Punjab State Transmission Corporation Limited - Punjab
40970824 quotations for horticulture activities for the sub stations under p & m division, sarna for the year fy 20223 24 & 2024 25....
40970824 quotations for horticulture activities for the sub stations under p & m division, sarna for the year fy 20223 24 & 2024 25....
40964022 work of construction of retaining wall at 66kv sub station nangal bhoor (pathankot)....
40938228 tender for work of extension of switch house building at 66 kv sub station, naushera majha singh ( gurdaspur ) ....
40936936 tender for work of extension of switch house building at 66 kv sub station rajasansi (amritsar)....
40936012 supply of materials used for various 7 nos. 220/132 kv sub stations under p&m division pstcl ferozepur: 1 crc urethane (red oxide) (300 ml) 2 crc lectra clean (400 ml) 3 crc 5 56 pro (500 ml) 4 crc 2 26 (500 ml) high tension insulation tape (scapa) (38 mm x 10 mtr.) 5 6 us pro construction foam for vermin proofing (750 ml)...
40919477 construction of all technical civil works for new 66 kv sub station behlolpur ( under op. circle patiala ) ...
40914379 tender for design, manufacture, testing ,supply and delivery (f.o.r destination at any place in punjab )of diferent type of fire fighting equipment for various sub stations in pspcl...
40908436 work of construction of common burnt oil pit for existing 100 mva/160 mva transformers at 220 kv sub station bajakhana...
40897921 tender for works related to 66kv sub stations...
40893037 tender for attend oil leakage of 100 mva 220/66 kv power transformer t 1 at 220 kv sub station botianwala under p&m division, pstcl ferozepur 220 kv sub station botianwala...
40888781 tender for renovation of buildings of bbmb 66 kv and 11 kv sub station at vyas dam site and 33 kv sub station...
40877598 tender for repair of road in s&d store at 132 kv sub station moga 1 providing and laying pcc flooring in yard area at 220 kv s/s botianwala providing and laying pcc flooring in yard area at 220 kv s/s bajakhana providing and laying pcc flooring in yard area at 220 kv s/s mansa...
40860339 tender for construction of all technical civil works for new 66 kv sub station behlolpur (under op. circle patiala)....
40846414 tender for repair of road in s&d store at 132 kv sub station moga 1....
40845997 tender for cleaning & sweeping, of internal roads, open spaces, mtc. & cutting of grassy lawns, open spaces, parks, weeding out grass small bushes etc. from switch yard area, cable trenches, sump well etc., execution of jobs of complaint clerk, pump driver, plumber, carpenter and helpers attend day to day complaints in 220 kv sub station ablowal....
40803243 providing and installation of new 500 kva transformer at sub station it park, nit jalandhar. punjab...
40783792 no. 6 tender for refilling of fire fighting equipments at various sub stations under p&m division, pstcl, wadala granthian 1. co2 22.5kg 2. co2 40kg 3. co2 45kg 4.co2 10kg 5. co2, 9kg 6. dry powder dcp type 10kg 7. dry powder dcp type 5kg 8. refilling of foam trolly 45 ltr 9. refilling of machnical foam trolly 45 ltr 10. refilling of sodha acid foam trolly 9 ltr ...
40782183 tender for repair of 5kv insulation tester (make megger) at 220kv sub station ajitwal and at 220kv sub station jagraon under p&m division, jagraon....
40780956 tender for provision of additional transformer at sub station no.10 in rail coach factory, hussainpur ( kapurthala ) ....
40763572 tender for providing man power for the job of arboriculture/ gardening, cleaning and sweeping activities for the financial year 2023 24 as given below: 3 nos. person for 4 hours daily for following sub stations under p&m division, pstcl ferozepur: a. 1 no. person for 220 kv sub station, kotkaror b. 1 no. person for 220 kv sub station, botianwala c. 1 no. person for 132 kv sub station, mana singh wala...
40762994 tender for providing security services at powergrid moga sub station...
40758799 supply of strengthening of earthing arrangement by replacement of overaged earthing system at various traction sub stations and switching stations in sahnewal amritsar section over firozpur divisionstrengthening of earthing arrangement by replacement of overaged earthing system at various traction sub stations and switching stations in sahnewal amritsar section over firozpur division,...
40705812 tender for renovation of buildings of 33 kv sub station and bbmb 66 kv & 11 kv sub station...
