Punjab Water Resources Management And Development Corporation Limited - Punjab

37941062 e tenders are invited for the material required for running and maintenance of tube wells of various blocks of opt. and maint. division pwrmdc ltd hoshiarpur , l&t make 3 pole power contactor type ml 6 size fr 3 cat no. ss90921 , l&t make thermal overload relay type mn 5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur / mahilpur / garhshankar...

Water Resources Department - Punjab

37868950 e tenders are invited for the material required for running and maintenance of t / wells of block balachaur and saroya of dist. sbs nagar , sub cable 16 mm23 core copper conduct as per isi 694 1990 , kit kat 200 amp with connection pati , pvc wire 19 / 64copper , pvc wire 7 / 64copper , voltmeter , amperemeter , single phase preventor , overload relay 45 to 75 amp , contactor ml4 ( 415 volt ) , overload relay 66 to 110 amp , overload relay 37 to 60 amp , sub cable 10 mm23 core copper conduct as per isi 694 1990 , sub cable 25 mm23 core copper conduct as per isi 694 1990 , spare kit ml4 , electronic timer typest 100 cat no. st803280000 , contactor ml3 , spare coil ml4 , contactor ml6 , spare kit ml6 , fornurpur bedi block of distt ropar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37830500 e tenders are invited for the repair and rewinding of submersible motor pumps of the following tubewells in various block of distt. hoshiarpur under opm division hoshiarpur , l&t make 3 pole power contactor type ml 6 size fr 3 cat no. ss90921 , l&t make thermal overload relay type mn 5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur/ mahilpur/garhshankar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37691139 e tenders are invited for the repair and rewinding of submersible motor pumps of the following tubewells in various block of distt. hoshiarpur under opm division hoshiarpur , l&t make 3 pole power contactor type ml 6 size fr 3 cat no. ss90921 , l&t make thermal overload relay type mn 5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur/ mahilpur/garhshankar...

Water Resources Department - Punjab

37625707 tender for material required for running and maintenance of twells under tubewell division pwrmdc ltd pathankot l&t make 3 pole power contactor type ml 2 size fr 2cat no. ss90701 , overload relay l&t 28 to 42 amp....

Water Resources Department - Punjab

37625703 tender for material required for running and maintenance of twells under tubewell division pwrmdc ltd pathankot 1 l&t make 3 pole power contactor type ml 2 size fr 2cat no. ss90701 2 overload relay l&t 28 to 42 amp...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37566862 e tenders are invited for the repair and rewinding of submersible motor pumps of the following tubewells in various block of distt. hoshiarpur under opm division hoshiarpur , l&t make 3 pole power contactor type ml 6 size fr 3 cat no. ss90921 , l&t make thermal overload relay type mn 5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur / mahilpur / garhshankar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37406488 e tenders are invited for the repair and rewinding of submersible motor pumps of the following tubewells in various block of distt. hoshiarpur under opm division hoshiarpur , l&t make 3 pole power contactor type ml 6 size fr 3 cat no. ss90921 , l&t make thermal overload relay type mn 5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur/ mahilpur/garhshankar...

Bhakra Beas Management Board - Punjab

37393007 bids are invited for contactor mse mnx r5 thermal overload relay , fn 630 switch disconnector fuse unit 630 a , spare contact kit of contactor mnx 325 , timer y upon triangle cat no 2asdto , spare coil , spare contact kit of contactor , mn2 thermal over load relay , spare contact kit of contactor mnx140 , incomer 400a tp mccb dn3b 400 d , spare contact kit of contactor mnx 185 , tape wound panel current transformers , spare contact kit of contactor mnx 400 , mn2 thermal overload relay , mn5 thermal overload relay , contactor kit , contactor kit , over load relay , main switch make l and t fn 100 , main switch make l and t fn 125 , contactor total quantity : 94...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37346014 e tenders are invited for the material required for running and maintenance of tube /wells of various blocks of this division l&t make thermal overload relay type mn5 range 66 110 amp cat no ss94137ooko , l&t make spare contact kit type ml 4 cat noss95311 , l&t make 3 pole power contactor type ml 4 size fr 3cat no ss90910...

Punjab Water Resources Management And Development Corporation Limited - Punjab

37118795 e tenders are invited for the material required for running and maintenance of tube /wells of various blocks of this division l&t make thermal overload relay type mn5 range 45 75 amp cat no ss94137oojo , l&t make spare contact kit type ml 3 cat noss95309 , l&t make 3 pole power contactor type ml 4 size fr 3cat no ss90910...

Punjab Water Resources Management And Development Corporation Limited - Punjab

36598825 e tenders are invited for the material required for running and maintenance of twells of various blocks of opt and maint division pwrmdc ltd hoshiarpur , l&t make 3 pole power contactor type ml 4, 70 amp. size fr 3 cat no. ss90910. , l&t make thermal overload relay mn5 range 45 75 amp. cat no. ss9413700jo , l&t make thermal overload relay mn5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur / mahilpur / garhshankar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

36448531 e tenders are invited for the material required for running and maintenance of twells of various blocks of opt and maint division pwrmdc ltd hoshiarpur , l&t make 3 pole power contactor type ml 4, 70 amp. size fr 3 cat no. ss90910. , l&t make thermal overload relay mn5 range 45 75 amp. cat no. ss9413700jo , l&t make thermal overload relay mn5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur/ mahilpur/ garhshankar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

36448530 e tenders are invited for the material required for running and maintenance of twells of various blocks of opt. and maint. division pwrmdc ltd hoshiarpur , l&t make 3 pole power contactor type ml 3 size fr 2 cat no. ss90721 , bch make 73 amp. duros freedom series 3 pole ac control contactor size g cat no. ce15kn 3 , bch make ct operated overload relay range 37.6 60.0 amp cat no ct2 mc305ana3c , fuse units gkh (kit kat) porcelain type confirm to is:2086/93 rewirable fuse and base career 200 amp. 415 volt with extension strip. , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 19/16mm for hoshiarpur/ mahilpur/garhshankar...

Water Supply And Sanitation Department - Punjab

36219476 tender for supplying and fixing automatic star delta submersible control panelsuitable for 20 25 hp submersible motor comprising of main switch digital voltage meter with auto 3 phase rotation r.y y.b, br digital ampere meter, single phase preventer overload relay with range 20 to m32 amp having push button for star run and stop functions housed in powder coated sheet steel enclosure. sailbrah...

Water Supply And Sanitation Department - Punjab

36219453 tender for supplying and fixing automatic star delta submersible control panelsuitable for 20 25 hp submersible motor comprising of main switch digital voltage meter with auto 3 phase rotation r.y y.b, br digital ampere meter, single phase preventer overload relay with range 20 to m32 amp having push button for star run and stop functions housed in powder coated sheet steel enclosure....

Water Supply And Sanitation Department - Punjab

36219381 supplying and fixing automatic star delia submersible control — panel suitable for 20 25 1w submersible motor comprising of main switch: digital voltage meter with auto 3 phase rotation ry. yb, br: digital ampere meter: single phase preventer; overload relay with range 20 to 32 amp. having pnh button for start. riai and stop functions: housed in powder coated sheet steel n enclosure....

Punjab Water Resources Management And Development Corporation Limited - Punjab

36104850 e tenders are invited for the material required for running and maintenance of t / wells of various blocks of this division from reputed manufactures / firms registered with e procurement portal with punjab govt., as per detail given below l&t make 3 pole power contactor type mnx 40 sizefr 2 cat no cs94190 2 l&t make spare contact kit type mnx 40 cat nocs94147 3 l&t make thermal overload relay type mn5 range 66 110 amp cat no ss94137ooko 4 pvc shalimar make coppe wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 7 / 16 mm ...

Punjab Water Resources Management And Development Corporation Limited - Punjab

36104841 e tenders are invited for the material required for running and maintenance of t / wells of various blocks of this division from reputed manufactures / firms registered with e procurement portal with punjab govt., as per detail given below l&t make thermal overload relay type mn5 range 45 75 amp cat no ss94137oojo 2 l&t make spare contact kit type mnx 110 cat nocs94154 3 l&t make 3 pole power contactor type ml 4 size fr 3cat no ss90910 ...

