capacity submersible pump with relay range 4 6 amps cat no be1spsddx204310 make c&s / mu g6 ( ss97756 ) l&t, scheinder or equivalent.note : the cost of pcc foundation shall be deemed to be included in this item rate. 52 supply and fixthree phase motor starterwith suitable arrangement for floor mountedthree phase dol starter ubical type, for indoordoor typeuse, floor mounted, factory fobricated, dust, weather & vermin proof, powder coated, made out of crca sheet of 2.15 mm thick and angle iron legs of size 50 mm x 50mm x 5mm with front openable with locking arrangementswith, incoporating heavy duty 4 pole contactor type tc1 dx overload relay type lr3d, auto start switch, 3 position slector switch for single phase preventer , auto / spp manual / manual ( as4 ) , on / off rocker switch, ryb led indicator, motor on&trip led indicator, dol in sheet steel enclosure suitable forcapacity submersible pump with relay range 2.5 4 amps at no be1spsddx204308 make c&s / mu g6 ( ss97756 ) l&t scheinder or equivalent.note : the cost of pcc foundation shall be deemed to be included in this item rate. ( 2 1hp 7 ) 53 supply and laying, pvc insulated and fr pvc round sheathed, copper conductor conforming to is: 694 pvc nsulated 1100 volt grade heavy duty electric cables with copper conductor, cross sectional area 35 sqmm 3 core all as specified and directed makehavells / anchor / polycab ) from mpcp to pump atmain pump house ) , level tank pump, sewage pump ) , complete all as specified and directed. 54 supply and laying , pvc insulated and fr pvc round sheathed, copper conductor conforming to is: 694 pvc nsulated 1100 volt grade heavy duty electric cables with copper conductor, cross sectional area 2.5 sqmm 3 core, complete all as specified and directed. ( db to dosing pump ) 55 supply and laying , pvc insulated and fr pvc round sheathed, copper conductor conforming to is: 694 pvc nsulated 1100 volt grade heavy duty electric cables with copper conductor, cross sectional area 16 sqmm 3 core, complete all as specified and directed. ( from panel to air blower, 30 hp sewage, 20 hp, 10 hp pump ) 56 s& f triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole mcb 32 amp ( dosing msachine ) , complete all as specified and directed. 57 material and labour for pcc 1:3:6, type c 1, using 20mm graded stone aggregate for road cutting / making plith for water storage tank / chemical dosing pump where required and fair finishing to exposed surfaces without using extra cement including necessary form work, complete all as specified and directed. 58 material and labour for brickworkwith fly ash bricksstraight or curved on plan exc 6 m mean radious built in including cement mortar 1:4 using sub class b bricks as in making wall / pillarsetc for support to ms erw pipe 300 / 150 mm dia, complete all as specified and directed. 59 supply and fix cpvc pipes sdr 11 & plain cpvc sdr 11 fittings in trenches / floors / ceiling complete including jointing and fixing accessories complete fittings such as ends, elbow, unions, reducing tee, adopetrs, sockets, plugs, hose clip laid in wall / trenches size 50 mm ( chlromes plant and dosing ) 60 x 2 nos for chloromes plant, complete all as specified and directed. 60 supply and fix cpvc ball valve ( brass insert ) size 50 mm dia as per requirement at site, complete all as specified and directed. ( chlrome plant ) 61 material and labour for fixing of chlorine test point of both outgoing line in cluding making holes in new lineand fixing of 25 mm dia gi pipe .5 mt longand butter fly valve 15bore, complete all as specified and directed. 62 taking down old unserviceable pvc water tank of any capacity and supply and fix new rotational moulded polythene water storage tank of capacity 500 ltr three layer ( cylindrical vertical with closed top ) in white colour and fix in position, complete all as specified and directed. ( main pump houise 04, sewage 01, mini 01, dosing 02, chlromes 01 ) 63 material & labour for sub main wiring ( concealed ) complete with two single core 6sq mm fr pvc insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non metallic pvc conduit and fittingsincluding 6 sq mm fr pvc insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing using machine cutting and making good the disturbed surface, complete all as specified and directed. note: 3 run of 6 sqmm & one run of pvc conduit shall be measured as single unit. 64 material and labour sheet metal enclosures for tpn dbs with double glazed door for incorporating mcbs, ip 43, 4 way with 415 amps rated busbar, 240 volts, as per is 8623, complete all as specified and directed. 65 supply and fixing 415 v 10 ka b curve miniature circuit breaker ( mcb ) of spn and current carrying capacity 16 32 amp, in the mcb dbcomplete with connection testing and commissioning, complete all as specified and directed. 66 supply and fixing mcb sp, 10 amps to 32 amps, c series, breaking capacity 10 ka, c curve 240 volts, 50 hz including necessary incoming and out going electric connection with suitable size of copper lugs etc, complete all as specified and directed. 67 surface excavation not exceeding 30 cm deep and averaging 10 cm deep and getting out in hard / dense soil, complete all as specified and directed. 68 supply and laying, lt ug xlpe insulated 1100 volt grade heavy duty electric cables with aluminium conductor , cross sectional area 240 sqmm 3.5 core, complete all as specified and directed. ( from existingpanel to proposed pnl ) for itemno 1 pump ) 69 supply and laying , lt ug xlpe insulated 1100 volt grade heavy duty electric cables with aluminium conductor , cross sectional area 150 sqmm 3.5 core, complete all as specified and directed. ( from change over to pumppanel ) 70 supply and laying , lt ug xlpe insulated 1100 volt grade heavy duty electric cables with aluminium conductor , cross sectional area 70 sqmm 3.5 core, complete all as specified and directed. ( from chlronoms plant ) 71 material and labour for point wiring surfaceon wallcomplete with fr pvc insulated unsheathed 1100 volts grade, conforming to is 694, 2.5 sq mm cable sizewith 2.5 sq mm earth continuity wire for one 3 pin socket outlet, 16 amps on independent board. ( nominal area ) multi stranded copper conductor cable drawn though in and including non metallic heavy grade rigid pvc conduit accessories, isi marked, 19 / 20 mm dia including all accessories, concealed in walls / floors / ceilings etc by cutting chases using machine and making good the disturbed surface, with and including suitable modular boxes, modular switch plates and 1.5 sq mm copper earth continuity wire connected to earth dolly complete for the following, complete all as specified and directed. 72 supply and fixing socket modular type 16 amps, 3 pin combine, 2 module, 240 volts, complete all as specified and directed. 73 supply and fixing switch modular type 16 amps, 1 module, 240 volts, complete all as specified and directed. 74 material and labour for earthing complete with galvanised steel steel earth plate electrode 600x600x6mm thick burried directly in ground ( earth pit not less than 2.25 mtrs deep below nominal ground level ) with top edge of the plate not less than 1.5 mtrs below nominal ground level connected to galvanised strip 25x4 mm by means of bolts, nuts, check nuts and washers of gi all as shown in electrical plate no 3 of ssr part i connected to earthing test point and testing on completion. all as specified and as directed. note: the cast of excavation and earth work pcc pit and pcc cover with handle, funnel & watering pipe, wiremesh, charcoal dust and common salt and earth strip up to 7.5 mtrs long shall be deemed included in the unit rate for earthing, complete all as specified and directed. 75 material and labour for earthing complete with galvanised steel plate electrode, 600 x 600 x 6.0 mm thick, buried directly in ground ( earth pit not less than 2.25 mtrs deep below nominal ground level ) with top edge of the plate not less than not less than 1.5 metres below nominal ground level connected to earthing lead of 4 mm dia galvanised iron or steel wire all as shown in ssr part i para no. 4 to the earthing test point all as specified and as directed.note : the cost of excavation and earth work pcc pit and ci cover funnel & watering pipe, wiremesh, charcoal dust and common salt shall be deemed included in the unit rate for earthing, complete all as specified and directed. 76 material and labour for making holes in 200 mm dia bore in rcc wall / sump using suitbale machinery or equipment and close agian using cement mortar 1:3:4 make or repair of pot holes in existing building wall / sump for passing of pipe / cables / pipe / cabletraynote: the distuebed surface of wall to passing of pipe cable / removing of existing ductshall be make good by applying cement plaster 1:4, and if required to fill with brick work 1:3:6 and applyinputty and colour wash etc matching with the existing surfaces, complete all as specified and directed. 77 material and labour for making holes in rcc partion wall intreated water tank and fixing of 450 mm dai di pipe given inschedule. thebore in rcc wall / sump using suitbale machinery or equipment and close agian using cement mortar 1:3:4 make or repair of pot holes in existing building wall / sump note: the distuebed surface of wall to passing of pipeshall be make good by applying cement plaster 1:4, and if required to fill with brick work 1:3:6 and applyingputty and colour wash etc matching with the existing surfaces, all as specified and dir by engr in charge 78 supply and laying pipe ductile iron, s / sincluding specials, class “k 9” 450 mm ( 18” ) dia . the pipe will be fixed in rcc wall fortreated water tank depth of 03 mtr alongwiht provision of 450 mm diasluice valve 450 mm will be fixed in which is given in schedule . the shall be included all fitting required to fix pipe in rcc / pcc wall, such assocket, mechnical joint, tail piece, flange, complete all as specified and directed. 79 supplying, fabricating and installing of following sizes of hot dip galvanized ladder type cable traysof size of 150 mm x 50mm x 1.6mm thick including horizontal vertical bends, reducers, tees, cross members and other accessories as required and duly installed from the ceiling / side walls with suitable sizes of channels / angles with anti corrosion painting, full threaded gl rods etc, complete all as specified and directed. 80 supply and fixfactory sealed300 mm bore flow water meter flanged end class a material brass item iso 406411 length500 mmisi markpipe with leak proof arrangementsite. the cost shall neincluded in quoted rate including all fittiings like socket, bend, elbow , rubber gasket, t taper end, flange , nut bolts , and end cap, mechanical jointe etc including all accessories required to installation of flow meterandpreventing of back flow water in existing lineetc & laying of the same under ground ior above ground as directed by engg in charge .note: the excavation and earth work also included in quoted rate . 81 taking up or down unserviceable gitubing and connection20 mm size, complete all as specified and directed. 82 taking down unserviceable di pipeof 150 mm diaincluding all fittings with spigot and socket ends and lead joints including burning out joints and recovering lead, complete all as specified and directed. 83 taling down unserviceable ci pipeof 300 mm diaincluding all fittings with spigot and socket ends and lead joints including burning out joints and recovering lead, complete all as specified and directed. 84 taking out old unserviceable ci body nrv / sluice valve / butterefly motorised valvve size 150 dia complete with nuts, bolts, rubber gaskets etc including, complete all as specified and directed. 85 taking down unserviceable air blower of existing size from foundation and deposit to mes store, complete all as specified and directed. 86 taking out old unserviceable ci body y strainerof size 150 mm, dia nuts, bolts, rubber gaskets etc, complete all as specified and directed. ( main pump house ) 87 taking out old unserviceable ci body sluice valve of size 250 / 350 mm, dianuts, bolts, rubber gaskets etc, complete all as specified and directed. ( new twt ) header by pass 2 88 taking out old unserviceable ci body sluice valve of size 450 mm, dia in depth of 18 mtr sumpnuts, bolts, rubber gaskets etc, complete all as specified and directed. ( level tbak 01 , gate 04 ) 89 taking out old unserviceable ci body foot valveof size 150 mm, dianuts, bolts, rubber gaskets etc, complete all as specified and directed. ( main pump house ) 90 taking out old unserviceable ci body or gun metalgate valve / nrvof size 65 mm, dianuts, bolts, rubber gaskets etc, complete all as specified and directed. ( grid 06 , blower 01 ) 91 taking out oldunserviceable ci body sluice valve / nrvof size 80 mm, dianuts, bolts, rubber gaskets etc, complete all as specified and directed. ( lorry filing unit ) 92 taking out unserviceable lt ug xlpe insulated 1100 volt grade heavy duty electric cables with aluminium conductor , cross sectional area 240 sqmm 3.5 core, complete all as specified and directed. 93 taking out unserviceable lt ug xlpe insulated 1100 volt grade heavy duty electric cables with aluminium conductor , cross sectional area 150 sqmm 3.5 core, complete all as specified and directed. 94 taking out unserviceable gitubingand connection25 mm size, complete all as specified and directed. 95 taking out unserviceable 10 sqmm coppercable, complete all as specified and directed. 96 taking out unserviceable lt ug xlpe insulated 1100 volt grade heavy duty electric cables with aluminium conductor , cross sectional area 70 sqmm 3.5 core, complete all as specified and directed. 97 supply and fixthree phase motor starterwith suitable arrangement forfloor mountedthree phase star delta starter ubical type, for indoordoor typeuse, floor mounted, factory fobricated, dust, weather & vermin proof, powder coated, made out of crca sheet of 2.15 mm thick and angle iron legs of size 50 mm x 50mm x 5mm with front openable with locking arrangementswith , incoporating heavy duty 4 pole contactor type tc1 dx overload relay type lr3d, auto start switch , 3 position slector switch for single phase preventer , auto / spp manual / manual voltmeter with selector switch , suppressedammeter , ryb led indicator, motor on&trip led indicator , tp c curve mcb for short circuit protection . sheet steel enclosure suitable forcapacity submersible pump with relay range 38 50 amps cat no be3spsddx 40357make c&s / l&t note : the cost of pcc foundation shall be deemed to be included in this item rate. ( sewae no ii ) 98 supply and fixthree phase motor starterwith suitable arrangement forfloor mountedthree phase star delta starter ubical type, for indoordoor typeuse, floor mounted, factory fobricated, dust, weather & vermin proof, powder coated, made out of crca sheet of 2.15 mm thick and angle iron legs of size 50 mm x 50mm x 5mm with front openable with locking arrangementswith , incoporating heavy duty 4 pole contactor type tc1 dx overload relay type lr3d, auto start switch , 3 position slector switch for single phase preventer , auto / spp manual / manual voltmeter with selector switch , suppressedammeter , ryb led indicator, motor on&trip led indicator , tp c curve mcb for short circuit protection . sheet steel enclosure suitable forcapacity submersible pump with relay range 14 22 amps , complete all as specified and directed.note : the cost of pcc foundation shall be deemed to be included in this item rate. ( sludge tank 02 ) 99 supply and fixthree phase motor starterwith suitable arrangement forfloor mountedthree phase dol starter ubical type, for indoordoor typeuse, floor mounted, factory fobricated, dust, weather & vermin proof, powder coated, made out of crca sheet of 2.15 mm thick and angle iron legs of size 50 mm x 50mm x 5mm with front openable with locking arrangementswith , incoporating heavy duty 4 pole contactor type tc1 dx overload relay type lr3d, auto start switch , 3 position slector switch for single phase preventer , auto / spp manual / manual ( as4 ) , on / off rocker switch, ryb led indicator, motor on&trip led indicator , dol in sheet steel enclosure suitable forcapacity submersible pump with relay range 5.5 8 amps, complete all as specified and directed.note : the cost of pcc foundation shall be deemed to be included in this item rate. ( trop 01, lorry filling 02 ) 100 excavation in trenches soft and loose soil not exc. 1.5 m wide and notexceeding 1.5m depth for foundation of poles / laying of cables / stay / strut etc not exceeding 10 sqm on planand getting out in soft / loose soil, complete all as specified and directed. 101 returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed. 102 removing excavated material ( soil ) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed. 103 material and labour for providingfazilka sand as in sand cushioning to under ground cable including punning down of sand in layers, complete all as specified and directed. 104 material and labour for cableprotection cover of ug lt cable by old size bricks common burnt clay building bricks sub class `b’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm, complete all as specified and directed....

