Rail Coach Factory - Punjab

34136438 supply of supply, installation and commissioning of brake module for conversion of already available automatic smoke / fire detection rake form system to standalone automatic smoke / fire detection systemsupply, installation and commissioning of brake module for conversion of already available automatic smoke / fire detection rake form system to standalone automatic smoke / fire detection system, supply, installation and commissioning of brake module for conversion of already available automatic smoke / fire detection rake form system to standalone automatic smoke / fire detection system ( plno.33691654 ) for lhb ac coaches., as per drawing: rdso / 2008 / cg 04 rev.05 and follow design lno. md22161 dated 18.08.21 for provision of aspiration type smoke detector ( sampling ponts ) in lavatories in place of hasp., packing instruction: as per standard packing. it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage , if any , shall be at the cost of supplier....

Indian Army - Punjab

34113268 bids are invited for inverter battery and smoke detector impact inverter microtek , battery , smoke detector impact total quantity : 19...

Rail Coach Factory - Punjab

34080030 supply of automatic smoke / fire detection system for stand alone lhb ac chair carautomatic smoke / fire detection system for stand alone lhb ac chair car, automatic smoke / fire detection system for stand alone lhb ac chair car., as per drawing: rdso / 2008 / cg 04 rev.05 and follow design l.no. md22161 dated 18.08.21. for provision of aspiration type smoke detector ( sampling ponts ) in lavatories in place of hasp., installation & commissioning:inclusive packing instruction: as per standard packing. it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage , if any , shall be at the cost of supplier. => limited...

Dr Br Ambedkar National Institute Of Technology - Punjab

34042795 repair of room no. 302 ( msc block ) providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) : with float glass panes of 8 mm thickness ( weight not less than 20 kg / sqm ) dsr 21.3.3 3 providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams / sqm, both side inclusive ) consisting of main t runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick ( minimum ) sheet, spaced at 1200 mm center to center and cross t of size 24x25 mm made of 0.30 mm thick ( minimum ) sheet, 1200 mm long spaced between main t at 600 mm center to center to form a grid of 1200x600 mm and secondary cross t of length 600 mm and size 24x25 mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge.gi metal ceiling lay in perforated tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of gi sheet having galvanizing of 100 gms / sqm ( both sides inclusive ) and 20% perforation area with 1.8 mm dia holes and having nrc ( noise reduction coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns ( minimum ) , including factory painted after bending and perforation, and backed with a black glass fiber acoustical fleece.dsr 12.52.2 4 providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from m.s. sheets and galvanized with zinc coating of 120 gms / sqm ( both side inclusive ) as per is : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate g.i. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to g.i. ermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c / c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the engineer in charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to is: 2095 ( part i ) : 2011 ( board with bis certification marks ) dsr 12.45.1 ( unit in sq m ) 5 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600mm dsr 11.41.2 6 removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. completedsr 13.88 7 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. i / c rwmoving old paint / hand scrapping etcdsr 13.8 8 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :new work ( two or more coats ) over and including water thinnable priming coat with cement primer. dsr 13.41.1 9 providing and laying vitrified tiles in different sizes ( thickness to be specified by manufacturer ) , with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 ( 1 cement: 3 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joint with white cement & matching pigments etc. completedsr 11.46.3 10 provinding and fixing aluminium snap beading in door and window with all fitting...

Rail Coach Factory - Punjab

33499278 supply of automatic smoke/fire detection systemautomatic smoke/fire detection system,automatic smoke/fire detection system for stand alone in lhb ac sleeper coaches., as per drawing: rdso/2008/cg 04 rev.05 and follow design l. no. md22161 dated 18.08.21 for provision of aspiration type smoke detector (sampling points) in lavatories in place of hasp. installation & commissioning: inclusive. packing instruction: as per standard packing. it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage , if any , shall be at the cost of supplier. => limited...

Rail Coach Factory - Punjab

32161092 supply of automatic smoke/fire detection system for stand alone in lhb ac sleeper coaches.automatic smoke/fire detection system for stand alone in lhb ac sleeper coaches.,automatic smoke/fire detection system for stand alone in lhb ac sleeper coaches., as per drawing: rdso/2008/cg 04 rev.05 and follow design l. no. md22161 dated 18.08.21 for provision of aspiration type smoke detector (sampling points) in lavatories in place of hasp. installation & commissioning: inclusive. packing instruction: as per standard packing. it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage , if any , shall be at the cost of supplier....

Rail Coach Factory - Punjab

31578458 supply of smoke detector unit for lhb eog coachessmoke detector unit for lhb eog coaches,smoke detector unit for lhb eog coaches, as per drawing: edts087, rev b,corr 1, packing instruction: alternator,rru, erru & accessories, transformer,bulk inverters , battery, charger, self priming monoblock pump, inverter, change over control box etc: suitably covered with biodegradable transparent polythene and packed in wooden cage: bottom frame to be made of wooden planks 20mm thick & should have support of at least 3 wooden battons of size 100x100mm of suitable length to facilitate lifting by fork lifter. each panel to be packed in wooden cage of suitable dimensions made out of wooden strips of 20x100mm size. gap between each strip should not be more then 100mm. the material used for product packaging shall be eco friendly.a list should be pasted on each wooden cage showing order no, pl no, description of the item, drg. no/ spec. no ,qty, firms name & address and date of despatch etc....

Indian Army - Punjab

31547457 bids are invited for smoke detector cum fire extinguisher 400ml wall mounted total quantity : 19...

Rail Coach Factory - Punjab

31333963 supply of automatic smoke/fire detection system for stand alone in lhb ac sleeper coaches.automatic smoke/fire detection system for stand alone in lhb ac sleeper coaches.,automatic smoke/fire detection system for stand alone in lhb ac sleeper coaches., as per drawing: rdso/2008/cg 04 rev.05 and follow design lno. md22161 dated 18.08.21 for provision of aspiration type smoke detector (sampling ponts) in lavatories in place of hasp. installation & commissioning: inclusive. packing instruction: as per standard packing. it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage , if any , shall be at the cost of supplier....

Indian Army - Punjab

30594895 bids are invited for item no 1 ousourcing for maintenance & operation of chilled water central ac plant 3 x 30 tr 03 nos (working 02 nos and01 no stand by) and manning and operation of diesel generator set of 250kvainstalled at plant with connected panels and two dg sets of 50 kva capacity at 4 x amn shed by employing one technically qualified skilled ac operator in each shift of 08 (eight) hrs each for 3 (three shifts)round the clock daily including sunday and holidays comprising of the following equipments. (a)smooth functioning of entire ac plant and to maintain the specific temprature between 15 to 25 degree cetigrate and rh 65 + 5% all as specified and directed. (i)hermatically sealed receprocal type compressor including meter etc 03 nos complete. (ii)shell & tube condensers. (iii)ahu unit at destance of approx 125 meter from plant room with heating and cooling coil and blower motors. (iv)mono block pump set for circulation of chilled water for ahu. (v)chiller for chilled water system capacity 30 tr = 03 nos. (vi)mono block pumping set for condenser water circulation.vii) electric control panel cubical type in plant room.(ix)ducting for supply air with grills, diffusers and fire dampers/smoke detector, fire protection alarm in plant room. (x)coolinjg tower frp induced draft couter flow single shell 78 tr capacity with axial flow fan of cast aluminium including electric motor 3 phase 415 volts, 2 hp capacity with water make up pvc tank 2000 ltr capacity = 01 no.(xiii)humiditifier. (xv)condensor, chiller and hot water pipe line with control valve complete. (xvi)pan type humiditer made out of ss sheet = 02 nos. (xvii)condenser, chiller and hot water pipe line complete with control valve. (xviii)servo voltage stablizer cap 200 kva 3 phase 415 v, 50 hz = 01 nos. (xix)voltage stabilizer cpaicity 200 watt = 01 nos. , item no 1.1 as per item no 1.00 above but, epf as notified by the govt (as per notes given in financial evaluation criteria as detailed in the tende...