40703348 bids are invited for bhq of 52 bn itbp amritsar mse socket 16 amp , switch 16 amp pt , switch 6 amp pt , socket 6 amp , modular socket 16 amp as per sample , modular switch 16 amp as per sample , modular switch 6 amp as per sample , modular socket 6 amp as per sample , modular sheet 6 way as per sample , modulr sheet 8 way as per sample , modular sheet 2 way as per sample , moular sheet 1 way as per sample , pvc electrical insulation tape roll size 1.8cmx7mx0.125 , angle holder , batten holder , led batten complete fittings 4 foot 18 or 20 watt , led batten complete fittings 2 foot 10 watt , cable thimble aluminum 16 mm , cable thimble aluminum 25mm , cable thimble aluminum 50mm , cable thimble aluminum 70mm , cable thimble aluminum 95mm , generator sub station penal indicator red, yellow, blue , exhaust fan capacitor 1 mfd , exhaust fan capacitor 1.5 mfd , ceiling areoquiet fan b.l.d.c 1200mm sweep size color as per requirement , tube light rod 2pin 38 or 40 watt as per sample , gyser element 2000watt as per sample arm of electrical of non residential buildings at total quantity : 609...
40695072 extension of shb (battery room) at 66 k.v sub station nasrala, hoshiarpur circle....
40680900 tender for construction of 2 nos. sheds and providing interlock tiles along with upgradation of me lab division, jalandhar and extension of shb (battery room) at 66 kv sub station nasrala, hoshiarpur circle...
40680567 tender for 1. miscellaneous civil works to be executed at chief engineer, border zone complex, pspcl, amritsar. 2. miscellaneous civil works to be executed at 66kv sub station dera baba nanak (gurdaspur)...
40677962 tender for minor civil work and carrying out retail civil works at 66 kv sub station...
40672128 tender for cleaning & sweeping ofinternal roads, open spaces, mic & cutting of grassy lawns, open spaces, parks, weeding out grass small bushes etc. from swatch yard area, cable trenches. sump well etc. execution of jobs of complaint clerk, pump driver plumber carpenter and helpers attend day to day complaints in 220 kv sub station ablows...
40668935 for out source of one no scorpio / xylo/mahindra bolero/tuv 300 or equivalent in price for the office of addl, s.e. 400 kv sub station pstcl nakodar...
40664293 tender for outsourcing of operation & comprehensive maintenance of balance electromechanical services at rttc rajpura.; 1 operation & comprehensivemaintenance of followingservicesat te bldg. ocb exchange and gm office at roparas per specificationand details of services ( inventory ) etc. attached 2 e.i. &fans 3 pumps 4 compound lighting 5 sub station 6 declaration by bidder : 1 ) we hereby declare that in quoting the above prices, we have taken into account the entire credit on inputs available under the gst act introduced w.e.f. 1 july 2017 and further extended on more items till date...
40661881 construction of maharaja bhupinder singh punjab sports university at patiala phase ii providing 11 kv sub station 1000kva 1 nos and 1 no. 630kva with interconnection cables to various blocks silent dg set 160kva 128kw...
40656290 maintenance of electrical installation & fans in office building, campus lighting, repair maintenance of dg set, vrv / vrf system, repair maintenance of pump, repair maintenance of of fire alarm system and 315kva sub station in special bureau campus, rauni farm, patiala ( sh: providing electrical & mechanical services fy 2023 24 ) ...
40650413 breakdown, periodical & preventive maintenance of building lighting, street lighting, security lighting and allied equipment like cabling, junction boxes, control panels etc. in plant area ( except chp ) of stage i & ii under sub station mtc. cell, ghtp, lehramohabbat, district: bathinda, punjab as per details given in the tender specifications for a period of one year...
40612581 tender for breakdown, periodical & preventive maintenance of building lighting, street lighting, security lighting and allied equipment like cabling, junction boxes, control panels etc. in plant area (except chp) of stage i & ii under sub station mtc. cell, ghtp, lehra mohabbat district bathinda, punjab...
40593868 construction of balance portion of laboratory cum office building g2 at icar iimr, ladhowal ludhiana including sanitary installation, water supply, drainage, rain water harvesting, tube well, internal external electrical work and development work. sh co shed for dg set at sub station at iimr campus, ladhowal ludhiana pb...
40574750 for outsourcing of cleaning and sweeping (part time sweeper) services at 5 no. sub station under p&m division pstcl, jamsher...
40550933 tender for outsourcing of one no. scorpio/xylo /mahendra bolero /tuv 300 or equivalent in price for the office of addl. s.e. 400 kv sub station pstcl nakodar thunder...
