Bhakra Beas Management Board - Punjab

34182906 bids are invited for gi pipes for use with submersible pump alongwith jointing accessories , cable for 35 bhp deep submersible bore tube well isi marked , nuts and bolts , jain , repair and with supply of material mse upgradation of 35bhp submersible pump from stage 3 to 4one stage extended along with replacement of material asmentioned in item descriptionrepair and upgradation of 35hp submersible pump along total quantity : 186...

Department Of Local Bodies - Punjab

34154335 rough cost estimate for installing new tube well ( size 300 mm x 200 mm depth up to 450m ) including pumping machinery, ci fitting etc. at sector 78 near guru asra trust under the jurisdiction of mc mohali at s.a.s nagar rough cost estimate for installing new tube well ( size 300 mm x 200 mm depth up to 450m ) including pumping machinery, ci fitting etc. at sector 78 near guru asra trust under the jurisdiction of mc mohali at s.a.s nagar...

Border Security Force - Punjab

34121639 construction of c / o changing room, pump house and deep bore well for astro truff hockey court at ftr hq bsf campus jalandhar ( sh c / o deep tube well at bsf campus jalandhar under ftr hq bsf jalandhar ) as per nit...

Municipal Corporation - Punjab

34085770 tender for providing/installation of tube wells, 2) empanelment of contractors for annual rate contract for attending regarding maintenance of tubewells and water supply and sewerage....

Water Resources Department - Punjab

33965713 material required for running and maintenance of tube wells of hargobindpur block under tubewell division pwrmdc ltd pathankot material required for running and maintenance of twells of hargobindpur block under tubewell division pwrmdc ltd pathankot , fuse unit gkh kit kat ( porcelain ) rewireable type conform to is2086 / 93 200amp 415 volt with extension strip...

Water Resources Department - Punjab

33965709 material required for running and maintenance of tube wells of hargobindpur block under tubewell division pwrmdc ltd pathankot material required for running and maintenance of twells of hargobindpur block under tubewell division pwrmdc ltd pathankot , bch make 40amp nhd series 4 pole contactor size 1 cat n01n , bch make 40amp duros freedom pole ac control contactor size g cat no. ce15gn3 , bch make ct operated overload relay range 24.4 to 39amp cat no. mc305ana3c...

Northern Railway - Punjab

33938276 supply of balance work for provision of two nos deep tube wells in station area at jammu tawi railway stationbalance work for provision of two nos deep tube wells in station area at jammu tawi railway station, ...

Water Supply And Sanitation Department - Punjab

33930005 providing & installing new deep tube well size 250x200 mm i / d up to 130mtr. depth bgl with reverse rotary rig, pumping machinery, rising main, chlorinator, development for existed water work sites, distribution of pipeline, household water connection with water meter, repair of existed pump chamber & existed rcc ohsr at water supply scheme mallah, block jagraon, district. ludhiana. ( under nabard ridf xxvii ) / jjm ) ...

Water Supply And Sanitation Department - Punjab

33930003 providing and installing pvc tube well 200 mm dia upto 120mtr. depth with hand boring, pumping machinery, disinfection unit electrically based and construction of pump chamber 3.05 x 3.70 m including gravil pit , complete in all respects & providing, laying, cutting, jointing & testing of pvc pipe 6kg / cm2 for distribution. including cost of excavation, dismantling & relaying of dry brick on edge paving and dismantling of metalled road and the restoration of the metalled road to its original condition , house hold water connection with water meter, development of water works site i.e.corner pillars, barbed wire fencing, d hooks, gate pillars, foot path, sign board, including carriage of material complete in all respect and o&m of scheme for 3 months after execution of work at site. under head narbard xxiiiname of scheme water supply scheme chak mahantan wala, block guruharsahai, distt ferozepur...

Water Supply And Sanitation Department - Punjab

33930000 providing & installing new deep tube well size 250x200 mm i / d up to 130mtr. depth bgl with reverse rotary rig, pumping machinery, rising main, chlorinator, development for existed water work sites, distribution of pipeline, household water connection with water meter, repair of existed pump chamber & existed rcc ohsr at water supply scheme lakha, block jagraon, district. ludhiana. ( under nabard ridf xxvii ) / jjm...

