Rail Coach Factory - Punjab

37889581 supply of 3q power contactor 25a coil voltage 220vac with 1no+1nc make. l&t schneider, bch only. , refrigerant gas r290 with cylinder for split ac make. total line, comipro, godrej only. , refrigerant gas r 32 with cylinder for split ac make. total line, comipro, godrej only. , fan blade 10 for water cooler => limited...

Water Supply And Sanitation Department - Punjab

37697919 tender for operation / maintenance of crash house building at kapurthala service of split ac 1.5 t.r service of split ac 2.5 t.r p/f fan motor of odo of ac refrigerant gas refill for ac 1.0 tr refrigerant gas refill for ac 1.5 tr refrigerant gas refill for ac 2.0 tr p.c.b repair charges for 1 to 2 tr ac repair charges for 1 to 2tr p/f nitrile rubber insulation 10x 16mm on copper pipe with steel grip tape service of window ac 1 to 2 t.r repair of stabilizer...

Punjab State Transmission Corporation Limited - Punjab

37697668 tender for repair of air conditioning plant at 220 kv s/s gndtp bathinda under p&m division pstcl bathinda 1) supply of 44 kg refrigerant gas r 22 2) supply of 1 no. nitrogen gas cylinders of 120 psi pressure 3) labour charges for rectification of minor mechanical faults, & gas leakage including gas filling, service, commissioning and thereafter supervision for 6 months. (4 visits per month)...

Water Supply And Sanitation Department - Punjab

37588338 tender for repair and maintenance of air conditioner of judicial court complex dist, kapurthala, service of split ac 1.5 t.r service of split ac 2 t.r refrigerant gas refill for ac 1.0 tr refrigerant gas refill for ac 1.5 tr refrigerant gas refill for ac 2.0 tr p.c.b repair charges for 1 to 2 tr ac repair charges for 1 to 2 tr service of window ac 1 to 2 t.r repair of stablizer...

Patiala Locomotive Works - Punjab

37490181 supply of refrigerant gas r 32 ( in sealed cylinder of 45 kg. empty cylinder will return to the firm on delivery of gas ) => limited...

Punjab State Transmission Corporation Limited - Punjab

37414371 tender for repair of air conditioning plant at 220 kv s/s gndtp bathinda under p&m division pstcl bathinda: 1) supply of 44 kg refrigerant gas r 22 2) supply of 1 no. nitrogen gas cylinders of 120 psi pressure 3) labour charges for rectification of minor mechanical faults, & gas leakage including gas filling, service, commissioning and thereafter supervision for 6 months. (4 visits per month)....

Water Supply And Sanitation Department - Punjab

36939825 tender for maintenance of session house at kapurthala service of split ac 1,5 t.r service of split ac 2.5 t.r p/f fan motor of odo of ac refrigerant gas refill for ac 1.0 tr refrigerant gas refill for ac 1.5 tr refrigerant gas refill for ac 2.0 tr p.c.b repair charges for 1 to 2 tr ac repair charges for 1 to 2tr p/f nitrile rubber insulation 10x 16mm on copper pipe with steel grip tape service of window ac 1 to 2 t.r repair of stabilizer...

Ministry Of Defence - Punjab

36219154 bids are invited for pneumatic barrel pump ( q3 ) , flate copper cable 6mm x 3 core , flate copper cable 10mm x 3 core , street light junction box kf 2525 upto 25 sqm , multicore round pvc insulated copper condutor flexible indutrial cable 2.5 sqmm 2 core , street light timer 3 phase 5 kw model no 66 8kw3p , street light timer 3 phase 5 kw model no 66 5kw3p , cable terminal boot 95 sqmm 11000 volts , coolant heavy duty , brake fluid , transformer oil isi 335 high volt , hydraulic oil 68 , gear oil 90 , adjustable setting type thermostat small size , adjustable setting type thermostat large size , rubber packing join with having 6 to 9 hole system , air safety plug made out of brass alloy , mcb sp of rating capacity 20 amp 220 415 volts , indicating lamp of color red green round , frls pvc insulated copper cable 2.5 sqmm 3 core , frls pvc insulated copper cable single core size 6 sqmm , frls pvc insulated copper cable single core size 4 sqmm , frls pvc insulated copper cable single core size 16 sqmm , air break power contactor mnx series type of rated current capacity 85 amp 3 phase , directly lope rated power contactor thermal over load relay ml type 3 pole 415 volts , directly lope rated power contactor thermal over load relay ml type 3 pole 415 volts capacity 28 amp to 42 amp , directly lope rated power contactor thermal over load relay ml type 3 pole 415 volts capacity 66 amp to 88 amp , power contractor ml2 type 3pole 415 volt ac 3 rating alng aux contacts , power contractor ml3 type 3pole 415 volt ac 3 rating alng aux contacts , power contractor ml4 type 3pole 415 volt ac 3 rating alng aux contacts , heating element for geyser made out of brass alloy rating capacity 1.5 kw , heating element for geyser made out of brass alloy rating capacity 2.0 kw , heating element for geyser made out of brass alloy rating capacity 3.0 kw , geysers inner assembly complete s per existing size capacity 35ltrs , geysers inner assembly complete s per existing size capacity 50ltrs , brass gum metal vertical type nn return valve check valve of size 15 mm dia , geyser storage hot water inner tank of storage capacity 25ltr , supply of single phase motor actuated butterfly valve size 100mm , supply of single phase motor actuated butterfly valve size 150mm , digital temperature and humidity meter , refrigerant gas leak detector. , digital anemometer , flat copper submersible cable 16m x 3 core , engine oil 20w 40 , pvc insulated copper cable 4 sqmm 2 core , pvc insulated copper cable 6sqmm 4 core , pvc insulated copper cable 10sqmm 4 core , pvc insulated copper cable 16sqmm 2 core total quantity : 4955...

Indian Army - Punjab

35298718 bids are invited for having density 600 kg oblique cum make rajsree, polytech, sintex. , pvc beading 19 mm wide , pvc casing caping 20 mm make anchor, plaza, diplast,dauphin, pelican. , pvc door bend 110 mm bore make prayag, polytuf, shakti , pvc insulated aluminium conductor jumper 11kv rating, length 3 mtrs set of three isi marked , pvc syphon washer for cistern. , pvc washer for bib tap and stop cock pack of 100 , refrigerant gas r 134a , relay over load for water cooler 60 oblique 120 ltrs , relay for voltage stablizer 4 and 5 kva , relay starting with olp for refrigerator isi marked , royal plug 50 mm long pack of 100 , ss spindle suitable for 150mm sluice valve complete with check nut etc make minar, kirloskar, bvi. , ss spindle suitable for 80mm sluice valve complete with check nut etc make minar, kirloskar, bvi. , sand fine , screw wood 35 by 8 200 gm pkt , single disc type insulator polymer type suitable for 11 kv make rashtriya, national, jaipuriya , single phase preventor suitable for 25 to 100 hp electric motor,415 volts 3ph make l and t, minilec , spun yarn for pipes , star delta starter 3 ph,415 volts,40 hp complete with all accessories.make l and t, legrand, havells , syphon assy for geyser 50 ltrs 6 holes make racold, bajaj, havells. total quantity : 1119...

Punjab State Power Corporation Limited - Punjab

35200897 procurement of refrigerant gas mafron m 22 for air conditioning system at ggsstp roopnagar , refrigerant gas m 22 (mafron make) filled in 61 kg factory sealed cylinders (returnable) conf. to is 5610c:1983...

Rail Coach Factory - Punjab

35147251 supply of expansion valve 8t, as per drawing: expansion valve 8t suitable for r 22 & 407 make denfoss or coopland emersonexpansion valve 8t, as per drawing: expansion valve 8t suitable for r 22 & 407 make denfoss or coopland emerson,refrigerent r 134, as per drawing: ref. gas r 134a without cylinder [ warranty period: 30 months after the date of delivery] sr. elec. engineer/plant punjab 124.00 kg , refrigerent r 407 c, as per drawing: without standard packing cylinder [ warranty period: 30 months after the date of delivery] sr. elec. engineer/plant punjab 124.00 kg , expansion valve 8t, as per drawing: expansion valve 8t suitable for r 22 & 407 make denfoss or coopland emerson [ warranty period: 30 months after the date of delivery] , expansion valve 3t, as per drawing: expansion valve 3t suitable for r 22 & 407 make danfoss or emerson coopland [ warranty period: 30 months after the date of delivery] , expansion valve 4t, as per drawing: expansion valve 4t suitable for r 22 & 407 make. danfoss or coopland emerson [ warranty period: 30 months after the date of delivery] , monochloro difloro methane or r 22 refrigerant gas, as per drawing: oper. point 40.8deg cent. [ warranty period: 30 months after the date of delivery] sr. elec. engineer/plant punjab 122.00 kg => limited...

Rail Coach Factory - Punjab

34946409 supply of expansion valve 8t, as per drawing: expansion valve 8t suitable for r 22 & 407 make denfoss or coopland emersonexpansion valve 8t, as per drawing: expansion valve 8t suitable for r 22 & 407 make denfoss or coopland emerson, refrigerent r 134, as per drawing: ref. gas r 134a without cylinder sr. elec. engineer / plant punjab 124.00 kg , refrigerent r 407 c, as per drawing: without standard packing cylinder sr. elec. engineer / plant punjab 124.00 kg , expansion valve 8t, as per drawing: expansion valve 8t suitable for r 22 & 407 make denfoss or coopland emerson , expansion valve 3t, as per drawing: expansion valve 3t suitable for r 22 & 407 make danfoss or emerson coopland , expansion valve 4t, as per drawing: expansion valve 4t suitable for r 22 & 407 make. danfoss or coopland emerson page 1 of 4 run date / time: 23 / 11 / 2022 12:30:37stores / hsq / rcf tender document , monochloro difloro methane or r 22 refrigerant gas, as per drawing: oper. point 40.8deg cent. sr. elec. engineer / plant punjab 122.00 kg => limited...

Rail Coach Factory - Punjab

34829993 supply of expansion valve 8t, as per drawing: expansion valve 8t suitable for r 22 & 407 make denfoss or coopland emersonexpansion valve 8t, as per drawing: expansion valve 8t suitable for r 22 & 407 make denfoss or coopland emerson, refrigerent r 134, as per drawing: ref. gas r 134a without cylinder sr. elec. engineer / plant punjab 124.00 kg , refrigerent r 407 c, as per drawing: without standard packing cylinder sr. elec. engineer / plant punjab 124.00 kg , expansion valve 8t, as per drawing: expansion valve 8t suitable for r 22 & 407 make denfoss or coopland emerson , expansion valve 3t, as per drawingap: expansion valve 3t suitable for r 22 & 407 make danfoss or emerson coopland , expansion valve 4t, as per drawing: expansion valve 4t suitable for r 22 & 407 make. danfoss or coopland emerson page 1 of 4 run date / time: 16 / 11 / 2022 11:02:38stores / hsq / rcf tender document , monochloro difloro methane or r 22 refrigerant gas, as per drawing: oper. point 40.8deg cent. sr. elec. engineer / plant punjab 122.00 kg => limited...

Water Supply And Sanitation Department - Punjab

34015732 tender for service of split ac 1.5 t.r service of split ac 2.5 t.r p/f fan motor of 000 of ac refrigerant gas refill for ac 1.0 tr refrigerant gas refill for ac 1.5 tr refrigerant gas refill for ac 2.0 tr p.c.b repair charges for 1 to 2 tr ac repair charges for 1 to 2tr p/f nitrile rubber insulation lox 16mm on copper pipe with steel grip tape service of window ac 1 to 2 t.r repair of stabilizer...

