Department Of Electronics And Information Technology - Punjab
39481706 bids are invited for uv lamp make aquapure (q3) , pre ro uv sterilizers (q3) mse total quantity : 13...
39481706 bids are invited for uv lamp make aquapure (q3) , pre ro uv sterilizers (q3) mse total quantity : 13...
39176163 bids are invited for philips uv lamp, 11 watt, pl sg23, 952011 (q3) total quantity : 25...
38512475 bids are invited for cannon apt 4800 bpsg uv lamp (pn: 421 0002 01) or equivalent (q3) total quantity : 3...
28442714 supply and installation of bio safety cabinet class ii type a approx. working space width = 1220 mm (4.0 ft) quantity required: 3 1. the biosafety cabinet will be used for microbial/animal cell culture work assigned to biological safety levels i, ii or iii, to be provided with germicidal uv lamp (uv lamp to be in working zone with on/off working timer), fluorescent lamp (≥ 1200 lux) and two electrical outlets. the width of working space should be strictly between 1200 – 1220 mm. 2. microprocessor controlled airstream (class ii) with lcd display. 3. the control system should have capability to constantly monitor and display airflow velocity and produce visual as well as audible alarms in case of low airflow/ airflow failure. 4. these biosafety cabinets are to be housed in a clean modular facility with cubicles. therefore, overall dimensions of the quoted equipment should strictly be: width: ≤ 1340 mm depth: 750 – 800 mm height (including support stand): ≤ 2225 mm 5. construction: (a) main body: electro galvanized steel or equivalent. (b) single piece stainless steel (ss) interior side walls and back walls (ss surface for easy cleaning). corners should be curved. (c) the working area tray/platform should be removable for easy cleaning and disinfection of working zone. (d) cabinet should be provided with rs 232 port for interface. (e) cabinet with only a dc motor should be quoted. 6. downflow and exhaust filters: (a) ulpa/hepa (b) filter efficiency ≥ 99.99 % at 0.1 – 0.3 μm particle size. 7. airflow velocity: 0.4 0.6 m/s, air flow volume maintained with proper inflow, down flow and exhaust. 8. provided with fixtures for air/gas/vacuum/nitrogen. adapters and other accessories required for lpg gas connection should be supplied along with the equipment. 9. sound level: 50 – 70 dba 10. safety: visual and/or audible alarm for low air flow velocity, filters, excess door open. 11. the system should be supplied with support stand with castor wheels (from original equipment manufacturer (same manufacturer)). 12. certification: nsf 49 certified and listed on nsf website. 13. iq/oq/pq documentation to be included. 14. all costs of installation, validation performance demonstration at site and on site testing like dop test, particle test, noise level test, current/voltage test, vibration etc. to be included in main quote. 15. with each biosafety cabinet, one high quality ergonomic lab chair optimized for sitting while working in biosafety cabinet should be supplied. the chair should be preferably from the original equipment manufacturer. 16. warranty: 5 years from the date of installation and two service visit of company trained service engineer in a year during the warranty period. 17. power supply: 230 v and 50 hz 18. the company should have the necessary iso certification with regards to quality systems. general conditions: the vendor should provide complete brochure for the quoted model and highlight the specifications in the brochure. the vendor should provide point wise compliance statement in tabular form as given in tender document, clearly mentioning the compliance/deviation (if any). any accessory items required for the instrument should also be quoted....
21396465 supply of article 1. 3710027200 peristaftic pump tubes, pvc, black/black tabs. 12/pk. used for pumping reagents when using vga 76/77 3710027300 peristaltic pump tubes, pvc, black/black tabs. 12/pk. used for pumping reagents when using vga 76/77 3. 1510226700 lock nut for nebulizer adjr m12xo.5, 1/pfor mark 7 spray chamber 4. 310046600 bearing bush, nebulizer, ertalyte, 1/pk for mark 7 spray chamber 5. 5190 8270 cadmium, 1000 ug/mi, loomi 6. 5190 8275 chromium, 1000 ug/mi, loomi 7. 5190 8287 lead, 1000 ug/ml, loom i 8. 5190 8260 arsenic, 1000 ugjml, loomi 9. 5190 8298 nickel, 1000 ugjml, looml 10. 5190 8279 copper, 1000 ugjml, loomi 11. 5190 8325 zinc, 1000 ug/mi, loomi 12. 7210034200 graphite tube alignment tool, 1/pk 13. 6610011600 plastic reagent vessel and cap 500mll/p. high density polyethylene, square 14. g8431 80000 deuterium uv lamp for aa instruments, 1/p replacement source lamp for background corrector used in current and most previous aa instrument models 9910024700 nebulizer cleaning wire, 3/pk. 3 x 0.3m lengths for mark v, vi and 7 spraychambers 9910093400 mark 7 spray chamber 0 ring kit,aqueous. lncl 0 rings for screw bead adjr (1 ea), neb capillary (1 ea), capillary guide + venturi (7 ea), s/chamber bung + burner (3 ea), and neb block (1 ea) 17. 9910053900 burner cleaning + alignment card, 100/pk 18. 7210027600 nebulizer capillary extract tool, 1/pk.for mark 7 spray chamber 19. 9910115600 plastic beakers loml bulk std, psd,5/pk. fits the 5 central positions inthe sample carousel for bulk standard....