Water Supply And Sanitation Department - Punjab

33809150 boring & installing a deep tube well of size 2sox200mm im 25omtr.deep bol wiah rr rig. pro’. laying, juinting. cutting, testins of 100mn di. pioe for rising main, p / i pumping machinery, disinfection unit etc complete.at mob. akash colony llsp. cus 24.24 lac...

Punjab State Power Corporation Limited - Punjab

33774509 e tender for the work of 1) boring and installation of one number tube well of 12’x8” size and 250 m depth with gravel packed complete in all respects for water supply to 66 kv grid colony, pspcl, patiala, 2) boring and installation of one number tube well of 1 2’x8” size and 250 m depth with gravel dacked complete in all respects for water supply to power colony no. 2 and shakti vihar complex pspcl, patiala, 3) cement based paint, white washing, enamel daint etc. for non residential buildings at head office complex, pspcl. patiala and 4) comprehensive repair and maintenance of 4 no. passenger lifts in 7 storey building at head 0ffice complex, pspcl, patiala. for detailed nit and tender specifications please refer to https://eproc....

Border Security Force - Punjab

33641397 construction of c / o changing room, pump house and deep bore well for astro truff hockey court at ftr hq bsf campus jalandhar ( sh c / o deep tube well at bsf campus jalandhar under ftr hq bsf jalandhar ) as per nit...

Northern Railway - Punjab

33627865 supply of electrical work in c/w construction of 20 bedded barrack for disaster management, ticket checking squad & training facilities at ludhiana under aden/ldh, electrical work in connection with re development of old bores and provision of new tube wells and replacement of ms overhead tank with sms tank at ludhiana station and colony area under aden/ldh,electrical work in c/w raising of rail level/low level passenger platform to high level & provision of fob at malsian shahkot & raising of rail level/low level passenger platform to high level & provision of fob at bilga on phr lnk section of firozpur division.electrical work in c/w construction of 20 bedded barrack for disaster management, ticket checking squad & training facilities at ludhiana under aden/ldh, electrical work in connection with re development of old bores and provision of new tube wells and replacement of ms overhead tank with sms tank at ludhiana station and colony area under aden/ldh,electrical work in c/w raising of rail level/low level passenger platform to high level & provision of fob at malsian shahkot & raising of rail level/low level passenger platform to high level & provision of fob at bilga on phr lnk section of firozpur division.,...

Water Supply And Sanitation Department - Punjab

33613249 providing and installing tube well 250 x 200 mm i d depth 150 mtr with reverse rotary rig, providing and installing submersible pumping set reputed make discharge 731 lpm head 79.00 mtr ( 22.50 bhp ) ...

Bhakra Beas Management Board - Punjab

33613205 maintenance of existing main water supply pipeline , replacement of valves, replacement of filter media, development of tube wells in wtp at nangal and repair / maintenance of sluice valve chamber and other maintenance work in nangal water supply arrangements and water treatment plant at nangal township...