Department Of Fertilizers - Punjab

40750145 bids are invited for sbc card of limitorque make (q3) , overload relay of limitorque make (q3) , power card of limitorque make (q3) , push button assembly of limitorque make (q3) total quantity : 6...

Punjab Water Resources Management And Development Corporation Limited - Punjab

40599958 e tenders are invited for the material required for running and maintenance of twells of various blocks of opt. maint. division, pwrmdc ltd hoshiarpur , l&t make 3 pole power contractor type ml 6 size fr 3 cat no. ss90921 , l&t make thermal overload relay type mn5 range 66 110 amp. cat no. ss9413700ko , bch make ct operated overload relay range 37.6 60.0 amp. cat no. ct2 mc305ana3c , voltmeter 0 500 amp. , ammeter 0 300 amp. for hoshiarpur/ mahilpur/ garhshankar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

40563176 e tenders are invited for the material required for running and maintenance of tube /wells of various blocks of this division l&t make thermal overload relay type mn5 range 66 110 amp cat no ss94137ooko , l&t make spare contact kit type ml 4 cat noss95311 , l&t make 3 pole power contactor type ml 4 size fr 3cat no ss90910 , l&t make spare coil type ml4 cat no ss91258...

Tata Memorial Centre - Punjab

39785383 supply of horizontal floor mounted ahu, frame made up of hollow extruded aluminum profile, chilled water double skin type made of 25 mm thick puf injected ( 40 kg / mm3 density ) panels consisting of g.i. casing of thickness 0.6 mm outside ( pre coated ) and 0.6 mm inside layer, complete with blower section ( didw centrifugal backward curved fan ) suitable for static pressure as detailed below, minimum 2 bend gss / pvc eliminators, cooling coil section with aluminum finned copper tubes ( tube thickness not less than 0.8 mm and dia not less than 1 / 2” ) suitable 6 row cooling coil and 2 row deep coil for heating coil with ss 304 casing, 12 fpi, filter sections with 50mm thick metal viscous / washable synthetic type air pre filters ( 90% down to 10 micron ) , electrical cable of suitable size as per ahus from panel to ahu to make it run , tefc belt driven motor suitable for 415 + 10% volts, 50hz, 3 phase, a.c supply, ss 304 drain pan duly insulated, etc. complete as per specifications and instructions of engineer in charge, of following capacities. ahu should be supplied with supply vcd. ahus must have one working and one stand by motors. ahu should be eurovent certified. makes: edgetech / zeco / systemair / wave and equivalent. motor make abb, siemens, hevels 12000 cfm / 55 mm static pressure / 26 tr cooling coil ( 4th floor ) , 12000 cfm / 55 mm static pressure / 30 tr cooling coil ( 5th floor ) , supply of the following ms class ‘c’ pipes of following diameter and of 6mtrstandard lengths for chilled water lines including insulation. insulating material should be 25mm thick nitrile insulation for chilled water pipe. insulation material should be supplied in tubular section / sheet of standard size make ms pipe tata / jindal / sail / jindal hissar 2.1 / 2 dia size ( 65 mm ) , 2 dia size ( 50 mm ) , butterfly valve supply of insulated ( 25 mm nitrile insulation ) butterfly valve ( manual ) with ci body ci disc. nitrile rubber seal & o ring pn 16 pressure rating for chilled water, complete with flanges, nut bolt etc. make audco / advance / l&t / honeywell 2.1 / 2 dia size ( 65 mm ) , 2 dia size ( 50 mm ) , pibcv valve supply of insulated ( 25 mm nitrile insulation with 26 g al cladding ) pibcv valve with ci bodyci disc. valves should have thermostat, actuators or any other accesories to run the ahus in automatic mode without bms system. make audco / advance / l&t / honeywell / danfoss / siemens 2.1 / 2 dia size ( 65 mm ) , 2 dia size ( 50 mm ) , y strainer valve supply of insulated ( 25 mm nitrile insulation with 26 g al cladding ) y strainer with ci body. nitrile rubber seal & o ring pn 16 pressure rating for chilled water. complete with flanges, nut bolt etc. make audco / advance / l&t / danfoss / s / sant / sandhu 2.1 / 2 dia size ( 65 mm ) , 2 dia size ( 50 mm ) , temperature guage supply of temperature guage suitable for measuring chilled water and hot water inlet and outlet temperatures of ahu make h guru / fiege , pressure guage supply of dial type pressure guage ( 0 10kg ) for measuring chilled water and hot water temperature at ahu inlet and outlet. make h guru / fiege , supply of auto air vents suitable for ahu mentioned at sl 1 for hot water and chilled water make anergy / castle / kartar , supply of ball valves ( ss in moc type only ) 25 mm , 10 / 12 mm , air distribution gi ducts supply of gi sheet metal of standard dimension ( 900x2500, 1000x2500, 1200x2500 ) for hvacducting work of following sizesfor supply air & return air system . the gi sheets shall be hot dip galvanized with coating of minimum 120 grams per square meter ( gsm ) of zinc. make : tata / sail / jindal / amns / asian 22 guage , 24 guage , thermal insulation supply of closed cell nitrile rubber thermal insulation class o for duct insulation of standard dimention ) . material should be supplied in rolls. make apl / aflex / kflex / armacell / aerofoam 19 mm for supply air , accoustic insulation supply of 15 mmaqua sound open cellnitrile rubber insulation of duct with standard dimension make apl / aflex / kflex / armacell / aerofoam make caryaire / dynacraft / airflow / systemair / uniaire 15 mm , accoustic insulation ( ahu room ) supply of 50mm resin bonded glass wool with 32 kg / cm3 density with 600x600 c channel of gi with aluminium perforated sheet .6 mm thick with tissue paper , fire damper supply of fire dampers for supply air duct / return air path i / c control wiring, the damper shall be motorized as required. size : 1700x500 mm fire damper make caryaire / dynacraft / airflow / systemair / uniaire actuator make danfoss / honeywell / siemens / anergy / belimo fire damper , actuator , controller , supply of canvas for connection of ahus and ducts , grills / diffusers. supplying of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. standard size 595x595 ( 375x375 neck size ) make caryaire / dynacraft / airflow / systemair / uniaire / dynamic , supply of return air diffusers of powder coated aluminium without volume control dampers anti smudge ring & removable core. standard size 595x595 ( 375x375 neck size ) make caryaire / dynacraft / airflow / systemair / uniaire / dynamic , supply fixing of powder coated extruded aluminium return air grills with louvers but without volume control damper complete as required. size make caryaire / dynacraft / airflow / systemair / uniaire / dynamic , fresh external weather louvers manufactured from 18 g gi frame complete with vcd, blades, bird screen etc. ( size 700x300 mm ) make caryaire / dynacraft / airflow / systemair / uniaire / dynamic , electrical accessories supply of wall mounted type electrical panels including system controlwiring with incoming, outgoingfeeders as described below : supply of wall mounted type electrical panels including system controlwiring with incoming, outgoingfeeders as described below : a.40a tpn mccb for 7.5 hp motor 01 set. b.ryb led type indication lights 01 set. c.vfd supply and simulation d.bypass fully automatic dol starter with built in single phasing preventer, contactor, overload relay suitable for 7.5 hp fan motor 01 set. e.auto manual type selector switch to facilitate auto start of fans after restoration ofpower 01 set. f.control wiring and safety circuit as required with start stop pbs and led type on / off indication lights. g.control wiring and safety circuit as required with start stop pbs and led type on / off indication lights. vfd make danfoss / abb / fuji / siemens panel accessories make abb / siemens / schinder / legrand / l&t , cables supply ofthe following sizes of 1.1 kv armoured xlpe insulated aluminium / copper conductor cables. cables shall be inclusive conductor cables. cables shall be inclusive of all clamps, saddles, screws, cable identification tags, insulating tapes, affectingterminal connections to the equipment as per the specifications and as required. make havells / polycab / kei 3 c x 4 sq.mm, cu , 3 c x 2.5 sq.mm, cu , 3 c x 1.5 sq.mm, flexible control cable copper , cable tray supplyingof following sizes of gi cable trays dulypainted, perforated type along with necessary elbows, bends, reducers etc. anchored along the wall / suspended from the slab / laid on terrace with necessary ms supports, anchor fasters, threaded rods etc. 150 x 50 x 1.6 mm , providing the following bare gi tape / gi wire including providing all fixing accessories & effecting proper connections. 25 x 3 gi strip , 2.5 tr fix speed splitair conditioning equipment using cfc / hcfc free refrigerant, having bee rating of minimum 3 star with outdoor stand. make hitachi, daikin, bluestar and equivalent. 4f hub room ( 1w+1s ) , 5f hub room ( 1w+1s ) , refrigerant pipe with 19 mm thick class o closed cell elastometricnitrile rubber tubular sleeves sections should be supplied seperatlyrefrigerant pipe with 19 mm thick class o closed cell elastometricnitrile rubber tubular sleeves sections should be supplied seperatly 9.5 mm , 15.88 mm , power cable 4 cx 4 sq mm between indoor and outdoor unit of standard length 90mtr , three pin top 16 amps , pvc pipe dia 25 mm for drain pipe , drain pump , supply of ss flexible hose pipe for installing fire sprinklers , supply of upright fire sprinklers , supply of ms c class pipe 25 mm dia of standard length 6 m , threaded rod 10 mm dia for duct , fasterner 10 mm for duct hilti , angle for duct support ( 40x40x3 mm ) , nut and bolts , neorine rubber self adhesive gasket for ducts ( 20 width x 3 mm thickness ) , sr 998 adhesive...