Indian Army - Punjab

30583339 bids are invited for item no 1 outsourcing of service for maintenance & operation of air cooled central ac plant 2 x 50 tr 12 nos (01 working and 01 no stand by) and manning and operation of diesel generator set of 1010 kva 03 nos installed at plant with connected panels by employing one technically qualified skilled refg. mech. ac operator , comprising of the components detailed as below round the clock daily in 03 (three) shifts of 08 hrs including sunday and holiday. the operator detailed at ac plant shall be for: (a)smooth functioning of entire ac plant and to maintain the specific temprature between 25 + 2 degree centigrade and rh 50 +5% as specfied by engr in charge all as specified and directed.(i)hermatically sealed scroll type compressor including meter etc 72 nos complete. (ii)fin & tube condensers. (iii)ahu unit atwith heating and cooling coil and blower motors. (iv)mono block pump set for circulation of chilled water for ahu. (v)chiller for chilled water system capacity 50 tr each. (vi)mono block pumping set for condenser water circulation. (vii) electric control panel cubical type in plant room. (viii)control valve such as expansion valve.thermostat, humidistat, solenoid, valve, hand shut of valve, antifreeze thermostate and ancilliaries such as gauges, etc installed in each chiller units. (ix)ducting for supply air with grills, diffusers and fire dampers/smoke detector, fire protection alarm in plant room. (x) monoblock pump set for hot water generator. (xi)electric control microprocesser based control panel. (xii)hot water generator with electric control panel. (xiii)humidifier. (xiv) condensor, chiller and hot water pipe line with control valve complete. (xv)pan type humidifier made out of ss sheet = 02 nos. (xvi)condenser, chiller and hot water pipe line complete with control valve. , item no 1.1 as per item no 1.00 above but, epf as notified by the govt (as per notes given in financial evaluation criteria as detailed in the tender documents...

National Fertilizers Limited - Punjab

30429663 fire dectection and alarm system st/2020/69/2 fire dectection and alarm system , microprocessor based addressable main fire alarm control panel facp 1 with 2 loops located at mrss substation (urea) with alarm indication of all zones (facp 1 & facp 2), with its own battery and battery charger. , microprocessor based addressable fire alarm control panel facp 2with 2 loops located at old ammonia substation withalarm indication of all zones (facp 1 & facp 2) with its own battery and battery charger , microprocessor based central monitoring station repeater control panel (rcp) located in the nfl fire stationwith alarm indication of all zones and detectors/devices (facp 1 & facp 2) with its own battery and battery charger , a master system laptop with printer (workstation) for controlling / programming of fire alarm control panel (facp 2), repeater control panel (rcp) and main fire alarm panel (facp 1). , non addressable manual call points , non addressableis (intrinsically safe) manual call points for hazardous area (gas group iia/iib) , non addressable smoke detectors / heat detectors as per site requirement , non addressable is (intrinsically safe) smoke detectors / heat detectors for hazardous area (gas group iia/iib) as per site requirement , non addressable electronic hooters/sounders , non addressable beacon/flashers , control cables 1.1 kv grade to is: 1554, overall frls sheath, screened armoured & twisted size: 2c x 1.5 mm 2. , redundant optical cables between fire panels and repeater panel with ring topology , smoke detector/ heat detector removal and test toolkit , supply of mandatory recommended accessories / any other item not listed in the bom but required for the functioning of the system must also be quoted separately. , installation, testing and commissioning charges of fire dection & alarm system as per annexure i (if any)...

Indian Army - Punjab

30281130 bids are invited for item no 1 ousourcing for maintenance & operation of chilled water central ac plant 3 x 30 tr 03 nos (working 02 nos and01 no stand by) and manning and operation of diesel generator set of 250kvainstalled at plant with connected panels and two dg sets of 50 kva capacity at 4 x amn shed by employing one technically qualified skilled ac operator in each shift of 08 (eight) hrs each for 3 (three shifts)round the clock daily including sunday and holidays comprising of the following equipments.(a)smooth functioning of entire ac plant and to maintain the specific temprature between 15 to 25 degree cetigrate and rh 65 + 5% all as specified and directed. (i)hermatically sealed receprocal type compressor including meter etc 03 nos complete.(ii)shell & tube condensers. (iii)ahu unit at destance of approx 125 meter from plant room with heating and cooling coil and blower motors. (iv)mono block pump set for circulation of chilled water for ahu. (v)chiller for chilled water system capacity 30 tr = 03 nos. (vi)mono block pumping set for condenser water circulation.vii) electric control panel cubical type in plant room.(ix)ducting for supply air with grills, diffusers and fire dampers/smoke detector, fire protection alarm in plant room. (x)coolinjg tower frp induced draft couter flow single shell 78 tr capacity with axial flow fan of cast aluminium including electric motor 3 phase 415 volts, 2 hp capacity with water make up pvc tank 2000 ltr capacity = 01 no.(xiii)humiditifier. (xv)condensor, chiller and hot water pipe line with control valve complete. (xvi)pan type humiditer made out of ss sheet = 02 nos. (xvii)condenser, chiller and hot water pipe line complete with control valve. (xviii)servo voltage stablizer cap 200 kva 3 phase 415 v, 50 hz = 01 nos. (xix)voltage stabilizer cpaicity 200 watt = 01 nos. , item no 1.1 as per item no 1.00 above but, epf as notified by the govt (as per notes given in financial evaluation criteria as detailed in the tender ...

Indian Army - Punjab

30281069 bids are invited for item no 1 outsourcing of service for maintenance & operation of air cooled central ac plant 2 x 50 tr 12 nos (01 working and 01 no stand by) and manning and operation of diesel generator set of 1010 kva 03 nos installed at plant with connected panels by employing one technically qualified skilled refg. mech. ac operator , comprising of the components detailed as below round the clock daily in 03 (three) shifts of 08 hrs including sunday and holiday. the operator detailed at ac plant shall be for: (a)smooth functioning of entire ac plant and to maintain the specific temprature between 25 + 2 degree centigrade and rh 50 +5% as specfied by engr in charge all as specified and directed.(i)hermatically sealed scroll type compressor including meter etc 72 nos complete. (ii)fin & tube condensers. (iii)ahu unit atwith heating and cooling coil and blower motors. (iv)mono block pump set for circulation of chilled water for ahu. (v)chiller for chilled water system capacity 50 tr each. (vi)mono block pumping set for condenser water circulation. (vii) electric control panel cubical type in plant room. (viii)control valve such as expansion valve.thermostat, humidistat, solenoid, valve, hand shut of valve, antifreeze thermostate and ancilliaries such as gauges, etc installed in each chiller units. (ix)ducting for supply air with grills, diffusers and fire dampers/smoke detector, fire protection alarm in plant room. (x) monoblock pump set for hot water generator. (xi)electric control microprocesser based control panel. (xii)hot water generator with electric control panel. (xiii)humidifier. (xiv) condensor, chiller and hot water pipe line with control valve complete. (xv)pan type humidifier made out of ss sheet = 02 nos. (xvi)condenser, chiller and hot water pipe line complete with control valve. , item no 1.1 as per item no 1.00 above but, epf as notified by the govt (as per notes given in financial evaluation criteria as detailed in the tender documents...

Rail Coach Factory - Punjab

29621995 supply of automatic smoke/fire detection with alarm system.automatic smoke/fire detection with alarm system.,design,supply, installation, commissioning & maintenance of set of ccu(centralised control unit) with brake application with guard emergency brakevalve in guard compartment for automatic smoke/fire detection system for lhbpower car coaches suitable for lhb tejas rake sleeper coaches., as per rdso spec.no.: rdso/2008/cg 04 rev. 05 and follow design lno. md22161 dated 18.08.21 for provisionof aspiration type smoke detector (sampling ponts) in lavatories in place of hasp.,packing instruction: as per standard packing. it should be ensured that item should notrub during transportation. the item should be packed with adequate strength.transit damage , if any , shall be at the cost of supplier. , design, supply, installation, commissioning and maintenance of aspirationtype automatic smoke/fire detection with alarm system for tejas sleeper coachesrake (set consists of laccnhx 12, laccwhx 05, lfachx 02,lcbachx 01 and llrmtx 02)total=22 coaches. lcbachx and llrmtx are without detection and alarm system butllrmtx with ccu with brake application with guard emergency brake valve only., asper rdso spec. no.: rdso/2008/cg 04 rev.05 and follow design lno. md22161 dated 18.08.21for provision of aspiration type smoke detector (sampling ponts) in lavatories inplace of hasp., packing instruction: as per standard packing. it should be ensured thatitem should not rub during transportation. the item should be packed withadequate strength. transit damage , if any , shall be at the cost of supplier.installation & commissioning inclusive....