Water Supply And Sanitation Department - Punjab

33602860 installation of new tubewell size 150mm i / d straight 150 mtr depth, construction of rcc ohsr 15000 ltr., pump chamber size 2.50 x 2.50m, distribution system, chlorinator, private water connection with water meter, pumping machinery & development of water works site at water supply scheme village tirak karma ( 2 no. ) block & distt. ropar ( under prwssip 1a ( iii ) / jjm ) pkg 2 ( ohsr & civil works construction of rcc ohsr 15000 ltr, pump chamber etc. construction of rcc ohsr 15000 ltr., pump chamber size 2.50 x 2.50m, distribution system, chlorinator, private water connection with water meter, pumping machinery an development of water works site at water supply scheme village tirak karma ( 2 no. ) , ohsr , constructing one no. of 15 kl ( 15000 litres ) capacity with sill level not less than 15.00 m height upto fsl complete with external rcc stair case with landing slabs at each staging rcc roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule no.3. providing and fixing di k 9 d / f expansion joints conforming to ( is 8329 / 2000 ) or latest bell mouth and d / f puddle collars as per dwss design on basis of enclosed drawing. duck foot bends, conforming to isi 13382 and di k 9 d / f sluice valve duly isi marked ( is 14846 2000 or latest ) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow di k 9 double flanged pressure pipes horizontally cast in sand moulds as per is 7181 / 1986 and latest duly isi marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. tmt steel & painting of all complete shall be included in cost & p / f aluminium leader inside the ohsr complete in all respect as per specifications. ( the specifications & drawing are based on safe bearing capacity of soil of is less than 8.75 tone per sqm. in case the safe bearing capacity of sail is less than 8.75 tone per sqm. the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per dwss specifications. the difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per csr+ prevailing ceiling preminum including providing and fixing automatic electronic water level control device and construction of plinth protection around ohsr with masonry toe wall with 40 mm thick cc 1:2:4 on top over 100 mm thick cc 1:8:16 & inside earth filling within lead of 5 km, including overflow haudi complete in all respects. , pumping main ( rising main ) , providing, laying , fixing & jointing ofp.v.c. pipes as per isi 4985 ( isi marked with the prior approval of engineer in charge ) along the trenches and laying the same in trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including excavation. ( manualy ) , 90mm o / d pipe of 10 kgf. / sqcm , providing & fixing c.i / d.i flanged end, stem of ss ( ais 1410 ) and bronze ( gunmetal ) working parts sluice valves isi marked 14846 2000, including jointing, testing & cost of nut, bolt & insertion sheet, all carriage complete ( with the approval of engineer in – charge ) , 80 mm i / d , providing, fixing & jointing cast iron surface box for sluice valve, air valve, fire hydrant etc. including all carriages complete , construction of masonry sluice valve chamber excluding sluice valve cover as per standard design & drawings of public health department ( 2 no. each of size 0.6m x 0.6m ) , pump chamber 2.50 x 2.50 mtr. , construction of pump chamber size 2.50m×2.50mtr, with gravel pit but including electric wiring as per dwss standard design & analysis, complete in all respects. extra for provision for sanitary latrinein pump chamber for foundation and plinth of wc rooms including flooring, pvc pipes, junction box, 1 nos. leach pits, super structure wc room etc. , distribution system , providing, stringing out pvc pipes as perisi 4985 ( isi marked with prior approval of engineer in charge ) casting along the trenches and laying the same in trenches to correct alignment and gradients, cutting. jointing and testing, including excavation & specialscomplete as per specifications for less than 3 mtr street width. complete in all respect ( manual ) imp. note: excavation item no. 28.2 ( ii ) ( for ordinary soil having gravel upto 40% ) is taken as the area of village falls in kandi area , pvc pipe63mm o / d , providing, stringing out pvc pipes as perisi 4985 ( isi marked with prior approval of engineer in charge ) casting along the trenches and laying the same in trenches to correct alignment and gradients, cutting. jointing and testing, including excavation & specialscomplete as per specifications for for more than3 mtr street width complete in all respects ( mechanical means ) note: excavation item no. 28.1 ( ii ) ( for ordinary soil having gravel upto 40% ) is taken as the area falls in kandi area , pvc pipe63mm o / d , pvc pipe90mm o / d , dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting. , pvc pipe63mm o / d , dismantling of mettalic road with bitumainous course 50mm to 75 mm thick cc 1:8:16 and making good the same to its original condition. complete in all respect as per instructions / directions issued by eic , pvc pipe63 mm o / d , dismantling of cement concrete 80mm thick cement concrete 1:2:4 over 100mm thick c.c. 1:8:16 and making good the same to its original condition complete in all respects as per analysis a 25 , pvc pipe63mm o / d , providing and fixing and jointing isi