40550735 tender for replacement of 220kv mansa sunam line breaker footing, 220/66kv 100mva p/t/f t 1 breaker footing and other allied civil works at 220kv s/s mansa under p&m division bathinda repair of washroom, walls, painting and allied civil works at 220kv s/s ferozpur under p&m division ferozpur repair of damaged boundary wall and allied civil works at 220 kv sub station lalru repair of damaged recharge well and allied civil works in the yard of 220 kv sub station derabassi...
40547261 laying of tower foundation, erection of tower, stringing and sagging of conductor for 132 kv s/s khera mandir to railway traction sub station pajian (railway deposit work)....
40547226 tender for open e tender notice for e tender enquiry no. 18/tlsc/pta/2023 24 laying of tower foundation, erection of tower, stringing and sagging of conductor for 132 kv s/s khera mandir to railway traction sub station pajian (railway deposit work)....
40498897 maintenance of electronic installation & fans in office building, campus lighting, repair maintenance of dg set, vrv / vrf system, rmo of pump, repair maintenance of of fire alarm system and 315kva sub station in special bureau campus, rauni farm, patiala ( sh: providing e&m services fy 2023 24 ) ...
40467874 tender for 66.k. regarding enlargement of the building of v. sub station, 66 k. regarding enlargement of the building of v. sub station,, new construction of the building of sub division,...
40461915 tender for repair / maintenance of distribution transformers, vcb and connected items of external electric supply at old amritsar cantt 1 excavation in trenches in soft/loose soil not exceeding 1.5 meters wide and not exceeding 1.5 meter depth for laying of ht cables complete, all as specified and as directed. 2 returning filling in trenches including spreading leveling watering and well ramming in layers each not exceeding 25 cm in soft/loose soil complete, all as specified and as directed. 3 removing surplus spoil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meters above the starting point, complete, all as specified and as directed. 4 supply & lay dwc pipe 100 mm bore for laying of lt cables etc complete, with all accessores complete, all as specified and as directed. 5 opening up the top cover of the transformer by taking out the transformer oil in a separate container after disconnecting / taking out the ht/lt side electric connections from both the primary & secondary side of the transformer of any type / description (indoor / outdoor type ) installed on floor/pole for carrying out necessary repair / rewinding to ht/lt side or any other repair as required after shifting the transformer to contractors work shop including taking out complete, core assembly, magger the winding for identifying the fault/defective winding, seggregating the defective winding portion/taking out, cleaning the laminated core rewinding with appropriate gauge winding wire of existing description for transformer of capacity 100 to 250 kva including assembling & testing on completion & installation the same at the site all as specified and directed.note : (i) winding of coil and spares required as per repair shall be measured and paid separately under respective item.(ii) the transpotation charges and taking down/taking up of transformer are inclusive in the quoted rates.(iii) the cost for the dehydration of transformer oil if reqd shall be measured & paid separately.(iv) the cost of insulation material such as paper, cotton tape, latheroid sheet, casl sheet etc are inclusive in the quoted rate. 6 opening up the top cover of the transformer by taking out the transformer oil in a separate container after disconnecting / taking out the ht/lt side electric connections from both the primary & secondary side of the transformer of any type / description (indoor / outdoor type ) installed on floor/pole for carrying out necessary repair / rewinding to ht/lt side or any other repair as required after shifting the transformer to contractors work shop including taking out complete, core assembly, magger the winding for identifying the fault/defective winding, seggregating the defective winding portion/taking out, cleaning the laminated core rewinding with appropriate gauge winding wire of existing description for transformer of capacity 315 to 500 kva including assembling & testing on completion & installation the same at the site all as specified and directed.note : (i) winding of coil and spares required as per repair shall be measured and paid separately under respective item.(ii) the transpotation charges and taking down/taking up of transformer are inclusive in the quoted rates.(iii) the cost for the dehydration of transformer oil if reqd shall be measured & paid separately.(iv) the cost of insulation material such as paper, cotton tape, latheroid sheet, casl sheet etc are inclusive in the quoted rate. 6.01 note for item no 5 & 6 : (i) the transformers will be opened in presence of boo and weight of copper coils damaged and new to be fixed will be done in presence of board officers detailed by accepting officer.(ii) all testing of transformers after repairs will be certified by boo before despatch from the factory (iii) cost of all testing etc is deemed to be incuded in quoted rate and noting extra shall be paid to contractor. 