Department Of Fertilizers - Punjab

39635294 bids are invited for torque switch , geared limit , terminal card , push button , uec black , harness , ept , pin connector , overload relay , contactor , stem nut , over load relay , contactor assembly , transformer total quantity : 16...

Punjab Water Resources Management And Development Corporation Limited - Punjab

39599934 e tenders are invited for the material required for running and maintenance of tube /wells of various blocks of this division tender for supply material pack b , l&t make thermal overload relay type mn5 range 45 75 amp cat no ss94137oojo , l&t make spare contact kit type ml 3 cat noss95309 , l&t make 3 pole power contactor type ml 4 size fr 3cat no ss90910 , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 7 / 16 mm...

Punjab Water Resources Management And Development Corporation Limited - Punjab

39488250 material required for repair and maintenance of tubewells i variour blocks of dist gurdaspur under twell division pwrmdc ltd pathankot , l&t make 3 pole power contactor type mnx 70size fr 3 catno. cs97076 , l&t make thermal overload relay type mn5 range 45 75 amp cat no. ss94137oojo , bch make 40amp duros freedoms series 3 pole ac control contactor size g cat no. ce15gn3...

Water Resources Department - Punjab

38636402 material required for running and maintenance of twells in dhar block under tubewell division pwrmdc ltd pathankot , bch make 40amp nhd series 4 pole contactor size 1 ch cat no.nin , bch make ct operated overload relay range 37.6 to 60.0 amp cat no.mc305ana3c , fuse unit gkh kit kat porcelain rewirable type conform to is 2086 / 93 200amp 415 volts with extension strip....

Water Resources Department - Punjab

38615457 material required for running and maintenance of twells in various blocks under tubewell division pwrmdc ltd pathankot , bch make ct operated overload relay range 37.6 to 60.0 amp cat no.mc305ana3c...

Water Supply And Sanitation Department - Punjab

38606023 tender for repair & maintenance of starter and control panel of following capacity complete in all respects for various w/s schemes of block khera, fatehgarh sahib. 1 mccb 63amp 2 mccb 100amp 3 mccb 125amp 4 connector 18amp 5 connector 25amp 6 connector 32amp 7 connector 40amp 8 connector 50amp 9 overload relay 14 23amp 10 overload relay 20 33amp overload relay 30 50amp 11 12 single phase preventor star delta timer 13 amper meter selsctor switch 14 15 volt meter selector switch 16 auto manual selector switch 17 indicator 18 push button capacitor 19 20 add on block, connection strip 80 6 25 connection switch 100 6 voltmeter amp meter 26 it was digital amp digital 27 28 29 30 c.t set 60/5 c.t set 100/5 31 thimbel 10mm 32 thimbel 16mm 33 thimbel 25mm 34 elcb63amp 35 elcb 100amp 36 pvc wire imm 37 pvc wire 4mm pvc wire 6mm pvc wire 10mm 38 39 pvc wire 16mm 40 41 mcb channel 42 mu2 contractor 43 bopa rai starter 15 20 44 bopa rai starter 30 35 45 bentex starter 15 20hp bentex starter 20 25hp 46 47 bentex starter 30 35 48 patti set...

Rail Coach Factory - Punjab

38491525 supply, installation, testing and commissioning of 22.0 tr air cooled inverter ductable type air conditining units as per specification attached make: daikin, bluestar, carrier, mitshubishi, o general [ warranty period: 30 months after the date of delivery ] , supply, laying, connection and testing of interconnecting refrigerant pipe for 22.0 tr ac unit work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with ms hanger as per item part a ( e ) of specifications and make: totaline / mex flow / rajco or equivalent [ warranty period: 30 months after the date of delivery ] , providing & fixing control cum transmission wiring of copper in suitable conduits between indoor and out door unit. make: l&t / finolex / rr kable / kei / polycab / havells. [ warranty period: 30 months after the date of delivery ] , providing and fixing of m.s stand for outdoor units, made of ms angle 40x40x5 mm size with working platform all around duly painted with synthetic paint as per site requirement as per is 808 or latest / or equivalent make [ warranty period: 30 months after the date of delivery ] , supply, installation, testing and commissioning of fire retardant nonporous double layer flexible canvass connection between each duct type indoor unit and ducting. make: make of material to be got approved by dy cee / ps. [ warranty period: 30 months after the date of delivery ] , supply and fixing of 4000 cfm cabinet type exhaust with elementor pad , stp 80 mm centrifugal backward inclined ddiw blower with suitable high static pressure to create the required intake velocities and over come the pressure lose at the inlet of filters and duct, ddiw centrifugal blower ( motor outside the effluent air stream with different motor chamber for motor ) backward inclined, non over loading type. ( smaller motor ) mounted directly on motor shaft. ( slip losses and lesser maintenance ) dynamically balanced to provide a vibration free operation . fan to be direct driven to motor. make: zeco / edgetech / air tree / aircon / daikin ( water supply shall be provided by rcf ) [ warranty period: 30 months after the date of delivery ] , supply and fixing grilles / diffuse consisting of duct damper for hoods / grill with damper / diffuser with damper / diffuser without damper as per site requirement and list of makes make: system air / carryaire / dynamic / airflow. [ warranty period: 30 months after the date of delivery ] , supply and fixing of fresh air ahu of 3500 cfm cabinet type air washer forward with honeycomb pad , stp 40 to 50 mm inclined ddiw blower with suitable high static pressure to create the required intake velocities and over come the pressure lose at the inlet of filters and duct , ] .ddiw centrifugal blower ( motor outside the effluent air stream with different motor chamber for motor ) forward inclined, non over loading type. ( smaller motor ) mounted directly on motor shaft. ( slip losses and lesser maintenance ) dynamically balanced to provide a vibration free operation . fan to be direct driven to motor as per requirement. make: zeco / edgetech / air tree / aircon / daikin [ warranty period: 30 months after the date of delivery ] , supply, installation, testing and commissioning of control panel with star delta starter / dol panel with 01 no. 0 40 a tp mcb with conforming to bis dol / star delta starter, overload relay, ammeter ( 0 63a ) , single phase preventer. on off push button, on / off / trip indicators with protection fuse, manual reset overload relays, armoured cabling with proper tray supports from starter panel to fan motor starter panel should be provided with auto manual toggle switch & facility to operate on remote signal. necessary earthing, smoke & fire detector providing signal to starter panel, related control cabling shall be part of starter panel as approved by consultants & clients. controls & interlocking accessories as complete with connection / interconnection required for above switchgears complete in all respect to run / start the motor fan in case of fire. preferred make of switchgear and protection devices are l&t, siemens, schneider, legrand, havells or equivalent subject to prior approval by competent authority of rcf. drawings to be submitted for approval before supply and installation for satisfactory performance. [ warranty period: 30 months after the date of delivery ] , supply and fixing ss 304 hood with oil filters and hanging with rod , faster , volume control damper provide by each connection and gasket etc qty as per kitchen requirement & as per list of makes. filters make: airtech / purolator / puromatic or equivalent make to be got approved from competent authority [ warranty period: 30 months after the date of delivery ] => limited...