Ministry Of Home Affairs - Punjab

29281606 bids are invited for main fire pump refer to specification document annexure a. , diesel fire pump refer to specification document annexure a. , jockey pump refer to specification document annexure a. , terrace pump refer to specification document annexure a. , repairing of control panel refer to specification document annexure a. , 250 dia ms pipe refer to specification document annexure a. , 200 dia ms pipe refer to specification document annexure a. , 150 dia ms pipe refer to specification document annexure a. , 100 dia ms pipe refer to specification document annexure a. , 80 dia ms pipe refer to specification document annexure a. , 65 dia ms pipe refer to specification document annexure a. , 50 dia ms pipe refer to specification document annexure a. , 40 dia ms pipe refer to specification document annexure a. , 32 dia ms pipe refer to specification document annexure a. , 25 dia ms pipe refer to specification document annexure a. , supply 250 dia ms pipe refer to specification document annexure a. , supply 200 dia ms pipe refer to specification document annexure a. , supply 150 dia ms pipe refer to specification document annexure a. , supply 100 dia ms pipe refer to specification document annexure a. , supply 80 dia ms pipe refer to specification document annexure a. , supply 65 dia ms pipe refer to specification document annexure a. , supply 50 dia ms pipe refer to specification document annexure a. , supply 40 dia ms pipe refer to specification document annexure a. , supply 32 dia ms pipe refer to specification document annexure a. , supply 25 dia ms pipe refer to specification document annexure a. , joint 150 mm refer to specification document annexure a. , joint 100 mm refer to specification document annexure a. , joint 80 mm refer to specification document annexure a. , laying in trenches ms pipe 150 mm dia refer to specification document annexure a. , laying in trenches ms pipe 100 mm dia refer to specification document annexure a. , laying in trenches ms pipe 80 mm dia refer to specification document annexure a. , testing ci sluice valve 200 mm refer to specification document annexure a. , testing ci sluice valve 150 mm refer to specification document annexure a. , testing ci sluice valve 100 mm refer to specification document annexure a. , testing ci sluice valve 80 mm refer to specification document annexure a. , sitc 200 mm refer to specification document annexure a. , sitc 150 mm refer to specification document annexure a. , sitc 100 mm refer to specification document annexure a. , sitc 80 mm refer to specification document annexure a. , servicing of butterfly valve 200 refer to specification document annexure a. , servicing of butterfly valve 150 refer to specification document annexure a. , servicing of butterfly valve 100 refer to specification document annexure a. , servicing of butterfly valve 80 refer to specification document annexure a. , servicing of butterfly valve 50 refer to specification document annexure a. , sitc butterfly valve 200 refer to specification document annexure a. , sitc butterfly valve 150 refer to specification document annexure a. , sitc butterfly valve 100 refer to specification document annexure a. , sitc butterfly valve 80 refer to specification document annexure a. , sitc butterfly valve 50 refer to specification document annexure a. , servicing of nrv 200 refer to specification document annexure a. , servicing of nrv 150 refer to specification document annexure a. , servicing of nrv 100 refer to specification document annexure a. , servicing of nrv 80 refer to specification document annexure a. , servicing of nrv 65 refer to specification document annexure a. , servicing of nrv 50 refer to specification document annexure a. , supply of nrv 200 refer to specification document annexure a. , supply of nrv 150 refer to specification document annexure a. , supply of nrv 100 refer to specification document annexure a. , supply of nrv 80 refer to specification document annexure a. , supply of nrv 65 refer to specification document annexure a. , supply of nrv 50 refer to specification document annexure a. , orifice plate refer to specification document annexure a. , gun metal 25 refer to specification document annexure a. , gun metal 50 refer to specification document annexure a. , rubber expansion joint 65 refer to specification document annexure a. , rubber expansion joint 80 refer to specification document annexure a. , rubber expansion joint 100 refer to specification document annexure a. , rubber expansion joint 150 refer to specification document annexure a. , rubber expansion joint 200 refer to specification document annexure a. , sitc y strainer 80 refer to specification document annexure a. , sitc y strainer 150 refer to specification document annexure a. , sitc y strainer 200 refer to specification document annexure a. , repairing of fire hydrant valve 80 refer to specification document annexure a. , supply of gun metal hydrant valve refer to specification document annexure a. , testing of first aid hose reel refer to specification document annexure a. , supply of first aid hose refer to specification document annexure a. , hose pipe 63 refer to specification document annexure a. , short gun metal pipe refer to specification document annexure a. , firemans axe refer to specification document annexure a. , testing of two way fire brigade adopter refer to specification document annexure a. , weather proof cabinet box refer to specification document annexure a. , testing of sprinklers refer to specification document annexure a. , bulb sprinklers refer to specification document annexure a. , refilling of abc refer to specification document annexure a. , refilling of chemical refer to specification document annexure a. , refilling of co2 refer to specification document annexure a. , supply of abc refer to specification document annexure a. , supply of chemical refer to specification document annexure a. , supply of co2 cylinder refer to specification document annexure a. , testing of control panel 30 refer to specification document annexure a. , testing of control panel 4 refer to specification document annexure a. , testing of control panel 2 refer to specification document annexure a. , alarm control panel 30 refer to specification document annexure a. , alarm control panel 4 refer to specification document annexure a. , testing of smoke detector refer to specification document annexure a. , supply of smoke detector refer to specification document annexure a. , testing of manual call point refer to specification document annexure a. , supply of manual call point refer to specification document annexure a. , testing hooter refer to specification document annexure a. , sitc fire alarm sounder refer to specification document annexure a. , testing of speaker refer to specification document annexure a. , sitc of pa speaker refer to specification document annexure a. , supply of voice control in amp refer to specification document annexure a. , testing of amp refer to specification document annexure a. , 2 core 1.5 refer to specification document annexure a. total quantity : 1...

Indian Institute Of Science Education And Research - Punjab

28982193 p / f of aspirating smoke detection system in substations 1 and 2 p / f of aspirating smoke detection system in substations 1 and 2 , supply / installation / testing / commissioning of short wave length laser based absolute smoke detection panel with 2 pipe inlets, upto 800 m2 coverage including false floor and false ceiling; wide sensitivity range 0.005%–20% obs / m; built inalarm levels; high efficiency aspirator; clean air barrier optics protection; easy to replace dual stage filter with built in memory; 7 nos. ofinbuilt potential free relay outputs; supports linear pipe length of 70m per pipe ( total 140m ) or branched pipe up to 100m per pipe;supports 20 nos. of class a sampling points, auto learn for automatic setup of alarm threshold, referencing &event log; tcp / ip & two core wire network connectivity built in for central monitoring & monitoring through centralized software ( software license separate ) approvals ul, ulc, fm make: wagner / edwards / siemens , supply and erection of vesda power supply. the power supply is providing operating power 24 to 27 volt, including battery backup, for the entire line of vesda aspirating smoke detectors. the vesda power supply has been designed to power a single unit to multiple units depending on application needs. it provides 24 to 27 volt operating power to the vesda system as well as a battery charger function that supervises and maintains the standby batteries. relay outputs for connection to the general purpose input for fault monitoring ( 230 vac only ) en54 4 compatible, temperature compensated charging to maximize battery life. the job includes the cost of labour and other petty material required to complete the job to the entire satisfaction of engineer in charge of the work.make: wagner / edwards / siemens , supply and laying ofupvc ( unplasticised polyvinyl chloride ) pipe 25 mm outer dia ofmake astral / finolex / supreme. the pipe should have pressure of 33.7 kg / cm2 at 23° c. the pipe should be laid on the ceiling of the building with the help of suitable size of clamp. the job includes the cost of labour and other petty material required to complete the job to the entire satisfaction of engineer in charge of the work. , supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required. , 3 x 1.5 sq. mm , supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. , 25 mm , supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required....