7 opening up the top cover of the transformer by taking out the transformer oil in a separate container after disconnecting/taking out the ht/lt side electric connections from both the primary & secondary side of the transformer of any type/ description ( indoor/outdoor type ) installed on four pole for carrying out necessary repair/replacement of ht/lt side bushes or any other repair as required for transformer of capacity 50 to 500 kva including assembling & testing on completion complete, all as specified and directed. 8 dehydration and filtering the transformer oil with dehydration machine to achieve dielectric strength of the oil to 50 kv at 2.5 mm gap complete, all as specified and directed.note: dehydration machine and other necessary equipments required shall be arranged by the contractor and quoted rates shall be inclusive of this aspect. record of test results after dehydration shall be submitted to the engineer in charge 9 supply and filling for topping up transformer oil in the transformer after dehydration with dehydration machine to achiene dielectric strength of oil to 50 kv at 2.5mm gap complete, all as specified and directed. 10 material & labour for copper winding wire of any size/description suitable for step down power transformer of any capacity, including winding of coils (ht/lt) as per the manufacturers design & specification to obtain rated kva complete, all as specified and directed. 11 supply and fixing lt side brass stud with nuts bolts and washers for transformer of capacity 100 to 200 kva complete, complete, all as specified and directed. 12 supply and fixing lt side brass stud with nuts bolts and washers for transformer of capacity 250 to 500 kva complete, all as specified and directed. 13 supply and fixing ht side brass stud with nuts bolts and washers for trasnformer of capacity 100 to 200 kva complete, all as specified and directed. 14 supply and fixing ht side brass stud with nuts bolts and washers for transformer of capacity 250 to 500 kva complete, all as specified and directed. 15 supply and filling silica gel in different capacity of transformers breathers complete, all as specified and directed. 16 material & labour for air breather assembly complete, with fresh blue colour silcagel suitable for indoor/outdoor type transformer capacity 100 to 200 kva complete, all as specified and directed. 17 material & labour for air breather assembly complete, with fresh blue colour silcagel suitable for indoor/outdoor type transformer capacity 250 to 500 kva complete, all as specified and directed. 18 suppy and fixing in replacement o/c and e/f relay suitable for 630 amp 11000 volts vcb as per sample including provision for fixing in existing panel by cutting/welding work as require at site complete, all as specified and directed. 19 m & l shifting of transformer of capacity 100 kva to 500 kva from one place to other place from two/four pole/plinth in old amritsar cantt area including removing and refixing of ht/lt connections complete, all as specified and directed (all t&p, hydra crane etc required for the job should be provided by contractor, the quoted rate of this item deemed to include ) 20 m & l shifting of transformer of capacity 100 kva to 500 kva from one place to other place from two/four pole/plinth in gg fort area including removing and refixing of ht/lt connections complete, all as specified and directed (all t&p, hydra crane etc required for the job should be provided by contractor, the quoted rate of this item deemed to include) 21 material and labour for fixing aluminium strip 40x10mm, including stainless steel bolts, washers, cutting and making hole as per the lt/ht stud of the transformer of rating 50 500kva complete, all as specified and directed by engineer in charge. 22 suppy and fixing closing coil suitable for 630 amp 11000 volts vcb as per sample complete, all as specified and directed. 23 suppy and fixing tripping coil suitable for 630 amp 11000 volts vcb as per sample and specified and directed. 24 suppy and fixing spring charging motor with gear assembly supply 230 volts ac suitable for 630 amp 11000 volts vcb as per sample complete, all as specified and directed. 25 suppy and fixing frp vaccum bottle support suitable for 630 amp 11000 volts vcb as per sample complete, all as specified and directed. 26 suppy and fixing space heater suitable for 630 amp 11000 volts vcb as per sample complete, all as specified and directed. 27 supply, fixing, connecting and testing in replacement of u/s meter flush type 96x96 mm digital type with lcd display including cutting/welding work all as directed at site of following type and range : 27.01 volt meter 11 kv, suitable for 110/240 volt ac supply suitable for showing three phase values complete, all as specified and directed. 27.02 amp meter for 11 kv vcb 0 200 amp complete, suitable for showing three phase values complete, all as specified and directed. 28 electronic buzzer with input voltage of 230 volt ac and output noise level of 90 120 db (decibels) suitable for control and relay panel and vcb panel as per existing sample complete, all as specified and directed . 29 supply and fixing vcb selector switch, tnc switch for ht vcb panel complete, all as specified and directed 30 supply and fixed led indicator lamp 12/24 dc or 230 ac as required as per sample complete, all as specified and directed. 