marked gun – metal peet valves ( heavy pattern ) as peris 778 with hand wheels, on g.i pipe lines laid in the ground or inside buildings including all carriages complete , 65 mm i / d , hand boring horizontly for crossing of pipe under road or any other obstacle by using auger / bocki method.including excavation , stringing and jointing of pipe upto 160mm complete , private water connections including water meter , providing proposed water connection to house hold up to wall with providing, laying jointing, testing gi pipe lines 15mm i / d=2.50 mtr b class as per csr 28.36 ( a ) , ( above gl ) , prov. & fixing mdpe pipe 15mm i / d with specials 2.00 mtr ( below gl ) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and isi marked 15mm i / d gm ferrule as per is: 2692 and 3 i / d clamp with c.i bib cock 15mm i / d as per is:210 with stainless steel spindle of approved make as per csr 30.65 ( b ) , providing, fixing & jointing water meter ( muti jet ) in gi pipe line including cutting & therading pipe and making long screw etc. complete including cost of gi jain, nut complete. ( 15mm ) , chlorinator , prov. installing, testing & commissioning one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator , suitable for delivering 0.5 to 6 litres of bleaching powder solution / sodium hypo solution per hour under maximum delivery pressure up to 7 kg.cm2, and suction lift not less than 1.5 m, as per dwss. standard specifications. , pumping machinery , providing, installing, testing and commissioning of 1 no. 3 bhp electrically driven pumping set of reputed make , capable ofdeleviring 100 lpm against a head of 39 mt . complete in all respects , supplying lowering of 50 mm dia gi d / f pipe as per is 1239 ( b class ) premim makesuch ( as jindal hisar ) including cost of specials such as tees, bends , sockets elbow etc, cutting , treading and testing in trenches in the ground. complete in all respects , providing and fixing of submerssible of 2.50 mm ² core cable , complete in all respect , providing installing, testing and commissioning of1 no.controlpanel ( ec / ws ) electricity & water saver, 1 hp to 12.50 hp oil immersed 2 set contactor complete job including indicators, switches, over load functions , line fault protection , power saving functionsas permanufacturerspecifications, details& enclosure etc. complete in all respect including carriage , gst as applicable & installation charges. , c.ifitting inside pump chamber , providing and installing 80mm dia delivery main ( from tube well to duck foot bend including cost of c.i / d.f pipes, d / f sluice valves, d / f nrv & specials as c.i bends, tail piece tees etc.. inside the pump chamber as per standard design complete in all respects , construction of v notch houdi ( size 1.80 x 0.90 m ) including cost of v – notch as per standard design & drawings of public health department , solar panel , providing, fixing, installing, commissioning, solar panel energy system ( monocrystalline ) for amount of electric power required for running electric motor and other appliances such as fan, tube, bulb etc in water works site. including bi directional meter and inverter of suitable capaity as per guidelines issued by peda complete in all respects. , development of water works , providing & fixing g.i. barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard drawing d 6 & 8 ( as per analysis a 6 ) , providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard drawing d 8 & ( as per analysis a 6 ) . , providing & fixing d.hook complete with ms bolts size 300mm x 18mm as per standard drawing d 7 & analysis a 7 , construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard drawing d 3 & analysis a 3. , construction of masonry gate pillar including cost of ms steel gate size 1.22mtr x 1.37 mtr as per standard drawing with including d 4 & analysis a 4 complete in all respects , construction of cement concrete, foot path with masonry toe wall & earth filling inside water works as per standard drawing d 7 & analysis a 10. , providing & fixing ms sign board as per standard size of dwss as per analysis a 24 & drawing d 20 , construction of toe wall around the water works site ( 0.45 mtr depth ) , enviornment , rough grassing including uprooting rank vegetation and weeds by digging the area to a depth of 15 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, mixing fertilizer, levelling and dressing for planting new grass, including disposal of all rubbish with all leads and lifts, planting doob grass in rows 15 cm apart in both directions, watering and maintenance till first mowing. , digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm yard manure @ 30% of pit volume and insecticide for termite control , supplying and planting permanent trees in prepared pits and watering , supplying and planting permanent shrubs in prepared pits and watering , carriage of material , extra for carriage of fine & course aggregate i.e. sand & bajri from query to water works site beyond 5 km ( qty as worked out for the components to be constructed detail 1.9 & rate as per lead on csr + ceiling premium for the applicable lead beyond first 5 km ) 30 km. , sand & bajri , operational & maintenace , operation and maintenance of water supply scheme for 3 months excluding electrical charges complete in all respects...