Military Engineer Services - Punjab

33740549 repair maintenance of summer and winter appliances at mh under ge ( east ) jalandhar cantt 1 supply and fixing in repairs geyser thermostat adjustable type suitable for geyser 25 / 35 / 50 ltr capacity complete all as specified and directed 2 material and labour for servicing of acs split type of capacity 1 / 1.5 / 2.0 tr inner & outer unit of any make, cleaning of outdoor condenser unit by taking down, cleaning of condenser coil and fins with chemical solutions c shine or equivalent and high pressure water jet pump, greasing to condenser fan, checking, tightening all electrical connections, and re fixing outdoor unit, cleaning of indoor unit, cleaning of cooling coils with chemical solution c shine or equivalent, washing of air filter, oiling and tightening of all nuts, bolts, replacement of condensed water flexible drain pipe etc complete all as specified and directed 3 material and labour for servicing of acs window type of capacity 1.5 / 2.0 tr of any make, by taking down ac, cleaning of condenser coil and fins with chemical solution c shine or equivalent and high pressure water jet pump, greasing to condenser fan, checking, tightening all electrical connections, cleaning of cooling coils with chemical solution c shine or equivalent, washing of air filter, oiling and tightening of all nut, bolts etc complete all as directed. 4 material and labour for replacement of compressor sealed unit of capacity 1.5 tr unit suitable for air conditioners window mounted type including taking out old unserviceable compressor, cleaning, flushing, vaccumizing the system, re charging of gas in adequate quantity, soldering, brazing of suction, discharge and charging line complete all as specified and directed.make: kirloskar / lg / toshiba / hitachi / gujral / carrier / tecumshah / usha shri ram / emerson compelad / whirlpool. 5 all as per srl item no. 4.00 here in before but suitable for air conditioners of capacity 2.0 tr 6 material and labour for replacement of compressor sealed unit suitable for air conditioner split type of capacity 1.0 / 1.5 tr in outdoor unit including taking out old unserviceable compressor, cleaning flushing, vaccumizing the system, recharging of gas in adequate quantity, soldering / brazing of suction, discharge and charging line complete all as specified and directed.make: kirloskar / lg / toshiba / hitachi / gujral / carrier / tecumshah / usha shri ram / emerson copeland. 7 all as per srl item no. 6.00 here in before but suitable for air conditioners of capacity 2.0 tr.note for item no. 4.00 to 7.00 : cost of wasted gas during charging shall be deemed to be included in the item rate. nothing shall be paid extra on this account. 8 supply, replacement, connecting and testingof double shaft blower motor with blades 240 volts single phase for window type ac 1.5 / 2.0 tr as per existing type and size complete all as directed.make: khaitan / universal / cg. / carrier / voltas / sidwal. 9 supply, replacement, connecting and testing of condenser blower motor with blades suitable for 1.5 / 2 tr split ac 240 volts single phase, as per existing type and size complete all as directed.make: khaitan / universal / cg. / carrier / voltas / sidwal. 10 supply, replacement, connecting and testing of indoor blower motor suitable for 1.5 / 2.0 tr split ac 240 volts single phase, as per existing type and size complete all as specified and directed.make: khaitan / universal / cg. / carrier / voltas / sidwal. 11 supply, replacement, connecting and testing of indoor blower suitable for 1.5 / 2.0 tr split ac 240 volts single phase, as per existing type and size complete all as specified and directed.make: khaitan / universal / cg. / carrier / voltas / sidwal. 12 supply and replacement of blower drum as per sample suitable for 1.5 / 2.0 tr window ac as per existing type and size complete all as directed.make: khaitan / universal / cg. / carrier / voltas 13 supply and fixing in replacement of temperature sensor as per existing type and size suitable for 1.0 / 1.5 / 2 tr window / split ac complete all as specified and directed.. 14 supply and fixing in replacement of starting / running capacitor conforming to is specification suitable for 1.0 / 1.5 / 2 tr window / split ac complete all as specified and directed..make: havells / unistar / asian / epcos / sarda / bajaj 15 material and labour / charging of refrigerant gas in window typeac 1.5 ton capacity including vaccumizing, leakage test and rectification of leakages etc complete all as specifiedand directed. 16 all as per item no 15.00 here in before but of capacity 2.0 tr 17 all as per item no 15.00 here in before but for split type ac of capacity 1.0 / 1.5 tr 18 all as per item no 15.00 here in before but for split type ac of capacity 2.0 tr 19 supply and fixing in replacement complete indoor unit of split type ac of capacity1.5 ton including cooling coils, pcb plate and display, remote control, cooling fan motor with blade, blower drum, complete with all accessories suitable for acs of make voltas / blue star / samsung / l.g complete including taking out old unit including cutting, brazing and testing all as specified and directed. 20 all as per item no 19.00 here in before but for capacity 2.0 ton. 21 supply and fixing in replacement geyser inner water tank s / s or copper suitable for geyser capacity 50 ltrs as per existing shape and type complete all as specified and directed. 22 supply and fixing in replacement geyser inner water tank s / s or copper suitable for geyser capacity 25 / 35 ltrs as per existing shape and type complete all as specified and directed. 23 repair / servicing of electronic pcb board for non inverter ac for any make / any type complete all as specified and directed 24 repair / servicing of electronic pcb board for inverter ac for any make / any type complete all as specified and directed 25 supply and fixing in replacement universal remote for any make / type of ac complete all as specified and directed 26 supply and fixing in replacement flare nut of size as per existing including necessary flaring of copper tubing complete all as specified and directed 27 supply and fixing in replacement service valve for any make of ac complete all as specified and directed 28 supply and fixing in replacement pcb remote plate dc operation suitable for hot and cold operation of ac window type 1.5 / 2 tr of any make complete with remoteall as specified and directed. 29 supply and fixing single pole & neutral sheet metal enclosure with 2 pin plug top and earth plug socket complete with mcb 20 a, all as specified and directed 30 supply and fixing in replacement of outer body of ac window type of standard size made of 1.6mm thick gi sheet, suitable for ac of capacity 1.5 / 2.0 tr of make lg / voltas / sidwal / carrier / blue star as per site requirement and as specified and directed. 31 supply and fixing in replacement of copper pipe for suction / discharge line suitable for ac split type of capacity 1.5 / 2.0 tr including cutting and soldering, brazing etc complete all as specified and directed 32 supply and fixing in replacement of heavy duty pipe insulation for copper piping with wrapping with packing brown tape suitable for ac split type of capacity 1.5 / 2 tr including cutting complete all as specified and directed 33 supply and fixing in replacement pvc drain pipe of standard size dia and length upto 1.5m complete all as specified and directed 34 supply and fixing in replacement window type ac of capacity 1.5 ton including cooling coils, condensor coil, compressor, pcb plate and display, remote control, cooling fan motor with blade, blower drum, complete with all accessories complete including taking out old unit including cutting, brazing and testing all asspecified and as directed. 35 supply and fixing in replacement front grill suitable for ac window mounted type of capacity 1.5 / 2.0 tr all as per existing type and size complete all asspecified and as directed. 36 supply and fixing in repair cooling / condensor coil set made out of copper pipe and fins suitable for ac window mounted type of capacity 1.5 / 2.0 tr all as per existing type and size including cutting soldering and testing complete all as specified. 37 all as per item no 36.00 here in before but for split ac 1.5 / 2.0 tr 38 supply and fixing in repairsgeyser heating element triangle / cup type 2.0 kw with gasket complete all as specified and directed 39 supply and fixing in repair capillary and filter suitable for ac window / split type of capacity 1.5 / 2 tr including cutting, soldering, brazing etc complete all as specified and directed. 40 supply and fixing in repair expansion valve suitable for ac window / split type of capacity 1.5 / 2.0 tr including cutting, soldering brazing etc complete all as specified and directed 41 supply and fixing in repair air filter suitable for window / split ac complete all as specified and directed 42 supply and fixing in repair reversible valve 4 way with plunger ac 200 / 240 volts 50 c / s as per existing make and type suitable for ac split / window type of capacity 1.5 / 2.0 tr including repair / modification to remote plate, cutting, soldering, brazing complete including charging if gas required to maintain the required pressure complete all as specified and directed.note: cost of all modification required including chargers in wiring connections and gas cycle system are deemed to be included in item rate nothing shall be paid extra. 43 material and labour for servicing of voltage stabilizer of capacity 4 / 5 kva by opening up and checking the fault, replacing necessary spares and make it functional complete all as specified and directed 44 all as per item no. 43.00 here in before but for of capacity 3 kva 45 supply and fixing in replacement of voltage stabilizer copper wounded for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 v to 290 v with output voltage stabilized at 230 v with accuracy of ± 2.5% and of capacity 16 amp complete all as specified and directed.makes: v guard / blue star / logicstat. 46 all as per item no. 45.00 here in before but for 12 amp 47 material and labour for pvc insulated and sheathed, flexible wire with multi stranded copper conductor wire of size 3 core, 1 sqmm, isi marked complete all as specified and directed. 48 material and labour for pvc insulated and sheathed, flexible wire with multi stranded copper conductor wire of size 3 core, 1.5 sqmm, isi marked complete all as specified and directed. 49 material and labour in replacement pvc insulated and sheathed, round flexible wire with multi stranded copper conductor wire of size 3 core, 2.5 sqmm, isi marked complete all as specified and directed 50 taking down old unserviceable sealed compressorand supply and fixing ofnewcompressor sealed unit suitable for water cooler 150 / 150 ltrs capacity including cleaning, vaccumizing, gas charging of adequate quantity and testing on load complete all as specified and directed.make: usha / sriram / emerson / kirloskar / carrier / tecumshah / whirlpool / emerson copeland. 51 all as per description of srl item no 50.00 here in before but sealed unit compressor suitable for water cooler capacity 60 / 120 ltrs 52 all as per description of srl item no 50.00 here in before but sealed unit compressor suitable for water cooler capacity 40 / 80 ltrs 53 material and labour for repair to body of water cooler / refrigerator / deep freezers of any capacity by fixing of ms sheet angle iron / ms flat etc all as per existing sizes including cutting, welding, riveting, drilling, bending to shape etc, at site including grinding, finishing and applying of one coat of primer complete all as specified and as directed.note : transportation of equipments / t&p required at site will be responsibility of the contractor, nothing shall be paid extra on this account. 54 supply and fixing in repair desert cooler stand made out of ms angle iron including cutting and welding, painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed 55 supply and replacement of water tap brass cp with inner / outer threads push type or with rotary knob of size 15 mm dia as per existing type and size complete all as specified and directed. 56 supply and replacement of water stop cock brass cp with inner / outer threads push type or with rotary knob of size 15 mm dia as per existing type and size complete all as specified and directed. 57 supply and fixing in replacement of thermostat switch suitable for water coolers complete all as specified and directed.make : danfoss / renutrol / indfoss or equivalent 58 supply and fixing in replacement of starting relay suitable for water coolers of capacity 150 / 120 / 80 ltrs complete all as specified and directed.make : danfoss / renutrol / indfoss or equivalent 59 supply and fixing in replacement of starting / running capacitor suitable for water coolers 150 / 120 / 80 ltrs complete all as specified and directed.make : usha / universal / havells / epcos / sarda or equivalent. 60 supply and fixing in replacement of overload protector suitable for water cooler of capacity 150 / 120 / 80 ltrs complete all as specified and directed.make : danfoss / renutrol / indfoss or equivalent. 61 supply and fixing in replacement fin type condenser with copper pipes suitable for water cooler of capacity 60 / 120 ltr as per existing type and size including cutting, soldering / brazing etc complete all as specified and directed. 62 all as per item no. 61.00 here in before but of capacity 40 / 80 ltrs. 63 all as per item no. 61.00 here in before but of capacity 150 / 150 ltrs. 64 taking down old and unserviceable sealed compressor and supply and fixing new sealedcompressor unit for refrigerator of capacity 25 to 360 ltrs includingcleaning, vaccumizing, gas charging of adequate qtyin the unit and soldering / brazing of suction and discharge and charging line complete all as specified and directed.make: kirloskar / lg / voltas / godrej / hitachi / toshiba / carrier / emerson compeland / whirpool. 65 all as per item no 64.00 above but for refg of capacity 160 to 240 ltr . 66 taking down old and unserviceable sealed compressor and supply and fixing new sealed compressor unit for deep freezer of capacity 405 ltrs including cleaning, vaccumizing, gas charging of adequate qtyin the unit and soldering / brazing of suction and discharge and charging line complete all as specified and directed.make: kirloskar / lg / voltas / godrej / hitachi / toshiba / carrier. 67 all as per item no. 66.00 but for deep freezer of capacity of 200 ltrs. 68 supply and fixing of evaporative coil ( cooling coil ) ofrefrigerators of capacity 260 / 310 / 360 ltrs as per existing type and size including cutting, taking out to old coil, brazing / soldering and testing complete all as specified and directed. 69 all as per item no 68.00 above but for refrigerator of capacity 165 / 175 / 185 / 180 / 215 ltr. 70 supply and fixing of condensor coil of refrigerators of capacity 250 to 360 ltrs as per existing type and size including cutting, taking out to old coil, brazing / soldering and testing complete all as specified and directed 71 all as per item no 70.00 above but for refrigerator of capacity 165 to 240 ltr. 72 supply and fixing magnetic door gasket suitable for refrigerator of capacity 165 to 360 ltrs as per existing type and size complete all as specified and directed. 73 supply and fixing thermostat switch suitable for refrigerator of capacity 165 to 360 ltrs as per existing size and type complete all as specified and directed.make : danfoss / renutol / indfoss or equivalent. 74 supply and fixing of starting relay with over load protector kit complete as per existing size and type complete all as specified and directed.make : danfoss / renutol / indfoss or equivalent. 75 material and labour in repair / servicing of pcb of double door fridge complete all as specified and directed 76 material and labour for charging refrigerant gas of existing type in refrigerator of capacity 165 to 360 ltrs including vaccumizing, leakage test and rectification of leakage etc complete all as specifiedand directed. 77 all as per item no. 76.00 but for deep freezer of capacity 200 to 405 ltrs. 78 supply and fixing in replacement cooling motor with fan, suitable to operative on ac, 220 / 240 volts, 50 c / s complete with frame square all as per existing size / type suitable for deep freezers and water coolers all as specified and directed 79 material and labour re painting of desert cooler internally and externally including removing of old paint and preparing surfaces for repainting and applying two coats of synthetic enamel paint by using spray gun and writing of mes / ge ( e ) jrc complete all as specified and directed. 80 supply and fixing in repair front air grill of desert cooler complete as per existing type and sizeall as specified and directed. 81 supply and fixing in replacement of desert cooler fan motor 1 / 8 hp, 1400 rpm, copper wound, three speed with suitable capacity capacitor suitable for desert cooler complete all as specified and directed.make: universal / khaitan / cg 82 supply and fixing in replacement ofsubmersible water pump of capacity 18 watt, single phase, 220 v for desert cooler with connecting wire complete all as specified and directed.make: universal / khaitan / cg 83 supply and replacement of desert cooler water spraying pvc pipes and junctions complete all as specified and directed 84 supply and fixing in replacement wood wool pad at site for desert cooler any size / capacity complete all as specified and directed. 85 supply and fixing in replacement starting capacitor 4.0 mfd heavy duty suitable for desert cooler complete all as specified and directed.make: usha / tibeon / keltron / asian / havells / epcos / bajaj 86 supply and fixing in repair switch piano flush type, 5 amps, 240 volt ac single pole, one way complete all as specified. 87 supply and fixing in repair switch piano flush type, 15 amps, 240 volt ac single pole, one way complete all as specified. 88 supply and fixing in replacement socket out let 5 amp, 5 pinflush type complete all as specified. 89 supply and fixing in replacement socket outlet multipurpose 2 in 1, 3 pin, 5 & 15 amps, flush type complete all as specified 90 supply and fixing in replacement top plug 6 amp complete all as specified and directed.make : anchor / havells / cona / ssk 91 all as per item no. 90.00 but 16 amp. 92 supply and fixing in replacement mcb sp 6 to 32 amps, 10 ka complete all as specified and directed. 93 supply and fixing in replacement for cpvc pipe for drain pipe of acs condensed water fixed complete to walls, ceilings or in floors etc. of size 40mm dia alongwith sockets, tees, bends, elbows, wall clamps, necessary joining material other accessories required for fixing of pipe with wall / floor complete all as specified and directed 94 material and labour for refixing of condensed water pipe line including necessary clamps, joint repairing with solutions and make it leak proof all as directed 95 supply and fixing in replacement for pvc pipe for drain pipe of acs condensed water fixed complete to walls, ceilings or in floors etc. of size 75mm dia, class 2 alongwith sockets, tees, bends, elbow, wall clamps, necessary joining material other accessories required for fixing of pipe with wall / floor all as specified and directed 96 supply and fixing in replacement for pvc pipe for drain pipe of acs condensed water fixed complete to walls, ceilings or in floors etc. of size 25mm dia, class 2 alongwith sockets, tees, bends, elbow, wall clamps, necessary joining material other accessories required for fixing of pipe with wall / floor all as specified and directed 97 taking down existing split ac 1.5 / 2.0 tr indoor unit and outdoor unit complete by disconnecting refrigerant suction and discharge lines, opening nuts and bolts taking out brackets of indoor and outdoor unit from walls, taking out voltage stabilizer form wall, taking indoor unit, outdoor unit and voltage stabilizer to another location without damaging the acs all as specified and directed 98 supply and fixing in replacement brackets for fixing split ac 1.5 / 2.0 tr indoor and outdoor unit with walls made of ms duly powder coated company made with 08 nos bolts, nuts and washers and 04 nos of fasteners complete all as specified and directed 99 supply and fixing in replacement floor stand for fixing split ac 1.5 / 2.0 tr out door unit made of ms duly powder coated factory made with bolts, nuts and washers and 04 nos fasteners complete all as specified and directed 100 material and labour for shifting of window type ac 1.5 / 2.0 tr by taking out ac from one room and shifting it to another room / department within military hospitals premises and fixing it at place where directed by department all as specified and directed 101 material and labour for making good of existing damaged wall of split ac pipe outlet area as per existing surface all as specified and directed 102 material and labour in repair sub main wiring with pvc insulated cable copper conductor frls two single core 4 sqmm drawn through pvc rigid non metallic conduit medium grade with all fittings including earth continuity frls copper conductor 4 sqmm pvc insulated with green insulation complete all as specified.note : two runs of single core 4 sqmm and one run of 4 sqmm pvc insulated stranded copper conductor through pvc rigid concealed conduit shall be measured as one rm. 103 material and labour in repair sub main wiring with pvc insulated cable copper conductor frls two single core 6 sqmm drawn through pvc rigid non metallic conduit medium grade with all fittings including earth continuity frls copper conductor 6 sqmm pvc insulated with green insulation complete all as specified.note : two runs of single core 6 sqmm and one run of 6 sqmm pvc insulated stranded copper conductor through pvc rigid concealed conduit shall be measured as one rm. 104 material and labour for cleaning / descaling of geyser of capacity 25 / 35 / 50 ltr of any make, with chemical solution, checking, tightening all electrical connections, tightening of all nut, bolts, etc complete all as specified and directed. 105 taking down geyser any capacity by disconnecting hot and cold water connection and refixing the geyser with new fasteners complete all as specified and directed 106 taking down geyser of capacity 25 ltrs by disconnecting hot and cold water connection and supply and fixing new 5 star rated geyser 25 ltr capacity with new fasteners of make venus / bajaj / havells / crompton / racold / ao smith all as specified and directed 107 material and labour for fabrication of tray made of gi sheet of size matching to split ac outdoor unit 1.5 / 2 ton complete with necessary provn of drain and fixing on the outdoor unit stand all as specified and directed 108 material and labour for refrigerant r 22 gas complete all as specified and directed 109 supply and fixing in replacement geyser assembly brassc p type 9 / 6 / 8 hole as per existing type and size complete all as specified and directed. 110 supply and fixing in replacement multifunction safety valve for geyser any capacity complete all as specified and directed 111 supply and fixing in replacement gasket for geyser any capacity complete all as specified and directed. 112 supply and fixing in replacement complete outdoor unit of split type ac of capacity1.5 ton including condensor coils copper with colling fins, condensor blower motor with blades, pcb plate with complete wiring, including compressor, charging of refrigerant gas, testing and commissioning of make voltas / blue star / samsung / lg complete including taking out old unit including cutting, brazing and testing all as specified and directed 113 all as per item no 112.00 here in before but for capacity 2.0 ton. 114 supply and fixing in repairs hot & cold flexible water connection with ss braided connection, 600mm long suitable for geysers complete all as specified and directed 115 supply and fixing in repairs hot & cold flexible water connection with ss braided connection, 450mm long suitable for geysers complete all as specified and directed 116 material and labour for servicing of wireless patient call bell 24 / 30 bed system and make it functional complete all as specified and directed 117 supply and fixing in repairs high voltage alkaline battery ( 12v ) 23a for call bell system complete all as specified and directed 118 supply and fixing wireless bed unit with socket with screws & mounting plate complete all as specified and directed 119 supply and fixing wired handset with l type jack complete all as specified and directed...