31 supply and fixing glyphosate 41% sl glykol herbicide to remove vegatation from e/m installations complete, all as specified and directed by engr in charge 32 material and labour for recording earth resistance values of distribution transformer/god/la 11kv/66kv any type strip/wire of any capacity and submitted the record to the engineer in charge complete, all as specified and directed. note: the t&p for the work to be arranged by the contractor and rates are deemed to be included in quoted rates. 33 material and labour for earthing complete, with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip 32x6mm size by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate no. 3 of mes schedule 2009, part – i (specifications) and connected to main switch board / main db’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia gi medium grade, gi funnel made out of 0.63 mm thick gi sheet, wire gauge, 50 mm thick rcc cover in pcc 1:2:4, type b 1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of pcc 1:3:6 type c 1 (using 20 mm graded crushed stone aggregate), gi protection pipe light grade 40 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with cm 1:4 plate size 200 x 150 x 15 mm & painting of earth result etc. including testing on complete, all as specified and directed. note: on testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor without any extra cost to govt. 34 supplying, laying, jointing & testing 2.5 sqmm 4 core pvc insulated, armoured electric cable with flexible stranded copper conductor, 1100 volts grade complete, including taking down old unserviceable cable any type and size complete, all as specified and directed. 35 supplying, laying, jointing & testing 2.5 sqmm 10 core pvc insulated, armoured electric cable with flexible stranded copper conductor, 1100 volts grade complete, including taking down old unserviceable cable any type and size complete, all as specified and directed. 36 material & labour for preparing old painted surface of distribution transformer outdoor / indoor / pole mounted of capacity 100 to 500 kva by cleaning, removing the old paint by scratching with wire brush etc and applying with spray machine two coats of synthetic enamel paint of grey colour or as directed by engineer in charge on external surfaces of the transformer and writing of letter ht / lt or hv / lv and sm / mes nos including disconnecting and making electric connections complete, all as specified and directed.note: (i) the compressure / spray machine and other required necessary equipments shall be arranged by the contractor and quoted rates shall be inclusive of this aspect. 37 material & labour for preparing old painted surface of power transformer outdoor / indoor / pole mounted of capacity 4 mva by cleaning, removing the old paint by scratching with wire brush etc and applying with spray machine two coats of synthetic enamel paint of grey colour or as directed by engineer in charge on external surfaces of the transformer and writing of letter ht / lt or hv / lv and sm / mes nos including disconnecting and making electric connections complete, all as specified and directed.note: (i) the compressure / spray machine and other required necessary equipments shall be arranged by the contractor and quoted rates shall be inclusive of this aspect. 38 material and labour for filling fine river sand in the trench below power transformer and trencehes of ht vcb including levelling and spreading complete, all as specified and directed. 39 supply and fixing in replacement of pin type insulator polymer insulator with capacity of 11kv and gi pin, including gi nuts,bolts and washers, binding conductor and insulator with gi wire complete, all as specified and directed. 40 supply, installation, connecting, and testing of 11 kv single phase indoor resin cast ct of ratio 600/300/1 1a suitable for vcb as per existing type and make including taking down old unserviceable ct complete, all as specified and directed. 41 supply, installation, connecting, and testing of 11 kv single phase indoor resin cast ct of ratio 300/150/5 5a suitable for vcb as per existing type and make including taking down old unserviceable ct complete, all as specified and directed. 42 supply, laying, jointing and testing ht xlpe cable cross section area 185 sqmm, 3 core, 11000 volts screened earthed, pvc e grade insulated bedded, galvanised steel (heavy duty ) strip or wire armoured with alluminium conductor 11 kv pressure earthed system conforming to is 7098 (part 1 ) 1977 and part ii of 1985 laid in pipes /ducts/ trenches,under floor and roads or fixed to wall etc including taking out old unserviceable cable any type complete, all as specified and directed. 43 material and labour for testing and calibration of indoor type vaccum circuit breaker for carrying out contact resistance measurement, circuit breaker trip time, insulation resistance and coil resistance test complete, including checking of wiring defect and rectifcation if any at site and submission of report. the quoted rates included general servicing, greasing of mechanical gears of the breaker etd at site complete, all as specified and directed by engineer in charge.note for item no 40 to 43 : (i) the cost of t&p and other expenses such as boarding and lodging of testing team etc are deemed to be included in the quoted rates. (ii) the replacement of major parts shall be measured and paid separately under relevant item of the schedule. 