Ministry Of Defence - Punjab

28282412 bids are invited forelectronic hooter , smoke detector , wireless fire alarm system , pvc aluminium cable as per is;694 total quantity : 412...

Bharat Sanchar Nigam Limited - Punjab

27788938 operation and comprehensive maintenance of ems for te bldg at rayya jandiala guru majitha ajnala and comprehensive maintenance of ems for various rented buildings and group exchanges under sdca goindwal rayya jandiala guru majitha ajnala sh clear , wet servicing of existing 1 . 5tr/2tr window/split ac unit i/c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i/c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split/wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing/flaring the leak points , vacumising , purging and making the system leak proof i/c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5/2 . 0 tr , replacement of following capacity of existing old defective compressor with new sealed compressor i/c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition/alteration i/c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i/c testing etc as reqd . ( m/s emerson/tecumseh/ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new/oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac/sac units i/c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( 80/100 mfd ) ( m/s epcos/asian/ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( m/s epcos/asian/ss make ) , repairing of control card pcb existing 1 . 5/2 . 0tr split ac units , condenser fan blade ( pvc/frp ) , condensor coil , replacement of control card pcb suitable for 1 . 5tr split ac units , blower fan motor for idu of split ac unit ( m/s aue/marathon ge/national/ diamond /ss make ) , thermostat ( m/s danfoss/indfoss/arvind/ss make , washable nylon air filter , replacement/rewinding of existing condenser motor of 1 . 5/2 tr split/window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , sitc of photo electric type smoke detector complete with detector base etc as reqd and as per bsnl specifications , sitc of electro pneumatic type dual action ( heat cum rate of rise in temperature ) heat detector complete with detector base etc as reqd and as per bsnl specifications . , providing repairs to the existing microprocessor based fire detection and fire alarm panel i/c replacement of transformer , control cards , pcb i/c making minor repairs to make the panel fully functional as per the directions of the engineer in charge . , replacement of following ampere hour capacity sealed maintenance free battery i/c making connections , testing and commissioning etc comp . as reqd complete with dismantling of old defective batteries . ( note:the old dismantled battery shall be the property of the agency . ) , 12v 7ah , 12v 26ah , refilling of existing 4 . 5 kg co2 in the existing 4 . 5 kg co2 type cylinder including transportation to the filling facility and back to concerned te bldg . including testing and commissioning complete etc as required . , supplying and fixing following items in the existing 4 . 5 kg co2 fire extinguishers i/c testing and commissioning etc as reqd . , horns with hose pipe , topping up of transformer oil with dielectric strength more than 40 kv in the existing transformer/ ocb etc . comp . as reqd . , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders/ change over switch in existing cubicle panel board including drilling holes in the cubicle panel making connections etc comp . as reqd . , 200/250 a , 65 ka , fpmccb , 250 amp . fp change over switch , providing and fixing following components in the existing capacitor panel suitable i/c making connections , testing and commissioning etc comp . as reqd . , 5kvar heavy duty cylindrical capacitor suitable for linear load , 10kvar heavy duty cylindrical capacitor suitable for linear load , plugging the leakage of the existing 200 kva transformer by providing suitable size of gasket etc . complete as per requirement at site . ...

Military Engineer Services - Punjab

27735274 repair and maintenance of certain fire alarm system spyder at af stn pathankot , complete testing of fire alram system i . e . senser , panel electric smoke detector , response indicator , heat detector , manual call box , electronic hooter , soilid state main control panel , 12 v 7 ah dry battery for the spyder i , ii & iii area and replacement as required defected follwing items including testing complete qty 03 jobs ( a ) smoke detector qty 40 nos ( b ) hooter 03 nos ( c ) battery 12v , 7 ah complete 10 nos ( d ) mannual call point 03 nos ( e ) fire alarm control panel 03 nos ( f ) fire alarm control panel programming 02 nos...

Thapar University - Punjab

27715602 request for quotation(s) for the fire alarm system and fire extinguishers in acird lab 1 sitc of ul listed conventional fire alarm 4 zone as per specifications complete with instalation fixing and testing with required material and module per loop, all as per specification make agani/system sensor/apollo 2 sitc of ul listed conventional sounder cum flesher complete with mounting box make agani/life safety/ 3 sitc mcp manuual call point, with response indicator. agani/life safety 4 sitc of twisted pair, 2 core 1.5 sq mm pvc, copper cable for connection for connection to fire detectors, call points and hooters in series including making the connection with necessary make. glads havells, ecko, polycab 5 sitc smoke detectors with all acessories and required wiring as per standerds. agani/life safety 6 p.v.c pipe condute used for cable for wiring of alarm system 25mm dia with flex bends and other material. polyplast/jindal heavy gauge 7 errection charges for detector ,fire alarm system and connection cable 8 fire extinguisher cap 4 kg (life safety/fire stop/classic agni) 9 supply and fixing of co2 4.5 kg fire extinguisher (life safety/fire stop/classic agni) ...

Bharat Sanchar Nigam Limited - Punjab

27646332 operation and comprehensive maintenance of ems for te bldg at rayya jandiala guru majitha ajnala an comprehensive maintenance of ems for various rented buildings and group exchanges under sdca goindwa rayya jandiala guru majitha and ajnala sh clea , wet servicing of existing 1 . 5tr/2tr window/split ac unit i/c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i/c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split/wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing/flaring the leak points , vacumising , purging and making the system leak proof i/c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5/2 . 0 tr , replacement of following capacity of existing old defective compressor with new sealed compressor i/c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition/alteration i/c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i/c testing etc as reqd . ( m/s emerson/tecumseh/ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new/oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac/sac units i/c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( 80/100 mfd ) ( m/s epcos/asian/ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( m/s epcos/asian/ss make ) , repairing of control card pcb existing 1 . 5/2 . 0tr split ac units , condenser fan blade ( pvc/frp ) , condensor coil , replacement of control card pcb suitable for 1 . 5tr split ac units , blower fan motor for idu of split ac unit ( m/s aue/marathon ge/national/ diamond /ss make ) , thermostat ( m/s danfoss/indfoss/arvind/ss make , washable nylon air filter , replacement/rewinding of existing condenser motor of 1 . 5/2 tr split/window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , sitc of photo electric type smoke detector complete with detector base etc as reqd and as per bsnl specifications , sitc of electro pneumatic type dual action ( heat cum rate of rise in temperature ) heat detector complete with detector base etc as reqd and as per bsnl specifications . , providing repairs to the existing microprocessor based fire detection and fire alarm panel i/c replacement of transformer , control cards , pcb i/c making minor repairs to make the panel fully functional as per the directions of the engineer in charge . , replacement of following ampere hour capacity sealed maintenance free battery i/c making connections , testing and commissioning etc comp . as reqd complete with dismantling of old defective batteries . ( note:the old dismantled battery shall be the property of the agency . ) , 12v 7ah , 12v 26ah , refilling of existing 4 . 5 kg co2 in the existing 4 . 5 kg co2 type cylinder including transportation to the filling facility and back to concerned te bldg . including testing and commissioning complete etc as required . , supplying and fixing following items in the existing 4 . 5 kg co2 fire extinguishers i/c testing and commissioning etc as reqd . , horns with hose pipe , topping up of transformer oil with dielectric strength more than 40 kv in the existing transformer/ ocb etc . comp . as reqd . , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders/ change over switch in existing cubicle panel board including drilling holes in the cubicle panel making connections etc comp . as reqd . , 200/250 a , 65 ka , fpmccb , 250 amp . fp change over switch , providing and fixing following components in the existing capacitor panel suitable i/c making connections , testing and commissioning etc comp . as reqd . , 5kvar heavy duty cylindrical capacitor suitable for linear load , 10kvar heavy duty cylindrical capacitor suitable for linear load , plugging the leakage of the existing 200 kva transformer by providing suitable size of gasket etc . complete as per requirement at site . ...