Water Supply And Sanitation Department - Punjab

33559159 construction of rcc ohsr 15000 ltr,pump chamber etc. construction of rcc ohsr 15000 ltr.,pump chamber size 2.50 x 2.50m, distribution system, chlorinator, private water connection with water meter, pumping machinery and development of water works site at water supply scheme village tirak karma (2 no.) , ohsr , constructing one no. of 15 kl (15000 litres) capacity with sill level not less than 15.00 m height upto fsl complete with external rcc stair case with landing slabs at each staging rcc roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule no.3. providing and fixing di k 9 d/f expansion joints conforming to (is 8329/2000) or latest bell mouth and d/f puddle collars as per dwss design on basis of enclosed drawing. duck foot bends, conforming to isi 13382 and di k 9 d/f sluice valve duly isi marked (is 14846 2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow di k 9 double flanged pressure pipes horizontally cast in sand moulds as per is 7181/1986 and latest duly isi marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. tmt steel & painting of all complete shall be included in cost & p/f aluminium leader inside the ohsr complete in all respect as per specifications. (the specifications & drawing are based on safe bearing capacity of soil of is less than 8.75 tone per sqm. in case the safe bearing capacity of sail is less than 8.75 tone per sqm. the contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per dwss specifications. the difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per csr+ prevailing ceiling preminum including providing and fixing automatic electronic water level control device and construction of plinth protection around ohsr with masonry toe wall with 40 mm thick cc 1:2:4 on top over 100 mm thick cc 1:8:16 & inside earth filling within lead of 5 km, including overflow haudi complete in all respects. , pumping main (rising main) , providing, laying , fixing & jointing ofp.v.c. pipes as per isi 4985 (isi marked with the prior approval of engineer in charge) along the trenches and laying the same in trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications including excavation. (manualy) , 90mm o/d pipe of 10 kgf. / sqcm , providing & fixing c.i/d.i flanged end, stem of ss (ais 1410) and bronze (gunmetal) working parts sluice valves isi marked 14846 2000, including jointing, testing & cost of nut, bolt & insertion sheet, all carriage complete (with the approval of engineer in – charge) , 80 mm i/d , providing, fixing & jointing cast iron surface box for sluice valve, air valve, fire hydrant etc. including all carriages complete , construction of masonry sluice valve chamber excluding sluice valve cover as per standard design & drawings of public health department (2 no. each of size 0.6m x 0.6m) , pump chamber 2.50 x 2.50 mtr. , construction of pump chamber size 2.50m×2.50mtr, with gravel pit but including electric wiring as per dwss standard design & analysis, complete in all respects. extra for provision for sanitary latrinein pump chamber for foundation and plinth of wc rooms including flooring, pvc pipes, junction box, 1 nos. leach pits,super structure wc room etc. , distribution system , providing, stringing out pvc pipes as perisi 4985 (isi marked with prior approval of engineer in charge) casting along the trenches and laying the same in trenches to correct alignment and gradients, cutting. jointing and testing, including excavation & specialscomplete as per specifications for less than 3 mtr street width. complete in all respect (manual) imp. note: excavation item no. 28.2 (ii) (for ordinary soil having gravel upto 40%) is taken as the area of village falls in kandi area , pvc pipe63mm o/d , providing, stringing out pvc pipes as perisi 4985 (isi marked with prior approval of engineer in charge) casting along the trenches and laying the same in trenches to correct alignment and gradients, cutting. jointing and testing, including excavation & specialscomplete as per specifications for for more than3 mtr street width complete in all respects (mechanical means) note: excavation item no. 28.1 (ii) (for ordinary soil having gravel upto 40%) is taken as the area falls in kandi area , pvc pipe63mm o/d , pvc pipe90mm o/d , dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting. , pvc pipe63mm o/d , dismantling of mettalic road with bitumainous course 50mm to 75 mm thick cc 1:8:16 and making good the same to its original condition. complete in all respect as per instructions / directions issued by eic , pvc pipe63 mm o/d , dismantling of cement concrete 80mm thick cement concrete 1:2:4 over 100mm thick c.c. 1:8:16 and making good the same to its original condition complete in all respects as per analysis a 25 , pvc pipe63mm o/d , providing and fixing and jointing isi marked gun – metal peet valves(heavy pattern) as peris 778 with hand wheels, on g.i pipe lines laid in the ground or inside buildings including all carriages complete , 65 mm i/d , hand boring horizontly for crossing of pipe under road or any other obstacle by using auger/bocki