44 m&l outdoor type cable end termination kit, heat shrinkable jointing material and accessories complete, suitable for 11 kv ht xlpe underground cable size 50 to 95 sqmm 3 core including testing after jointing complete, all as specified and directed. 45 m&l outdoor type cable end termination kit, heat shirnkable jointing material and accessories complete, suitable for 11 kv ht xlpe underground cable size 120 to 185 sqmm 3 core including testing after jointing complete, all as specified and directed. 46 m&l outdoor type cable end termination kit, heat shrinkable jointing material and accessories complete, suitable for 11 kv ht xlpe underground cable size 240 to 300 sqmm 3 core including testing after jointing complete, all as specified and directed. 47 m&l cable straight through joint box type suitable for 11 kv u/g xlpe screened pvc bedded gi strip or wire armoured cable size 50 to 95 sqmm 3 core heat shrinkable,. termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type compelete all as specified and directed. 48 m&l cable straight through joint box type suitable for 11 kv u/g xlpe screened pvc bedded gi strip or wire armoured cable size 120 to 185 sqmm 3 core , heat shrinkable, , termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type compelete all as specified and directed. 49 supply and fixing in replacement of ht jumper of existing two/four pole structure of transformer etc using 95 sqmm single core aluminium cable conductor , including pg clamp nut, bolts, thimbles and washers etc as required at site complete, all as specified and directed. 50 supply only ht fuse wire for existing two/four pole structure of transformer of suitable rating ( 5/10/15/20/25 amp )fuse wire complete, all as specified and directed. 51 supply, installation, commissioning and testing of switch air break, gang operated with 12 insulator polymer type type switch triple pole mechanicaly operated, mounted on insulator and steel frame, with separating mechanism worked from ground level, for current rating 400 amp operating voltage 11 kv out door type vertical mounted type complete, with locking arrengement,assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 kv including necessary electric connection and 11 kv fuse (drop out type) of capacity as per site requirement and as specified by engineer in charge, complete, with do fuses assembly with channel and one number operating rod of 25 mm dia bore grade gi pipe of suitable length worked out from ground level and handle complete, with lock and two keys including flat iron clamp 50mm x 6mm ms channel of suitable size & length for fixing god with nut,bolt, washers etc including taking down existing set complete all as directed by engineer in charge. 52 shifting of 11 kv vcb of any capacity any make from one sub station to other sub stn (with in 4 kilometer) in old amritsar cantt area including removing and refixing of ht connections complete, all as specified and directed. (note : all t&p, hydra crane etc required for the job shall be provided by contractor, the quoted rate of this item deemed to be included) 53 m&l for prunning and removing of tree branches touching to electric over head lines wild growth around lt /ht over head lines and around pole and stay complete, to make clear span of 2 metre of tree both side of the oh line with jcb, cutter and all tools, plants etc all as directed by engineer in charge.note : (i) distance between pole to pole will be measured and paid. (ii) contractor has to take upmost care to avoid damage to existing lines/structures if any breakdown of line caused during punning shall be made good without any extra cost. (iii) prunning of tree to be done twice a year (before & after rainy season) (iv) the contractor has to ensure the proper safety of the tradesman to avoid any mishappening. if any mishappening occures the contractor will be solely responsible for it and he has to compensate damages. 54 m&l for checking of ht ug 11 kv xlpe faulty cable with ht ug cable fault locating testing machine, rectifing the fault, putting the jointing kit and charging the cable as all as specified and directed. (approx length 500 rm for each job) (note : the rate for excavation, removing of old cable, laying after repairs is demmed to be included in the rate quoted by the contractor). 55 m & l for replacement of danger notice for ht, 25x20cm size plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with m.s. clamps of size 25x4mm, bolts and nuts of approved size complete, all as specified and directed. 56 m&l for cleaning with ctc ,greasing and maintenence and alignment of horizontal type air break switch, gang operated, tripple pole, mechnically operated, outdoor type, with all fittings and accessories mounted on and including ht 66 kv porcelain insulators and steel channel frame, gi operating rod suitable size dia of suitable length to worked from ground, including locking arrangements , suitable for 66000 volts, 3 phase complete, all as specified and as directed. 