Rail Coach Factory - Punjab

38343649 supply of supply, installation, testing and commissioning of 22.0 tr air cooled inverter ductable type air conditining units as per specification attached make: daikin, bluestar, carrier, mitshubishi, o generalsupply, installation, testing and commissioning of 22.0 tr air cooled inverter ductable type air conditining units as per specification attached make: daikin, bluestar, carrier, mitshubishi, o general, supply, installation, testing and commissioning of 22.0 tr air cooled inverter ductable type air conditining units as per specification attached make: daikin, bluestar, carrier, mitshubishi, o general [ warranty period: 30 months after the date of delivery ] , supply, laying, connection and testing of interconnecting refrigerant pipe for 22.0 tr ac unit work with closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported with ms hanger as per item part a ( e ) of specifications and make: totaline / mex flow / rajco or equivalent , providing & fixing control cum transmission wiring of copper in suitable conduits between indoor and out door unit. make: l&t / finolex / rr kable / kei / polycab / havells. , providing and fixing of m.s stand for outdoor units, made of ms angle 40x40x5 mm size with working platform all around duly painted with synthetic paint as per site requirement as per is 808 or latest / or equivalent make , supply, installation, testing and commissioning of fire retardant nonporous double layer flexible canvass connection between each duct type indoor unit and ducting. make: make of material to be got approved by dy cee / ps. , supply and fixing of 4000 cfm cabinet type exhaust with elementor pad , stp 80 mm centrifugal backward inclined ddiw blower with suitable high static pressure to create the required intake velocities and over come the pressure lose at the inlet of filters and duct, ddiw centrifugal blower ( motor outside the effluent air stream with different motor chamber for motor ) backward inclined, non over loading type. ( smaller motor ) mounted directly on motor shaft. ( slip losses and lesser maintenance ) dynamically balanced to provide a vibration free operation . fan to be direct driven to motor. make: zeco / edgetech / air tree / aircon / daikin ( water supply shall be provided by rcf ) , supply and fixing grilles / diffuse consisting of duct damper for hoods / grill with damper / diffuser with damper / diffuser without damper as per site requirement and list of makes make: system air / carryaire / dynamic / airflow. , supply and fixing of fresh air ahu of 3500 cfm cabinet type air washer forward with honeycomb pad , stp 40 to 50 mm inclined ddiw blower with suitable high static pressure to create the required intake velocities and over come the pressure lose at the inlet of filters and duct , ] .ddiw centrifugal blower ( motor outside the effluent air stream with different motor chamber for motor ) forward inclined, non over loading type. ( smaller motor ) mounted directly on motor shaft. ( slip losses and lesser maintenance ) dynamically balanced to provide a vibration free operation . fan to be direct driven to motor as per requirement. make: zeco / edgetech / air tree / aircon / daikin , supply, installation, testing and commissioning of control panel with star delta starter / dol panel with 01 no. 0 40 a tp mcb with conforming to bis dol / star delta starter, overload relay, ammeter ( 0 63a ) , single phase preventer. on off push button, on / off / trip indicators with protection fuse, manual reset overload relays, armoured cabling with proper tray supports from starter panel to fan motor starter panel should be provided with auto manual toggle switch & facility to operate on remote signal. necessary earthing, smoke & fire detector providing signal to starter panel, related control cabling shall be part of starter panel as approved by consultants & clients. controls & interlocking accessories as complete with connection / interconnection required for above switchgears complete in all respect to run / start the motor fan in case of fire. preferred make of switchgear and protection devices are l&t, siemens, schneider, legrand, havells or equivalent subject to prior approval by competent authority of rcf. drawings to be submitted for approval before supply and installation for satisfactory performance. , supply and fixing ss 304 hood with oil filters and hanging with rod , faster , volume control damper provide by each connection and gasket etc qty as per kitchen requirement & as per list of makes. filters make: airtech / purolator / puromatic or equivalent make to be got approved from competent authority => limited...

Department of Cooperation - Punjab

38147270 purchase of electrical material electrical material , power contactor coil voltage 415 volt ac sl 6 , power contactor coil voltage 415 volt ac sl 4 , power contactor coil voltage 230 volt ac sl 6 , power contactor coil voltage 230 volt ac sl 4 , power contactor coil voltage 230 volt ac sl 3 , power contactor coil voltage 230 volt ac sl 2 , power contactor coil voltage 220 volt ac sl 1.5 , spare kit sl 1.5 , spare kit sl 2 , spare kit sl 3 , spare kit sl 10 , timer 0 to 60 sec model 800 s selec , dol stater sl 3 relay 28 42 amp cat no. sm9u07 , dol stater sl 1.5 relay 06 10 amp , hrc fuse size 00 125 amp shn007 , hrc fuse size 01 250 amp shn17 , hrc fuse size 02 400 amp shn21 , hrc fuse size 00 100 amp , moving contact 250a type sb/sbc , moving contact 400a type sb/sbc , moving bridge 400a , timer et. 100 range 0 to 60 sec. , spare kit 3tf 47 , spare kit 3tf 48 , spare kit 3tf 52 , spare kit 3tf 46 , contactor 3tf 47 , contactor 3tf 48 , switch sac 63a 415v 3 phase , switch sb/sbc 250a , switch sb/sbc 400a , switch sb/sbc 630a , bakilite fuse fitting 32 amp ssf , fuse holder single pole 160 amp sfh 160 , overload relay type sl 3 (14 23 amp) , overload relay type sl 3 (20 32 amp)...

Punjab Water Resources Management And Development Corporation Limited - Punjab

38029971 e tenders are invited for the material required for running and maintenance of tube /wells of various block under this division tender for supply material package c , fuse unit gkh kit kat porcelain rewirable type conform to is2086 / 93200 amp 415 volt with extension strip , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 7 / 16 mm , l&t make thermal overload relay type mn5 range 66 110 amp cat no ss94137ooko...

Punjab Water Resources Management And Development Corporation Limited - Punjab

38029889 e tenders are invited for the material required for running and maintenance of tube /wells of various blocks of this division tender for supply material pack c , l&t make 3 pole power contactor typemnx 40 amp size fr 2 cat no cs94190 , l&t make thermal overload relay type mn5 range 66 110 amp cat no ss94137ooko , l&t make spare contact kit type mnx 40 cat nocs94147 , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 19 / 16 mm...

Punjab Water Resources Management And Development Corporation Limited - Punjab

38029870 e tenders are invited for the material required for running and maintenance of tube /wells ofvarious block under this division bch make duros freedom series 3 pole ac control contactor size g cat noce15gn 3 , bch make 40 amp nhd series 4 pole contactor size 1 cat no nin , bch make ct operated overload relay range 37.6 60.0 amp cat no ct2 mc305ana3c...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37973895 e tenders are invited for the material required for running and maintenance of tube wells of various blocks of opt. and maint. division, pwrmdc ltd hoshiarpur , l&t make 3 pole power contactor type ml 6 size fr 3 cat no. ss90921 , l&t make thermal overload relay type mn 5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur / mahilpur / garhshankar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37941062 e tenders are invited for the material required for running and maintenance of tube wells of various blocks of opt. and maint. division pwrmdc ltd hoshiarpur , l&t make 3 pole power contactor type ml 6 size fr 3 cat no. ss90921 , l&t make thermal overload relay type mn 5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur / mahilpur / garhshankar...

Water Resources Department - Punjab

37868950 e tenders are invited for the material required for running and maintenance of t / wells of block balachaur and saroya of dist. sbs nagar , sub cable 16 mm23 core copper conduct as per isi 694 1990 , kit kat 200 amp with connection pati , pvc wire 19 / 64copper , pvc wire 7 / 64copper , voltmeter , amperemeter , single phase preventor , overload relay 45 to 75 amp , contactor ml4 ( 415 volt ) , overload relay 66 to 110 amp , overload relay 37 to 60 amp , sub cable 10 mm23 core copper conduct as per isi 694 1990 , sub cable 25 mm23 core copper conduct as per isi 694 1990 , spare kit ml4 , electronic timer typest 100 cat no. st803280000 , contactor ml3 , spare coil ml4 , contactor ml6 , spare kit ml6 , fornurpur bedi block of distt ropar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37830500 e tenders are invited for the repair and rewinding of submersible motor pumps of the following tubewells in various block of distt. hoshiarpur under opm division hoshiarpur , l&t make 3 pole power contactor type ml 6 size fr 3 cat no. ss90921 , l&t make thermal overload relay type mn 5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur/ mahilpur/garhshankar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37691139 e tenders are invited for the repair and rewinding of submersible motor pumps of the following tubewells in various block of distt. hoshiarpur under opm division hoshiarpur , l&t make 3 pole power contactor type ml 6 size fr 3 cat no. ss90921 , l&t make thermal overload relay type mn 5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur/ mahilpur/garhshankar...

Water Resources Department - Punjab

37625707 tender for material required for running and maintenance of twells under tubewell division pwrmdc ltd pathankot l&t make 3 pole power contactor type ml 2 size fr 2cat no. ss90701 , overload relay l&t 28 to 42 amp....

Water Resources Department - Punjab

37625703 tender for material required for running and maintenance of twells under tubewell division pwrmdc ltd pathankot 1 l&t make 3 pole power contactor type ml 2 size fr 2cat no. ss90701 2 overload relay l&t 28 to 42 amp...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37566862 e tenders are invited for the repair and rewinding of submersible motor pumps of the following tubewells in various block of distt. hoshiarpur under opm division hoshiarpur , l&t make 3 pole power contactor type ml 6 size fr 3 cat no. ss90921 , l&t make thermal overload relay type mn 5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur / mahilpur / garhshankar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37406488 e tenders are invited for the repair and rewinding of submersible motor pumps of the following tubewells in various block of distt. hoshiarpur under opm division hoshiarpur , l&t make 3 pole power contactor type ml 6 size fr 3 cat no. ss90921 , l&t make thermal overload relay type mn 5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur/ mahilpur/garhshankar...

Bhakra Beas Management Board - Punjab

37393007 bids are invited for contactor mse mnx r5 thermal overload relay , fn 630 switch disconnector fuse unit 630 a , spare contact kit of contactor mnx 325 , timer y upon triangle cat no 2asdto , spare coil , spare contact kit of contactor , mn2 thermal over load relay , spare contact kit of contactor mnx140 , incomer 400a tp mccb dn3b 400 d , spare contact kit of contactor mnx 185 , tape wound panel current transformers , spare contact kit of contactor mnx 400 , mn2 thermal overload relay , mn5 thermal overload relay , contactor kit , contactor kit , over load relay , main switch make l and t fn 100 , main switch make l and t fn 125 , contactor total quantity : 94...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37346014 e tenders are invited for the material required for running and maintenance of tube /wells of various blocks of this division l&t make thermal overload relay type mn5 range 66 110 amp cat no ss94137ooko , l&t make spare contact kit type ml 4 cat noss95311 , l&t make 3 pole power contactor type ml 4 size fr 3cat no ss90910...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37118795 e tenders are invited for the material required for running and maintenance of tube /wells of various blocks of this division l&t make thermal overload relay type mn5 range 45 75 amp cat no ss94137oojo , l&t make spare contact kit type ml 3 cat noss95309 , l&t make 3 pole power contactor type ml 4 size fr 3cat no ss90910...

Punjab Water Resources Management And Development Corporation Limited - Punjab

36598825 e tenders are invited for the material required for running and maintenance of twells of various blocks of opt and maint division pwrmdc ltd hoshiarpur , l&t make 3 pole power contactor type ml 4, 70 amp. size fr 3 cat no. ss90910. , l&t make thermal overload relay mn5 range 45 75 amp. cat no. ss9413700jo , l&t make thermal overload relay mn5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur / mahilpur / garhshankar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

36448531 e tenders are invited for the material required for running and maintenance of twells of various blocks of opt and maint division pwrmdc ltd hoshiarpur , l&t make 3 pole power contactor type ml 4, 70 amp. size fr 3 cat no. ss90910. , l&t make thermal overload relay mn5 range 45 75 amp. cat no. ss9413700jo , l&t make thermal overload relay mn5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur/ mahilpur/ garhshankar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

36448530 e tenders are invited for the material required for running and maintenance of twells of various blocks of opt. and maint. division pwrmdc ltd hoshiarpur , l&t make 3 pole power contactor type ml 3 size fr 2 cat no. ss90721 , bch make 73 amp. duros freedom series 3 pole ac control contactor size g cat no. ce15kn 3 , bch make ct operated overload relay range 37.6 60.0 amp cat no ct2 mc305ana3c , fuse units gkh (kit kat) porcelain type confirm to is:2086/93 rewirable fuse and base career 200 amp. 415 volt with extension strip. , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 19/16mm for hoshiarpur/ mahilpur/garhshankar...

Water Supply And Sanitation Department - Punjab

36219476 tender for supplying and fixing automatic star delta submersible control panelsuitable for 20 25 hp submersible motor comprising of main switch digital voltage meter with auto 3 phase rotation r.y y.b, br digital ampere meter, single phase preventer overload relay with range 20 to m32 amp having push button for star run and stop functions housed in powder coated sheet steel enclosure. sailbrah...