Military Engineer Services - Punjab

35740784 providing of ph i of otm accn for mech inf bn at ferozepur under ge ( east ) ferozepur cantt 1 note: (i) please refer schedule a notes given on serial page no. 21 to 27 of tender documents. 2 lumpsum/ other pre priced provisional schedules of works 3 lump sum price worked out by the contractor for building works as listed in schedule a part i brought forward from serial page no. 29. 4 lump sum price worked out by the contractor for site clearance and earthworks as listed in schedule a part ii brought forward from serial page no. 30. 5 lump sum price worked out by the contractor for internal electrification works as listed in schedule a part iii brought forward from serial page no. 37. 6 lump sum price worked out by the contractor for internal water supply works as listed in schedule a part iv brought forward from serial page no. 38. 7 lump sum price worked out by the contractor for sewage disposal works as listed in schedule a part v brought forward from serial page no. 40. 8 lump sum price worked out by the contractor for road, pathand culverts works as listed in schedule a part vi brought forward from serial page no. 42. 9 lump sum price worked out by the contractor for area drainage works listed in schedule a part vii brought forward from serial page no. 43. 10 lump sum price worked out by the contractor for boundary wall, compound wall,fencing and gate works listed in schedule a part viii brought forward from serial page no. 45. 11 lump sum price worked out by the contractor for external water supplyworks as listed in schedule a part ix brought forward from serial page no. 46. 12 lump sum price worked out by the contractor for external electrificationworks as listed in schedule a part x brought forward from serial page no. 50. 13 lump sum price worked out by the contractor for dg set works as listed in schedule a part xi brought forward from serial page no. 51. 14 lump sum price worked out by the contractor for summer appliances worksas listed in schedule a part xii brought forward from serial page no. 53. 15 lump sum price worked out by the contractor for rain water harvesting worksas listed in schedule a part xiii brought forward from serial page no. 54. 16 lump sum price worked out by the contractor for hot water supply works as listed in schedule a part xiv brought forward from serial page no. 56. 17 lump sum price worked out by the contractor forlightening conductor works as listed in schedule a part xv brought forward from serial page no. 57. 18 lump sum price worked out by the contractor for bore well works as listed in schedule a part xvi brought forward from serial page no. 58. 19 lump sum price worked out by the contractor for stp works as listed in schedule a part xvii brought forward from serial page no. 59. 20 lump sum price worked out by the contractor for treated sewage water supply works as listed in schedule a part xviii brought forward from serial page no. 60. 21 lump sum price worked out by the contractor for pcc hard standing works as listed in schedule a part xix brought forward from serial page no. 61. 22 schedule a part xx misc items internal electrification works 23 supply and fix energy efficient led bulb, b229 watt complete all as specified and directed. make: cat no lhldbweb4l8r009 of havells or eqvt in philips and cg. 24 supply and fix modular rj telephone socketcomplete all as specified and directed by engr in charge. make: cat no / sap code ahlkhww000 of havells or eqvt in legrand/ schneider. 25 supply and fix modular tv socket complete all as specified and directed by engr in charge.cat no /sap code ahlkt0w000 of havells or eqvt in legrand/ schneider. 26 supply and fixdecorative 9w ledwall mounting fittings complete set including 9 w led lamp all as specified and directed. make: cat no lhf0eceitzib014 glaze wall light of havellsor eqvt in philips / crompton. 27 s&f gi pipe bracket made out of gi pipe light grade 32 mm dia and bend to shape 1.5 mtr long ms clamps made out of ms flat iron of size 25x4 mm thick with nuts & bolts, washers complete as specified and directed 28 supply and fix wall mounting fan industrial type 450mm sweep, 230v, 50hz , 1400 rpm, 100w, 150cum/hr air delivery, copper motor, double ball bearing , 60db 65db nosie level, upward and down adjustable, 60 degree oscillation degree, 3 nos metal balde guarded with 112 spokes metal case complete with mountings accessories kit, wall bracket, nut, bolt washer etc with connection pvc three core copper wire all as specified and directed. make: cat no fhacwstscl18 of havells or eqvt in legrand/ philips. 29 sewage disposal works 30 material and labour for laying dwc hdpe 150mm (i/d) sn8 pipe including all necessary fittings for carrying sewage complete all as directed by engineer in charge. 31 material and labour for laying dwc hdpe 200mm (i/d) sn8 pipe including all necessary fittings for carrying sewage complete all as directed by engineer in charge. 32 material and labour for construction of under gournd sump cum pump house complete all as shown on drawings and as specified. (drg no cejz 04/2000 sheet no. 1/2 to 2/2). 33 road, pathand culverts works 34 material and labour for cat eye abs plastic with nail of size 100mm x 100mm, 20mm reflective glass colour white/ red/ yellow provided with steel zinc plated with bolt of 12mm dia length 120mm for fixing on road by hammering complete all as directed by engineer in charge. 35 material and labour for delineator 47mm dia 600mm long with high intensity reflective sheeting complete all as directed by engineer in charge. 36 external water supply works 37 supplying, laying, jointing and testing in trenches centrifugally cast 150mm bore ductile iron pipe class k 7 conforming to is : 8329 2000 of min wall thickness 5.4mm including testing complete all as specified. 38 supplying, laying, jointing and testing in trenches centrifugally cast 100mm bore ductile iron pipe class k 7 conforming to is : 8329 2000 of min wall thickness 5.4mm including testing complete all as specified notes for srl no. 6.01 & 6.02 : (a) excavation, earth work and di fittings shall be measured and paid for separately under respective items(b) cost of tyton joints is included in the rate quoted.(c) standard length of the pipe should be 5.50m or 6.0m as available.(d) the measurement of the pipe shall be net as fixed between the fittings including short length without any allowance for cutting and wastage and for the portion entering in the socket of all pipes and fittings.(e) predespatch inspection & testing of di pipe shall be carried out by the representative of ao. all the expenditure for the same shall be borne by the contractor and the quoted rates shall be deemed to be included for the same 39 supply, fixing and testing ductile iron fittings such as bends (any type radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘y’ junction. double branch, cross (all sockets or sockets and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket. spigot caps and plugs suitable for 100 to 150mm ductile iron pressure pipes of k 7 classification and push on flexible rubber gasket joints complete all as specified and directednotes :(a) di fittings shall be of same make as of di pipes or of make as recommended by manufacturers(b) the weight of the fittings shall be measured and paid as given in relevant is or actually provided whichever is less.(c) all fittings shall be relevant is stamping marking.(d) excavation and earth work shall be measured and paid for separately.(e) cost of the joints and jointing materials shall be deemed to be included in the relevant items of di pipes here in before 40 construction of brick masonary valve pit chamber of 1050mm x 750mm x 1000mm size (internal dimensions) with ms sheet cover 6mm thick and angle iron 40mm x 40mm x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified and shown on drgs. breakdown of qtyexternal water supply 4 (each)treated sewage water supply 2 (each) 41 construction of brick masonary valve pit chamber of 900 x 900 x 1000mm size (internal dimensions) with ms sheet cover 6mm thick and angle iron 40 x 40 x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified andshown on drgs. breakdown of qtyexternal water supply 5 (each)treated sewage water supply 3 (each) 42 construction of brick masonary valve pit chamber of 600mm x 600mm x 1000mm size (internal dimensions) with ms sheet cover 6mm thick and angle iron 40mm x 40mm x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified andshown on drgs. note for srl item no. 6.04 to 6.06: 43 supply and fixing rcc water main route indicator of size 75cm x 40cm x 10cm duly marked with mes water mains bore made of cement concrete (1:2:4) type b 1 as in foundation of electric poles/ struts etc including necessary form work, fair, finished embedded in pcc bed including necessary excavation and re filling, proposed to be installed after 25m on pipe lines of size 150mm, 100mm, 80mm and 50mm complete all as directed by engineer in charge. 44 external electric supply works 45 supply ,install, testing and commissioning power factor control lt panel board (apfc) of 200 kvar, 433 volt, 50 cycle per second cubical type front and back openable double leaf type dust & vermin proof with locking arrangement powder coated with approved colour , made out of crca sheet 14 swg, outdoor herewith canopy, cable entry glands, double compressor type, duly prewired with suitable pillar made out of 50 mmx 50mm x6 mm angle iron grouted in and including pcc (1:2:4) using 20 mm graded stone aggregate complete all as per is 8623 1933 & all as per latest isi specification and suitable for housing and including following accessories : (a) incoming mccb of 250 amps 36 ka rupturing capacity , 3 pole thermal magnetic release type shunt trip coil 01 no (b) copper bus bar duly insulated with colour coded heat shrinkable sleeve insulation for three phase four wire system of 250 amps capacity rating with suitable size/ type on hygroscopic on combustion track resistance, high strength frp/mc/dmc insulators.