Military Engineer Services - Punjab

33740539 repair maintenance of summer and winter appliances except mh under ge ( east ) jalandhar cantt 1 supply and fixing in repairs geyser thermostat adjustable type suitable for geyser 25 / 35 / 50 ltr capacity complete all as specified and directed 2 material and labour for servicing of acs split type of capacity 1 / 1.5 / 2.0 tr inner & outer unit of any make, cleaning of outdoor condenser unit by taking down, cleaning of condenser coil and fins with chemical solutions c shine or equivalent and high pressure water jet pump, greasing to condenser fan, checking, tightening all electrical connections, and re fixing outdoor unit, cleaning of indoor unit, cleaning of cooling coils with chemical solution c shine or equivalent, washing of air filter, oiling and tightening of all nuts, bolts, replacement of condensed water flexible drain pipe etc complete all as specified and directed 3 material and labour for servicing of acs window type of capacity 1.5 / 2.0 tr of any make, by taking down ac, cleaning of condenser coil and fins with chemical solution c shine or equivalent and high pressure water jet pump, greasing to condenser fan, checking, tightening all electrical connections, cleaning of cooling coils with chemical solution c shine or equivalent, washing of air filter, oiling and tightening of all nut, bolts etc complete all as directed. 4 material and labour for replacement of compressor sealed unit of capacity 1.5 tr unit suitable for air conditioners window mounted type including taking out old unserviceable compressor, cleaning, flushing, vaccumizing the system, re charging of gas in adequate quantity, soldering, brazing of suction, discharge and charging line complete all as specified and directed.make: kirloskar / lg / toshiba / hitachi / gujral / carrier / tecumshah / usha shri ram / emerson compelad / whirlpool. 5 all as per srl item no. 4.00 here in before but suitable for air conditioners of capacity 2.0 tr 6 supply, replacement, connecting and testingof double shaft blower motor with blades 240 volts single phase for window type ac 1.5 / 2.0 tr as per existing type and size complete all as directed.make: khaitan / universal / cg. / carrier / voltas / sidwal. 7 supply, replacement, connecting and testing of condenser blower motor with blades suitable for 1.5 / 2 tr split ac 240 volts single phase, as per existing type and size complete all as directed.make: khaitan / universal / cg. / carrier / voltas / sidwal. 8 supply, replacement, connecting and testing of indoor blower motor suitable for 1.5 / 2.0 tr split ac 240 volts single phase, as per existing type and size complete all as specified and directed.make: khaitan / universal / cg. / carrier / voltas / sidwal. 9 supply, replacement, connecting and testing of indoor blower suitable for 1.5 / 2.0 tr split ac 240 volts single phase, as per existing type and size complete all as specified and directed.make: khaitan / universal / cg. / carrier / voltas / sidwal. 10 supply and replacement of blower drum as per sample suitable for 1.5 / 2.0 tr window ac as per existing type and size complete all as directed.make: khaitan / universal / cg. / carrier / voltas 11 supply and fixing in replacement of temperature sensor as per existing type and size suitable for 1.0 / 1.5 / 2 tr window / split ac complete all as specified and directed.. 12 supply and fixing in replacement of starting / running capacitor conforming to is specification suitable for 1.0 / 1.5 / 2 tr window / split ac complete all as specified and directed..make: havells / unistar / asian / epcos / sarda / bajaj 13 material and labour / charging of refrigerant gas in window typeac 1.5 ton capacity including vaccumizing, leakage test and rectification of leakages etc complete all as specifiedand directed. 14 all as per item no 13.00 here in before but of capacity 2.0 tr 15 all as per item no 13.00 here in before but for split type ac of capacity 1.0 / 1.5 tr 16 all as per item no 13.00 here in before but for split type ac of capacity 2.0 tr 17 supply and fixing in replacement complete indoor unit of split type ac of capacity1.5 ton including cooling coils, pcb plate and display, remote control, cooling fan motor with blade, blower drum, complete with all accessories suitable for acs of make voltas / blue star / samsung / l.g complete including taking out old unit including cutting, brazing and testing all as specified and directed. 18 all as per item no 17.00 here in before but for capacity 2.0 ton. 19 material and labour for refixing of condensed water pipe line including necessary clamps, joint repairing with solutions and make it leak proof all as directed 20 supply and fixing in replacement mcb sp 6 to 32 amps, 10 ka complete all as specified and directed. 21 repair / servicing of electronic pcb board for non inverter ac for any make / any type complete all as specified and directed 22 repair / servicing of electronic pcb board for inverter ac for any make / any type complete all as specified and directed 23 supply and fixing in replacement universal remote for any make / type of ac complete all as specified and directed 24 supply and fixing in replacement flare nut of size as per existing including necessary flaring of copper tubing complete all as specified and directed 25 supply and fixing in replacement service valve for any make of ac complete all as specified and directed 26 supply and fixing in replacement pcb remote plate dc operation suitable for hot and cold operation of ac window type 1.5 / 2 tr of any make complete with remoteall as specified and directed. 27 supply and fixing single pole & neutral sheet metal enclosure with 2 pin plug top and earth plug socket complete with mcb 20 a, all as specified and directed 28 supply and fixing in replacement of outer body of ac window type of standard size made of 1.6mm thick gi sheet, suitable for ac of capacity 1.5 / 2.0 tr of make lg / voltas / sidwal / carrier / blue star as per site requirement and as specified and directed. 29 supply and fixing in replacement of copper pipe for suction / discharge line suitable for ac split type of capacity 1.5 / 2.0 tr including cutting and soldering, brazing etc complete all as specified and directed 30 supply and fixing in replacement of heavy duty pipe insulation for copper piping with wrapping with packing brown tape suitable for ac split type of capacity 1.5 / 2 tr including cutting complete all as specified and directed 31 supply and fixing in replacement pvc drain pipe of standard size dia and length upto 1.5m complete all as specified and directed 32 supply and fixing in replacement front grill suitable for ac window mounted type of capacity 1.5 / 2.0 tr all as per existing type and size complete all asspecified and as directed. 33 supply and fixing in replacement window type ac of capacity 1.5 ton including cooling coils, condensor coil, compressor, pcb plate and display, remote control, cooling fan motor with blade, blower drum, complete with all accessories complete including taking out old unit including cutting, brazing and testing all asspecified and as directed. 34 supply and fixing in repair cooling coil set made out of copper pipe and fins suitable for ac window mounted type of capacity 1.5 / 2.0 tr all as per existing type and size including cutting soldering and testing complete all as specified. 35 all as per item no 34.00 here in before but for split ac 1.5 / 2.0 tr 36 supply and fixing in repair capillary and filter suitable for ac window / split type of capacity 1.5 / 2 tr including cutting, soldering, brazing etc complete all as specified and directed. 37 supply and fixing in repair expansion valve suitable for ac window / split type of capacity 1.5 / 2.0 tr including cutting, soldering brazing etc complete all as specified and directed 38 supply and fixing in repair air filter suitable for window / split ac complete all as specified and directed 39 supply and fixing in repair reversible valve 4 way with plunger ac 200 / 240 volts 50 c / s as per existing make and type suitable for ac split / window type of capacity 1.5 / 2.0 tr including repair / modification to remote plate, cutting, soldering, brazing complete including charging if gas required to maintain the required pressure complete all as specified and directed.note: cost of all modification required including chargers in wiring connections and gas cycle system are deemed to be included in item rate nothing shall be paid extra. 40 material and labour for servicing of voltage stabilizer of capacity 4 / 5 kva by opening up and checking the fault, replacing necessary spares and make it functional complete all as specified and directed 41 all as per item no. 40.00 here in before but for of capacity 1 3 kva 42 supply and fixing in replacement of voltage stabilizer copper wounded for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 v to 290 v with output voltage stabilized at 230 v with accuracy of ± 2.5% and of capacity 16 amp complete all as specified and directed.makes: v guard / blue star / logicstat. 43 all as per item no. 42.00 here in before but for 12 amp 44 material and labour pvc insulated and sheathed, flexible wire with multi stranded copper conductor wire of size 3 core, 70 / 0.0076, isi marked complete all as specified and directed. 45 material and labour in replacement pvc insulated and sheathed, round flexible wire with multi stranded copper conductor wire of size 3 core, 2.5 sqmm, isi marked complete all as specified and directed 46 material and labour in replacement pvc insulated and sheathed, round flexible wire with multi stranded copper conductor wire of size 3 core, 4 sqmm, isi marked complete all as specified and directed 47 taking down old unserviceable sealed compressorand supply and fixing ofnewcompressor sealed unit suitable for water cooler 150 / 150 ltrs capacity including cleaning, vaccumizing, gas charging of adequate quantity and testing on load complete all as specified and directed.make: usha / sriram / emerson / kirloskar / carrier / tecumshah / whirlpool / emerson copeland. 48 all as per srl item no 47.00 here in before but sealed unit compressor suitable for water cooler capacity 60 / 120 ltrs 49 all as per srl item no 47.00 here in before but sealed unit compressor suitable for water cooler capacity 40 / 80 ltrs 50 material & labour for charging of refrigerant gas in water cooler of capacity 40 to 150 ltr including cleaning, vaccumizing, gas charging of adequate quantity and testing on load complete all as specified and directed. 51 material and labour for repair to body of water cooler / refrigerator / deep freezers of any capacity by fixing of ms sheet angle iron / ms flat etc all as per existing sizes including cutting, welding, riveting, drilling, bending to shape etc, at site including grinding, finishing and applying of one coat of primer complete all as specified and as directed.note : transportation of equipments / t&p required at site will be responsibility of the contractor, nothing shall be paid extra on this account. 52 supply and fixing in repair desert cooler stand made out of ms angle iron including cutting and welding, painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed 53 supply and replacement of water tap brass cp with inner / outer threads push type or with rotary knob of size 15 mm dia as per existing type and size complete all as specified and directed. 54 supply and fixing in replacement of thermostat switch suitable for water coolers complete all as specified and directed.make : danfoss / renutrol / indfoss or equivalent 55 supply and fixing in replacement of starting relay suitable for water coolers of capacity 150 / 120 / 80 ltrs complete all as specified and directed.make : danfoss / renutrol / indfoss or equivalent 56 supply and fixing in replacement of starting / running capacitor suitable for water coolers 150 / 120 / 80 ltrs complete all as specified and directed.make : usha / universal / havells / epcos / sarda or equivalent. 57 supply and fixing in replacement of overload protector suitable for water cooler of capacity 150 / 120 / 80 ltrs complete all as specified and directed.make : danfoss / renutrol / indfoss or equivalent. 58 supply and fixing in replacement fin type condenser with copper pipes suitable for water cooler of capacity 60 / 120 ltr as per existing type and size including cutting, soldering / brazing etc complete all as specified and directed. 59 all as per item no. 58.00 here in before but of capacity 40 / 80 ltrs. 60 all as per item no. 58.00 here in before but of capacity 150 / 150 ltrs. 61 taking down old and unserviceable sealed compressor and supply and fixing new sealedcompressor unit for refrigerator of capacity 260 360 ltrs includingcleaning, vaccumizing, gas charging of adequate qtyin the unit and soldering / brazing of suction and discharge and charging line complete all as specified and directed.make: kirloskar / lg / voltas / godrej / hitachi / toshiba / carrier / emerson compeland / whirpool. 