National Fertilizers Limited - Punjab

27547605 procurement of fire detection and alarm system st/2020/69/1 procurement of fire detection and alarm system , microprocessor based addressable main fire alarm control panel facp 1 with 2 loops located at mrss substation ( urea ) with alarm indication of all zones ( facp 1 & facp 2 ) , with its own battery and battery charger . , microprocessor based addressable fire alarm control panel facp 2 with 2 loops located at old ammonia substation with alarm indication of all zones ( facp 1 & facp 2 ) with its own battery and battery charger , microprocessor based central monitoring station repeater control panel ( rcp ) located in the nfl fire station with alarm indication of all zones and detectors/devices ( facp 1 & facp 2 ) with its own battery and battery charger , a master system laptop with printer ( workstation ) for controlling / programming of fire alarm control panel ( facp 2 ) , repeater control panel ( rcp ) and main fire alarm panel ( facp 1 ) . , non addressable manual call points , non addressable is ( intrinsically safe ) manual call points for hazardous area ( gas group iia/iib ) , non addressable smoke detectors / heat detectors as per site requirement , non addressable is ( intrinsically safe ) smoke detectors / heat detectors for hazardous area ( gas group iia/iib ) as per site requirement , non addressable electronic hooters/sounders , non addressable beacon/flashers , control cables 1 . 1 kv grade to is: 1554 , overall frls sheath , screened armoured & twisted size: 2c x 1 . 5 mm 2 . , redundant optical cables between fire panels and repeater panel with ring topology , smoke detector/ heat detector removal and test toolkit , supply of mandatory recommended accessories / any other item not listed in the bom but required for the functioning of the system must also be quoted separately . , installation , testing and commissioning charges if any , lumsum amc charges for two years after expiry of guarantee period...

Diesel Loco Modernization Works - Punjab

27424743 supply of set of non metallic pipeset of non metallic pipe, set of non metallic pipe ( smoke detector pipe ) to set list no. el29230020. specifications:clw / es / 3 / 0254 / c....

Bharat Sanchar Nigam Limited - Punjab

27222052 operation comprehensive maintenance of ems for t e bldg at rayya jandiala guru majitha ajnala comprehensive maintenance of ems for various rented buildings group exchanges under sdca goindwal rayya jandiala guru majitha aajnala . shclearingofdefect operation comprehensive maintenance of ems for t e bldg at rayya jandiala guru majitha ajnala comprehensive maintenance of ems for various rented buildings group exchanges under sdca goindwal rayya jandiala guru majitha a ajnalashclearingofdefect , wet servicing of existing 1 . 5tr/2tr window/split ac unit i/c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i/c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split/wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing/flaring the leak points , vacumising , purging and making the system leak proof i/c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5/2 . 0 tr , replacement of following capacity of existing old defective compressor with new sealed compressor i/c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition/alteration i/c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i/c testing etc as reqd . ( m/s emerson/tecumseh/ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new/oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac/sac units i/c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( 80/100 mfd ) ( m/s epcos/asian/ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( m/s epcos/asian/ss make ) , repairing of control card pcb existing 1 . 5/2 . 0tr split ac units , condenser fan blade ( pvc/frp ) , condensor coil , replacement of control card pcb suitable for 1 . 5tr split ac units , blower fan motor for idu of split ac unit ( m/s aue/marathon ge/national/ diamond /ss make ) , thermostat ( m/s danfoss/indfoss/arvind/ss make , washable nylon air filter , replacement/rewinding of existing condenser motor of 1 . 5/2 tr split/window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , sitc of photo electric type smoke detector complete with detector base etc as reqd and as per bsnl specifications , sitc of electro pneumatic type dual action ( heat cum rate of rise in temperature ) heat detector complete with detector base etc as reqd and as per bsnl specifications . , providing repairs to the existing microprocessor based fire detection and fire alarm panel i/c replacement of transformer , control cards , pcb i/c making minor repairs to make the panel fully functional as per the directions of the engineer in charge . , replacement of following ampere hour capacity sealed maintenance free battery i/c making connections , testing and commissioning etc comp . as reqd complete with dismantling of old defective batteries . ( note:the old dismantled battery shall be the property of the agency . ) , 12v 7ah , 12v 26ah , refilling of existing 4 . 5 kg co2 in the existing 4 . 5 kg co2 type cylinder including transportation to the filling facility and back to concerned te bldg . including testing and commissioning complete etc as required . , supplying and fixing following items in the existing 4 . 5 kg co2 fire extinguishers i/c testing and commissioning etc as reqd . , horns with hose pipe , topping up of transformer oil with dielectric strength more than 40 kv in the existing transformer/ ocb etc . comp . as reqd . , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders/ change over switch in existing cubicle panel board including drilling holes in the cubicle panel making connections etc comp . as reqd . , 200/250 a , 65 ka , fpmccb , 250 amp . fp change over switch , providing and fixing following components in the existing capacitor panel suitable i/c making connections , testing and commissioning etc comp . as reqd . , 5kvar heavy duty cylindrical capacitor suitable for linear load , 10kvar heavy duty cylindrical capacitor suitable for linear load , plugging the leakage of the existing 200 kva transformer by providing suitable size of gasket etc . complete as per requirement at site . ...

Diesel Loco Modernization Works - Punjab

27206823 supply of set of non metallic pipeset of non metallic pipe ( smoke detector pipe ) to set list no. el29230020. specifications:clw / es / 3 / 0254 / c....

Bharat Sanchar Nigam Limited - Punjab

27073593 operation comprehensive maintenance of ems for te bldg at rayya jandiala guru majitha ajnala comprehensive maintenance of ems for various rented buildings group exchanges under sdca goindwa rayya jandiala guru majitha ajnala sh cleari , wet servicing of existing 1 . 5tr/2tr window/split ac unit i/c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i/c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split/wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing/flaring the leak points , vacumising , purging and making the system leak proof i/c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5/2 . 0 tr , replacement of following capacity of existing old defective compressor with new sealed compressor i/c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition/alteration i/c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i/c testing etc as reqd . ( m/s emerson/tecumseh/ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new/oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac/sac units i/c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( 80/100 mfd ) ( m/s epcos/asian/ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5/2 . 0 tr ( m/s epcos/asian/ss make ) , repairing of control card pcb existing 1 . 5/2 . 0tr split ac units , condenser fan blade ( pvc/frp ) , condensor coil , replacement of control card pcb suitable for 1 . 5tr split ac units , blower fan motor for idu of split ac unit ( m/s aue/marathon ge/national/ diamond /ss make ) , thermostat ( m/s danfoss/indfoss/arvind/ss make , washable nylon air filter , replacement/rewinding of existing condenser motor of 1 . 5/2 tr split/window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , sitc of photo electric type smoke detector complete with detector base etc as reqd and as per bsnl specifications , sitc of electro pneumatic type dual action ( heat cum rate of rise in temperature ) heat detector complete with detector base etc as reqd and as per bsnl specifications . , providing repairs to the existing microprocessor based fire detection and fire alarm panel i/c replacement of transformer , control cards , pcb i/c making minor repairs to make the panel fully functional as per the directions of the engineer in charge . , replacement of following ampere hour capacity sealed maintenance free battery i/c making connections , testing and commissioning etc comp . as reqd complete with dismantling of old defective batteries . ( note:the old dismantled battery shall be the property of the agency . ) , 12v 7ah , 12v 26ah , refilling of existing 4 . 5 kg co2 in the existing 4 . 5 kg co2 type cylinder including transportation to the filling facility and back to concerned te bldg . including testing and commissioning complete etc as required . , supplying and fixing following items in the existing 4 . 5 kg co2 fire extinguishers i/c testing and commissioning etc as reqd . , horns with hose pipe , topping up of transformer oil with dielectric strength more than 40 kv in the existing transformer/ ocb etc . comp . as reqd . , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders/ change over switch in existing cubicle panel board including drilling holes in the cubicle panel making connections etc comp . as reqd . , 200/250 a , 65 ka , fpmccb , 250 amp . fp change over switch , providing and fixing following components in the existing capacitor panel suitable i/c making connections , testing and commissioning etc comp . as reqd . , 5kvar heavy duty cylindrical capacitor suitable for linear load , 10kvar heavy duty cylindrical capacitor suitable for linear load , plugging the leakage of the existing 200 kva transformer by providing suitable size of gasket etc . complete as per requirement at site . ...