Water Supply And Sanitation Department - Punjab

36219453 tender for supplying and fixing automatic star delta submersible control panelsuitable for 20 25 hp submersible motor comprising of main switch digital voltage meter with auto 3 phase rotation r.y y.b, br digital ampere meter, single phase preventer overload relay with range 20 to m32 amp having push button for star run and stop functions housed in powder coated sheet steel enclosure....

Water Supply And Sanitation Department - Punjab

36219381 supplying and fixing automatic star delia submersible control — panel suitable for 20 25 1w submersible motor comprising of main switch: digital voltage meter with auto 3 phase rotation ry. yb, br: digital ampere meter: single phase preventer; overload relay with range 20 to 32 amp. having pnh button for start. riai and stop functions: housed in powder coated sheet steel n enclosure....

Punjab Water Resources Management And Development Corporation Limited - Punjab

36104850 e tenders are invited for the material required for running and maintenance of t / wells of various blocks of this division from reputed manufactures / firms registered with e procurement portal with punjab govt., as per detail given below l&t make 3 pole power contactor type mnx 40 sizefr 2 cat no cs94190 2 l&t make spare contact kit type mnx 40 cat nocs94147 3 l&t make thermal overload relay type mn5 range 66 110 amp cat no ss94137ooko 4 pvc shalimar make coppe wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 7 / 16 mm ...

Punjab Water Resources Management And Development Corporation Limited - Punjab

36104841 e tenders are invited for the material required for running and maintenance of t / wells of various blocks of this division from reputed manufactures / firms registered with e procurement portal with punjab govt., as per detail given below l&t make thermal overload relay type mn5 range 45 75 amp cat no ss94137oojo 2 l&t make spare contact kit type mnx 110 cat nocs94154 3 l&t make 3 pole power contactor type ml 4 size fr 3cat no ss90910 ...