62 all as per item no 61.00 above but for refg of capacity 165 240 ltr . 63 taking down old and unserviceable sealed compressor and supply and fixing new sealed compressor unit for deep freezer of capacity 400 500 ltrs including cleaning, vaccumizing, gas charging of adequate qtyin the unit and soldering / brazing of suction and discharge and charging line complete all as specified and directed.make: kirloskar / lg / voltas / godrej / hitachi / toshiba / carrier. 64 all as per item no. 63.00 but for deep freezer of capacity of 200 320 ltrs. 65 supply and fixing of evaporative coil ( cooling coil ) ofrefrigerators of capacity 260 360 ltrs as per existing type and size including cutting, taking out to old coil, brazing / soldering and testing complete all as specified and directed. 66 all as per item no 65.00 above but for refrigerator of capacity 165 230 ltr. 67 supply and fixing magnetic door gasket suitable for refrigerator of capacity 165 to 360 ltrs as per existing type and size complete all as specified and directed. 68 supply and fixing thermostat switch suitable for refrigerator of capacity 165 to 360 ltrs as per existing size and type complete all as specified and directed.make : danfoss / renutol / indfoss or equivalent. 69 supply and fixing of starting relay with over load protector kit complete as per existing size and type complete all as specified and directed.make : danfoss / renutol / indfoss or equivalent. 70 material and labour in repair / servicing of pcb of double door fridge complete all as specified and directed 71 material and labour for charging refrigerant gas of existing type in refrigerator of capacity 165 to 360 ltrs including vaccumizing, leakage test and rectification of leakage etc complete all as specifiedand directed. 72 all as per item no. 71.00 but for deep freezer of capacity 200 to 500 ltrs. 73 supply and fixing in replacement cooling motor with fan, suitable to operative on ac, 220 / 240 volts, 50 c / s complete with frame square all as per existing size / type suitable for deep freezers and water coolers all as specified and directed 74 material and labour for de scaling of collector unit andpiping complete and testing of solar water heaters of capacity 100 lpd complete all as specified and directed. 75 all as per item no. 74.00 but of capacity 400 / 500 lpd 76 all as per item no. 74.00 but of capacity 1000 lpd 77 supply and fixing in repair ofsolar water heating element 2 kw single phase, 230 volts, isi marked as per existing type and size complete all as specified and directed. 78 all as per item no. 77.00 but element 3 kw 79 supply and fixing thermostat switch suitable forsolar water heaterof capacity 100 to 1000 lpd all as per specified isi marked as per existing type and sizecomplete all as specified and directed. 80 supply and fixing in repairheat collector glass of any size suitable for solar water heaters of capacity 100 to 1000 lpd as per existing type and thickness complete all as specified and directed 81 material and labour for replacement of copper pipe with insulation of size 20mm dia in collector of solar water heaters of capacity 300 lpd including cutting, soldering and testing complete all as specified and directed. 82 material and labour for painting of solar water heater ms structure by removing of old paint and preparing surfaces for repainting and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed 83 supply and fixing glass wool insulation 25mm thick duly wrapped with jute cloth complete for 15mm / 20mm / 25mm bore pipe complete all as specified and directed 84 material and labour for aluminium cladding for covering glass insulation complete all as specified and directed 85 material and labour for condensing coil fan motor suitable for deep freezer 200 ltr to 500 ltr capacity complete all as specified and directed 86 material and labour for galvanised steel tubes 15mm bore, medium grade with & including all fittings fixed to wall, ceilings and or laid in floors etc. complete all as specified and directed. 87 all as per item no. 86.00 but 20mm bore 88 all as per item no. 86.00 but 25mm bore 89 supply and fixing 20mm gun metal globe or gate valve, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified 90 all as per item no. 89.00 but 25mm bore 91 supply and fixing rotational moulded polye thylene water storage tanks, 500 litres capacity ( cylindrical vertical with closed top ) , isi marked, hoisted and fixed in position all as specified in ssr part i, including dismantling of existing water tank complete all as specified and directed. 92 supply and fixing rotational moulded polye thylene water storage tanks, 1000 litres capacity ( cylindrical vertical with closed top ) , isi marked, hoisted and fixed in position all as specified in ssr part i, including dismantling of existing water tank complete all as specified and directed. 93 material and labour re painting of desert cooler internally and externally including removing of old paint and preparing surfaces for repainting and applying two coats of synthetic enamel paint by using spray gun and writing of mes / ge ( e ) jrc complete all as specified and directed. 94 supply and fixing in repair front air grill of desert cooler complete as per existing type and sizeall as specified and directed. 95 supply and fixing in replacement of desert cooler fan motor 1 / 8 hp, copper wound, three speed with suitable capacity capacitor suitable for desert cooler complete all as specified and directed.make: universal / khaitan / cg 96 supply and fixing in replacement ofsubmersible water pump of capacity 18 watt, single phase, 220 v for desert cooler with connecting wire complete all as specified and directed.make: universal / khaitan / cg 97 supply and fixing in replacement ofdesert cooler pvc pipe 1m min from water pump to pvc distributor including pvc distributor and 03 nos pvc bend complete all as specified and directed. 98 supply and fixing in replacement wood wool pad at site for desert cooler any size / capacity complete all as specified and directed. 99 supply and fixing in replacement starting capacitor 4.0 mfd heavy duty suitable for desert cooler complete all as specified and directed.make: usha / tibeon / keltron / asian / havells / epcos / bajaj 100 material and labour in replacement of outer body of room cooler as per existing type and size of standard size made of 1.6mm thick gi sheet, suitable for room cooler of capacity 5000 cum / hr duly painted complete internally and externally with two coats of super enamelled paint over a coat of red oxide primer all as specified and directed. 101 supply and fixing in repair switch piano flush type, 5 amps, 240 volt ac single pole, one way complete all as specified. 102 supply and fixing in repair switch piano flush type, 15 amps, 240 volt ac single pole, one way complete all as specified. 103 supply and fixing in replacement socket out let 5 amp, 5 pinflush type complete all as specified. 104 supply and fixing in replacement socket outlet multipurpose 2 in 1, 3 pin, 5 & 15 amps, flush type complete all as specified 105 supply and fixing in replacement top plug 6 amp complete all as specified and directed.make : anchor / havells / cona / ssk 106 all as per item no. 105.00 but 16 amp. 107 supply and fixing in replacement complete outdoor unit of split type ac of capacity1.5 ton including condensor coils copper with colling fins, condensor blower motor with blades, pcb plate with complete wiring, including compressor, charging of refrigerant gas, testing and commissioning of make voltas / blue star / samsung / lg complete including taking out old unit including cutting, brazing and testing all as specified and directed 108 all as per item no 107.00 here in before but for capacity 2.0 ton. 109 supply and fixing in replacement for cpvc pipe for drain pipe of acs condensed water fixed complete to walls, ceilings or in floors etc. of size 40mm dia alongwith sockets, tees, bends, elbows, wall clamps, necessary joining material other accessories required for fixing of pipe with wall / floor complete all as specified and directed 110 all as per item no. 109.00 here in before but of size 25mm dia. 111 taking down existing split ac 1.5 / 2.0 tr indoor unit and outdoor unit complete by disconnecting refrigerant suction and discharge lines, opening nuts and bolts taking out brackets of indoor and outdoor unit from walls, taking out voltage stabilizer form wall, taking indoor unit, outdoor unit and voltage stabilizer to another location without damaging the acs all as specified and directed 112 supply and fixing in replacement brackets for fixing split ac 1.5 / 2.0 tr indoor and outdoor unit with walls made of ms duly powder coated company made with 08 nos bolts, nuts and washers and 04 nos of fasteners complete all as specified and directed 113 supply and fixing in replacement floor stand for fixing split ac 1.5 / 2.0 tr out door unit made of ms duly powder coated factory made with bolts, nuts and washers and 04 nos fasteners complete all as specified and directed 114 material and labour for shifting of window type ac 1.5 / 2.0 tr by taking out ac from one room and shifting it to another location within 500 mtr and fixing it at place where directed by department all as specified and directed 115 material and labour in repair sub main wiring with pvc insulated cable copper conductor frls two single core 4 sqmm drawn through pvc rigid non metallic conduit medium grade with all fittings including earth continuity frls copper conductor 4 sqmm pvc insulated with green insulation complete all as specified.note : two runs of single core 4 sqmm and one run of 4 sqmm pvc insulated stranded copper conductor through pvc rigid concealed conduit shall be measured as one rm. 116 material and labour in repair sub main wiring with pvc insulated cable copper conductor frls two single core 6 sqmm drawn through pvc rigid non metallic conduit medium grade with all fittings including earth continuity frls copper conductor 6 sqmm pvc insulated with green insulation complete all as specified.note : two runs of single core 6 sqmm and one run of 6 sqmm pvc insulated stranded copper conductor through pvc rigid concealed conduit shall be measured as one rm. 117 supply, laying, testing and commissioning in replacement of service wire pvc insulated, electric cables, ( heavy duty ) 1100 volts grade with aluminium conductor of size 4 sqmm 2 core complete all as specified and directed 118 supply, laying, testing and commissioning in replacement of service wire pvc insulated, electric cables, ( heavy duty ) 1100 volts grade with aluminium conductor of size 6 sqmm 2 core complete all as specified and directed 119 material and labour for cleaning / descaling of geyser of capacity 25 / 35 / 50 ltr of any make, with chemical solution, checking, tightening all electrical connections, tightening of all nut, bolts, etc complete all as specified and directed. 120 supply and fixing in repairs of metal clad industrial plug 20 amps, 250 v, 2 pole with earth suitable for geyser / ac complete all as specified & directed. 121 supply and fixing in repairs of metal clad industrial socket 20 amps, 2 pole with earth suitable for geyser / ac complete all as specified & directed. 122 taking down geyser any capacity by disconnecting hot and cold water connection and refixing the geyser with new fasteners complete all as specified and directed 123 supply and fixing in replacement geyser inner water tank s / s or copper suitable for geyser capacity 50 ltrs as per existing shape and type complete all as specified and directed. 124 supply and fixing in replacement geyser inner water tank s / s or copper suitable for geyser capacity 25 / 35 ltrs as per existing shape and type complete all as specified and directed. 125 supply and fixing in replacement geyser assembly brassc p type 9 / 6 / 8 hole as per existing type and size complete all as specified and directed. 126 supply and fixing in replacement multifunction safety valve for geyser any capacity complete all as specified and directed 127 supply and fixing in repairsgeyser heating element triangle / cup type 1.5 kw with gasket complete all as specified and directed 128 supply and fixing in repairsgeyser heating element triangle / cup type 2.0 kw with gasket complete for make venus geyser models all as specified and directed 129 supply and fixing in repairs hot & cold flexible water connection with steel braided outer tube, 600mm long suitable for geysers complete all as specified and directed 130 supply and fixing in repairs hot & cold flexible water connection with steel braided outer tube, 450mm long suitable for geysers complete all as specified and directed 131 supply and fixing in repairs cp bib cock 15mm dia complete all as specified and directed 132 supply and fixing in repairs cp stop cock 15mm dia complete all as specified and directed...