(c) capacitor switching contactor of suitable capacity (contractor amps rating shell not be less than 1.5 times nominal current rating, three pole, coil voltage 440 volts, one each for number of capacitor bank , each contractor shell be protected with 10 ka , d curve type (mcb to be provided for 1.33 times kvar i.e. 100 % current capacity of the mpfcs irrespective of the fact that contractor’s rating is 1.5 times) (mccb 25 ka shall be provided for the above 63 amps rating)(d) one set current transformer (cts) of suitable ratio (with secondary of 5 amps ) to be fixed on bus bar of existing panel including connection with 2 core 1.5 sqmm armoured copper conductor complete with gland etc.(e) shunt capacitor mpp type heavy duty 200 kvar distributed in step of 6 steps with configuration (2x12.5 + 1x25 + 3x50) directly connected to maintain power factor at 0.99 or unity, housed in self extinguishing insulated material with built in. 46 supply and fixing 3 core 1.5 sqmm pvc insulated and frls pvc round sheathed copper conductor flexible 1100 volts for connection from junction box to street light fittings complete all as specified and directed. make :polycab/ havells/ finolex/ paragon 47 supply and fixing street light pole cable junction box ip 65 with metric knockouts for cable entry with mcb sp 6 amps,10 ka and the box made out of thermal plastic material suitable for 16/25 sqmm ug cable including clamps bolts, nuts, duly painted etc complete all as and directed by engineer in charge. 48 supply and fixing bracket made out of 40 mm dia gi light grade tubing 1.2 meter long and bent to angle /shape of 120 degree angle at the meddle from vertical fixed with clamps nuts and bolts washers complete all as specified and directed 49 supply and fixing automatic street light switchfor automatic switching of street light/high mast light (timer switch)for three phase loadlight.the digital timer 24 hrs alongwith suitable power contractor as per iec 60947 4 1, including incoming & outgoing mcbs, smc enclosure and support terminal and enclosed in pole/wall mounted factory made pvc enclosure made out of rust proof, shock & termite proof and frls grade confirming to ip 54 of capacity 6 kw, three phase, current rating 32/tp and mcb rating 40/tpn, having facility of manual operation complete all as directed by engineer in charge. 50 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac,3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.8 m x 1.5 m x 1.0 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location main panel (x mer 400 kva)(i) panel having common aluminium bus bar of capacity 1600 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)acb microprocessor released and thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 800 amp 4 pole, 50 kawith overload variation 40 100% 1 no,(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 amp 3 pole, 35 ka with overload variation 40 100% 1 no,(for apfc ) (b) do but 250 amp 1 no, (c) do but 160 amp 1 no, (d) do but 125 amp 02 nos,(e) do but 63 amp 6 nos,(iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 800 amps digital type square shape 96mm flush mounted with selector switch and cts 800/5 a 1 no.(vi) phase indicating lamp led type 03 nos 51 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac,3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location near smbk(i) panel having common aluminium bus bar of capacity 500 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 amp 4 pole, 35 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, 16 ka with overload variation 40 100% 4 nos. (b) do but 32 amp 2 nos, (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 250 amps digital type square shape 96mm flush mounted with selector switch and cts 250/5 a 1 no.(vi) phase indicating lamp led type 03 nos 52 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtrbelow gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location near jco mess(i) panel having common aluminium bus bar of capacity 320 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 160 amp 4 pole, icu=ics=35 kawith overload variation 40 100% 1 no.(iii) outgoing(a) mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 80 amp 4 pole, icu=ics=25 ka with overload variation 40 100% 1 no. (b)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 4 nos. (c)mcb isolator 25 amp spn 10 ka, 240v 01 no, (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 160 amps digital type square shape 96mm flush mounted with selector switch and cts 160/5 a 1 no.(vi) phase indicating lamp led type 03 nos 53 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location near offr mess(i) panel having common aluminium bus bar of capacity 250 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 125 amp 4 pole, icu=ics=25 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 2 nos. (b)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=25 ka with overload variation 40 100% 2 nos. (c)mcb isolator 32 amp spn 10 ka, 240v 04 nos, (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 125 amps digital type square shape 96mm flush mounted with selector switch and cts 125/5 a 1 no.(vi) phase indicating lamp led type 03 nos 54 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location near adm block(i) panel having common aluminium bus bar of capacity 250 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 125 amp 4 pole, icu=ics=25 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 2 nos. (b)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=25 ka with overload variation 40 100% 2 nos. (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 125 amps digital type square shape 96mm flush mounted with selector switch and cts 125/5 a 1 no.(vi) phase indicating lamp led type 03 nos 55 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location mt area panel(i) panel having common aluminium bus bar of capacity 200 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, icu=ics=16 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 4 nos. (b)mcb isolator 25 amp spn 10 ka, 240v 10 nos. (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 100 amps digital type square shape 96mm flush mounted with selector switch and cts 100/5 a 1 no.(vi) phase indicating lamp led type 03 nos 56 supply, installation, testing and commissioning of cpri approved, factory made, lt panel board cubical, outdoor type, floor mounted double door, front & rear openable with locking arrangement, suitable for ac, 3 phase, 4 wire, 50 cycles, 415 volts. the panel board shall be made of 3.15 thick crca/ms sheet (min size 1.4 m x 1.25 m x 0.8 m) painted with synthetic enamel paint both side. the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm with thimbles all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl & 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregates comprising of following: location street light panel(i) panel having common aluminium bus bar of capacity 200 amp tpn each and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size.(ii) incoming(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole, icu=ics=16 kawith overload variation 40 100% 1 no.(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 amp 4 pole, icu=ics=16 ka with overload variation 40 100% 3 nos. (b)on load change over switch 415v in sheet metal enclosures 4 pole of capacity 63 amp. (iv)volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no.(v)ammeter 0 100 amps digital type square shape 96mm flush mounted with selector switch and cts 100/5 a 1 no.(vi) phase indicating lamp led type 03 nosnote srl item no. 7.06 to 7.12: lt panel shall be got tesed from cpri type test for 4000 amp with breaking capacity not less than 65 ka and ip 56 as per is 61439 part 1& 2. 57 supply and fixing of rubber mat (insulation mat) of dimension 1m x 2m and 2 mm thick complete for electrical installation and dg sets panels complete all as directed by engineer in charge. 58 supply and fixing of rubber mat of dimension 1m x 2m and 3 mm thick complete for electrical installation and stp main panels complete all as specified and directed. 59 supply and fixing rcc ht cable route indicator of size 75cmx40cmx10cm duly marked with ht cable made ofcement concreted (1:2:4) type b 1 as in foundation of electric poles/struts/ etc including necessary form work, fair finished embedded in pcc bed including necessary excavation and re filling complete all as specified and directed 60 dg set works 61 supply, installing, commissioning and testing of eco friendly diesel engine driven generating set silent type confirming to cpcb conditions/ norms, 62.5 kva, or next higher capacity as available/manufactured at 0.9 power factor directly coupled alternator & engine. the diesel set shall consist of a diesel engine coupled directly to a matching parts or as recommended/ provided by the manufacturer on a common base frame and thereafter installed in the cpcb approved acoustic enclosure. the complete set conforming to and test certificate as per cpcb norms and as specified) complete without amf control panel standardized by manufacturer, fuel tank with mounting arrangement, flexible exhaust pipe complete with the following: (a) engine (prime mover) : diesel engine 1500 rpm of minimum 84 bhp or recommended by manufacturer turbo charged water cooled,12 volts electric battery start, complete with fly wheel and all standard fitting/ fixtures as per manufacturing practice including suitable engine control panel/ dash board with electronic technometer. lube oil temp and pressure gauges water temp gauge frequency meter (digital type) including safety self starter, alternator, cogged v belt, fuel tank with first fill of lube oil and coolant (as applicable) etc. (b) alternator :alternator ac 3 phase 415 volts 4 wire rated line current for output 62.5 kva, pf 0.8, 1500 rpm insulation class enclosures /spdp self exited self regulated brushes, complete with avr with plus and minus voltage regulation directly coupled to and match the above engine. (c) anti vibration pads for mounting engine, alternator assembly on base frame/plate or as recommended by the manufacturer.