Military Engineer Services - Punjab

35740784 providing of ph i of otm accn for mech inf bn at ferozepur under ge ( east ) ferozepur cantt 1 note: (i) please refer schedule a notes given on serial page no. 21 to 27 of tender documents. 2 lumpsum/ other pre priced provisional schedules of works 3 lump sum price worked out by the contractor for building works as listed in schedule a part i brought forward from serial page no. 29. 4 lump sum price worked out by the contractor for site clearance and earthworks as listed in schedule a part ii brought forward from serial page no. 30. 5 lump sum price worked out by the contractor for internal electrification works as listed in schedule a part iii brought forward from serial page no. 37. 6 lump sum price worked out by the contractor for internal water supply works as listed in schedule a part iv brought forward from serial page no. 38. 7 lump sum price worked out by the contractor for sewage disposal works as listed in schedule a part v brought forward from serial page no. 40. 8 lump sum price worked out by the contractor for road, pathand culverts works as listed in schedule a part vi brought forward from serial page no. 42. 9 lump sum price worked out by the contractor for area drainage works listed in schedule a part vii brought forward from serial page no. 43. 10 lump sum price worked out by the contractor for boundary wall, compound wall,fencing and gate works listed in schedule a part viii brought forward from serial page no. 45. 11 lump sum price worked out by the contractor for external water supplyworks as listed in schedule a part ix brought forward from serial page no. 46. 12 lump sum price worked out by the contractor for external electrificationworks as listed in schedule a part x brought forward from serial page no. 50. 13 lump sum price worked out by the contractor for dg set works as listed in schedule a part xi brought forward from serial page no. 51. 14 lump sum price worked out by the contractor for summer appliances worksas listed in schedule a part xii brought forward from serial page no. 53. 15 lump sum price worked out by the contractor for rain water harvesting worksas listed in schedule a part xiii brought forward from serial page no. 54. 16 lump sum price worked out by the contractor for hot water supply works as listed in schedule a part xiv brought forward from serial page no. 56. 17 lump sum price worked out by the contractor forlightening conductor works as listed in schedule a part xv brought forward from serial page no. 57. 18 lump sum price worked out by the contractor for bore well works as listed in schedule a part xvi brought forward from serial page no. 58. 19 lump sum price worked out by the contractor for stp works as listed in schedule a part xvii brought forward from serial page no. 59. 20 lump sum price worked out by the contractor for treated sewage water supply works as listed in schedule a part xviii brought forward from serial page no. 60. 21 lump sum price worked out by the contractor for pcc hard standing works as listed in schedule a part xix brought forward from serial page no. 61. 22 schedule a part xx misc items internal electrification works 23 supply and fix energy efficient led bulb, b229 watt complete all as specified and directed. make: cat no lhldbweb4l8r009 of havells or eqvt in philips and cg. 24 supply and fix modular rj telephone socketcomplete all as specified and directed by engr in charge. make: cat no / sap code ahlkhww000 of havells or eqvt in legrand/ schneider. 25 supply and fix modular tv socket complete all as specified and directed by engr in charge.cat no /sap code ahlkt0w000 of havells or eqvt in legrand/ schneider. 26 supply and fixdecorative 9w ledwall mounting fittings complete set including 9 w led lamp all as specified and directed. make: cat no lhf0eceitzib014 glaze wall light of havellsor eqvt in philips / crompton. 27 s&f gi pipe bracket made out of gi pipe light grade 32 mm dia and bend to shape 1.5 mtr long ms clamps made out of ms flat iron of size 25x4 mm thick with nuts & bolts, washers complete as specified and directed 28 supply and fix wall mounting fan industrial type 450mm sweep, 230v, 50hz , 1400 rpm, 100w, 150cum/hr air delivery, copper motor, double ball bearing , 60db 65db nosie level, upward and down adjustable, 60 degree oscillation degree, 3 nos metal balde guarded with 112 spokes metal case complete with mountings accessories kit, wall bracket, nut, bolt washer etc with connection pvc three core copper wire all as specified and directed. make: cat no fhacwstscl18 of havells or eqvt in legrand/ philips. 29 sewage disposal works 30 material and labour for laying dwc hdpe 150mm (i/d) sn8 pipe including all necessary fittings for carrying sewage complete all as directed by engineer in charge. 31 material and labour for laying dwc hdpe 200mm (i/d) sn8 pipe including all necessary fittings for carrying sewage complete all as directed by engineer in charge. 32 material and labour for construction of under gournd sump cum pump house complete all as shown on drawings and as specified. (drg no cejz 04/2000 sheet no. 1/2 to 2/2). 33 road, pathand culverts works 34 material and labour for cat eye abs plastic with nail of size 100mm x 100mm, 20mm reflective glass colour white/ red/ yellow provided with steel zinc plated with bolt of 12mm dia length 120mm for fixing on road by hammering complete all as directed by engineer in charge. 35 material and labour for delineator 47mm dia 600mm long with high intensity reflective sheeting complete all as directed by engineer in charge. 36 external water supply works 37 supplying, laying, jointing and testing in trenches centrifugally cast 150mm bore ductile iron pipe class k 7 conforming to is : 8329 2000 of min wall thickness 5.4mm including testing complete all as specified. 38 supplying, laying, jointing and testing in trenches centrifugally cast 100mm bore ductile iron pipe class k 7 conforming to is : 8329 2000 of min wall thickness 5.4mm including testing complete all as specified notes for srl no. 6.01 & 6.02 : (a) excavation, earth work and di fittings shall be measured and paid for separately under respective items(b) cost of tyton joints is included in the rate quoted.(c) standard length of the pipe should be 5.50m or 6.0m as available.(d) the measurement of the pipe shall be net as fixed between the fittings including short length without any allowance for cutting and wastage and for the portion entering in the socket of all pipes and fittings.(e) predespatch inspection & testing of di pipe shall be carried out by the representative of ao. all the expenditure for the same shall be borne by the contractor and the quoted rates shall be deemed to be included for the same 39 supply, fixing and testing ductile iron fittings such as bends (any type radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘y’ junction. double branch, cross (all sockets or sockets and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket. spigot caps and plugs suitable for 100 to 150mm ductile iron pressure pipes of k 7 classification and push on flexible rubber gasket joints complete all as specified and directednotes :(a) di fittings shall be of same make as of di pipes or of make as recommended by manufacturers(b) the weight of the fittings shall be measured and paid as given in relevant is or actually provided whichever is less.(c) all fittings shall be relevant is stamping marking.(d) excavation and earth work shall be measured and paid for separately.(e) cost of the joints and jointing materials shall be deemed to be included in the relevant items of di pipes here in before 40 construction of brick masonary valve pit chamber of 1050mm x 750mm x 1000mm size (internal dimensions) with ms sheet cover 6mm thick and angle iron 40mm x 40mm x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified and shown on drgs. breakdown of qtyexternal water supply 4 (each)treated sewage water supply 2 (each) 41 construction of brick masonary valve pit chamber of 900 x 900 x 1000mm size (internal dimensions) with ms sheet cover 6mm thick and angle iron 40 x 40 x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified andshown on drgs. breakdown of qtyexternal water supply 5 (each)treated sewage water supply 3 (each) 42 construction of brick masonary valve pit chamber of 600mm x 600mm x 1000mm size (internal dimensions) with ms sheet cover 6mm thick and angle iron 40mm x 40mm x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified andshown on drgs. note for srl item no. 6.04 to 6.06: 43 supply and fixing rcc water main route indicator of size 75cm x 40cm x 10cm duly marked with mes water mains bore made of cement concrete (1:2:4) type b 1 as in foundation of electric poles/ struts etc including necessary form work, fair, finished embedded in pcc bed including necessary excavation and re filling, proposed to be installed after 25m on pipe lines of size 150mm, 100mm, 80mm and 50mm complete all as directed by engineer in charge. 44 external electric supply works 45 supply ,install, testing and commissioning power factor control lt panel board (apfc) of 200 kvar, 433 volt, 50 cycle per second cubical type front and back openable double leaf type dust & vermin proof with locking arrangement powder coated with approved colour , made out of crca sheet 14 swg, outdoor herewith canopy, cable entry glands, double compressor type, duly prewired with suitable pillar made out of 50 mmx 50mm x6 mm angle iron grouted in and including pcc (1:2:4) using 20 mm graded stone aggregate complete all as per is 8623 1933 & all as per latest isi specification and suitable for housing and including following accessories : (a) incoming mccb of 250 amps 36 ka rupturing capacity , 3 pole thermal magnetic release type shunt trip coil 01 no (b) copper bus bar duly insulated with colour coded heat shrinkable sleeve insulation for three phase four wire system of 250 amps capacity rating with suitable size/ type on hygroscopic on combustion track resistance, high strength frp/mc/dmc insulators.(c) capacitor switching contactor of suitable capacity (contractor amps rating shell not be less than 1.5 times nominal current rating, three pole, coil voltage 440 volts, one each for number of capacitor bank , each contractor shell be protected with 10 ka , d curve type (mcb to be provided for 1.33 times kvar i.e. 100 % current capacity of the mpfcs irrespective of the fact that contractor’s rating is 1.5 times) (mccb 25 ka shall be provided for the above 63 amps rating)(d) one set current transformer (cts) of suitable ratio (with secondary of 5 amps ) to be fixed on bus bar of existing panel including connection with 2 core 1.5 sqmm armoured copper conductor complete with gland etc.(e) shunt capacitor mpp type heavy duty 200 kvar distributed in step of 6 steps with configuration (2x12.5 + 1x25 + 3x50) directly connected to maintain power factor at 0.99 or unity, housed in self extinguishing insulated material with built in. 46 supply and fixing 3 core 1.5 sqmm pvc insulated and frls pvc round sheathed copper conductor flexible 1100 volts for connection from junction box to street light fittings complete all as specified and directed. make :polycab/ havells/ finolex/ paragon 47 supply and fixing street light pole cable junction box ip 65 with metric knockouts for cable entry with mcb sp 6 amps,10 ka and the box made out of thermal plastic material suitable for 16/25 sqmm ug cable including clamps bolts, nuts, duly painted etc complete all as and directed by engineer in charge. 48 supply and fixing bracket made out of 40 mm dia gi light grade tubing 1.2 meter long and bent to angle /shape of 120 degree angle at the meddle from vertical fixed with clamps nuts and bolts washers complete all as specified and directed 49 supply and fixing automatic street light switchfor automatic switching of street light/high mast light (timer switch)for three phase loadlight.the digital timer 24 hrs alongwith suitable power contractor as per iec 60947 4 1, including incoming & outgoing mcbs, smc enclosure and support terminal and enclosed in pole/wall mounted factory made pvc enclosure made out of rust proof, shock & termite proof and frls grade confirming to ip 54 of capacity 6 kw, three phase, current rating 32/tp and mcb rating 40/tpn, having facility of manual operation complete all as directed by engineer in charge. 50 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac,3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.8 m x 1.5 m x 1.0 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location main panel (x mer 400 kva)(i) panel having common aluminium bus bar of capacity 1600 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)acb microprocessor released and thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 800 amp 4 pole, 50 kawith overload variation 40 100% 1 no,(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 amp 3 pole, 35 ka with overload variation 40 100% 1 no,(for apfc ) (b) do but 250 amp 1 no, (c) do but 160 amp 1 no, (d) do but 125 amp 02 nos,(e) do but 63 amp 6 nos,(iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 800 amps digital type square shape 96mm flush mounted with selector switch and cts 800/5 a 1 no.(vi) phase indicating lamp led type 03 nos 51 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac,3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location near smbk(i) panel having common aluminium bus bar of capacity 500 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 amp 4 pole, 35 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, 16 ka with overload variation 40 100% 4 nos. (b) do but 32 amp 2 nos, (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 250 amps digital type square shape 96mm flush mounted with selector switch and cts 250/5 a 1 no.(vi) phase indicating lamp led type 03 nos 52 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtrbelow gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location near jco mess(i) panel having common aluminium bus bar of capacity 320 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 160 amp 4 pole, icu=ics=35 kawith overload variation 40 100% 1 no.(iii) outgoing(a) mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 80 amp 4 pole, icu=ics=25 ka with overload variation 40 100% 1 no. (b)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 4 nos. (c)mcb isolator 25 amp spn 10 ka, 240v 01 no, (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 160 amps digital type square shape 96mm flush mounted with selector switch and cts 160/5 a 1 no.(vi) phase indicating lamp led type 03 nos 53 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location near offr mess(i) panel having common aluminium bus bar of capacity 250 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 125 amp 4 pole, icu=ics=25 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 2 nos. (b)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=25 ka with overload variation 40 100% 2 nos. (c)mcb isolator 32 amp spn 10 ka, 240v 04 nos, (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 125 amps digital type square shape 96mm flush mounted with selector switch and cts 125/5 a 1 no.(vi) phase indicating lamp led type 03 nos 54 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location near adm block(i) panel having common aluminium bus bar of capacity 250 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 125 amp 4 pole, icu=ics=25 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 2 nos. (b)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=25 ka with overload variation 40 100% 2 nos. (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 125 amps digital type square shape 96mm flush mounted with selector switch and cts 125/5 a 1 no.(vi) phase indicating lamp led type 03 nos 55 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location mt area panel(i) panel having common aluminium bus bar of capacity 200 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, icu=ics=16 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 4 nos. (b)mcb isolator 25 amp spn 10 ka, 240v 10 nos. (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 100 amps digital type square shape 96mm flush mounted with selector switch and cts 100/5 a 1 no.(vi) phase indicating lamp led type 03 nos 56 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.4 m x 1.25 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location street light panel(i) panel having common aluminium bus bar of capacity 200 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, icu=ics=16 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 3 nos. (b)on load change over switch 415v in sheet metal enclosures 4 pole of capacity 63 amp. (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 100 amps digital type square shape 96mm flush mounted with selector switch and cts 100/5 a 1 no.(vi) phase indicating lamp led type 03 nosnote srl item no. 7.06 to 7.12: lt panel shall be got tesed from cpri type test for 4000 amp with breaking capacity not less than 65 ka and ip 56 as per is 61439 part 1& 2. 57 supply and fixing of rubber mat (insulation mat) of dimension 1m x 2m and 2 mm thick complete for electrical installation and dg sets panels complete all as directed by engineer in charge. 58 supply and fixing of rubber mat of dimension 1m x 2m and 3 mm thick complete for electrical installation and stp main panels complete all as specified and directed. 59 supply and fixing rcc ht cable route indicator of size 75cmx40cmx10cm duly marked with ht cable made ofcement concreted (1:2:4) type b 1 as in foundation of electric poles/struts/ etc including necessary form work, fair finished embedded in pcc bed including necessary excavation and re filling complete all as specified and directed 60 dg set works 61 supply, installing, commissioning and testing of eco friendly diesel engine driven generating set silent type confirming to cpcb conditions/ norms, 62.5 kva, or next higher capacity as available/manufactured at 0.9 power factor directly coupled alternator & engine. the diesel set shall consist of a diesel engine coupled directly to a matching parts or as recommended/ provided by the manufacturer on a common base frame and thereafter installed in the cpcb approved acoustic enclosure. the complete set conforming to and test certificate as per cpcb norms and as specified) complete without amf control panel standardized by manufacturer, fuel tank with mounting arrangement, flexible exhaust pipe complete with the following: (a) engine (prime mover) : diesel engine 1500 rpm of minimum 84 bhp or recommended by manufacturer turbo charged water cooled,12 volts electric battery start, complete with fly wheel and all standard fitting/ fixtures as per manufacturing practice including suitable engine control panel/ dash board with electronic technometer. lube oil temp and pressure gauges water temp gauge frequency meter (digital type) including safety self starter, alternator, cogged v belt, fuel tank with first fill of lube oil and coolant (as applicable) etc. (b) alternator :alternator ac 3 phase 415 volts 4 wire rated line current for output 62.5 kva, pf 0.8, 1500 rpm insulation class enclosures /spdp self exited self regulated brushes, complete with avr with plus and minus voltage regulation directly coupled to and match the above engine. (c) anti vibration pads for mounting engine, alternator assembly on base frame/plate or as recommended by the manufacturer.(d) base plate made out of structural steel as per manufacturer recommended design/specification.(e) acoustic enclosure of an internal type approved/certified acoustic enclosure (as per cpcb norms for the dg set) to restrict the noise level to 75 db at one meter distance and temp rise with in canopy shall not exceed 7 degree centigradebeyond ambient temp. it shall be made of 16 swg or manufacturer standard norms crca sheet with powder coated finish on outside and provided with non ignitic fire retardant foam as acoustic material. the doors and glass windows shall be ismc. it shall also include the following: (i) silencer/absorption the non resistance, residential and exhaust pipe covered with asbestos rope.(ii) internal wiring with pvc copper conductor cable is 694 marked frls in conduit and fluorescent lamp fittings.(iii) fuel tank of 16 hours cap but not less than made of 14 swg crca sheet duly powder coated and provided with float gauge and fuel float switch.(iv) one no 12 v x 180 ah 25 plates maintenance free batteries as recommended by manufacturer.(f) the exhaust of dg set shall be fitted with emission control devises as per latest cpcb norms and as specified and also contractor shall submit test certificate of dg set as per latest cpcb norms. 62 supply, installing, commissioning and testing of eco friendly diesel engine driven generating set silent type confirming to cpcb conditions/ norms, 40 kva, or next higher capacity as available/manufactured at 0.9 power factor directly coupled alternator & engine. the diesel set shall consist of a diesel engine coupled directly to a matching parts or as recommended/ provided by the manufacturer on a common base frame and thereafter installed in the cpcb approved acoustic enclosure. the complete set conforming to and test certificate as per cpcb norms and as specified) complete without amf control panel standardized by manufacturer, fuel tank with mounting arrangement, flexible exhaust pipe complete with the following: (a) engine (prime mover) : diesel engine 1500 rpm of minimum 51 bhp or recommended by manufacturer turbo charged water cooled,12 volts electric battery start, complete with fly wheel and all standard fitting/ fixtures as per manufacturing practice including suitable engine control panel/ dash board with electronic technometer. lube oil temp and pressure gauges water temp gauge frequency meter (digital type) including safety self starter, alternator, cogged v belt, fuel tank with first fill of lube oil and coolant (as applicable) etc. (b) alternator :alternator ac 3 phase 415 volts 4 wire rated line current for output 40 kva, pf 0.8, 1500 rpm insulation class enclosures /spdp self exited self regulated brushes, complete with avr with plus and minus voltage regulation directly coupled to and match the above engine. (c) anti vibration pads for mounting engine, alternator assembly on base frame/plate or as recommended by the manufacturer.(d) base plate made out of structural steel as per manufacturer recommended design/specification.(e) acoustic enclosure of an internal type approved/certified acoustic enclosure (as per cpcb norms for the dg set) to restrict the noise level to 75 db at one meter distance and temp rise with in canopy shall not exceed 7 degree centigradebeyond ambient temp. it shall be made of 16 swg or manufacturer standard norms crca sheet with powder coated finish on outside and provided with non ignitic fire retardant foam as acoustic material. the doors and glass windows shall be ismc. it shall also include the following: (i) silencer/absorption the non resistance, residential and exhaust pipe covered with asbestos rope.(ii) internal wiring with pvc copper conductor cable is 694 marked frls in conduit and fluorescent lamp fittings.(iii) fuel tank of 16 hours cap but not less than made of 14 swg crca sheet duly powder coated and provided with float gauge and fuel float switch.(iv) one no 12 v x 88 ah 25 plates maintenance free batteries as recommended by manufacturer.(f) the exhaust of dg set shall be fitted with emission control devises as per latest cpcb norms and as specified and also contractor shall submit test certificate of dg set as per latest cpcb norms. 