Northern Railway - Punjab

33055322 supply of gas refrigerantgas refrigerant,gas refrigerant freon 22, monochloro difluoro methane (chclf2) colourless, oudorless ,non toxic, non flammable gas generally conforming to is:5610/1993(2nd ,rev.) similar to type of floron 22 ,mafron 22 or similar. cylinder should be of 61 kg. sr. section punjab 183.00 kg...

Indian Railway - Punjab

33027946 supply of supply of refrigeration gas r 410a and empty cylindersupply of refrigeration gas r 410a and empty cylinder, supply of refrigerant gas r 410 a ( in sealed cylinder of 45 kg. ) refrigerant make stallion / freon / mefron / fluron / kiro / flouro , empty gas cylinder => limited...

Punjab State Transmission Corporation Limited - Punjab

32783063 tender for repair of air conditioning plant at 220 kv s/s gndtp bathinda under p&m division pstcl bathinda: 1) supply of 62 kg refrigerant gas r 22 2) supply of 2 no. nitrogen gas cylinders of 120 psi pressure 3) labour charges for identification of gas leakage & mechanical faults, rectification of these faults, repair, service, gas filling, commissioning and thereafter supervision for 6 months....

Punjab State Power Corporation Limited - Punjab

32713959 tender for procurement of refrigerant gas m 22 for air conditioning system at ggss tp,roopnagar refrigerant gas m 22 (mafron make ) filled in 61 kg factory sealed cylinders (returnable ) conf to is 56 10c:1983...

Punjab State Power Corporation Limited - Punjab

31520942 procurement of spares for ac plant refrigeration and hydrogen driers at ggsstp rupnagar procurement of spares for ac plant refrigeration and hydrogen driers at ggsstp rupnagar , scroll compressor zr72 380 415v,3 phase, 50 hz, 5.5tr, emerson copeland/lg make , scroll compressor zr144 for11tr lg make ductable split ac, 380 415v, 3 phase, 50hz, make: lg/copeland/ danfoss , dryerssize ½* ½flare 6 long catch all/dry all make danfoss , rotary compressorfor 1.5 ton lg make window ac, 1 phase, 50hz, 220 240v,r 22 gas make: lg/highly/hitachi/ carrier , remote kit including thermostat and pcb for 1.5tr lg make window air conditioner , rotary compressorfor lg make 2tr window ac, r22, 1ph 50hz 220 240 vac, make: lg/ highly/ hitachi/ carrier , running capacitor 10 mfd (tecumesh keltron/epcos) , compressor model: kce 461 hae for 80/120 ltr. water coolers emerson copeland make , compressor model: kce 443 hae for 60/80 ltr. water coolers emerson copleand make , startingcapacitor 6mfd (tecumesh keltron/epcos) , digital thermostat range 10oc to 50oc of make sub zero/danfoss , heavy duty copper tube1/4 , heavy duty copper tube3/8 , reciprocating compressor 2.5 tr 3 phase 380 415 v 50 hz make emerson copeland , fan motor for lg make window ac 1.5 ton, 29kge775t, 220volt, a 1.25 rpm 880 hz 50, ph i volt 149, capacity 10.0/370 volt,cpn h102 00311g , air heater strip rating 2 kw, 230 v ac,29 inch length for package air conditioners , thermostate for water cooler indfoss/ ranuool make , double cappilary filter , dual run capacitor 50x6 mfd epcos , dual run capacitor 50x4 mfd epcos , pcb remote kit including thermo state for voltas window ac 1.5 tr , epcos make dual run capacitor 50+10 mfd +5%, 440 vac, 50/60 hz for lg make 1.5 tr window ac , float valve (brass) completefor water cooler (15mm) , fan motor for voltas make 1.5 ton window ac, 230 v, 50 hz, 1 ph, 1/7 hp, rpm 915/890/865, cap.6.0/440v, model 29sahg058, marathon/ ge , thermally protected scroll compressor unit of capacity 7.5 tr voltage 415, 3 phase voltas/kirloskar/copeland make. , chiller temp, indicator controller , rumptom brazing rod , angle valve 1/4 x ¼” brass , thermostatic expension valve for 5 tr , r 22 gas flare connection type , fan motor along with base and blade brg. type, self lubricated. 1/34hp, 230v,1 phase, 50 hz, 940 rpm ge/marathon make for water cooler , state thimble for window ac size 4 mm heavy duty copper (1 pkt = 100nos.) , single phasing preventor for compressor twin of 5.5 tr lg make ductable split ac model lbuh0750qc , rotary compressor for split ac 1.5 t lg make model 5cw2af5 make lg/highly/ hitachi/ carrier , out door fan motor for split ac 1.5 t lg make , capillary tube 0.64 , hp switch for lg ductable ac 7.5 tr, model 6600l0002a , lp switch for lg ductable ac 7.5 tr, model 6600l0001a , push type cock 15mm water cool , sealed compressor 1.5tr3 415v kch 522 hae for hydrogen drier , refrigerant gas drier 3/8 l5 dn 50 , vaneleaning liq.for a.c. plant cooling coils , starting capacitor 80/100 mfd , copper elbow size 1/2 , copper elbow 5/8 , copper elbow size 7/8 , copper elbow size 1 1/8 , over load protector for kce 461 , over load protector for kce 443 , dryers size 5/8 x 5/8, 6 long catch all/dry all , flair nut brass pin valve , supply lead 3 core with earth wire size 70/76 mm , wall thermometer for measuring temp 10 50/100 degrees. mounting ms case with stove enamelled paint with marking on glass stem , freon bourdon tube pressure gauge 0 300 kg/cm2 dial size 100mm, process connection = bottom entry case material ss 316 , condenser coil for lg make window ac 1.5 tr (copper) , starting capacitor 4mfd , door gasket for water cooler loose , angular thimble brass for window ac 4 mm , air filter model 5230a30001c for lg 7.5 tr ductable ac , pressure gauge 0 300 lbs for hydrogen drier jay pee make capcity 40 m3/hr , compound gauge 30 to 0 to 150 lbs for hydrogen drier jay pee make capcity 40 m3/hr , indoor blower motormodel no. 4681a30016afor lg 7.5 tr ductable ac , expansion v/v 7.5 tr package ac r 22. , accumulator model no. 9901 01 06 , copper pipe ½” , copper elbow size 1 1/2 , copper pipe 1 1/2 , water cooloer body 80/100 including 2 taps , lg condenser window ac 2.0tr , lg condenser split ac 2.0tr...

Dr Br Ambedkar National Institute Of Technology - Punjab

30806487 cassette ac with variable refrigerant flow cassette ac with variable refrigerant flow , purchaseof cassette ac ( inverter ) ( strictly as per specifications of tender documents ( the items should be supplied alongwith all the necessary / essential accessories as per tender documents ) , charges for purchaseof cassette ac ( inverter ) providing and fixing ofair cooled cassette air conditioners each comprising an outdoor unit consisting ofinverter compressor, air cooledcondensing unit, condenser fan etc.with outer casing and indoor fan coil unit ( s ) consisting of centrifugal fans, fan motor, dx coolingcoil, outer casing, filter, control and power panel with ( cordless ) remote control etc. full charge of refrigerant gas and oil etc complete in all respect. indoor and outdoor units shall be inter connected with insulated copper refrigerant pipe and drain pipe of required length as given, cabling and wiring, control and power cabling ( priced separately ) . m.s. base frame, supports etc. complete as per specifications and drawings. the cost shall also include angle iron stands for outdoor units. ( 2.0 t r unit ) , refrigerantpipingfor units supply and installationof interconnectingrefrigerant pipingof various sizes as required for the full functionality of the completein all respects duly insulated with closedcell nitrile rubberas per specifications of the mancufacture 15.9 mm o.d. ( insulation :13 mm ) , 9.5 mmo.d. ( insulation :13mm ) , supplying, installation, testing and commissioning of followingsizes ofrigid pvc pipingcomplete with elbow t joint, socketduly supportedas per specificationsand insulatedwith 6mm thick closedcell nitrilerubberinsultation 25mm dia , electrical cables providing& fixingcontrolcum transmissionwiring of 4 corex 1.5 sqmm copperinsuitableconduitsbetweenindoor and outdoorunit 70 rmt , electrical cables providing & fixingof electrical supplyflexiblecablingof3 corex 2.5sq .mm copperin suitableconduits between idu & room db 50 rmt...

Indian Army - Punjab

30395695 bids are invited for split type air conditioner(hot& cold) 2ton, inverter technology with 3 star ratingsingle phase 240 volts.drain pipe of suitable size brought to ground level from any height including making cable connection by providing 3 core 2.5 sqmm copper conductor cable pvc insulated.make: daikin/ blue star/ voltas/ samsung/ lg. , installation and testing of split air conditioner. indoor mounting plate and drain pipe of suitable size brought to ground level from any height including making cable connection by providing 3 core 2.5 sqmmm copper conducter cable pvc insulated, sheathed of adequate length as required at sight and initial filling of refrigerant gas including making round hole on any type of wall for taking up refrigerant tubing, drain pipe & cable etc and making good the disturbed surface by matching with existing adjoining surfaces complete all as specifies and directed. total quantity : 1...

Indian Army - Punjab

30117177 bids are invited for refrigerant gas (q3) () total quantity : 61...

Dr Br Ambedkar National Institute Of Technology - Punjab

29740074 cassette ac with variable refrigerant flow cassette ac with variable refrigerant flow , purchaseof cassette ac ( inverter ) ( strictly as per specifications of tender documents ( the items should be supplied alongwith all the necessary / essential accessories as per tender documents ) , charges for purchaseof cassette ac ( inverter ) providing and fixing ofair cooled cassette air conditioners each comprising an outdoor unit consisting ofinverter compressor, air cooledcondensing unit, condenser fan etc.with outer casing and indoor fan coil unit ( s ) consisting of centrifugal fans, fan motor, dx coolingcoil, outer casing, filter, control and power panel with ( cordless ) remote control etc. full charge of refrigerant gas and oil etc complete in all respect. indoor and outdoor units shall be inter connected with insulated copper refrigerant pipe and drain pipe of required length as given, cabling and wiring, control and power cabling ( priced separately ) . m.s. base frame, supports etc. complete as per specifications and drawings. the cost shall also include angle iron stands for outdoor units. ( 2.0 t r unit ) , refrigerantpipingfor units supply and installationof interconnectingrefrigerant pipingof various sizes as required for the full functionality of the completein all respects duly insulated with closedcell nitrile rubberas per specifications of the mancufacture 15.9 mm o.d. ( insulation :13 mm ) , 9.5 mmo.d. ( insulation :13mm ) , supplying, installation, testing and commissioning of followingsizes ofrigid pvc pipingcomplete with elbow t joint, socketduly supportedas per specificationsand insulatedwith 6mm thick closedcell nitrilerubberinsultation 25mm dia , electrical cables providing& fixingcontrolcum transmissionwiring of 4 corex 1.5 sqmm copperinsuitableconduitsbetweenindoor and outdoorunit 70 rmt , electrical cables providing & fixingof electrical supplyflexiblecablingof3 corex 2.5sq .mm copperin suitableconduits between idu & room db 50 rmt...