Bharat Sanchar Nigam Limited - Punjab

26873581 operation comprehensive maintenance of ems for te bldg at rayya jandiala guru majitha ajnala comprehensive maintenance of ems for various rented buildings group exchanges under sdca goindwa rayya jandiala guru majitha ajnala sh cleari , wet servicing of existing 1 . 5tr / 2tr window / split ac unit i / c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i / c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split / wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing / flaring the leak points , vacumising , purging and making the system leak proof i / c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5 / 2 . 0 tr , replacement of following capacity of existing old defective compressor with new sealed compressor i / c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition / alteration i / c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i / c testing etc as reqd . ( m / s emerson / tecumseh / ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new / oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac / sac units i / c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5 / 2 . 0 tr ( 80 / 100 mfd ) ( m / s epcos / asian / ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5 / 2 . 0 tr ( m / s epcos / asian / ss make ) , repairing of control card pcb existing 1 . 5 / 2 . 0tr split ac units , condenser fan blade ( pvc / frp ) , condensor coil , replacement of control card pcb suitable for 1 . 5tr split ac units , blower fan motor for idu of split ac unit ( m / s aue / marathon ge / national / diamond / ss make ) , thermostat ( m / s danfoss / indfoss / arvind / ss make , washable nylon air filter , replacement / rewinding of existing condenser motor of 1 . 5 / 2 tr split / window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , sitc of photo electric type smoke detector complete with detector base etc as reqd and as per bsnl specifications , sitc of electro pneumatic type dual action ( heat cum rate of rise in temperature ) heat detector complete with detector base etc as reqd and as per bsnl specifications . , providing repairs to the existing microprocessor based fire detection and fire alarm panel i / c replacement of transformer , control cards , pcb i / c making minor repairs to make the panel fully functional as per the directions of the engineer in charge . , replacement of following ampere hour capacity sealed maintenance free battery i / c making connections , testing and commissioning etc comp . as reqd complete with dismantling of old defective batteries . ( note:the old dismantled battery shall be the property of the agency . ) , 12v 7ah , 12v 26ah , refilling of existing 4 . 5 kg co2 in the existing 4 . 5 kg co2 type cylinder including transportation to the filling facility and back to concerned te bldg . including testing and commissioning complete etc as required . , supplying and fixing following items in the existing 4 . 5 kg co2 fire extinguishers i / c testing and commissioning etc as reqd . , horns with hose pipe , topping up of transformer oil with dielectric strength more than 40 kv in the existing transformer / ocb etc . comp . as reqd . , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders / change over switch in existing cubicle panel board including drilling holes in the cubicle panel making connections etc comp . as reqd . , 200 / 250 a , 65 ka , fpmccb , 250 amp . fp change over switch , providing and fixing following components in the existing capacitor panel suitable i / c making connections , testing and commissioning etc comp . as reqd . , 5kvar heavy duty cylindrical capacitor suitable for linear load , 10kvar heavy duty cylindrical capacitor suitable for linear load , plugging the leakage of the existing 200 kva transformer by providing suitable size of gasket etc . complete as per requirement at site ....

Bharat Sanchar Nigam Limited - Punjab

26254258 operation and comprehensive maintenance of ems for t e bldg at rayya jandiala guru majitha ajnala and comprehensive maintenance of ems for various rented buildings and group exchanges under sdca goindwal rayya jandiala guru majitha , ajnala risk cost , wet servicing of existing 1 . 5tr / 2tr window / split ac unit i / c removing , cleaning all components and filters , dedusting by high pressure air blower , washing condenser , evaporator i / c chemical cleaning ( if required ) , refixing , tightening electrical connections , testing of ac unit , recording all parameters in service report etc as reqd . , providing and charging of r 22 refrigerant gas including carrying out leak testing of 1 . 5tr split / wac ac units with nitrogen gas including dismantling of machine , flushing the system , brazing / flaring the leak points , vacumising , purging and making the system leak proof i / c transportation of nitrogen cylinder , brazing kit & vacuum pump , supplying & charging of r22 refrigerant gas at site , reinstallation , testing & commissioning complete etc as required . , 1 . 5 / 2 . 0 tr , replacement of following capacity of existing old defective compressor with new sealed compressor i / c dismantling of faulty compressor , cutting refrigerant piping , brazing & making necessary addition / alteration i / c proper mounting on base plate , connection of suction and discharge lines , leak test & charging refrigerant i / c testing etc as reqd . ( m / s emerson / tecumseh / ss make ) ( note the firm shall submit test certificate or documentary proof towards purchase of new / oem factory repaired compressor . ) the defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory ) , 1 . 5 tr , replacement of following material for repairing & attending break down complaints of 1 . 5 tr wac / sac units i / c dismantling , connection , fixing & testing etc as required . ( note the defective material shall be the property of agency & firm should consider suitable price rebate for the same while quoting . the material under replacement shall be similar to existing defective material or as per product directory . , starting capacitor ( metal body ) of rating suitable for 1 . 5 / 2 . 0 tr ( 80 / 100 mfd ) ( m / s epcos / asian / ss make ) , running capacitor ( metal body ) of rating suitable for 1 . 5 / 2 . 0 tr ( m / s epcos / asian / ss make ) , repairing of control card pcb existing 1 . 5 / 2 . 0tr split ac units , condenser fan blade ( pvc / frp ) , condensor coil , replacement of control card pcb suitable for 1 . 5tr split ac units , blower fan motor for idu of split ac unit ( m / s aue / marathon ge / national / diamond / ss make ) , thermostat ( m / s danfoss / indfoss / arvind / ss make , washable nylon air filter , replacement / rewinding of existing condenser motor of 1 . 5 / 2 tr split / window ac unit from workshop complete with reinstallation , testing etc as required , 3 core flexible copper cable 2 . 5 sq mm , sitc of photo electric type smoke detector complete with detector base etc as reqd and as per bsnl specifications , sitc of electro pneumatic type dual action ( heat cum rate of rise in temperature ) heat detector complete with detector base etc as reqd and as per bsnl specifications . , providing repairs to the existing microprocessor based fire detection and fire alarm panel i / c replacement of transformer , control cards , pcb i / c making minor repairs to make the panel fully functional as per the directions of the engineer in charge . , replacement of following ampere hour capacity sealed maintenance free battery i / c making connections , testing and commissioning etc comp . as reqd complete with dismantling of old defective batteries . ( note:the old dismantled battery shall be the property of the agency . ) , 12v 7ah , 12v 26ah , refilling of existing 4 . 5 kg co2 in the existing 4 . 5 kg co2 type cylinder including transportation to the filling facility and back to concerned te bldg . including testing and commissioning complete etc as required . , supplying and fixing following items in the existing 4 . 5 kg co2 fire extinguishers i / c testing and commissioning etc as reqd . , horns with hose pipe , topping up of transformer oil with dielectric strength more than 40 kv in the existing transformer / ocb etc . comp . as reqd . , providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders / change over switch in existing cubicle panel board including drilling holes in the cubicle panel making connections etc comp . as reqd . , 200 / 250 a , 65 ka , fpmccb , 250 amp . fp change over switch , providing and fixing following components in the existing capacitor panel suitable i / c making connections , testing and commissioning etc comp . as reqd . , 5kvar heavy duty cylindrical capacitor suitable for linear load , 10kvar heavy duty cylindrical capacitor suitable for linear load , plugging the leakage of the existing 200 kva transformer by providing suitable size of gasket etc . complete as per requirement at site ....

Military Engineer Services - Punjab

25894132 repair of fire alarm system at ee hall motitibba and ee hall dainkund at air force station dalhousie under ge ( af ) pathankot , ( i ) editing and testing of fire alarm control panel programming qty 02 nos ( ii ) testing of smoke detector qty 40 nos ( iii ) testing of heat detectors qty 05 nos ( iv ) testing of multi type detectors qty 11 nos ( v ) addressable new smoke detector qty 08 nos ( vi ) 12 v , 7 ah batteries qty 04 nos...