(d) base plate made out of structural steel as per manufacturer recommended design/specification.(e) acoustic enclosure of an internal type approved/certified acoustic enclosure (as per cpcb norms for the dg set) to restrict the noise level to 75 db at one meter distance and temp rise with in canopy shall not exceed 7 degree centigradebeyond ambient temp. it shall be made of 16 swg or manufacturer standard norms crca sheet with powder coated finish on outside and provided with non ignitic fire retardant foam as acoustic material. the doors and glass windows shall be ismc. it shall also include the following: (i) silencer/absorption the non resistance, residential and exhaust pipe covered with asbestos rope.(ii) internal wiring with pvc copper conductor cable is 694 marked frls in conduit and fluorescent lamp fittings.(iii) fuel tank of 16 hours cap but not less than made of 14 swg crca sheet duly powder coated and provided with float gauge and fuel float switch.(iv) one no 12 v x 180 ah 25 plates maintenance free batteries as recommended by manufacturer.(f) the exhaust of dg set shall be fitted with emission control devises as per latest cpcb norms and as specified and also contractor shall submit test certificate of dg set as per latest cpcb norms. 62 supply, installing, commissioning and testing of eco friendly diesel engine driven generating set silent type confirming to cpcb conditions/ norms, 40 kva, or next higher capacity as available/manufactured at 0.9 power factor directly coupled alternator & engine. the diesel set shall consist of a diesel engine coupled directly to a matching parts or as recommended/ provided by the manufacturer on a common base frame and thereafter installed in the cpcb approved acoustic enclosure. the complete set conforming to and test certificate as per cpcb norms and as specified) complete without amf control panel standardized by manufacturer, fuel tank with mounting arrangement, flexible exhaust pipe complete with the following: (a) engine (prime mover) : diesel engine 1500 rpm of minimum 51 bhp or recommended by manufacturer turbo charged water cooled,12 volts electric battery start, complete with fly wheel and all standard fitting/ fixtures as per manufacturing practice including suitable engine control panel/ dash board with electronic technometer. lube oil temp and pressure gauges water temp gauge frequency meter (digital type) including safety self starter, alternator, cogged v belt, fuel tank with first fill of lube oil and coolant (as applicable) etc. (b) alternator :alternator ac 3 phase 415 volts 4 wire rated line current for output 40 kva, pf 0.8, 1500 rpm insulation class enclosures /spdp self exited self regulated brushes, complete with avr with plus and minus voltage regulation directly coupled to and match the above engine. (c) anti vibration pads for mounting engine, alternator assembly on base frame/plate or as recommended by the manufacturer.(d) base plate made out of structural steel as per manufacturer recommended design/specification.(e) acoustic enclosure of an internal type approved/certified acoustic enclosure (as per cpcb norms for the dg set) to restrict the noise level to 75 db at one meter distance and temp rise with in canopy shall not exceed 7 degree centigradebeyond ambient temp. it shall be made of 16 swg or manufacturer standard norms crca sheet with powder coated finish on outside and provided with non ignitic fire retardant foam as acoustic material. the doors and glass windows shall be ismc. it shall also include the following: (i) silencer/absorption the non resistance, residential and exhaust pipe covered with asbestos rope.(ii) internal wiring with pvc copper conductor cable is 694 marked frls in conduit and fluorescent lamp fittings.(iii) fuel tank of 16 hours cap but not less than made of 14 swg crca sheet duly powder coated and provided with float gauge and fuel float switch.(iv) one no 12 v x 88 ah 25 plates maintenance free batteries as recommended by manufacturer.(f) the exhaust of dg set shall be fitted with emission control devises as per latest cpcb norms and as specified and also contractor shall submit test certificate of dg set as per latest cpcb norms. 63 summer appliances works 64 supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170v 250v with output voltage stabilized at 230v with accuracy of ±2.5% and of capacity 1.0 kva complete all as directed by engineer in charge. 65 supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170v 250v with output voltage stabilized at 230v with accuracy of ±2.5% and of capacity 2.0 kva complete all as directed by engineer in charge. 66 supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170v 250v with output voltage stabilized at 230v with accuracy of ±2.5% and of capacity 3.0 kva complete all as directed by engineer in charge. 67 supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 250v with output voltage stabilized at 230v with accuracy of ±2.5% and of capacity 5.0 kva complete all as directed by engineer in charge. 68 supply and installed refrigerators, electric driven (single phase) of capacity 220 ltrs frost free, 5 star rated complete all as directed by engineer in charge. 69 supply and installed refrigerators, electric driven (single phase) of capacity 400 ltrs frost free, 5 star rated complete all as directed by engineer in charge. 70 supply and installing desert cooler electric driven (single phase) having nominal air flow capacity of 4000 cum/ hrs 230v made of 20 gauge ms sheet and size not less than 90cm, 78cm x 78cm surface area from top and bottom 62cm x 54cm front grill size including tullu pump with rotary switch (4 speed) 5 amp switch on front side, drain valve including two coats synthetic of enamel paint over a coat of primer complete all as directed by engineer in charge. 71 rain water harvesting works 72 material and labour for gravel packing including jute as filter media 4mm to 6mm size around ms pipe complete all as directed by engineer in charge. 73 material and labour for filling of gravel in trenches of size 6mm to 10mm upto height of 0.50m complete all as directed by engineer in charge. 74 material and labour for filling of gravel in trenches of size 2mm to 4mm upto height of 1.0m complete all as directed by engineer in charge. 75 bore well works 76 material and labour for drilling of 675mm bore hole from ground level to 20 m depth below ground levelin any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes complete all as specified and as directed : notes :(a) record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) the bore/tube well should be constructed by the agency as approved by ge (east) fzr.(c) the rates also includes transportation of rig machine & t&p at site.(d) trail bore will be drilled, if sufficient wet strata is available then erw casing will be lowered. in case strata is not available payment only for drilling will be made 77 all as per srl item no. 11.01 here in before but from 20 m below ground level to 40 m depth below ground level. 78 all as per srl item no. 11.01 here in before but from 40 m below ground level to 60 m depth below ground level. 79 material and labour for drilling of 525 mm bore hole from 60 mtr below ground level to 85 mtr depth below ground level in any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes complete all as specified and as directed : notes :(a) record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) the bore/tube well should be constructed by the agency as approved by ge (east) fzr.(c) the rates also includes transportation of rig machine & t&p at site.(d) trail bore will be drilled, if sufficient wet strata is available then erw casing will be lowered. in case strata is not available payment only for drilling will be made 80 all as per srl item no. 11.04 here in before but from 85 m below ground level to 110 m depth below ground level. 81 all as per srl item no. 11.04 here in before but from 110 m below ground level to 135 m depth below ground level. 82 material and labour for drilling of 450 mm bore hole from 135 mtr below ground level to 160 mtr depth below ground level in any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes of following diameters complete all as specified and as directed : notes :(a) record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) the bore/tube well should be constructed by the agency as approved by ge (east) fzr.(c) the rates also includes transportation of rig machine & t&p at site.(d) trail bore will be drilled, if sufficient wet strata is available then erw casing will be lowered. in case strata is not available payment only for drilling will be made 83 all as per srl item no. 11.07 here in before but from 160 m below ground level to 185 m depth below ground level. 