Bharat Sanchar Nigam Limited - Punjab

27788938 operation and comprehensive maintenance of ems for te bldg at rayya jandiala guru majitha ajnala and comprehensive maintenance of ems for various rented buildings and group exchanges under sdca goindwal rayya jandiala guru majitha ajnala sh clear , wet servicing of existing 1 . 5tr/2tr window/split ac unit i/c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i/c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split/wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing/flaring the leak points , vacumising , purging and making the system leak proof i/c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5/2 . 0 tr , replacement of following capacity of existing old defective compressor with new sealed compressor i/c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition/alteration i/c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i/c testing etc as reqd . ( m/s emerson/tecumseh/ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new/oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac/sac units i/c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( 80/100 mfd ) ( m/s epcos/asian/ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( m/s epcos/asian/ss make ) , repairing of control card pcb existing 1 . 5/2 . 0tr split ac units , condenser fan blade ( pvc/frp ) , condensor coil , replacement of control card pcb suitable for 1 . 5tr split ac units , blower fan motor for idu of split ac unit ( m/s aue/marathon ge/national/ diamond /ss make ) , thermostat ( m/s danfoss/indfoss/arvind/ss make , washable nylon air filter , replacement/rewinding of existing condenser motor of 1 . 5/2 tr split/window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , sitc of photo electric type smoke detector complete with detector base etc as reqd and as per bsnl specifications , sitc of electro pneumatic type dual action ( heat cum rate of rise in temperature ) heat detector complete with detector base etc as reqd and as per bsnl specifications . , providing repairs to the existing microprocessor based fire detection and fire alarm panel i/c replacement of transformer , control cards , pcb i/c making minor repairs to make the panel fully functional as per the directions of the engineer in charge . , replacement of following ampere hour capacity sealed maintenance free battery i/c making connections , testing and commissioning etc comp . as reqd complete with dismantling of old defective batteries . ( note:the old dismantled battery shall be the property of the agency . ) , 12v 7ah , 12v 26ah , refilling of existing 4 . 5 kg co2 in the existing 4 . 5 kg co2 type cylinder including transportation to the filling facility and back to concerned te bldg . including testing and commissioning complete etc as required . , supplying and fixing following items in the existing 4 . 5 kg co2 fire extinguishers i/c testing and commissioning etc as reqd . , horns with hose pipe , topping up of transformer oil with dielectric strength more than 40 kv in the existing transformer/ ocb etc . comp . as reqd . , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders/ change over switch in existing cubicle panel board including drilling holes in the cubicle panel making connections etc comp . as reqd . , 200/250 a , 65 ka , fpmccb , 250 amp . fp change over switch , providing and fixing following components in the existing capacitor panel suitable i/c making connections , testing and commissioning etc comp . as reqd . , 5kvar heavy duty cylindrical capacitor suitable for linear load , 10kvar heavy duty cylindrical capacitor suitable for linear load , plugging the leakage of the existing 200 kva transformer by providing suitable size of gasket etc . complete as per requirement at site . ...

Bharat Sanchar Nigam Limited - Punjab

27646332 operation and comprehensive maintenance of ems for te bldg at rayya jandiala guru majitha ajnala an comprehensive maintenance of ems for various rented buildings and group exchanges under sdca goindwa rayya jandiala guru majitha and ajnala sh clea , wet servicing of existing 1 . 5tr/2tr window/split ac unit i/c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i/c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split/wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing/flaring the leak points , vacumising , purging and making the system leak proof i/c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5/2 . 0 tr , replacement of following capacity of existing old defective compressor with new sealed compressor i/c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition/alteration i/c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i/c testing etc as reqd . ( m/s emerson/tecumseh/ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new/oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac/sac units i/c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( 80/100 mfd ) ( m/s epcos/asian/ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( m/s epcos/asian/ss make ) , repairing of control card pcb existing 1 . 5/2 . 0tr split ac units , condenser fan blade ( pvc/frp ) , condensor coil , replacement of control card pcb suitable for 1 . 5tr split ac units , blower fan motor for idu of split ac unit ( m/s aue/marathon ge/national/ diamond /ss make ) , thermostat ( m/s danfoss/indfoss/arvind/ss make , washable nylon air filter , replacement/rewinding of existing condenser motor of 1 . 5/2 tr split/window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , sitc of photo electric type smoke detector complete with detector base etc as reqd and as per bsnl specifications , sitc of electro pneumatic type dual action ( heat cum rate of rise in temperature ) heat detector complete with detector base etc as reqd and as per bsnl specifications . , providing repairs to the existing microprocessor based fire detection and fire alarm panel i/c replacement of transformer , control cards , pcb i/c making minor repairs to make the panel fully functional as per the directions of the engineer in charge . , replacement of following ampere hour capacity sealed maintenance free battery i/c making connections , testing and commissioning etc comp . as reqd complete with dismantling of old defective batteries . ( note:the old dismantled battery shall be the property of the agency . ) , 12v 7ah , 12v 26ah , refilling of existing 4 . 5 kg co2 in the existing 4 . 5 kg co2 type cylinder including transportation to the filling facility and back to concerned te bldg . including testing and commissioning complete etc as required . , supplying and fixing following items in the existing 4 . 5 kg co2 fire extinguishers i/c testing and commissioning etc as reqd . , horns with hose pipe , topping up of transformer oil with dielectric strength more than 40 kv in the existing transformer/ ocb etc . comp . as reqd . , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders/ change over switch in existing cubicle panel board including drilling holes in the cubicle panel making connections etc comp . as reqd . , 200/250 a , 65 ka , fpmccb , 250 amp . fp change over switch , providing and fixing following components in the existing capacitor panel suitable i/c making connections , testing and commissioning etc comp . as reqd . , 5kvar heavy duty cylindrical capacitor suitable for linear load , 10kvar heavy duty cylindrical capacitor suitable for linear load , plugging the leakage of the existing 200 kva transformer by providing suitable size of gasket etc . complete as per requirement at site . ...

Bharat Sanchar Nigam Limited - Punjab

27363116 rate contract for need base maintenance of ac package units in te bldgs at moga and abohar of ferozepur ba , attending and rectification of existing ac package units faults including providing minor spares if reqd such as connecting copper wires , removing & cleaning of filters , cleaning of units by blowers , control fuse , ferrules , lugs i / c minor works etc alongwith testing & commissioning complete as required . ( item will be measured on submission of visit report duly signed by bsnl authority and allowed at once per site per fault ) ( note: for subsequent visit to attend the ac package units to provide the items hereunder will not be paid separately . it is assumed that all items as below shall be carried out by firm in first visit only ) , wet servicing of existing 7 tr conventional / hpac removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i / c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , replacement of following capacity of existing old defective compressor with new sealed compressor in the existing conventional package ac unit including dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition / alteration i / c proper mounting on base plate , connection of suction and discharge lines etc as reqd . ( m / s emerson / tecumseh / ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new / oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 3 . 75 tr , replacement of following capacity of existing old defective compressor with new sealed compressor in the existing hpac unit including dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition / alteration i / c proper mounting on base plate , connection of suction and discharge lines including testing etc as reqd . ( m / s emerson / tecumseh / ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new / oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 7 tr , carrying out leak testing of existing 7 tr conventional / hpac package units with nitrogen gas including dismantling of machine , flushing the system , brazing / flaring the leak points , vacumising , purging and making the system leak proof i / c transportation of nitrogen cylinder , brazing kit & vacuum pump testing & commissioning etc as required . , supplying and installation of following material for repairing & attending break down complaints of 7tr conventional / hpac package ac units / electrical control panel i / c dismantling , connection , fixing & testing etc as required . ( note the firm shall submit test certificate or documentary proof towards purchase of new ) the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , blower motor ( rewinding ) , condenser motor ( rewinding ) for conventional ac units , condenser motor ( new ) for hpac units , lp / hp control switch , indication lamps , multifunctional vaf meter , thermostat ( m / s danfoss / indfoss / arvind / ss make ) , micro air filter , drier , expension valve , top up of r 22 refrigerant gas in the existing package type ac units , top up of r 407 refrigerant gas in the existing hpac package type ac units , minilec vsp d2 spp , ( a ) dial type discharge pressure gauge ( 0 500 psi ) , ( b ) dial type suction pressure gauge ( 0 300 psi ) , condenser fan blades , 25 tp contactor , 18 tp contactor , fieldbus / bms card controller , evd , lcd display , relay 2 . 5 to 5 amps , relay 12 to 18 amps , 6 32 amps tp mcb , supplying and installation of following size switches in the existing electrical panel including minor adjustments for fixing the switch in the panel including connections , testign and commissioning complete etc as required . , 200 amps tpn switch complete with hrc fuses , 63 amps tpn switch complete with hrc fuses , hrc fuses upto 63 amps , hrc fuses from 100 amps to 200 amps . , supplying and installation of 200 four pole mccb in the existing electrical panel including minor adjustments for fixing the switch in the panel including connections , testign and commissioning complete etc as required . , dismantling and reinstallstion of the existing condensor units of 7 tr hpac units including making necessary amendments as per the requirement at site , pump down the refrigerant , dismantling / cutting the existing refrigerant piping , reconnection of refrigerant piping , carrying out leakage testing and testing and commioning of complete unit etc as required . , supplying and fixing copper refrigerant pipes of suitable diameter with all accessories including cutting , bending , jointing , brazing etc . for hot gas and liquid lines of a single circuit , in existing ms cable tray including insulating the refrigerant lines inside ac area with suitable fire retardant polythene foam etc complete as required as per specifications attached . , hot gas line , 7 / 8 dia , liquid line , 5 / 8 dia , supplying and installing following size of perforated pre painted with powder coating m s cable trays with perforation not more than 17 . 5% , in convenient sections , joined with connectors , suspended from the ceiling with m s suspenders including bolts & nuts , painting suspenders etc as required . , 150 mm width x 50 mm depth x 1 . 6 mm thickness , providing and fixing 25 mm x 5 mm g . i . strip on surface or in recess for earthing connections etc . as required . , supplying and laying armoured copper cable of following sizes in existing cable tray including termination of cables etc as required . , 3 x 4 . 0 sq . mm copper cable...

Bharat Sanchar Nigam Limited - Punjab

27222052 operation comprehensive maintenance of ems for t e bldg at rayya jandiala guru majitha ajnala comprehensive maintenance of ems for various rented buildings group exchanges under sdca goindwal rayya jandiala guru majitha aajnala . shclearingofdefect operation comprehensive maintenance of ems for t e bldg at rayya jandiala guru majitha ajnala comprehensive maintenance of ems for various rented buildings group exchanges under sdca goindwal rayya jandiala guru majitha a ajnalashclearingofdefect , wet servicing of existing 1 . 5tr/2tr window/split ac unit i/c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i/c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split/wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing/flaring the leak points , vacumising , purging and making the system leak proof i/c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5/2 . 0 tr , replacement of following capacity of existing old defective compressor with new sealed compressor i/c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition/alteration i/c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i/c testing etc as reqd . ( m/s emerson/tecumseh/ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new/oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac/sac units i/c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( 80/100 mfd ) ( m/s epcos/asian/ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( m/s epcos/asian/ss make ) , repairing of control card pcb existing 1 . 5/2 . 0tr split ac units , condenser fan blade ( pvc/frp ) , condensor coil , replacement of control card pcb suitable for 1 . 5tr split ac units , blower fan motor for idu of split ac unit ( m/s aue/marathon ge/national/ diamond /ss make ) , thermostat ( m/s danfoss/indfoss/arvind/ss make , washable nylon air filter , replacement/rewinding of existing condenser motor of 1 . 5/2 tr split/window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , sitc of photo electric type smoke detector complete with detector base etc as reqd and as per bsnl specifications , sitc of electro pneumatic type dual action ( heat cum rate of rise in temperature ) heat detector complete with detector base etc as reqd and as per bsnl specifications . , providing repairs to the existing microprocessor based fire detection and fire alarm panel i/c replacement of transformer , control cards , pcb i/c making minor repairs to make the panel fully functional as per the directions of the engineer in charge . , replacement of following ampere hour capacity sealed maintenance free battery i/c making connections , testing and commissioning etc comp . as reqd complete with dismantling of old defective batteries . ( note:the old dismantled battery shall be the property of the agency . ) , 12v 7ah , 12v 26ah , refilling of existing 4 . 5 kg co2 in the existing 4 . 5 kg co2 type cylinder including transportation to the filling facility and back to concerned te bldg . including testing and commissioning complete etc as required . , supplying and fixing following items in the existing 4 . 5 kg co2 fire extinguishers i/c testing and commissioning etc as reqd . , horns with hose pipe , topping up of transformer oil with dielectric strength more than 40 kv in the existing transformer/ ocb etc . comp . as reqd . , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders/ change over switch in existing cubicle panel board including drilling holes in the cubicle panel making connections etc comp . as reqd . , 200/250 a , 65 ka , fpmccb , 250 amp . fp change over switch , providing and fixing following components in the existing capacitor panel suitable i/c making connections , testing and commissioning etc comp . as reqd . , 5kvar heavy duty cylindrical capacitor suitable for linear load , 10kvar heavy duty cylindrical capacitor suitable for linear load , plugging the leakage of the existing 200 kva transformer by providing suitable size of gasket etc . complete as per requirement at site . ...

Punjab Police Housing Corporation Limited - Punjab

27213361 annual maintenance contract of ac at sec 77 sas nagar annual comprehensive maintenance of diakin make 564 hp vrv air conditioning system at the intelligence headquarters , sector 77 , sas nagar ( for the period from 01 . 04 . 2021to 31 . 03 . 2022 ) , anual maintenance ( comprehensive ) of vrv airconditioning system . 564 hp capacity which includes 4 routine services ( 3dry & 1 wet ) and inrmediate attendance of break down , if any refrigerant gas charging replacement of compressor , pcbs magnetic switches transformem and fan motors etc . ( for the period of 01 . 04 . 2021 to 31 . 03 . 2022 ) please refer dnit for detailed scope of work . ...