method.including excavation , stringing and jointing of pipe upto 160mm complete , private water connections including water meter , providing proposed water connection to house hold up to wall with providing, laying jointing, testing gi pipe lines 15mm i/d=2.50 mtr b class as per csr 28.36 (a),( above gl), prov. & fixing mdpe pipe 15mm i/d with specials 2.00 mtr (below gl) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and isi marked 15mm i/d gm ferrule as per is: 2692 and 3 i/d clamp with c.i bib cock 15mm i/d as per is:210 with stainless steel spindle of approved make as per csr 30.65(b) , providing, fixing & jointing water meter (muti jet) in gi pipe line including cutting & therading pipe and making long screw etc. complete including cost of gi jain, nut complete. (15mm) , chlorinator , prov. installing, testing & commissioning one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator ,suitable for delivering 0.5 to 6 litres of bleaching powder solution/sodium hypo solution per hour under maximum delivery pressure up to 7 kg.cm2, and suction lift not less than 1.5 m, as per dwss. standard specifications. , pumping machinery , providing, installing, testing and commissioning of 1 no. 3 bhp electrically driven pumping set of reputed make , capable ofdeleviring 100 lpm against a head of 39 mt . complete in all respects , supplying lowering of 50 mm dia gi d/f pipe as per is 1239 (b class) premim makesuch (as jindal hisar) including cost of specials such as tees, bends , sockets elbow etc, cutting , treading and testing in trenches in the ground. complete in all respects , providing and fixing of submerssible of 2.50 mm ² core cable , complete in all respect , providing installing, testing and commissioning of1 no.controlpanel (ec/ws) electricity & water saver, 1 hp to 12.50 hp oil immersed 2 set contactor complete job including indicators, switches, over load functions , line fault protection , power saving functionsas permanufacturerspecifications, details& enclosure etc. complete in all respect including carriage , gst as applicable & installation charges. , c.ifitting inside pump chamber , providing and installing 80mm dia delivery main (from tube well to duck foot bend including cost of c.i/d.f pipes, d/f sluice valves, d/f nrv & specials as c.i bends, tail piece tees etc.. inside the pump chamber as per standard design complete in all respects , construction of v notch houdi (size 1.80 x 0.90 m) including cost of v – notch as per standard design & drawings of public health department , solar panel , providing, fixing, installing, commissioning, solar panel energy system (monocrystalline) for amount of electric power required for running electric motor and other appliances such as fan, tube, bulb etc in water works site. including bi directional meter and inverter of suitable capaity as per guidelines issued by peda complete in all respects. , development of water works , providing & fixing g.i. barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard drawing d 6 & 8 (as per analysis a 6) , providing & fixing angle iron pickets with angle 40mm x40mm x 6mm including cost of concrete block & painting complete in all respects as per standard drawing d 8 & (as per analysis a 6). , providing & fixing d.hook complete with ms bolts size 300mm x 18mm as per standard drawing d 7 & analysis a 7 , construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard drawing d 3 & analysis a 3. , construction of masonry gate pillar including cost of ms steel gate size 1.22mtr x 1.37 mtr as per standard drawing with including d 4 & analysis a 4 complete in all respects , construction of cement concrete, foot path with masonry toe wall & earth filling inside water works as per standard drawing d 7 & analysis a 10. , providing & fixing ms sign board as per standard size of dwss as per analysis a 24 & drawing d 20 , construction of toe wall around the water works site (0.45 mtr depth) , enviornment , rough grassing including uprooting rank vegetation and weeds by digging the area to a depth of 15 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, mixing fertilizer, levelling and dressing for planting new grass, including disposal of all rubbish with all leads and lifts, planting doob grass in rows 15 cm apart in both directions, watering and maintenance till first mowing. , digging of pits in all kinds of soil & refilling the same, with the excavated earth mixed with well decayed farm yard manure @ 30% of pit volume and insecticide for termite control , supplying and planting permanent trees in prepared pits and watering , supplying and planting permanent shrubs in prepared pits and watering , carriage of material , extra for carriage of fine & course aggregate i.e. sand & bajri from query to water works site beyond 5 km (qty as worked out for the components to be constructed detail 1.9 & rate as per lead on csr + ceiling premium for the applicable lead beyond first 5 km) 30 km. , sand & bajri , operational & maintenace , operation and maintenance of water supply scheme for 3 months excluding electrical charges complete in all respects...