84 all as per srl item no. 11.07 here in before but from 185 m below ground level to 200 m depth below ground level. 85 material and labour for electrical logging of bore well and after electrical logging report of assembly design and submission of lithological log report for approval of ge complete. 86 supply and fixing 350 mm bore erw mild steel housing pipe 8mm wall thickness duly painted with primer and anti corrosive paint with screwed and socket ends in standard length of 3 metre or as required at site, complete with coupling, welding at joints as required (isi marked : is 4270 1992) including cutting,lowering, jointing and fixing in position, complete all as specified (measured net as fixed). 87 all as per srl item no. 11.11 here in before but 250 mm bore pipe with 8 mm wall thickness. 88 supply and fixing low carbon galvanised iron screen filter (slotted) 250mm bore pipe with slots 0.2 mm to 1.5 mm, 6.4mm wall thickness duly painted with ferrous primer and anti corrosive bituminous paint including screwed and socket ends in standard length, welding and fixing support having slots 0.2 mm to 1.5 mm depending upon nature of aquifers sediments, complete including lowering and fixing in position, confirming to is 4270 1992, complete all as specified (measured net as fixed) 89 supply and fixing mild steel reducing socket for connecting 350mm bore housing pipe with 250mm bore blind pipe with minimum 8.0 mm wall thickness including welding and fixing support complete all as specified and directed 90 supply and fixing mild steel bail plug suitable for 250 mm bore pipe 1.5 metre long having wall thickness of 8.0 mm with strong iron hooks, complete all as specified and directed 91 supply and fixing well cap fabricated out of 6 mm thick mild steel sheet for 350mm bore housing pipe threaded similar to housing pipe with handle made and of 20mm dia mild steel round bar, complete all as specified and directed 92 material and labour for mild steel flat iron 75mmx6mm as centre guides (set of three), standard pattern for 350/250 mm bore housing pipe complete all as specified and directed 93 material and labour for ms clamps made out of flat iron 125mmx12mm and 01 metre long with nut, bolts of 22mm dia of suitable length for 350mm bore housing pipe complete all as specified and directed 94 material and labour for mild steel structural steel e 250 grade 410w (ismb 150) fixed independently without connecting plateincluding two coats of black paint over a coat of red oxide complete all as specified and directed 95 material and labour for strata sample box, made out of 1st class soft wood (deodar) having appropriate internal dimensions 1000mm×600mm×100mm with open able glass shutter using 4mm thick plain sheet glass having pigeon holes as approved, 2 nos butt hinges of suitable size and 75mm long hasp staple 01 no having not less than 25 compartments capable of holding 480 to 540 grams of strata sample, including painting wooden surfaces with two coats of synthetic enamel paint (grey) over a coat of pink primer complete all as specified and as directed 96 material and labour for 10mm thick (structural steel should be fe 290 (grade e 165) mild steel black plate of size 600mm dia & cut into two semi circular equal parts with 350 mm dia hole in the centre complete all as directed by engineer in charge. 97 material and labour for pea gravel of size 1.5mm to 4.5mm packed all around 350mm bore housing pipe and 250mm bore blind pipe, strainer pipe upto entire depth as required at site in newbore well, complete all as specified and directed.note: for the purpose of measurement, gravel brought by the contractor shall be stacked properly at site & measurements of stack shall be carried out before use and after use(left unused) to arrive at the net qty of gravel used by the contractor in the work & payment against this item shall only be made for the qty of gravel used in the work not for the total qty of gravel brought. 98 material and labour for testing and developing the bore well by means of aircompressor5000 psitill sand free clear water discharge is obtained to achieve maximum yield of suitable capacity for first 24 hours running complete all as specified and directednote : all equipments shall be arranged by contractor athis own cost. 99 all as per srl item no. 11.23 here in before but beyond 24 rs. 100 material and labour for yield testing of the tube well by means of engine driven pumping set of suitable capacity, the discharge shall be measured by providing orifice system or ‘v’ notch fixed to steel tank of adequatecapacity complete all as directed by engineer in charge. note : all equipments arranged by contractor at his cost & rates are deemed to be included in quoted rates. 101 testing portability of water by chemical analysis such as ph value, dissolved solids, hardness as caco3 and calcium, magnesium, chlorides, sulphate, nitrate, alkality, iron turbidity ntu, mineral oil, colour hazen units, taste, odour, residual free chlorine, total coliform per 100mm (microbiological test) and e coli as per 100ml (microbiological test) as well as bacteriological portability from any govt lab complete all as directed by engineer in charge. 102 supply, installation, commissioningand testing of submersible pump set v 8multistage (as per mfg design stage ( min 4 stage)) electric driven 2900 rpm of capacity not less than 780 lpm at not less than 90mtr head water lubricated suitable for 200/250mm bore and 150 mm dia discharge pipe coupled with squirrel cage induction electric motor 3 phase 415 volts of capacity not less than 30 hp having ci casing & gun metal impeller fitted with delivery pipe etc as reqd at sitewith suitableelectric motor, b class insulation, ip 68 protection and electric connection with following moc: stainless steel impeller, stainless steel pump shaft, ltb pump bushes, cast iron bowl/stage casing; complete all as directed by engineer in charge. 103 supply and fixing flat submersible cable pvc multi stranded copper conductor 3 core 16 sqmm from lt panel/ star delta starter to pump motors complete all as directed by engineer in charge. 104 supply and fixing mild steel columnpipe heavy duty5.4 mm wallthickness 100 mm dia in 3 m length includingflanged both side including provision of nuts, bolts, gasket etc including lowering and fixing complete all as directed by engineer in charge. 105 supply, installation, testing and commissioning in replacement of cpri approved, factory made, lt panel board cubical, indoor type, floor mounted double door, suitable for ac, 3 phase 4 wire, 50 cycles, 415 volts,front & rear openable double door with locking arrangement. the panel board shall be made of 2.0 mm thick crca/ms sheet (min size 1.2 m x 1.0 m x 0.45 m) with synthetic enamel paint both side.the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm ,gaskets thimbles including cable entry glands, all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl& 1/2 mtr for below gl in pcc (1:3:6) type c 2 using 40 mm stone aggregatescomprising of following: (i) panel having common aluminium bus bar of capacity 400 amp tpn each ( size 40mm x10 mm) and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size(ii) incoming(a) (a) mccb adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 200 amp 4 pole icu= 36 ka with overload variation 40 100% 01 no(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 100 amp 4 pole icu = ics = 16 ka 01 no.make : abb/siemens/schneider.(outgoing)(b) mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole icu = ics = 16 ka 01 no.make : abb/siemens/schneider.(outgoing)(c) mcb tpn 63 amps 01 nos(d) on load change over switch 200 amps 01 no(e) automatic star delta submersible starter dlx (with short circuit protection) hgs series suitable for 30 35 hp motor provided with protection degree ip 54 and frls internal wiring and extended wide bend coil and in built metering and contactor size is mn 50 and overload relay range 28 a 40 a and tp mcb rating 100 amps and starter should be provided with single phase preventer etc all as directed.(iv) volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no(v) ammeter 0 200 amps digital type square shape 96mm flush mounted with selector switch and cts 200/5 a 1 no.(vi) indicator lamp ryb : 01 set, with suitable ct coil complete 106 supply, installation and testing of heavy duty chemical dosing system plunger type suitable to inject solution upto 25 lph, working pressure 10 kg /cm square comprising dosing pump coupled with three phase electric motor of capacity 0.5 hp,1440 rpm assembled with agitator in one motor , agitator with ss sweep blade duly frp coated, frp tank 150 ltrs capacity, complete unit mounted on heavy duty panited with ms fabricated frame duly anticorrosive paint, with chemical grade pvc nrv including inlet /outlet check valve all connections ,connecting cpvc/upvc/pvc fittings ,pipe etc complete all as required at site and as directed by engineer in charge. 107 stp works 108 design, supply, construction, installation, testing & commissioning of sewage treatment plant 100 kld based on principle of aerobic attached growth non clogging randomly moving bed bio reactor (mbbr) prefab type, including required foundations and & covering of all motors with ms sheets covers & the following : (a) one no. fine bar screen chamber fitted with screen of ms epoxy construction as per given minimum specifications, to be installed in fine barscreen chambers, provided at an angle of 60° to prevent floating objectspassing through it and subsequently removing manually and dumped forfurther disposal(b) one no. oil & grease removal chamber in rcc construction with design mix concrete of grade m 30, for removal of free floating oil & grease in the sewage, as per given specifications(c) one no. equalisation tank in rcc construction with design mix concrete of grade m 30, as per given specifications, to cater for the peak discharge including provision of diffused air to ensure that septic conditions do notoccur in tank at all. one lot of air grid for equalization tank for providingaeration in the tank, as specified in ps.