63 summer appliances works 64 supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170v 250v with output voltage stabilized at 230v with accuracy of ±2.5% and of capacity 1.0 kva complete all as directed by engineer in charge. 65 supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170v 250v with output voltage stabilized at 230v with accuracy of ±2.5% and of capacity 2.0 kva complete all as directed by engineer in charge. 66 supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170v 250v with output voltage stabilized at 230v with accuracy of ±2.5% and of capacity 3.0 kva complete all as directed by engineer in charge. 67 supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 250v with output voltage stabilized at 230v with accuracy of ±2.5% and of capacity 5.0 kva complete all as directed by engineer in charge. 68 supply and installed refrigerators, electric driven (single phase) of capacity 220 ltrs frost free, 5 star rated complete all as directed by engineer in charge. 69 supply and installed refrigerators, electric driven (single phase) of capacity 400 ltrs frost free, 5 star rated complete all as directed by engineer in charge. 70 supply and installing desert cooler electric driven (single phase) having nominal air flow capacity of 4000 cum/ hrs 230v made of 20 gauge ms sheet and size not less than 90cm, 78cm x 78cm surface area from top and bottom 62cm x 54cm front grill size including tullu pump with rotary switch (4 speed) 5 amp switch on front side, drain valve including two coats synthetic of enamel paint over a coat of primer complete all as directed by engineer in charge. 71 rain water harvesting works 72 material and labour for gravel packing including jute as filter media 4mm to 6mm size around ms pipe complete all as directed by engineer in charge. 73 material and labour for filling of gravel in trenches of size 6mm to 10mm upto height of 0.50m complete all as directed by engineer in charge. 74 material and labour for filling of gravel in trenches of size 2mm to 4mm upto height of 1.0m complete all as directed by engineer in charge. 75 bore well works 76 material and labour for drilling of 675mm bore hole from ground level to 20 m depth below ground levelin any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes complete all as specified and as directed : notes :(a) record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) the bore/tube well should be constructed by the agency as approved by ge (east) fzr.(c) the rates also includes transportation of rig machine & t&p at site.(d) trail bore will be drilled, if sufficient wet strata is available then erw casing will be lowered. in case strata is not available payment only for drilling will be made 77 all as per srl item no. 11.01 here in before but from 20 m below ground level to 40 m depth below ground level. 78 all as per srl item no. 11.01 here in before but from 40 m below ground level to 60 m depth below ground level. 79 material and labour for drilling of 525 mm bore hole from 60 mtr below ground level to 85 mtr depth below ground level in any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes complete all as specified and as directed : notes :(a) record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) the bore/tube well should be constructed by the agency as approved by ge (east) fzr.(c) the rates also includes transportation of rig machine & t&p at site.(d) trail bore will be drilled, if sufficient wet strata is available then erw casing will be lowered. in case strata is not available payment only for drilling will be made 80 all as per srl item no. 11.04 here in before but from 85 m below ground level to 110 m depth below ground level. 81 all as per srl item no. 11.04 here in before but from 110 m below ground level to 135 m depth below ground level. 82 material and labour for drilling of 450 mm bore hole from 135 mtr below ground level to 160 mtr depth below ground level in any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes of following diameters complete all as specified and as directed : notes :(a) record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) the bore/tube well should be constructed by the agency as approved by ge (east) fzr.(c) the rates also includes transportation of rig machine & t&p at site.(d) trail bore will be drilled, if sufficient wet strata is available then erw casing will be lowered. in case strata is not available payment only for drilling will be made 83 all as per srl item no. 11.07 here in before but from 160 m below ground level to 185 m depth below ground level. 84 all as per srl item no. 11.07 here in before but from 185 m below ground level to 200 m depth below ground level. 85 material and labour for electrical logging of bore well and after electrical logging report of assembly design and submission of lithological log report for approval of ge complete. 86 supply and fixing 350 mm bore erw mild steel housing pipe 8mm wall thickness duly painted with primer and anti corrosive paint with screwed and socket ends in standard length of 3 metre or as required at site, complete with coupling, welding at joints as required (isi marked : is 4270 1992) including cutting,lowering, jointing and fixing in position, complete all as specified (measured net as fixed). 87 all as per srl item no. 11.11 here in before but 250 mm bore pipe with 8 mm wall thickness. 88 supply and fixing low carbon galvanised iron screen filter (slotted) 250mm bore pipe with slots 0.2 mm to 1.5 mm, 6.4mm wall thickness duly painted with ferrous primer and anti corrosive bituminous paint including screwed and socket ends in standard length, welding and fixing support having slots 0.2 mm to 1.5 mm depending upon nature of aquifers sediments, complete including lowering and fixing in position, confirming to is 4270 1992, complete all as specified (measured net as fixed) 89 supply and fixing mild steel reducing socket for connecting 350mm bore housing pipe with 250mm bore blind pipe with minimum 8.0 mm wall thickness including welding and fixing support complete all as specified and directed 90 supply and fixing mild steel bail plug suitable for 250 mm bore pipe 1.5 metre long having wall thickness of 8.0 mm with strong iron hooks, complete all as specified and directed 91 supply and fixing well cap fabricated out of 6 mm thick mild steel sheet for 350mm bore housing pipe threaded similar to housing pipe with handle made and of 20mm dia mild steel round bar, complete all as specified and directed 92 material and labour for mild steel flat iron 75mmx6mm as centre guides (set of three), standard pattern for 350/250 mm bore housing pipe complete all as specified and directed 93 material and labour for ms clamps made out of flat iron 125mmx12mm and 01 metre long with nut, bolts of 22mm dia of suitable length for 350mm bore housing pipe complete all as specified and directed 94 material and labour for mild steel structural steel e 250 grade 410w (ismb 150) fixed independently without connecting plateincluding two coats of black paint over a coat of red oxide complete all as specified and directed 95 material and labour for strata sample box, made out of 1st class soft wood (deodar) having appropriate internal dimensions 1000mm×600mm×100mm with open able glass shutter using 4mm thick plain sheet glass having pigeon holes as approved, 2 nos butt hinges of suitable size and 75mm long hasp staple 01 no having not less than 25 compartments capable of holding 480 to 540 grams of strata sample, including painting wooden surfaces with two coats of synthetic enamel paint (grey) over a coat of pink primer complete all as specified and as directed 96 material and labour for 10mm thick (structural steel should be fe 290 (grade e 165) mild steel black plate of size 600mm dia & cut into two semi circular equal parts with 350 mm dia hole in the centre complete all as directed by engineer in charge. 97 material and labour for pea gravel of size 1.5mm to 4.5mm packed all around 350mm bore housing pipe and 250mm bore blind pipe, strainer pipe upto entire depth as required at site in newbore well, complete all as specified and directed.note: for the purpose of measurement, gravel brought by the contractor shall be stacked properly at site & measurements of stack shall be carried out before use and after use(left unused) to arrive at the net qty of gravel used by the contractor in the work & payment against this item shall only be made for the qty of gravel used in the work not for the total qty of gravel brought. 98 material and labour for testing and developing the bore well by means of aircompressor5000 psitill sand free clear water discharge is obtained to achieve maximum yield of suitable capacity for first 24 hours running complete all as specified and directednote : all equipments shall be arranged by contractor athis own cost. 99 all as per srl item no. 11.23 here in before but beyond 24 rs. 100 material and labour for yield testing of the tube well by means of engine driven pumping set of suitable capacity, the discharge shall be measured by providing orifice system or ‘v’ notch fixed to steel tank of adequatecapacity complete all as directed by engineer in charge. note : all equipments arranged by contractor at his cost & rates are deemed to be included in quoted rates. 101 testing portability of water by chemical analysis such as ph value, dissolved solids, hardness as caco3 and calcium, magnesium, chlorides, sulphate, nitrate, alkality, iron turbidity ntu, mineral oil, colour hazen units, taste, odour, residual free chlorine, total coliform per 100mm (microbiological test) and e coli as per 100ml (microbiological test) as well as bacteriological portability from any govt lab complete all as directed by engineer in charge. 102 supply, installation, commissioningand testing of submersible pump set v 8multistage (as per mfg design stage ( min 4 stage)) electric driven 2900 rpm of capacity not less than 780 lpm at not less than 90mtr head water lubricated suitable for 200/250mm bore and 150 mm dia discharge pipe coupled with squirrel cage induction electric motor 3 phase 415 volts of capacity not less than 30 hp having ci casing & gun metal impeller fitted with delivery pipe etc as reqd at sitewith suitableelectric motor, b class insulation, ip 68 protection and electric connection with following moc: stainless steel impeller, stainless steel pump shaft, ltb pump bushes, cast iron bowl/stage casing; complete all as directed by engineer in charge. 103 supply and fixing flat submersible cable pvc multi stranded copper conductor 3 core 16 sqmm from lt panel/ star delta starter to pump motors complete all as directed by engineer in charge. 104 supply and fixing mild steel columnpipe heavy duty5.4 mm wallthickness 100 mm dia in 3 m length includingflanged both side including provision of nuts, bolts, gasket etc including lowering and fixing complete all as directed by engineer in charge. 105 supply, installation, testing and commissioning in replacement of cpri approved, factory made, lt panel board cubical, indoor type, floor mounted double door, suitable for ac, 3 phase 4 wire, 50 cycles, 415 volts,front & rear openable double door with locking arrangement. the panel board shall be made of 2.0 mm thick crca/ms sheet (min size 1.2 m x 1.0 m x 0.45 m) with synthetic enamel paint both side.the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm ,gaskets thimbles including cable entry glands, all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl& 1/2 mtr for below gl in pcc (1:3:6) type c 2 using 40 mm stone aggregatescomprising of following: (i) panel having common aluminium bus bar of capacity 400 amp tpn each ( size 40mm x10 mm) and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size(ii) incoming(a) (a) mccb adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 200 amp 4 pole icu= 36 ka with overload variation 40 100% 01 no(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 100 amp 4 pole icu = ics = 16 ka 01 no.make : abb/siemens/schneider.(outgoing)(b) mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole icu = ics = 16 ka 01 no.make : abb/siemens/schneider.(outgoing)(c) mcb tpn 63 amps 01 nos(d) on load change over switch 200 amps 01 no(e) automatic star delta submersible starter dlx (with short circuit protection) hgs series suitable for 30 35 hp motor provided with protection degree ip 54 and frls internal wiring and extended wide bend coil and in built metering and contactor size is mn 50 and overload relay range 28 a 40 a and tp mcb rating 100 amps and starter should be provided with single phase preventer etc all as directed.(iv) volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no(v) ammeter 0 200 amps digital type square shape 96mm flush mounted with selector switch and cts 200/5 a 1 no.(vi) indicator lamp ryb : 01 set, with suitable ct coil complete 106 supply, installation and testing of heavy duty chemical dosing system plunger type suitable to inject solution upto 25 lph, working pressure 10 kg /cm square comprising dosing pump coupled with three phase electric motor of capacity 0.5 hp,1440 rpm assembled with agitator in one motor , agitator with ss sweep blade duly frp coated, frp tank 150 ltrs capacity, complete unit mounted on heavy duty panited with ms fabricated frame duly anticorrosive paint, with chemical grade pvc nrv including inlet /outlet check valve all connections ,connecting cpvc/upvc/pvc fittings ,pipe etc complete all as required at site and as directed by engineer in charge. 107 stp works 108 design, supply, construction, installation, testing & commissioning of sewage treatment plant 100 kld based on principle of aerobic attached growth non clogging randomly moving bed bio reactor (mbbr) prefab type, including required foundations and & covering of all motors with ms sheets covers & the following : (a) one no. fine bar screen chamber fitted with screen of ms epoxy construction as per given minimum specifications, to be installed in fine barscreen chambers, provided at an angle of 60° to prevent floating objectspassing through it and subsequently removing manually and dumped forfurther disposal(b) one no. oil & grease removal chamber in rcc construction with design mix concrete of grade m 30, for removal of free floating oil & grease in the sewage, as per given specifications(c) one no. equalisation tank in rcc construction with design mix concrete of grade m 30, as per given specifications, to cater for the peak discharge including provision of diffused air to ensure that septic conditions do notoccur in tank at all. one lot of air grid for equalization tank for providingaeration in the tank, as specified in ps.(d) two nos. raw sewage pumps complete with motor and all necessaryaccessories and fittings, to be installed for transferring sewage fromequalization tank to process reactor. level sensor should be provided in the tank and interlinked with pumps for on off operation as per water level in the tank. one pressure gauge for each pump has to be provided to measure pressure at the outlet.(e) two nos. air blower complete with motor and all necessary accessoriesupply and fixingittings, for providing air in equalization tank, mbbr reactors & sludge holding tank. one no. air rotameter is to be provided in each line to mbbr reactor 1 & 2, & eqt for measurement of quantity of air.(f) one lot of anoxic chamber in msep construction with internals comprising of media and msep mixer. 109 (g) two lot of mbbr tank in msep construction with internals comprising of media, ss air grid & ss rise pipe, media retaining sieves, etc.(h) one lot of tube settler tank in msep construction with internals comprising of media, supporting structure & collection trough.(j) two nos. sewage centrifugal mono block self priming recirculation pumps complete with motor and all necessary accessories and fittings. one pressure gauge for each pump is provided to measure pressure at the outlet.(k) one no. chlorine contact cum filter feed tank in in msep construction, as per given specifications. with one set of chlorine dosing system comprising of solution tank and dosing pumps, as specified in ps, with necessary connection for dosing of solution in chlorine contact tank.(l) two nos. filter feed centrifugal monobloc pumps complete with motor and all necessary accessories and fittings for feeding tertiary unit, level sensor should be provided in the chlorine contact cum filter feed tank andinterlinked with pumps for on off operation as per level in the sump. onepressure gauge for each pump is provided to measure pressure at theoutlet(m) one no. dual media filter, complete with media, frontal piping, valve andpressure gauges to measure pressure across the filter.(n) one no. activated carbon filter of, complete with media, frontal piping, valve and pressure gauges to measure pressure across the filter(o) one no. treated water tank in msep construction, to receive supernatant coming from tertiary treatment plant, as per given specifications(p) two nos. sludge transfer self priming mono block pumps complete with motor and all necessary accessories and fittings. one pressure gauge for each pump has to be provided to measure pressure at the outlet 110 (q) one no. continuous feed sludge screw press with dosing system for sludge dewatering system as specified in ps(r) one no. mcc panel for operation of all electromechanical units of sewage treatment plant(s) one lot of suitable size piping & valves of suitable material to interconnect various units as per site layout.(t) one lot of power & control cables to interconnect various drives and instrumentations with stp panel.(u) one lot of foundations in pcc for all e&m equipment, as required.note :the prices for design, supply,construction, installation, testing and commissioning of 100 kldstp based on mbbr technologyincluding all civil, electromechanical andinstrumentation works as per thespecifications given in technical specification including requiredfoundations. 111 supply and fixing of non clog centrifugal sewage pump having 20 mtr head, capable of delivering approx. 937.5 lpm at 20 mtr head with 10 hp ac electric motor 3 phase, 415v, 50c/s, 1450rpm directly coupled on a common base frame complete all as directed by engineer in charge. make: kirloskar/ ksb/ crompton 112 supply and fixing cast iron foot valve flanged end conforming to is 4038 pn 0.2, 100 mm (4”) dia size all as specified and directed 113 supply, installation, testing and commissioning in replacement of cpri approved, factory made, lt panel board cubical, indoor type, floor mounted double door, suitable for ac, 3 phase 4 wire, 50 cycles, 415 volts,front & rear openable double door with locking arrangement. the panel board shall be made of 2.0 mm thick crca/ms sheet (min size 1.2 m x 1.0 m x 0.45 m) painted with synthetic enamel paint both side.the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm, gaskets thimbles including cable entry glands, all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl& 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregatescomprising of following: (i) panel having common aluminium bus bar of capacity 400 amp tpn each ( size 40mm x10 mm) and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size(ii) incoming(a) mccb adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 100 amp 4 pole icu= 16 ka with overload variation 40 100% 01 no(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole icu = ics = 16 ka 02 nos (c) mcb spn 32 amps 01 no(d) on load change over switch 100 amps 01 no(e) automatic star delta submersible starter asd (with short circuit protection) hsg series suitable for 10 12.5 hpmotor provided with protection degree ip 54 and frls internal wiring and extended wide bend coil and in built metering and contactor size 18 and overload relay range 8 a 12 a and class h insulation and starter should be provided with single phase preventer etc all as directed.(iv) volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no(v) ammeter 0 200 amps digital type square shape 96mm flush mounted with selector switch and cts 200/5 a 1 no.(vi) indicator lamp ryb :01 set. with suitable ct coil complete 114 outsourcing of manning / operation & routine periodical maintenance of electro mechanical equipment’s, control valves, instrumentals etc of stp 100 cum/day (for two shifts per day including sunday & holiday, by employing one fgm (semi skilled operator) and one helper per shift (each shift of eight hours) and maintaining desired level of bod/cod, tss, tkn by dosing of required quantity of chemicals as per oem recommendation complete for a period of 11 months starting from the next day of certified date of completion of phase i (to be intimated by ge through work order separately) complete all as specified and directed.note : (a) maintenance of log sheet and all maintenance records shall be responsibility of the contractor and no stationary shall be provided by the department. format of log sheet and records etc shall be decided by ge/ engineer in charge(b) the contractor is responsible to maintain the installations and surrounding area in presentable manner through out the period. the shift timings shall be decided by engineer in charge and liable to change as and when required by engineer incharge.(c) area cleaning surrounding the plant room & inside the plant room etc shall be responsibility of the contractor (d)the contractor shall be maintain clear record of attendance for workmen/ staff. (e) consumables i.e grease, lubricant oil, cotton waste washers etc required for routine maintenance of stp shall be provided by contractor and cost of the same shall be deemed to be included in unit rates quoted.(f) cost of stationary required for attendance register, meter readings, site order books, log sheets etc shall be provided by contractor and cost of same shall be deemed to be included in unit rates quoted by contractor.(g) fgm/ operator should be iti qualified in respective trade i.e. electrical/ fitter and having minimum 2 years experience in similar trade/ works.(h) helper should be having 2 years experience in similar trade(j) timing of shift shall be as decided by engineer in charge and as specified . 115 treated sewage water supply works 116 supply and fixing 3 phase horizontal, radially split volute casing centrifugal pump 3 hp in back pull out design, single stage, single entry with radial impeller equipped with vfd devices & equipped with speed control panel to control speed/ discharge pump set capacity of discharge 500 lpm at delivery head of 22mtr of ie 3* & with moc material ci/ bronze with suitable electrical panel, cable & starter complete all as directed by engineer in charge. 117 supply and fixing motor starter for 3 hp pumping sets, centrifugal, electric driven having extended wide bend, coil, frls internal wiring, providing with protection degree ip 54, starter type air break, class h insulation complete all as directed by engineer in charge. 118 supply and fixing ppr gate valves (brass insert) of 160mm bore complete all as specified and directed 119 supply and fixing ppr gate valves (brass insert) of 75mm bore complete all as specified and directed 120 supply and fixing cast iron air valve with single air outlets, conforming to is : 14845 of size 50mm bore and fixing up in cast iron water supply mains of size 100mm bore complete all as specified and directed 121 supply and fixing cast iron air valve with single air outlets, conforming to is : 14845 of size 50mm dia and fixing up in cast iron water supply mains of size 150mm dia complete all as specified and directed ...