57 s&f in replacement of ht 66 kv out door non linear type lightening arrestor with mountings, accessories complete, fixed on cross arms of two pole structure / gi flat strip and connect with same size of acsr conductor encashed in pvc alkathine pipe with all fittings connected to earth strip with nuts, bolts and washers, transmission class having discharge current capacity of 10 ka and voltage heavy duty staion class 66 kv/75 kv maximum, maximum continuous operating voltage 66 kv, rated short circuit current 20 ka complete all as specified and as directed. 58 m&l for renewal of earthing of poles/system with chemical earthing with 3 mtr long 50 mm dia gi pipe alongwith connected copper earth strip 25x3 mm below ground level and connected to copper strip dia by means of nuts, bolts and washers and encased in and including 15 dia gi medium grade pipe upto 2.4 mtr height form ground level fixed by ms flat iron clamp 40mm x 6mm with nut, bolt and washers, gi strip fixed to base along pole and connected to over head line for providing earthing to ht pole/feeder ab switch la complete, with charcoal dust, salt packed around plate 150 mm thick including watering gi pipe, medium grade 40 mm dia with blanking cap 1.5 mtr long fixed to funnel with wiremesh complete, with pcc chamber and rcc chamber over all as per electrical plate no 3 of ssr part i 2009 including excavation and earth work in any type of starta and testing on compeltion complete, all as specified and directed. (note: any length of gi strip and 15 mm dia gi medium grade pipe shall be provided as per actual requirement at site). 59 m&l for pipe earthing by digging a bore of 150 mm dia and inserting gi pipe heavy grade 100 mm dia 10 mtr long including gi strip 32x6 mm and charcoal and salt around the pipe in alternate layers, and gi strip upto 7.5 mtr above ground level including earth pit and test point complete, all as specified and directed by e in charge . 60 supply and spreading in electrical outdoor installation yard, stone aggregate of size 25 mm at 11kv substations / near dp structures after thorough cleaning, anti grass treatment etc complete, all as specified and directed. 61 supply and spreading in electrical outdoor installation yard, stone aggregate of size 20 mm at 11kv substations / near dp structures after thorough cleaning, anti grass treatment etc complete, all as specified and directed. 62 supply only 11 kv pt fuse as per sample, complete, all as specified and directed. 63 supply only control fuse links ns type 2a, 4a, 6a,10a,16a as per sample, (20 each= 5 x 20 = 100 number in one set) complete, all as specified and directed. 64 supply only trip circuit healthy push button as per sample complete, all as specified and directed. 65 supply only tnc switch as per sample as per sample complete, all as specified and directed. 66 supply only shunt trip coil 30 volt, dc assembly as per sample complete, all as specified and directed. 67 supply only bottom contact support insulator as per sample complete, all as specified and directed. 68 supply install test and commissioing of current transformer of vcb 11 kv all as per sample and complete, all as specified and directed. 69 supply install test and commissioing of potential transformer of vcb 11 kv all as per sample and complete, all as specified and directed. 70 m & l for resin cast type twin secondary current transformer of ratio 200 100/5 5a class – i sp – 10 for protection and metering , capacity 15va/15va burden for protection and metering to conform is – 2705 of 1992 complete, all as specified and directed. 71 material and labour for servicing and testing of outdoor type three phase sf6 circuit breaker for carrying out contact resistance measurement, circuit breaker trip time, insulation resistance and coil resistance test complete, at site and submission of report. note: the cost of t&p and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. the quoted rates included general servicing, greasing of mechanical gears, gas recharging of the breaker etd at site complete, all as specified and directed by engineer in charge. 72 material and labour for servicing of control and relay panel (c&r panel) of transformer includung testing of differential relay , idmt relays and other auxiliary relays of transformer protection with secondary injection test kit complete, at site and submission of report complete, all as specified and directed by engineer in charge.note: the cost of t&p and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. the quoted rates included general servicing, checking of wiring, replacement of minor parts etc. 73 material and labour for testing of 66 kv outdoor type ct and carrying out tests i.e ir test, polarity test, knee voltage test, ratio test with primary injection kit complete, all as specified and directed by engineer in charge.note: the cost of t&p and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. the quoted rates included general servicing, checking of wiring, replacement of minor parts etc. 74 dehydration and filtering the transformer oil with dehydration machine to achieve dielectric strength of the oil to 60 kv at 2.5 mm gap complete, all as specified and directed .note: dehydration machine and other necessary equipments required shall be arranged by the contractor and quoted rates shall be inclusive of this aspect. record of test results after dehydration shall be submitted to the engineer in charge 75 supply and filling for topping up transformer oil in the transformer after dehydration with dehydration machine to achieve dielectric strength of oil to 60 kv at 2.5mm gap complete, all as specified and directed. 