(d) two nos. raw sewage pumps complete with motor and all necessaryaccessories and fittings, to be installed for transferring sewage fromequalization tank to process reactor. level sensor should be provided in the tank and interlinked with pumps for on off operation as per water level in the tank. one pressure gauge for each pump has to be provided to measure pressure at the outlet.(e) two nos. air blower complete with motor and all necessary accessoriesupply and fixingittings, for providing air in equalization tank, mbbr reactors & sludge holding tank. one no. air rotameter is to be provided in each line to mbbr reactor 1 & 2, & eqt for measurement of quantity of air.(f) one lot of anoxic chamber in msep construction with internals comprising of media and msep mixer. 109 (g) two lot of mbbr tank in msep construction with internals comprising of media, ss air grid & ss rise pipe, media retaining sieves, etc.(h) one lot of tube settler tank in msep construction with internals comprising of media, supporting structure & collection trough.(j) two nos. sewage centrifugal mono block self priming recirculation pumps complete with motor and all necessary accessories and fittings. one pressure gauge for each pump is provided to measure pressure at the outlet.(k) one no. chlorine contact cum filter feed tank in in msep construction, as per given specifications. with one set of chlorine dosing system comprising of solution tank and dosing pumps, as specified in ps, with necessary connection for dosing of solution in chlorine contact tank.(l) two nos. filter feed centrifugal monobloc pumps complete with motor and all necessary accessories and fittings for feeding tertiary unit, level sensor should be provided in the chlorine contact cum filter feed tank andinterlinked with pumps for on off operation as per level in the sump. onepressure gauge for each pump is provided to measure pressure at theoutlet(m) one no. dual media filter, complete with media, frontal piping, valve andpressure gauges to measure pressure across the filter.(n) one no. activated carbon filter of, complete with media, frontal piping, valve and pressure gauges to measure pressure across the filter(o) one no. treated water tank in msep construction, to receive supernatant coming from tertiary treatment plant, as per given specifications(p) two nos. sludge transfer self priming mono block pumps complete with motor and all necessary accessories and fittings. one pressure gauge for each pump has to be provided to measure pressure at the outlet 110 (q) one no. continuous feed sludge screw press with dosing system for sludge dewatering system as specified in ps(r) one no. mcc panel for operation of all electromechanical units of sewage treatment plant(s) one lot of suitable size piping & valves of suitable material to interconnect various units as per site layout.(t) one lot of power & control cables to interconnect various drives and instrumentations with stp panel.(u) one lot of foundations in pcc for all e&m equipment, as required.note :the prices for design, supply,construction, installation, testing and commissioning of 100 kldstp based on mbbr technologyincluding all civil, electromechanical andinstrumentation works as per thespecifications given in technical specification including requiredfoundations. 111 supply and fixing of non clog centrifugal sewage pump having 20 mtr head, capable of delivering approx. 937.5 lpm at 20 mtr head with 10 hp ac electric motor 3 phase, 415v, 50c/s, 1450rpm directly coupled on a common base frame complete all as directed by engineer in charge. make: kirloskar/ ksb/ crompton 112 supply and fixing cast iron foot valve flanged end conforming to is 4038 pn 0.2, 100 mm (4”) dia size all as specified and directed 113 supply, installation, testing and commissioning in replacement of cpri approved, factory made, lt panel board cubical, indoor type, floor mounted double door, suitable for ac, 3 phase 4 wire, 50 cycles, 415 volts,front & rear openable double door with locking arrangement. the panel board shall be made of 2.0 mm thick crca/ms sheet (min size 1.2 m x 1.0 m x 0.45 m) painted with synthetic enamel paint both side.the panel have to provide proper compartment as per is specification and wiring of panel with suitable size of copper conductor frls cable not less than 2.5 sqmm, gaskets thimbles including cable entry glands, all as directed. base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from gl& 1/2 mtr below gl in pcc (1:3:6) type c 2 using 40 mm graded stone aggregatescomprising of following: (i) panel having common aluminium bus bar of capacity 400 amp tpn each ( size 40mm x10 mm) and suitable capacity tpn bus bar for outgoing mccbs, including aluminium lugs to connect the cable and cable gland for each cable entry as per cable size(ii) incoming(a) mccb adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 100 amp 4 pole icu= 16 ka with overload variation 40 100% 01 no(iii) outgoing(a)mccb thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 amp 4 pole icu = ics = 16 ka 02 nos (c) mcb spn 32 amps 01 no(d) on load change over switch 100 amps 01 no(e) automatic star delta submersible starter asd (with short circuit protection) hsg series suitable for 10 12.5 hpmotor provided with protection degree ip 54 and frls internal wiring and extended wide bend coil and in built metering and contactor size 18 and overload relay range 8 a 12 a and class h insulation and starter should be provided with single phase preventer etc all as directed.(iv) volt meter 0 500 volts digital type square shapeflush mounted with selector switch 1 no(v) ammeter 0 200 amps digital type square shape 96mm flush mounted with selector switch and cts 200/5 a 1 no.(vi) indicator lamp ryb :01 set. with suitable ct coil complete 114 outsourcing of manning / operation & routine periodical maintenance of electro mechanical equipment’s, control valves, instrumentals etc of stp 100 cum/day (for two shifts per day including sunday & holiday, by employing one fgm (semi skilled operator) and one helper per shift (each shift of eight hours) and maintaining desired level of bod/cod, tss, tkn by dosing of required quantity of chemicals as per oem recommendation complete for a period of 11 months starting from the next day of certified date of completion of phase i (to be intimated by ge through work order separately) complete all as specified and directed.note : (a) maintenance of log sheet and all maintenance records shall be responsibility of the contractor and no stationary shall be provided by the department. format of log sheet and records etc shall be decided by ge/ engineer in charge(b) the contractor is responsible to maintain the installations and surrounding area in presentable manner through out the period. the shift timings shall be decided by engineer in charge and liable to change as and when required by engineer incharge.(c) area cleaning surrounding the plant room & inside the plant room etc shall be responsibility of the contractor (d)the contractor shall be maintain clear record of attendance for workmen/ staff. (e) consumables i.e grease, lubricant oil, cotton waste washers etc required for routine maintenance of stp shall be provided by contractor and cost of the same shall be deemed to be included in unit rates quoted.(f) cost of stationary required for attendance register, meter readings, site order books, log sheets etc shall be provided by contractor and cost of same shall be deemed to be included in unit rates quoted by contractor.(g) fgm/ operator should be iti qualified in respective trade i.e. electrical/ fitter and having minimum 2 years experience in similar trade/ works.(h) helper should be having 2 years experience in similar trade(j) timing of shift shall be as decided by engineer in charge and as specified . 115 treated sewage water supply works 116 supply and fixing 3 phase horizontal, radially split volute casing centrifugal pump 3 hp in back pull out design, single stage, single entry with radial impeller equipped with vfd devices & equipped with speed control panel to control speed/ discharge pump set capacity of discharge 500 lpm at delivery head of 22mtr of ie 3* & with moc material ci/ bronze with suitable electrical panel, cable & starter complete all as directed by engineer in charge. 117 supply and fixing motor starter for 3 hp pumping sets, centrifugal, electric driven having extended wide bend, coil, frls internal wiring, providing with protection degree ip 54, starter type air break, class h insulation complete all as directed by engineer in charge. 118 supply and fixing ppr gate valves (brass insert) of 160mm bore complete all as specified and directed 119 supply and fixing ppr gate valves (brass insert) of 75mm bore complete all as specified and directed 120 supply and fixing cast iron air valve with single air outlets, conforming to is : 14845 of size 50mm bore and fixing up in cast iron water supply mains of size 100mm bore complete all as specified and directed 121 supply and fixing cast iron air valve with single air outlets, conforming to is : 14845 of size 50mm dia and fixing up in cast iron water supply mains of size 150mm dia complete all as specified and directed ...