Punjab Water Resources Management And Development Corporation Limited - Punjab

35467627 tender for supply of bch make freedom series contactor , bch make 40 amp duros freedom series 3 pole ac control contactor size g cat noce15gn 3 , bch make 50 amp duros freedom series 3 pole ac control contactor size h cat noce15hn 3 nb , bch make ct operated overload relay range 37.6 60.0 amp cat no ct 2 mc305ana3c , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 7 / 16 mm...

Punjab Water Resources Management And Development Corporation Limited - Punjab

35380276 tender for supply kit kat and bch timer pack e , l&t make 3 pole power contactor mnx 70 amp type fr 3 cat no cs97096 , l&t make thermal overload relay type mn5 range 45 75 amp cat no ss94137oojo , bch make pneumatic timer timedelay relay time range 0.05 60 sec cat no krtpn10 1 ac control , fuse unit gkh kit kat porcelain rewirable type conform to is2086 / 93200 amp 415 volt with extension strip , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 19 / 16 mm , copper thimble 200 amp...

Punjab State Power Corporation Limited - Punjab

35313520 procurement of electrical material for ubdc power houses 1 mnx 70 contactor for dewatering motor 2 mnx 50 contactor for drainage pump motor 3 mccb dn 0 160 amp for main supply protection 4 ml 6 contactor complete for governor pump motor stage i & ii 5 ml 6 spare kit for governor pump motor stage i & ii 6 overload relay 66 110 amp for fire extinguisher motor starter stage 2...

Punjab Water Resources Management And Development Corporation Limited - Punjab

34730362 tender for supply of material bch contactor freedom series , bch make 40 amp duros freedom series 3 pole ac control contactor size g cat noce15gn 3 , bch make 50 amp duros freedom series 3 pole ac control contactor size h cat noce15hn 3 nb , bch make ct operated overload relay range 37.6 60.0 amp cat no ct2 mc305ana3c , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 7 / 16 mm...

Punjab Water Resources Management And Development Corporation Limited - Punjab

34730353 work: e tenders are invited for the material required for running and maintenance of tube / wells of various blocks of this division from reputed manufactures / firms registered with e procurement portal with punjab govt material l and t overload relay and kit kat tender for material l andt overload relay and kit kat , l&t make thermal overload relay type mn5 range 45 75 amp cat no ss94137oojo , fuse unit gkh kit kat porcelain rewirable type conform to is2086 / 93200 amp 415 volt with extension strip , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 19 / 16 mm...

Punjab Water Resources Management And Development Corporation Limited - Punjab

34544959 material required for running and maintenance of tube / wells of various block under divisional engineer, opt. & maint. division, pwrm&dc ltd: hoshiarpur. 1 bch make pneumatic timer pn timer 0.05 60 sec 1no+1nc cat no. krtpn10.1 2 bch make ct operated overload relay individual mounting range 24.4 39.0 ct1mc30sana3c 3 bch make ct operated overload relay individual mounting range 37.6 60.00 ct2mc305ana3cfor hoshiarpur / mahilpur / garhshankar...

Water Resources Department - Punjab

34494994 material required for running and maintenance of twells of dinanagar and narot jaimal singh block of tubewell division pwrmdc ltd pathankot , bch make 40amp nhd series 4 pole contactor size 1 cat n01n , bch make 40amp duros freedom pole ac control contactor size g cat no. ce15gn3 , bch make ct operated overload relay range 24.4 to 39amp cat no. mc305ana3c...

Water Resources Department - Punjab

34494970 material required for running and maintenance of twells of dinanagar and narot jaimal singh block of tubewell division pwrmdc ltd pathankot , l&t make 3 pole contactor type ml 2size fr 2 cat no.ss90701 , bch make ct operated overload relay range 24.4 to 39 amp cat no. ct i mc305ana3c...

Water Resources Department - Punjab

34494960 material required for running and maintenance of twells of dinanagar and narot jaimal singh block of tubewell division pwrmdc ltd pathankot , l&t make 3 pole power contactor type mnx 70 size fr 3 cat no. cs97076 , overload relay l&t 20 to 42 amp....