Water Resources Department - Punjab

33485954 e tenders are invited for the repair and rewinding of submersible motor pump of tube / well bharapur 38 of block saroya of dist sbs under t / well const. division ropar...

Municipal Corporation - Punjab

33463759 r/c estimate for installing new shallow tube well including pumping machinery in library park, phase 7, sas nagar ...

Water Supply And Sanitation Department - Punjab

33301949 tender for providing and installation a new telescopic tube well 200 150 mm i/d 130 mtrs depth drilled with reverse rotary rig against failed tube well at w/s scheme sherpur bahtlan in block hoshiarpur district hoshiarpur....

Water Supply And Sanitation Department - Punjab

33258285 supply of 1. tube well size ( 150mm i / d straight upto 200 mtr. depth ) at village jalalabad of block bhunerheri, distt patiala. ( under 15th finance commission ) 1. tube well size ( 150mm i / d straight upto 200 mtr. depth ) at village jalalabad of block bhunerheri, distt patiala. ( under 15th finance commission ) ...

Water Supply And Sanitation Department - Punjab

33236787 providing and installing tube / well size 250 x 200 mm i / d upto 150 mtr bgl with reverse rotary rigmethod, providing & laying rising main, p / f sluice valve & sluice valve chamber etc. at village burj baghel singh block malerkotla 1, district sangrur ( under head 4215 ) ...

Municipal Corporation - Punjab

33218508 supply of twin oxide water disinfectant for drinking water, feeding charges and maintenance of dozers at mc tube wells in moga city. ...

Punjab Water Supply And Sewerage Board - Punjab

33200499 providing and laying di k 9 rising main rising main balance work from proposed tube well ci di specials and all other works contingent thereto in mohalla marasgarh janj ghar to existing network near ohsr at dasuya ...

Punjab State Power Corporation Limited - Punjab

33191962 erection of 11 kv and lt lines installation of distribution transformers ht lt capacitors mcbs meter pillar boxes and allied works including erection work of domestic nrs industrial tube well and other connection as per approved pspcl drawings drawings design under normal development sis and deposit works 24hrs supply to dera dhanies bifurcation of feeders deloading of transformers and other works likely to be executed during 2022 23 on labour rates as per pspcl approved drawing design...

Punjab State Power Corporation Limited - Punjab

33187989 tender for erection of 11 kv & lt lines, installation of distribution transformers, ht/lt capacitors, mcbs meter pillar boxes & allied works including erection work of domestic, nrs, industrial, tube well & other connection as per approved pspcl drawings design under normal development, sis & deposit works, 24 hrs supply to dera dhani’s and other development works likely to be executed during 2022 23...

Punjab Water Resources Management And Development Corporation Limited - Punjab

33157621 material required for running and maintenance of tube / wells of various blocks of opt. & maint. division, pwrm&dc ltd: hoshiarpur l and t make 3 pole power contactor mnx 50 etc. l and t make 3 pole power contactor mnx 50 etc. , l&t make 3 pole power contactor mnx 50 cat no. cs 97075 , l&t make 3 pole power contactor mnx 70 cat no. 97076 for hoshiarpur / mahilpur / garhshankar...

Punjab Water Resources Management And Development Corporation Limited - Punjab

33157560 material required for running and maintenance of tube / wells of various blocks of opt. & maint. division, pwrm&dc ltd: hoshiarpur bch make contactor nhd series 4 pole ac control 40 amp etc. bch make contactor nhd series 4 pole ac control 40 amp etc. , bch make contactor nhd series 4 pole ac control 40 amp. cat no. nin , bch make contactor 70 amp. citation series 3 pole ac control e size cat no. mc10en22 for hoshiarpur / mahilpur / garhshankar...

Municipal Corporation - Punjab

33133996 rate contract estimate for installation of new shallow tube well in hawaldar joginder singh park, ward no.44...