Punjab Water Resources Management And Development Corporation Limited - Punjab

35467627 tender for supply of bch make freedom series contactor , bch make 40 amp duros freedom series 3 pole ac control contactor size g cat noce15gn 3 , bch make 50 amp duros freedom series 3 pole ac control contactor size h cat noce15hn 3 nb , bch make ct operated overload relay range 37.6 60.0 amp cat no ct 2 mc305ana3c , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 7 / 16 mm...

Punjab Water Resources Management And Development Corporation Limited - Punjab

35380276 tender for supply kit kat and bch timer pack e , l&t make 3 pole power contactor mnx 70 amp type fr 3 cat no cs97096 , l&t make thermal overload relay type mn5 range 45 75 amp cat no ss94137oojo , bch make pneumatic timer timedelay relay time range 0.05 60 sec cat no krtpn10 1 ac control , fuse unit gkh kit kat porcelain rewirable type conform to is2086 / 93200 amp 415 volt with extension strip , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 19 / 16 mm , copper thimble 200 amp...

Punjab State Power Corporation Limited - Punjab

35313520 procurement of electrical material for ubdc power houses 1 mnx 70 contactor for dewatering motor 2 mnx 50 contactor for drainage pump motor 3 mccb dn 0 160 amp for main supply protection 4 ml 6 contactor complete for governor pump motor stage i & ii 5 ml 6 spare kit for governor pump motor stage i & ii 6 overload relay 66 110 amp for fire extinguisher motor starter stage 2...

Punjab Water Resources Management And Development Corporation Limited - Punjab

34730362 tender for supply of material bch contactor freedom series , bch make 40 amp duros freedom series 3 pole ac control contactor size g cat noce15gn 3 , bch make 50 amp duros freedom series 3 pole ac control contactor size h cat noce15hn 3 nb , bch make ct operated overload relay range 37.6 60.0 amp cat no ct2 mc305ana3c , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 7 / 16 mm...

Punjab Water Resources Management And Development Corporation Limited - Punjab

34730353 work: e tenders are invited for the material required for running and maintenance of tube / wells of various blocks of this division from reputed manufactures / firms registered with e procurement portal with punjab govt material l and t overload relay and kit kat tender for material l andt overload relay and kit kat , l&t make thermal overload relay type mn5 range 45 75 amp cat no ss94137oojo , fuse unit gkh kit kat porcelain rewirable type conform to is2086 / 93200 amp 415 volt with extension strip , pvc shalimar make copper wire stranded with f.r flame retardent insulation isi marked is:694 with latest amendment size 19 / 16 mm...

Punjab Water Resources Management And Development Corporation Limited - Punjab

34544959 material required for running and maintenance of tube / wells of various block under divisional engineer, opt. & maint. division, pwrm&dc ltd: hoshiarpur. 1 bch make pneumatic timer pn timer 0.05 60 sec 1no+1nc cat no. krtpn10.1 2 bch make ct operated overload relay individual mounting range 24.4 39.0 ct1mc30sana3c 3 bch make ct operated overload relay individual mounting range 37.6 60.00 ct2mc305ana3cfor hoshiarpur / mahilpur / garhshankar...

Water Resources Department - Punjab

34494994 material required for running and maintenance of twells of dinanagar and narot jaimal singh block of tubewell division pwrmdc ltd pathankot , bch make 40amp nhd series 4 pole contactor size 1 cat n01n , bch make 40amp duros freedom pole ac control contactor size g cat no. ce15gn3 , bch make ct operated overload relay range 24.4 to 39amp cat no. mc305ana3c...

Water Resources Department - Punjab

34494970 material required for running and maintenance of twells of dinanagar and narot jaimal singh block of tubewell division pwrmdc ltd pathankot , l&t make 3 pole contactor type ml 2size fr 2 cat no.ss90701 , bch make ct operated overload relay range 24.4 to 39 amp cat no. ct i mc305ana3c...

Water Resources Department - Punjab

34494960 material required for running and maintenance of twells of dinanagar and narot jaimal singh block of tubewell division pwrmdc ltd pathankot , l&t make 3 pole power contactor type mnx 70 size fr 3 cat no. cs97076 , overload relay l&t 20 to 42 amp....

Water Resources Department - Punjab

33965709 material required for running and maintenance of tube wells of hargobindpur block under tubewell division pwrmdc ltd pathankot material required for running and maintenance of twells of hargobindpur block under tubewell division pwrmdc ltd pathankot , bch make 40amp nhd series 4 pole contactor size 1 cat n01n , bch make 40amp duros freedom pole ac control contactor size g cat no. ce15gn3 , bch make ct operated overload relay range 24.4 to 39amp cat no. mc305ana3c...

Water Resources Department - Punjab

33930018 material required for running and maintenance of twells of dhar block phase 1 and 2 of tubewell division pwrmdc ltd pathankot , bch make 40amp nhd series 4 pole contactor size 1 cat n01n , bch make 40amp duros freedom pole ac control contactor size g cat no. ce15gn3 , bch make ct operated overload relay range 24.4 to 39amp cat no. mc305ana3c...

Water Resources Department - Punjab

33930014 material required for running and maintenance of twells of pathankot block phase 1 and 2 100nos. nabard scheme dhar block of tubewell division pwrmdc ltd pathankot , 3 pole contactor ml 2 l&t make cat no. ss90701 , overload relay l&t make 28 to 42amp...

Water Resources Department - Punjab

33914273 material required for running and maintenance of twells of dhar block phase 1 and 2 of tubewell division pwrmdc ltd pathankot material required for running and maintenance of twells of dhar block phase 1 and 2 of tubewell division pwrmdc ltd pathankot , 3 pole contactor ml 2 l&t make cat no. ss90701 , overload relay l&t make 28 to 42amp...

Water Resources Department - Punjab

33914266 material required for running and maintenance of twells of dhar block phase 1 and 2 of tubewell division pwrmdc ltd pathankot material required for running and maintenance of twells of dhar block phase 1 and 2 of tubewell division pwrmdc ltd pathankot , bch make 40amp nhd series 4 pole contactor size 1 cat n01n , bch make 40amp duros freedom pole ac control contactor size g cat no. ce15gn3 , bch make ct operated overload relay range 24.4 to 39amp cat no. mc305ana3c...

Water Resources Department - Punjab

33765932 e tenders are invited for the material required for running and maintenance of t / wells of block nurpur bedi of dist. ropar , contactor ml2 cat no. ml 2 cat no. ss90701 , spare kit ml2 cat no. ss 95307 , spare coil ml 2 lt / lk cat no. ss90545 , thermal timer with combination coil cat no. ss90650 , front housing & moving bridge kit ml2 cat no. st23866 , sub cable 6 mm23 core copper conduct as per isi 694 1990 , electronic timer typest 100 cat no. st803280000 , pvc wire 7 / 064copper , kit kat 100 amp with connection pati , contactor bch 32 a freedom series cat no. ce15fnbion , contactor bch 40 a freedom series cat no. ce15gn3 , spare contact set for 40 amp freedom series cat no. 6 65 6 , spare coil for freedom series cat no. mc15kw , overload relay 22 to 30 amp bch cat no. ml305ana3n , overload relay f series 24 to 32 amp bch cat no. ml318ana3t , overload relay f series 22 to 30 amp bch cat no. ml318ana3b , electronic time delay recycling bch type cat no. sbt2000 , fornurpur bedi block of distt ropar...

Water Resources Department - Punjab

33746834 e tenders are invited for the material required for running and maintenance of t / wells of block sh. anandpur sahib of dist. ropar e tenders are invited for the material required for running and maintenance of t / wells of block sh. anandpur sahib of dist. ropar , contactor 32a bch f series cat no.ce15nfb10n , contactor 40 a bch f series cat no.ce15gn03 , spare contact set for 40 a bch f series cat no. 6 65 6 , nhd series 4 pole ac control bch 32 a contactor cat no.no1n , spare contact set nhdseries 32 acat no. sp341l , spare coil forf series bch ( ghjil ) cat no. mc15kw , overload relay 22 to 30 amp bch cat no. ml305ana3n , overload relay 24 to 32 amp f seriesbch cat no. ml318ana3t , sub cable 6 mm2isi 694 1990 3 core copper conduct , voltmeter 0 to 500 volt , kit kat 100 amp with connection pati , electronic time delay recycling bch type cat no. sbt2000 , contactor ml 2 cat no. ss90701 , spare kit ml 2 cat no. ss95307 , thermal timer with connection coil ss90650 , electronic time st100 type lt / lk cat no.803280000 , pvc wire 7 / 064copper , forsh. anandpur sahib block of distt ropar...