National Fertilizers Limited - Punjab

25117157 supply of fire detection and alarm system , microprocessor based conventional semi addressable system with main fire alarm control cum repeater panel located at mrss substation ( urea ) with individual 32 zones + 32 zones repeated , total 64 zones , with its own battery and battery charger , fire alarm control panel facp 1 at old ammonia substation with 16 zones with its own battery and battery charger , fire alarm control panel facp 2 at nue substation with 16 zones with its own battery and battery charger , a master system laptop with printer ( workstation ) for controlling / programming of fire alarm control panels , repeater panel and main fire alarm panel . , central monitoring station ( repeater panel ) located in the nfl fire station ( total 64 zones ) with its own battery and battery charger , non addressable manual call points , non addressable smoke detectors , non addressable heat detectors , non addressable electronic hooters / sounders , non addressable beacon / flashers , control cables 1 . 1 kv grade to is: 1554 , overall frls sheath , screened armoured & twisted size: 2c x 1 . 5 mm 2 . , 2x 100% redundant optical communication cables from all fire panels to main fire alarm panel and repeater panel at fire station building . ( 2x2 km ) , smoke detector / heat detector removal and test toolkit , splicing toolkit and fault locator toolkit for optical cable communication , essential spares: 20% spare detectors , manual call points , spare loop complete with loop cards and all other accessories so that the system can be expanded in future by purchaser . further at least 10% of loop capacity shall be left free in each of the connected loop in all the panels , so that , additional devices may be connected to the system in any of the loop by purchaser in future . , any other item not listed in the bom but required for the functioning of the system must also be quoted separately , installation , testing and commissioning charges if any , lumsum amc charges for two years after expiry of warranty period...

Bharat Sanchar Nigam Limited - Punjab

24753585 operation comprehensive maintenance of ac units and afd fa system at te bldg . bharat nagar chowk ludhiana . sh repairing of package units at risk and cost of ms wattz power control ludhiana , providing and replacing the scroll compressor suitable for 7tr high precession package type air conditioner units . i/c dismantling the existing defective compressor fixing the new , jointing/ brazing the same etc as required . . ( make emerson , model zr108 or similar superior make ) , providing and replacing new hermatically sealed reiprocating compressor in the indoor unit of existing package ac unit i/c making modifications required to suit the installation of new compressor in the existing package ac i/c making connections with existing refrigerant pipings , suitable for operation on 3 phase 415 volts , 50 hz ac supply i/c making connections , testing and commissioning etc comp . as reqd . ( make kirloskar kcr 57/emerson/similar superior make ) . , providing and carrying out nitrogen pressure testing , leak testing , evacuation of the entire refrigerant cirucit of existing package ac unit i/c pressure testing with nitrogen , leak testing with hallide torch and soap solution , attending the leakage if any , vacumising etc comp . as per the directions of engineer in charge . the entire tests to be carried out in this item shall be carried out as per standard proceedure so as to ensure that there is no leakage in the refrigerant circuit before charging of refrigerant . , providing and top up of refrigerant r 407c in package type air conditioner units and prior to top up evacution test to detect for any minor/mazor leakage must be carried out in the presence of engineer in charge i/c testing and commissioning etc as required , supplying and charging refrigerant r 22 in the refrigerant cirucit of existing package ac units as per the standard proceedures and as per the directions of engineer in charge comp . as reqd . , rewinding of condenser fan motor of outdoor unit of package type ac unit i/c change of bushes etc i/c dismentling and fixing etc . complete as reqd . , rewinding of blower fan motor of indoordoor unit of package type ac unit i/c change of bushes etc i/c dismentling and fixing etc . complete as reqd . , providing and fixing liquid line filter drier with hand shut off valves and flare nuts in the existing refrigerant line i/c dismantling the old choked drier and fixing the new one . ( note: the old faulty drier and hand shut off valves shall be the property of the agency . the rates should be quoted accordingly ) . , providing and fixing following items in the existing 7tr package ac units i/c making connections with the existing refrigerant circuit etc comp . as reqd . , ( a ) dial type discharge pressure gauge ( 0 500 psi ) , ( b ) dial type suction pressure gauge ( 0 300 psi ) , replacement of the following faulty components in existing 7tr package type air conditioner i/c dismantling of old faulty component & fixing of new one and testing commissiong etc as reqd , ( i ) repair/replacement of control card of 7tr ac package unit , ( ii ) minilec vsp d2 spp , ( iii ) 63 amp four pole mcb , 440 volts , ( iv ) lp and hp switch , ( v ) expension valve , repairing / replacement of following defective components in existing conventional type fire panel and and local control panel of automatic fire detection and alarm system including dismantalling the old defective parts and fixing of new ones interconnections , testing complete etc as required . , zone card , power supply card , hooters 12v/24v , response indicator ( 2 led type ) , replacement of existing faulty / unservicable 12v , 26ah capacitie sealed dry maintenance free battery complete etc . as required . ( make: bsnl approved make ) , repairing of existing faulty pcb/main control card in the existing microprocessor based main control panel /local control panel including checking of wiring/interconnection/minor repairs ( if any ) to make the panels in healthy/operational conditions complete as per site requirement . , repairing of existing public address system ( pa system ) i/c testing with mike , amplifier , interconnections complete etc as required . , supplying , installation , testing and commissioning of photo electric smoke detector with a detector junction box . the detector should incorporate solid state led and high speed , high sensing photo diode within sensing chamber including other accessories etc . as required as per makes and specifications attached i/c dismantling the existing detectors wherever required . the base shall be of the same make as that of detector . ( make: bsnl approved make ) , supply , installation , fixing , testing and commissioning of fixed temperature cum rate of rise heat detectors with thermistor as temperature sensing element as per makes and specifications attached . i/c dismantelling the existing detectors wherever required ( make: bsnl approved make ) ...

Rail Coach Factory - Punjab

23839463 supply of , smoke detector unit for lhb eog coachesas per drawing/spec. edts087, rev b,corr 1...

Punjab State Transmission Corporation Limited - Punjab

23056463 quotation for refilling/inspection of fire fighting equipment installed at sldc, building, ablowal patiala 1 refilling of fire fighting i) co‐2 type fire extinguisher 4.5 kg.cyl. ii) co‐2 type fire extinguisher 2.5 kg.cyl. v) water type fire extinguisher(9l) vi) abc type fire extinguisher(multipurpose dry powder) v) inspection & testing charges of fire fighting system at sldc building, ablowal (panel alarm, smoke detectors etc )...

Rail Coach Factory - Punjab

20894600 tender for smoke detector unit for lhb eog coachesitem list : (1) smoke detector unit for lhb eog coachesas per edts087, rev b,corr 1...

Department Of Industries And Commerce - Punjab

20097143 quotations for repair and annual maintenance contract (amc) – comprehensive for fire alarm system installed at punjab infotech. 01 1. alarm panel 2. smoke detectors 3. hooters with flesher 4. manual call points 5. battery (in working condition)...

Bharat Sanchar Nigam Limited - Punjab

20020176 supply, installation, testing and commissioning of ventilation box in existing bts shelter for various sites under ssa pathankot.(2nd call) 1 engine 2 alternator(brushless) 3 battery (lead acid / mntc. free) 4 hv switchgear (vacuum circuit breaker/sf6 ) 5 transformer (oil filled / dry type) a) above 400 kva b) up to 400 kva 6 air circuit breaker 7 mccb(ics=icu) 8 sdf units 9 power contactors 10 change over switch 11 intelligent apfc relay 12 bus bar trunking/ sandwiched bus duct 13 power capacitors (mpp/app) 14 digital/ kwhr meter 15 cold shrink ht/lt cable joint 16 rubber matting 17 mcb/ lsolator /elcb/rccb/ distribution board 18 ms/ pvc conduit 19 cable tray 20 ht/lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump 24 motors 25 fresh air fans 26 starter 27 single phase preventer 28 gi/ms pipe 29 foot valve 30 gate valve 31 compressors 32 resin bonded glass wool 33 expanded polystyrene 34 gauge 35 controls 36 fine filters 37 gi sheet 38 heat detector 39 ionization detector 40 photo electric smoke detector 41 fire panel (microprocessor based) 42 sprinkler/ hose reel & hose pipe 43 fire extinguisher 44 lift 45 precision ac packages 7 tr....