National Institute Of Pharmaceutical Education And Research Niper - Punjab

27184107 supply of items 1 copper tubing dia 5 oblique 8 inches and 3 oblique 8 inches make totaline, meter 2 nitrile insulation sleeve for copper tubing 5 oblique 8 inches and 3 oblique 8 inches make nitlon oblique superion, meter 3 pvc insulated flexible copper wire for indoor unit 4c x 2 point 5 sqmm make havells oblique ecko oblique finolex or equivalent isi marked, meter 4 pvc flat batten for wire size 25mm (indoor unit to outdoor), meter 5 g i saddle clamp dia 65mm, no 6 pvc drainage pipe dia 25mm make diplast oblique supreme oblique atul, meter 7 clamp dia 20mm for drainage pipe, no 8 freon oblique hydrocarbon refrigerant gas r134a or equivalent as per oem standard make freon oblique rafron or equivalent, kg 9 ms sheet tray 20g bended to size 150mm x 50mm provision for screw for holding of cover and covered with ms sheet metal cover duly powder coated of required shade as per sample, meter...

Bharat Sanchar Nigam Limited - Punjab

27073593 operation comprehensive maintenance of ems for te bldg at rayya jandiala guru majitha ajnala comprehensive maintenance of ems for various rented buildings group exchanges under sdca goindwa rayya jandiala guru majitha ajnala sh cleari , wet servicing of existing 1 . 5tr/2tr window/split ac unit i/c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i/c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split/wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing/flaring the leak points , vacumising , purging and making the system leak proof i/c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5/2 . 0 tr , replacement of following capacity of existing old defective compressor with new sealed compressor i/c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition/alteration i/c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i/c testing etc as reqd . ( m/s emerson/tecumseh/ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new/oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac/sac units i/c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( 80/100 mfd ) ( m/s epcos/asian/ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( m/s epcos/asian/ss make ) , repairing of control card pcb existing 1 . 5/2 . 0tr split ac units , condenser fan blade ( pvc/frp ) , condensor coil , replacement of control card pcb suitable for 1 . 5tr split ac units , blower fan motor for idu of split ac unit ( m/s aue/marathon ge/national/ diamond /ss make ) , thermostat ( m/s danfoss/indfoss/arvind/ss make , washable nylon air filter , replacement/rewinding of existing condenser motor of 1 . 5/2 tr split/window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , sitc of photo electric type smoke detector complete with detector base etc as reqd and as per bsnl specifications , sitc of electro pneumatic type dual action ( heat cum rate of rise in temperature ) heat detector complete with detector base etc as reqd and as per bsnl specifications . , providing repairs to the existing microprocessor based fire detection and fire alarm panel i/c replacement of transformer , control cards , pcb i/c making minor repairs to make the panel fully functional as per the directions of the engineer in charge . , replacement of following ampere hour capacity sealed maintenance free battery i/c making connections , testing and commissioning etc comp . as reqd complete with dismantling of old defective batteries . ( note:the old dismantled battery shall be the property of the agency . ) , 12v 7ah , 12v 26ah , refilling of existing 4 . 5 kg co2 in the existing 4 . 5 kg co2 type cylinder including transportation to the filling facility and back to concerned te bldg . including testing and commissioning complete etc as required . , supplying and fixing following items in the existing 4 . 5 kg co2 fire extinguishers i/c testing and commissioning etc as reqd . , horns with hose pipe , topping up of transformer oil with dielectric strength more than 40 kv in the existing transformer/ ocb etc . comp . as reqd . , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders/ change over switch in existing cubicle panel board including drilling holes in the cubicle panel making connections etc comp . as reqd . , 200/250 a , 65 ka , fpmccb , 250 amp . fp change over switch , providing and fixing following components in the existing capacitor panel suitable i/c making connections , testing and commissioning etc comp . as reqd . , 5kvar heavy duty cylindrical capacitor suitable for linear load , 10kvar heavy duty cylindrical capacitor suitable for linear load , plugging the leakage of the existing 200 kva transformer by providing suitable size of gasket etc . complete as per requirement at site . ...

Bharat Sanchar Nigam Limited - Punjab

26873581 operation comprehensive maintenance of ems for te bldg at rayya jandiala guru majitha ajnala comprehensive maintenance of ems for various rented buildings group exchanges under sdca goindwa rayya jandiala guru majitha ajnala sh cleari , wet servicing of existing 1 . 5tr / 2tr window / split ac unit i / c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i / c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split / wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing / flaring the leak points , vacumising , purging and making the system leak proof i / c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5 / 2 . 0 tr , replacement of following capacity of existing old defective compressor with new sealed compressor i / c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition / alteration i / c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i / c testing etc as reqd . ( m / s emerson / tecumseh / ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new / oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac / sac units i / c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5 / 2 . 0 tr ( 80 / 100 mfd ) ( m / s epcos / asian / ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5 / 2 . 0 tr ( m / s epcos / asian / ss make ) , repairing of control card pcb existing 1 . 5 / 2 . 0tr split ac units , condenser fan blade ( pvc / frp ) , condensor coil , replacement of control card pcb suitable for 1 . 5tr split ac units , blower fan motor for idu of split ac unit ( m / s aue / marathon ge / national / diamond / ss make ) , thermostat ( m / s danfoss / indfoss / arvind / ss make , washable nylon air filter , replacement / rewinding of existing condenser motor of 1 . 5 / 2 tr split / window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , sitc of photo electric type smoke detector complete with detector base etc as reqd and as per bsnl specifications , sitc of electro pneumatic type dual action ( heat cum rate of rise in temperature ) heat detector complete with detector base etc as reqd and as per bsnl specifications . , providing repairs to the existing microprocessor based fire detection and fire alarm panel i / c replacement of transformer , control cards , pcb i / c making minor repairs to make the panel fully functional as per the directions of the engineer in charge . , replacement of following ampere hour capacity sealed maintenance free battery i / c making connections , testing and commissioning etc comp . as reqd complete with dismantling of old defective batteries . ( note:the old dismantled battery shall be the property of the agency . ) , 12v 7ah , 12v 26ah , refilling of existing 4 . 5 kg co2 in the existing 4 . 5 kg co2 type cylinder including transportation to the filling facility and back to concerned te bldg . including testing and commissioning complete etc as required . , supplying and fixing following items in the existing 4 . 5 kg co2 fire extinguishers i / c testing and commissioning etc as reqd . , horns with hose pipe , topping up of transformer oil with dielectric strength more than 40 kv in the existing transformer / ocb etc . comp . as reqd . , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders / change over switch in existing cubicle panel board including drilling holes in the cubicle panel making connections etc comp . as reqd . , 200 / 250 a , 65 ka , fpmccb , 250 amp . fp change over switch , providing and fixing following components in the existing capacitor panel suitable i / c making connections , testing and commissioning etc comp . as reqd . , 5kvar heavy duty cylindrical capacitor suitable for linear load , 10kvar heavy duty cylindrical capacitor suitable for linear load , plugging the leakage of the existing 200 kva transformer by providing suitable size of gasket etc . complete as per requirement at site ....

Bharat Sanchar Nigam Limited - Punjab

26254258 operation and comprehensive maintenance of ems for t e bldg at rayya jandiala guru majitha ajnala and comprehensive maintenance of ems for various rented buildings and group exchanges under sdca goindwal rayya jandiala guru majitha , ajnala risk cost , wet servicing of existing 1 . 5tr / 2tr window / split ac unit i / c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i / c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split / wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing / flaring the leak points , vacumising , purging and making the system leak proof i / c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5 / 2 . 0 tr , replacement of following capacity of existing old defective compressor with new sealed compressor i / c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition / alteration i / c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i / c testing etc as reqd . ( m / s emerson / tecumseh / ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new / oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac / sac units i / c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5 / 2 . 0 tr ( 80 / 100 mfd ) ( m / s epcos / asian / ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5 / 2 . 0 tr ( m / s epcos / asian / ss make ) , repairing of control card pcb existing 1 . 5 / 2 . 0tr split ac units , condenser fan blade ( pvc / frp ) , condensor coil , replacement of control card pcb suitable for 1 . 5tr split ac units , blower fan motor for idu of split ac unit ( m / s aue / marathon ge / national / diamond / ss make ) , thermostat ( m / s danfoss / indfoss / arvind / ss make , washable nylon air filter , replacement / rewinding of existing condenser motor of 1 . 5 / 2 tr split / window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , sitc of photo electric type smoke detector complete with detector base etc as reqd and as per bsnl specifications , sitc of electro pneumatic type dual action ( heat cum rate of rise in temperature ) heat detector complete with detector base etc as reqd and as per bsnl specifications . , providing repairs to the existing microprocessor based fire detection and fire alarm panel i / c replacement of transformer , control cards , pcb i / c making minor repairs to make the panel fully functional as per the directions of the engineer in charge . , replacement of following ampere hour capacity sealed maintenance free battery i / c making connections , testing and commissioning etc comp . as reqd complete with dismantling of old defective batteries . ( note:the old dismantled battery shall be the property of the agency . ) , 12v 7ah , 12v 26ah , refilling of existing 4 . 5 kg co2 in the existing 4 . 5 kg co2 type cylinder including transportation to the filling facility and back to concerned te bldg . including testing and commissioning complete etc as required . , supplying and fixing following items in the existing 4 . 5 kg co2 fire extinguishers i / c testing and commissioning etc as reqd . , horns with hose pipe , topping up of transformer oil with dielectric strength more than 40 kv in the existing transformer / ocb etc . comp . as reqd . , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders / change over switch in existing cubicle panel board including drilling holes in the cubicle panel making connections etc comp . as reqd . , 200 / 250 a , 65 ka , fpmccb , 250 amp . fp change over switch , providing and fixing following components in the existing capacitor panel suitable i / c making connections , testing and commissioning etc comp . as reqd . , 5kvar heavy duty cylindrical capacitor suitable for linear load , 10kvar heavy duty cylindrical capacitor suitable for linear load , plugging the leakage of the existing 200 kva transformer by providing suitable size of gasket etc . complete as per requirement at site ....

National Institute Of Pharmaceutical Education And Research Niper - Punjab

26128812 1 pvc drainage pipe dia 25mm make diplast oblique supreme oblique atul 2 nitrile insulation sleeve for copper tubing 5 oblique 8 inches and 3 oblique 8 inches make nitlon oblique superion 3 pvc flat batten for wire size 25mm (indoor unit to outdoor) 4 pvc insulated flexible copper wire for indoor unit 4c x 2 point 5 sqmm make havells oblique ecko oblique finolex or equivalent isi marked 5 ms sheet tray 20g bended to size 150mm x 50mm provision for screw for holding of cover and covered with ms sheet metal cover duly powder coated of required shade as per sample 6 clamp dia 20mm for drainage pipe 7 g i saddle clamp dia 65mm 8 copper tubing dia 5 oblique 8 inches and 3 oblique 8 inches make totaline 9 freon oblique hydrocarbon refrigerant gas r134a or equivalent as per oem standard make freon oblique rafron or equivalent...

Bharat Sanchar Nigam Limited - Punjab

26035311 supply, installation, testing, commissioning of 4x1 . 5 tr inverter type split ac units and water cooler at telepresence studio under nfs project at bathinda , supply of bee 5 star rated 1 . 5 tr inverter type split ac unit having nominal cooling capacity of 4500 kcal / hr ( 5 . 2 kw ) , minimum room air flow of 700 cub . mtr / hr and minimum indian seasonal energy efficient ratio ( iseer ) of 4 . 5 along with the copper piping and copper cable , up to the length of 3 mtrs including transportation etc . , complete as per specifications , terms and conditions attached as required . ( make: panasonic / universal comfort ( voltas ) / hitachi / lg / carrier / daikin / mitsubishi / o general / videocon / bluestar / samsung ) , supply of self contained drinking water cooler of 80 ltrs / hr cooling capacity and 80 ltrs sorage capacity confirming to is:1475 / 2001 ( part 1 ) suitable for operation on 230 v=10% 50 hz single phase ac supply complete as required . ( m / s sidwal , gujral , voltas , blue star ) , installation , testing and commissioning of 1 . 5 tr inverter type split ac unit along with the copper piping , wiring up to the standard length of 3 mtrs ( supplied as under item . 1 ) including insulation flexible pvc pipes and making opening in wall and making good the damages etc . , as required . , providing and fixing additional suction & discharge gas copper piping suitable for the above ac units , over and above 3 mtrs length where ever required including insulation covering , required refrigerant gas top up etc . , as required . , providing and fixing suitable size / dia pvc flexible heavy duty pipe for drain water arrangement for the above ac units complete as required . , supplying and fixing of powder coated heavy duty iron stand for mounting outdoor unit of the above ac i / c providing necessarary hardware etc complete as required . , supplying and fixing of ms iron stand made of 32x32x5mm angular for mounting outdoor unit of the above ac i / c cutting , welding , grouting , painting and minor civil works etc complete as required . ( to be provided wherever wall stands are not feasible ) , providing and fixing additional 3x2 . 5 sqmm pvc insulated copper conductor cable over and above 3 mtrs length suitable for the above ac units where ever required including terminations . , as required . , itc of existing 90 ltr storage capacity water cooler including p / f angle valves for water inlet control , pvc connections and making electrical and water connections etc complete as required . , sitc of 30 w led type street light fitting including all accessories and 1 mtr long gi brcket 38 mm dia along the wall with clamps etc i / c connections with 3x1 . 5 sq mm frls pvc insulated copper conductor single core cable and earthing etc as required . ( m / s crompton / philips / havells / bajaj / wipro make ) , sitc of 4 . 5 kg co2 type fire extinguishers suitable for extinguishing class b , c fire complete with all accessories i / c hose , pipe / horn etc confirming to is : 15683 / 2006 as reqd . isi marked & eil approved ....