76 supply only glyphosate 41% sl glykol herbicide to remove vegatation from e/m installations complete, all as specified and directed by engr in charge 77 supply only insulating mat as per is 15652, 2.5 mm thick suitable for 11 kv supply complete, all as specified and directed. 78 supply and fix digital voltmeter suitable for ht vcb panel 66 kv as per sample complete, all as specified and directed. 79 supply and fix digital ammeter suitable for ht vcb panel 66 kv, 0 100 amp as per sample complete, all as specified and directed. 80 supply and fix led indicator lamps as per sample complete, all as specified and directed. 81 m & l for servicing and overhauling of sf6 circuit breaker 66 kv incl cheking of wiring connectsions and repairs of thr same complete, incl replecement of minor parts complete, all as specified and directed. 82 supply and fix in replacement thermostat of vcb as per sample complete, all as specified and directed. 83 supply and fix in replacement space heater of vcb as per sample complete, all as specified and directed. 84 supply and fixing pole mounted with ms brackets box for housing the electrical terminals / control of vcbs out door type made out of crca sheet 3.15 mm thick of size 60cm (height) x 45 cm (width) and 30 cm depth including nut /bolts checknut of washers duly powder coated complete, with locking arrangement complete, all as specified and directed. 85 m & l for ht cable entry sealing in ht 11 panel with ms sheet 2 mm thick cut as per site requirement and pop complete, all as specified and directed. 86 supply and fix cable route indicators with pcc 1:2:4 , b1 in replcement for ht 11 kv supply all as specified and dircted by e in charge duly engraved with ht cable and having angle iron support of size 40x40x4 mm and 60 cmlong duly embeded in pcc complete, all as specified and directed. 87 labour only for connecting existing earth strips with gi earth strip of size 40x6mm complete, with welding as and where complete, all as specified and directed. note : gi earth strip of size 40x6 mm will be measured and paid separately. 88 supply & fixing gi earth strip of size 32x6 mm with gi protection pipe light grade 40 mm bore above 7.5 mtrs length of earth electrode and connected complete, all as specified and directed. 89 m&l for maint and cleaning of ht 66 kv switch yard including complete cleaning of jumper connections joints, god contacts, contact pipe , inslutaors in the yard with ctc in tighening of connections including replacement of thimbles connectors etc complete, all as specified and directed. 90 m & l for replacement of pcc cover of cable trenches with ms chequred plates of 8 mm thick complete, with suitable size angle irons grouted for supports complete, all as specified and directed. ...
40439531 tender for outsourcing of one no. scorpio/xylo /mahendra bolero /tuv 300 or equivalent in price for the office of addl. s.e. 400 kv sub station pstcl nakodar thunder...
40436536 tender for : reconstruction of building of bbmb 66 kv and 11 kv sub station at sub station vyas dam site and 33 kv sub station...
40397709 renovation of the buildings of bbmb 66 kv and11 kv sub station at beas dam site and 33 kv sub station at sansarpur terrace...
40393499 maintenance of electronic installation & fans in office building, campus lighting, rmo dg set, vrv / vrf system, repair maintenance of of pump set, fire alarm system and 315 kva sub station at cec, patiala ( sh: providing amc of cctv system and supply installation testing commissioning of camera and split ac ) ...
40392677 extension of control room (s.h.b) at 66 kv sub station pspcl, chawa...
40384531 tender for mess by tapping of 66 kv modern steels from 220 kv sub station g 1, mgg. increase in laud of surya stall industries, ambe majra mandi govindgarh (revised) (deposit work) (village ambe majra) by tapping the existing 66 kv oasis line, mass impression securities pvt. increase in load of limi talwara road mandi gobindgarh (deposit work) (location talwara road, mandi govindgarh) as part of the north south corridor doconnection in the state of punjab on hum mode under bharat mala project starting from kahalwan (nh 03) (0 km) to kang sabu (nh 703) (46 500 km) .) due to development of 6 lane jalandhar bypass, shifting of 66 kv rihana jahan patara sco on dc line (deposit work of nhai) (village nangal fateh khan, pavada) 220 kv ss dhanaula to 66 kv s/ s iol fatehgarh chatra 66 kv line (deposit work) (village dhanaula, fatehgarh chana) stringing of hoshiarpur nasrala line up to mc kt tower including reorientation of pantry at 220 kv ss hoshiarpur (location 220 kv sub station hoshiarpur). new 66 kv sc on dc line (deposit work) from village maujewal to 66 kv sub station at saroa from the proposed site of 50 mw solar plot (village pjewal), toroval, karimpur navagram, saroa) 220 kv gs/s kot karor to 66 kadi ss mirjes new 66 kv sc on dc line (village karor kalan, lai bholuwala, tubharwala, pali sardaran wali, jeet singh wala, loham, bada bhaika mirje k jhokhe harihar to tibbi khurd is 1 km from the present railway track firozpur fazilka. 12/1 raising shifting of existing 66 kv rp line at 2 crossings (begu month)...