Water Resources Department - Punjab

33746788 e tenders are invited for the material required for running and maintenance of t / wells of block balachaur dist. sbs nagar e tenders are invited for the material required for running and maintenance of t / wells of block balachaur dist. sbs nagar , submersible cable 25mm2 as per is 694 1990 standard insulation 3 core copper conduct lt / lk make , overload relay lt / lk 66 to 110 amp ss 9413700 ko , submersible cable 10mm2 as per is 694 1990 standard insulation 3 core copper conduct lt / lk make , spare kit ml 4 ss 95311 , contactor ml 6 ss 90721 , contactor ml 3 ss 90721 , spare kit ml 6 ss 95313 , electronic timer type st 100 st 803280000 3 to 50 sec , forbalachaur &saroya block of distt sbs nagar...

Water Resources Department - Punjab

33719438 e tenders are invited for the material required for running and maintenance of t / wells of block balachaur dist. sbs nagar of this division , submersible cable 16mm2 as per is 694 1990 standard insulation 3 core copper conduct lt / lk make , kit kat 200 amp asco with connection patti , pvc wire 19 / 064 70mm2 , pvc wire 07 / 064 70mm3 , voltmeter , c.t. ampmeter , single phase preventer , overload relay lt / lk 45 to 75 amp ss 9413700 jo , contactor ml 4 ss 90910 , forbalachaur &saroya block of distt sbs nagar...

Water Resources Department - Punjab

33719434 e tenders are invited for the material required for running and maintenance of t / wells of block balachaur dist. sbs nagar , submersible cable 25mm2 as per is 694 1990 standard insulation 3 core copper conduct lt / lk make , overload relay lt / lk 66 to 110 amp ss 9413700 ko , submersible cable 10mm2 as per is 694 1990 standard insulation 3 core copper conduct lt / lk make , spare kit ml 4 ss 95311 , contactor ml 6 ss 90721 , contactor ml 3 ss 90721 , spare kit ml 6 ss 95313 , electronic timer type st 100 st 803280000 3 to 50 sec , forbalachaur &saroya block of distt sbs nagar...

Military Engineer Services - Punjab

33531544 repair / maintenance of non clog submersible pumps and connected items at old amritsar cantt 1. old unserviceable winding wire copper 2. old unserviceable ss impeller, pump shaft 3. old unserviceable scrap iron / cast iron 4. old unserviceable selector switch, mcb, mccb 5. old unserviceable fan belt 6. old unserviceable power contector, overload relay, timer 7. old unserviceable air compressor 8. old unserviceable sluice valve / butter fly valve 80mm, 100mm, 150mm 9. old unserviceable submersible cable 10. old unserviceable sp preventor 11. old unserviceable non returning valve 12. old unserviceable panel 13. old unserviceable di pipe 100 / 150 mm 14. old unserviceable ms pipe 15. old unserviceable water level controller 16. old unserviceable di / ci pipe fittings...

Water Resources Department - Punjab

33485919 e tenders are invited for the material required for running and maintenance of t / wells of block balachaur dist. sbs nagar of this division from reputed manufactures / firms registered with e procurement portal with punjab govt. , submersible cable 16mm2 as per is 694 1990 standard insulation 3 core copper conduct lt / lk make , kit kat 200 amp asco with connection patti , pvc wire 19 / 064 70mm2 , voltmeter , c.t. ampmeter , single phase preventer , overload relay lt / lk 45 to 75 amp ss 9413700 jo , contactor ml 4 ss 90910 , submersible cable 25mm2 as per is 694 1990 standard insulation 3 core copper conduct lt / lk make , overload relay lt / lk 66 to 110 amp ss 9413700 ko , submersible cable 10mm2 as per is 694 1990 standard insulation 3 core copper conduct lt / lk make , spare kit ml 4 ss 95311 , contactor ml 6 ss 90721 , contactor ml 3 ss 90721 , spare kit ml 6 ss 95313 , spare coil ml 4 ss 91258 , electronic timer type st 100 st 803280000 3 to 50 sec , forbalachaur &saroya block of distt sbs nagar...

Water Resources Department - Punjab

33288101 e tenders are invited for the material required for running and maintenance of t / wells of block balachaur dist. sbs nagar of this division from reputed manufactures / firms registered with e procurement portal with punjab govt. , submersible cable 16mm2 as per is 694 1990 standard insulation 3 core copper conduct lt / lk make , kit kat 200 amp asco with connection patti , pvc wire 19 / 064 70mm2 , voltmeter , c.t. ampmeter , single phase preventer , overload relay lt / lk 45 to 75 amp ss 9413700 jo , contactor ml 4 ss 90910 , submersible cable 25mm2 as per is 694 1990 standard insulation 3 core copper conduct lt / lk make , overload relay lt / lk 66 to 110 amp ss 9413700 ko , submersible cable 10mm2 as per is 694 1990 standard insulation 3 core copper conduct lt / lk make , spare kit ml 4 ss 95311 , contactor ml 6 ss 90721 , contactor ml 3 ss 90721 , spare kit ml 6 ss 95313 , spare coil ml 4 ss 91258 , electronic timer type st 100 st 803280000 3 to 50 sec , forbalachaur &saroya block of distt sbs nagar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

33173196 material required for running and maintenance of t / wells of various block under divisional engineer, opt. & maint. division, pwrm&dc ltd: hoshiarpur. 0bch make pneumatic timer pn timer 60 sec etc. bch make pneumatic timer pn timer 60 sec etc. , bch make pneumatic timer pn timer 60 sec 1no+1nc cat no. krtpn10.1 , bch make electronic timer star delta timer type dqr 0.2 20 sec / 1 100 sec. 415 / 240, 110 volt ac cat no. sdt00.0 , bch make ct operated overload relay individual mounting range 24.4 39.0 ct1mc30sana3c , bch make ct operated overload relay individual mounting range 37.6 60.00 ct2mc305ana3cfor hoshiarpur / mahilpur / garhshankar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

33173193 the material required for running and maintenance of t/wells of various blocks of opt. & maint. division, pwrm&dc ltd: hoshiarpur. l and t make thermal overload relay mn5 range 45 75 amp etc. l and t make thermal overload relay mn5 range 45 75 amp etc. , l&t make thermal overload relay mn5 range 45 75 amp. cat no. ss9413700jo , l&t make thermal overload relay mn5 range 66 110 amp. cat no. ss9413700ko for hoshiarpur / mahilpur / garhshankar...

Nawanshahr Cooperative Sugar Mills Limited - Punjab

33127877 tender for electrical material starter, relay & contractor dol starter mk 1 type dol starter mk 2 type relay range dol starter mk 3 type relay range thermal overload relay type mk 1 thermal overload relay type mk 2/3 contractor for dol starter mk 1 kit for mounting mn 5 relay thermal overload relay type mn spare contact kit spare coil(220 volts/440 volts) front housing and moving bridge kit moving bridge assembly for mnx80 contactor contactor mnx45 coil voltage 220 contactor mnx80 for ml6 starter coil voltage 220 automatic star delta ml6 starter combination coil with timper type ml2 cat no. ss90650...

Nawanshahr Cooperative Sugar Mills Limited - Punjab

33127104 purchase of materials 1. dol starter mk i type 2. dol starter ml 2 type relay range 3. dol starter ml 3 type relay range 4. thermal overload relay 5. contactor for dol starter 6. spare contact kit 7. spare coil 8. front housing and moving bridge kit 9. moving bridge assembly 10. automatic star delta ml6 starter 11. combination coil with timer etc....

Indian Army - Punjab

32843034 bids are invited for gear oil , fuse wire , gang box , distilled water , coolant , pvc conduit pipe , grease , casing caping , brake fluid ,cable pvc cooper , motor overload relay total quantity : 637...

Punjab Water Resources Management And Development Corporation Limited - Punjab

32441765 tender for repair and maintenance of tube wells material bch contactor block dasuya tender for rand m of twells material bch contactor block dasuya , bch make ct 2 operated overload relay 37.6 60.0 amp cat no. ct 2 mc305ana3c , bch make e size 70 amp series 3 pole ac control citation series contactor cat no. mc10en22 , bch make d size 40 amp series 3 pole ac control citation series contactor cat no. mc10dn22 , bch make spare magnetic coil cat no. mc15kw...