Bharat Sanchar Nigam Limited - Punjab

25109226 providing ems for nfs site pkg . i at halwara . sh sitc of 5 nos 1 . 5tr inverter type split ac units . , part a supply portion , supply of bee 5 star rated 1 . 5 tr inverter type split ac unit having nominal cooling capacity of 4500 kcal/hr ( 5 . 2 kw ) , minimum room air flow of 700 cub . mtr/hr and minimum indian seasonal energy efficient ratio ( iseer ) of 4 . 5 along with the copper piping and copper cable , up to the length of 3 mtrs including transportation etc . , complete as per specifications , terms and conditions attached as required . ( make: panasonic / universal comfort ( voltas ) / hitachi / lg / carrier / daikin / mitsubishi / o general / videocon / bluestar / samsung ) , part b itc , installation , testing and commissioning of 1 . 5 tr inverter type split ac unit along with the copper piping , wiring up to the standard length of 3 mtrs ( supplied as under item . 1 ) including insulation flexible pvc pipes and making opening in wall and making good the damages etc . , as required . , providing and fixing additional suction & discharge gas copper piping suitable for the above ac units , over and above 3 mtrs length where ever required including insulation covering , required refrigerant gas top up etc . , as required . , providing and fixing suitable size / dia pvc flexible heavy duty pipe for drain water arrangement for the above ac units complete as required . , supplying and fixing of powder coated heavy duty iron stand for mounting outdoor unit of the above ac i/c providing necessarary hardware etc complete as required . , supplying and fixing of ms iron stand made of 32x32x5mm angular for mounting outdoor unit of the above ac i/c cutting , welding , grouting , painting and minor civil works etc complete as required . ( to be provided wherever wall stands are not feasible ) , providing and fixing additional 3x2 . 5 sqmm pvc insulated copper conductor cable over and above 3 mtrs length suitable for the above ac units where ever required including terminations . , as required . ...

Bharat Sanchar Nigam Limited - Punjab

24591932 operation and comprehensive mtce of ems for te bldg and staff qtrs at gurdaspur and comprehensive mtce of various group exchanges under sdca gurdaspur sh attending the defects at risk and cost of ms cooledge engineers new delhi , general servicing of following capacity of dea sets of different makes and models under various exchanges comprising of following jobs i/c transportation , labour charges & material required for servicing i/c minor material required for healthyness of dg set etc . as reqd . ( i ) cleaning & greasing of the parts . ( ii ) tappet setting as per standard ( iii ) fan belt , tensioner pulley and lever adjustments . ( iv ) tightening of all the nuts , bolts and clamps . ( v ) testing & checking of ac & dc wiring . ( vi ) self & charging alternator cleaning and testing , checking of working & minor fault removal . ( vii ) checking of supply & return fuel pipes from fuel tank to engine . ( viii ) replacement of consumables like lub oil , diesel filter , oil filter , filter element of air cleaner & coolant ( in case of water cooled engines ) . ( ix ) checking of fip timing by fuel cut off method . ( x ) general servicing i/c cleaning of dg panel ( xi ) general servicing & complete cleaning of dg set , 110 kva , 75 kva , 50 kva , 40 kva , 15 kva , providing maintenance free new lead acid batteries as a replacement of existing old batteries of following types/rating complete with first fill of electrolyte & first charging i/c replacement of leads , nut bolts , terminals/thimbles complete as reqd . ( the old batteries shall be the property of contractor and rates shall be quoted accordingly ) , 12 v , 150 ah , 12v , 130 ah , 12v , 26 ah , replacement of following defective accessories in the existing dg sets with new accessories , complete as reqd . [ dismantled defective accessories shall belong to vendor , credit for same has to be considered while quoting rates . ] , stop solinoid 12 volt ( engine shut off solenoid ) , mechanical type rpm cum hour meter , rpm cum hour meter chain , 12 volt electrical battery charger i/c transformer , rectifier unit and filter circuit etc . complete as reqd . , oil pressure meter , oil temperature meter with safety , water temperature meter , starting key switch , 100 amps 4 pole mccb 25 ka , voltmeter with selector switch , ampere meter with selector switch , ct measuring ( ct ratio shall be decided by e in c as per site requirement ) , wet servicing of existing 1 . 5tr/2tr window/split ac unit i/c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i/c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split/wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing/flaring the leak points , vacumising , purging and making the system leak proof i/c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5/2 . 0 tr , 4 . 5 tr , replacement of following capacity of existing old defective compressor with new sealed compressor /oem factory repaired compressor i/c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition/alteration i/c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i/c testing etc as reqd . ( m/s emerson/tecumseh/ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new/oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following capacity of existing old defective compressor with new sealed compressor /oem factory repaired compressor i/c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition/alteration i/c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i/c testing etc as reqd . ( m/s emerson/tecumseh/ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new/oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 2 . 0 tr , replacement of following capacity of existing old defective compressor in 9 tr package type ac unit with new sealed compressor of model cr 52/cr 57 / ag5560f i/c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition/alteration i/c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i/c testing etc as reqd . ( m/s emerson/tecumseh/ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new/oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac/sac units i/c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( 80/100 mfd ) ( m/s epcos/asian/ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( m/s epcos/asian/ss make ) , repairing of control card pcb existing 1 . 5/2 . 0tr split ac units , box type relay for window ac units . ( m/s arvind/ranutrol/ss make ) , selector switch for window ac units , blower fan motor for idu of split ac unit ( m/s aue/marathon ge/national/ diamond /ss make ) , thermostat ( m/s danfoss/indfoss/arvind/ss make , washable nylon air filter , replacement/rewinding of existing condenser motor of 1 . 5/2 tr split/window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , replacement of following material for 9 tr package type ac ...

Indian Institute Of Science Education And Research - Punjab

23375069 tender for modification in 4tl1 lab of dr anoop ambili in ab 2 at iiser mohali 1 variable refrigerant volume modular type air conditioning system suitable for cooling and heating by using all inverter driven capacity control compressors complete with indoor and outdoor units, cop at 100% should be minimum 3.5 at 35 c ( ahri conditions ) with individual controller, electronic expansion valve and fittings etc. as per quantity given below including full charging of r 410a refrigerant gas ( according to piping length ) , temperature remote control complete i / c powder coating complete as per specifications including lifting positioning, etc at all floors / heights. ( make: samsung ) . 2 6 hp ( connected to ahu ) 3 with following assembly, erection, testing and commissioning of imported fittings y joints and headers etc 4 refrigerant piping 5 with following interconnecting pipes one end expanded refrigerant copper pipe work for variable refrigerant volume units of following outer diameter, insulated with 19 / 13 mm thick xlpe closed cell electrometric nitrile rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of alluminum cladding for all exposed pipes as per specification. 6 28.6 mm dia with 19mm thick nitrile rubber insulation 7 19.1 mm dia with 13mm thick nitrile rubber insulation 8 12.7 mm dia with 13mm thick nitrile rubber insulation 9 9.5 mm dia with 13mm thick nitrile rubber insulation 10 instrumentation cable ( copper armoured ) . 11 4 x 16 sq.mm 12 3 x 1.5 sq.mm...

Diesel Loco Modernization Works - Punjab

21735448 supply of supply of refrigerant gas r 32 & r 410a., supply of refrigerant gas r 32 [ in sealed cylinder 45 kg.] with cylinder refrigerant make stallion/freon/mefron., supply of refrigerant gas r 410a [ in sealed cylinder 45 kg.] with cylinder refrigerant make stallion/freon/mefron....

Indian Air Force - Punjab

21608775 invitation of bids under single bid system on lte basis for procurement of refrigerant gas qty 122 kg rfp no . 19 20/501su/ltd/tdr/000011 dated 30 aug 2019 invitation of bids under single bid system on lte basis for procurement of refrigerant gas qty 122 kg rfp no . 19 20/501su/ltd/tdr/000011 dated 30 aug 2019...

Military Engineer Services - Punjab

21331925 repair to water cooler at mil stn sangrur , taking down unserviceable water cooler 40/80 litre cap . from any position . and removing unserviceable burnt sealed unit ( compressor ) from cooler and s & f new compressor unit and testing on required pressure and installing cooler at its original position . all as specified and directed . note : cost of filling with refrigerant gas is included in unit rate of this item . make of compressor : usha / sidwall / coolstar / sriram , supply & replacement of thermostat switch suitable for water coolers including knobs , plate and screws complete ass as specified and directed . make : ranutral / denfoss , supply and replacement running capacitor suitable for water cooler 40/80/ ltr capacity complete all as specified and directed . make : usha/unistar , supply & replacement of starting relay assembly including replacement of cover and clips suitable for water coolers of capacity 40/80 ltr complete as specified and directed . , supplying and replacement of over load protector for water cooler 40/ 80 litre cap . complete all as directed . make : renutrol/sri ram /indofoss , supplying and replacement of starting capacitor for water cooler 40/80 litre cap . complete all as directed . , taking down old unserviceable fan motor & s&f new fan motor suitable for water cooler of cap 80/40 ltrs capacity . make cool home/aue/crompton . of following capacity . note : all items retrieved from this sec of sch . shall be property of contractor and contractor shall afford credit for this account as per sch of credit . , supply and replacement water tap 15 mm dia , self closing , chromium plated push cock heavy duty ( as per existing ) complete all as specified and directed . , cleaning of water cooler body of capacity 40/80/150 ltrs internally and externally including scraping and removing all scales and dirt etc . repair to body to stop leakage and replacing unserviceable screws , nut & bolts etc . spray painting of water cooler with synthetic enamel paint hammer tone paint including preparation of surfaces and applying red oxide primer all as directed at site . , supplying and replacement pvc flexible copper cable 3 core 40/0 . 0076 length complete all specified and directed , carrying out leak check and rectifying / arresting same by brazing to copper tubing and recharging refrigerant gas commissioning and testing to entire satisfaction of engineer in charge for water cooler including cost of gas to be filled . , servicing of aqua guard of any description complete by the manufacturer technician as directed by the engr in charge as per standard norms of the manufacturer . ( unserviceable spares shall be measured and paid separately ) , replacement of candle , replacement of carbon filter , pvc pipe 1/4 dia for inlet/outlet water connection , suction/delivery ro motor...

Military Engineer Services - Punjab

21186919 repair to water cooler at mil stn sangrur , taking down unserviceable water cooler 40/80 litre cap . from any position . and removing unserviceable burnt sealed unit ( compressor ) from cooler and s & f new compressor unit and testing on required pressure and installing cooler at its original position . all as specified and directed . note : cost of filling with refrigerant gas is included in unit rate of this item . make of compressor : usha / sidwall / coolstar / sriram , supply & replacement of thermostat switch suitable for water coolers including knobs , plate and screws complete ass as specified and directed . make : ranutral / denfoss , supply and replacement running capacitor suitable for water cooler 40/80/ ltr capacity complete all as specified and directed . make : usha/unistar , supply & replacement of starting relay assembly including replacement of cover and clips suitable for water coolers of capacity 40/80 ltr complete as specified and directed . , supplying and replacement of over load protector for water cooler 40/ 80 litre cap . complete all as directed . make : renutrol/sri ram /indofoss , supplying and replacement of starting capacitor for water cooler 40/80 litre cap . complete all as directed . , taking down old unserviceable fan motor & s&f new fan motor suitable for water cooler of cap 80/40 ltrs capacity . make cool home/aue/crompton . of following capacity . note : all items retrieved from this sec of sch . shall be property of contractor and contractor shall afford credit for this account as per sch of credit . , supply and replacement water tap 15 mm dia , self closing , chromium plated push cock heavy duty ( as per existing ) complete all as specified and directed . , cleaning of water cooler body of capacity 40/80/150 ltrs internally and externally including scraping and removing all scales and dirt etc . repair to body to stop leakage and replacing unserviceable screws , nut & bolts etc . spray painting of water cooler with synthetic enamel paint hammer tone paint including preparation of surfaces and applying red oxide primer all as directed at site . , supplying and replacement pvc flexible copper cable 3 core 40/0 . 0076 length complete all specified and directed , carrying out leak check and rectifying / arresting same by brazing to copper tubing and recharging refrigerant gas commissioning and testing to entire satisfaction of engineer in charge for water cooler including cost of gas to be filled . , servicing of aqua guard of any description complete by the manufacturer technician as directed by the engr in charge as per standard norms of the manufacturer . ( unserviceable spares shall be measured and paid separately ) , replacement of candle , replacement of carbon filter , pvc pipe 1/4 dia for inlet/outlet water connection , suction/delivery ro motor...