Bharat Sanchar Nigam Limited - Punjab

19960392 tender for providing ems for dr site of (gsat 29)isro at rttc rajpura 1 engine 2 alternator(brushless 3 battery (lead acid mntc. free) 4 hv switchgear (vacuum circuit breaker/sf6 ) 5 transformer (oil filled type) 6 air circuit breaker 7 mccb(ics=icu) 8 sdf units 9 power contactors 10 change over switch 11 intelligent apfc relay 12 bus bar trunking/ sandwiched bus duct 13 power capacitors (mpp/app) 14 digital/ kwhr meter 15 cold shrink ht/lt cable joint 16 rubber matting 17 mcb/ lsolator /elcb/rccb/ distribution board 18 ms/ pvc conduit 19 cable tray 20 ht/lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump 24 motors 25 fresh air fans 26 starter 27 single phase preventer 28 gi/ms pipe 29 foot valve 30 gate valve advance/ fountain 31 compressors carrier/ 32 resin bonded glass wool fibre 33 expanded polystyrene basf( 34 gauge feibig 35 controls flica ranutrol 36 fine filters anfiltra puromatic/ 37 gi sheet hsu 38 heat detector appollo /system 39 ionization detector appollo system 40 photo electric smoke detector appollo wormald 41 fire panel (microprocessor based) agni sensor 42 sprinkler/ hose reel & hose pipe isi 43 fire extinguisher isi 44 lift...

Bharat Sanchar Nigam Limited - Punjab

19943609 enquiry for attending the faults of power factor panel, afad system & main supply failure fault in ht connection te buildings under ssa jalandhar.. 1 engine 2 alternator(brushless) 3 battery (lead acid / mntc. free) 4 hv switchgear (vacuum circuitbreaker/ ) 5 transformer (oil filled / dry type) a) above 400 kva b) up to 400 kva 6 air circuit breaker 7 mccb(ics=icu) 8 sdf units 9 power contactors 10 change over switch 11 intelligent apfc relay 12 bus bar trunking/ sandwiched bus duct 13 power capacitors (mpp/app) 14 digital/ kwhr meter 15 cold shrink ht/lt cable joint 16 rubber matting 17 mcb/ lsolator /elcb/rccb/ distribution board 18 ms/ pvc conduit 19 cable tray 20 ht/lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump 24 motors 25 fresh air fans 26 starter 27 single phase preventer 28 gi/ms pipe 29 foot valve 30 gate valve 31 compressors 32 resin bonded glass wool 33 expanded polystyrene 34 gauge 35 controls 36 fine filters 37 gi sheet 38 heat detector 39 ionization detector 40 photo electric smoke detector 41 fire panel (microprocessor based) 42 sprinkler/ hose reel & hose pipe 43 fire extinguisher 44 lift 45 high precision air conditioners (hpac units)...

Bharat Sanchar Nigam Limited - Punjab

19924566 tender for providing ems for nfs site (pkg ii) at er i site, air force station barnala. engine ,alternator(brushless ,battery (lead acid / mntc. free) ,hv switchgear (vacuum circuit breaker/sf6 ) ,transformer (oil filled type) ,air circuit breaker ,mccb(ics=icu) ,sdf units ,power contactors ,change over switch ,intelligent apfc relay, bus bar trunking/ sandwiched bus duct ,power capacitors (mpp/app) ,digital/ kwhr meter ,cold shrink ht/lt cable joint ,rubber matting ,mcb/ lsolator /elcb/rccb/ distribution board ,ms/ pvc conduit ,cable tray, ht/lt cables ,pvc insulated copper conductor wire ,centrifugal pump, submersible pump ,motors ,fresh air fans ,starter ,single phase preventer ,gi/ms pipe ,foot valve ,gate valve ,compressors ,resin bonded glass wool, expanded polystyrene ,gauge ,controls ,fine filters ,gi sheet, ,heat detector ,ionization detector ,photo electric smoke detector ,fire panel (microprocessor based) ,sprinkler/ hose reel & hose pipe ,fire extinguisher ,lift...

Bharat Sanchar Nigam Limited - Punjab

19829149 tender for dismantling, shifting, installation and commissioning of 40 kva dea set from te shehzadi to te gidderbaha and 82.5 kva dea set from te talwandi bhai to te mukatsar.. 1 engine 2 alternator(brushless) 3 battery (lead acid / mntc. free) 4 hv switchgear (vacuum circuit breaker/sf6 ) 5 transformer (oil filled / dry type) a) above 670 kva b) up to 670 kva 6 air circuit breaker 7 mccb(ics=icu) 8 sdf units 9 power contactors 10 change over switch 11 intelligent apfc relay 12 bus bar trunking/ sandwiched bus duct 13 power capacitors (mpp/app) 14 digital/ kwhr meter 15 cold shrink ht/lt cable joint 16 rubber matting 17 mcb/ lsolator /elcb/rccb/ distribution board 18 ms/ pvc conduit 19 cable tray 20 ht/lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump 24 motors 25 fresh air fans 26 starter 27 single phase preventer 28 gi/ms pipe 29 foot valve 30 gate valve 31 compressors 32 resin bonded glass wool 33 expanded polystyrene 34 gauge 35 controls 36 fine filters 37 gi sheet 38 heat detector 39 ionization detector 40 photo electric smoke detector 41 fire panel (microprocessor based) 42 sprinkler/ hose reel & hose pipe 43 fire extinguisher 44 lift 45 precision ac packages 7 tr...

Bharat Sanchar Nigam Limited - Punjab

19555781 tender for providing electro mechanical services for nfs site (pkg ii) at air force station at rajpura. ( sh: miscellaneous electrical items ) 1 engine 2 alternator(brushless) 3 battery (lead acid /mntc. free) 4 hv switchgear (vacuum circuit breaker/sf6 ) 5 transformer (oil filled/ dry type) a) above 400 kva b) up to 400 kva 6 air circuit breaker 7 mccb(ics=icu) 8 sdf units 9 power contactors 10 change over switch11 intelligent apfc relay 12 bus bar trunking/ sandwiched bus duct 13 power capacitors (mpp/app) 14 digital/ kwhr meter 15 cold shrink ht/ltcable joint 16 rubber matting 17 mcb/ lsolator/elcb/ rccb/distribution board 18 ms/ pvc conduit 19 cable tray 20 ht/lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump 24 motors 25 fresh air fans 26 starter 27 single phase preventer28 gi/ms pipe 29 foot valve 30 gate valve 31 compressors 32 resin bonded glasswool (for chillers only) 33 expanded polystyrene 34 gauge 35 controls 36 fine filters 37 gi sheet 38 heat detector 39 ionization detector 40 photo electric smoke detector 41 fire panel(microprocessor based) 42 sprinkler/ hose reel & hose pipe 43 fire extinguisher 44 lift, etc....

Bharat Sanchar Nigam Limited - Punjab

19555398 tender for providing electro mechanical services for nfs site (pkg i) at air force station at rajpura.( sh: miscellaneous electrical items ) 1 engine 2 alternator(brushless) 3 battery (lead acid /mntc. free) 4 hv switchgear (vacuum circuit breaker/sf6 ) 5 transformer (oil filled/ dry type) a) above 400 kva b) up to 400 kva 6 air circuit breaker 7 mccb(ics=icu) 8 sdf units 9 power contactors 10 change over switch 11 intelligent apfc relay 12 bus bar trunking/ sandwiched bus duct 13 power capacitors (mpp/app) 14 digital/ kwhr meter 15 cold shrink ht/ltcable joint 16 rubber matting 17 mcb/ lsolator/elcb/ rccb/distribution board 18 ms/ pvc conduit 19 cable tray 20 ht/lt cables 21 pvc insulated copper conductor wire 22 centrifugal pump 23 submersible pump 24 motors 25 fresh air fans 26 starter 27 single phase preventer28 gi/ms pipe 29 foot valve 30 gate valve 31 compressors 32 resin bonded glasswool (for chillers only) 33 expanded polystyrene 34 gauge 35 controls 36 fine filters 37 gi sheet 38 heat detector 39 ionization detector 40 photo electric smoke detector 41 fire panel(microprocessor based) 42 sprinkler/ hose reel & hose pipe 43 fire extinguisher 44 lift, etc....